Skip to contentSkip to conversation

unreadable drives can be synchronized?

DISCUSSION Andrew Burgess 4 participants 5 messages May 18, 2007 – May 23, 2007 MD RAID

lore
Share & tools
lore
#0 lore raw
Quoted 2 lines

Basically, B appears to be "write-only"; it will never return an error on a write, but just try to read from it, and you will be sorry.

It would be interesting to see what SMART says about drive B, especially the short and long self tests.

#1 lore raw
Quoted 5 lines · Andrew Burgess
Quoted 2 lines

Basically, B appears to be "write-only"; it will never return an error on a write, but just try to read from it, and you will be sorry.

It would be interesting to see what SMART says about drive B, especially the short and long self tests.

I wouldn't rely on SMART.

I have a broken drive, which has lots of badblocks - but SMART happily claims it's fine (short/long tests are completed without errors).

Signature · 2 lines
Tomasz Chmielewski
http://wpkg.org
#4 lore raw
In reply to Andrew Burgess
Quoted 11 lines · Andrew Burgess
Quoted 2 lines

Basically, B appears to be "write-only"; it will never return an error on a write, but just try to read from it, and you will be sorry.

It would be interesting to see what SMART says about drive B, especially the short and long self tests.

-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

On my hard drives, automatic online testing is turned on, and so is automatic offline testing. I run the long self-test once a week.

I have two drives which can play the role of B. One of them has this SMART output:

[root@cmccabe-devel root]# smartctl -d ata /dev/sdb -H smartctl version 5.36 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen Home page is http://smartmontools.sourceforge.net/

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED! Drive failure expected in less than 24 hours. SAVE ALL DATA. Failed Attributes:

ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0033   004   004   024    Pre-fail 

Always FAILING_NOW 133273031255

The other one passes SMART.
Both of them eat data, though.

Colin

#2 lore raw
In reply to Tomasz Chmielewski
Quoted 4 lines · Tomasz Chmielewski
Quoted 3 lines · Andrew Burgess
Quoted 2 lines

Basically, B appears to be "write-only"; it will never return an error on a write, but just try to read from it, and you will be sorry.

Quoted 8 lines
Quoted 2 lines

It would be interesting to see what SMART says about drive B, especially the short and long self tests.

I wouldn't rely on SMART.

I have a broken drive, which has lots of badblocks - but SMART happily claims it's fine (short/long tests are completed without errors).

If you haven't seen Google's hard drive study yet, you should take a look. It's at http://labs.google.com/papers/disk_failures.pdf

The conclusion says that "some of the SMART parameters are well-correlated with higher failure probabilities," but also that "a large fraction of [google's] failed drives have shown no SMART error signals whatsoever."

Colin

#3 lore raw
Quoted 16 lines · Colin McCabe
Quoted 5 lines · Tomasz Chmielewski
Quoted 1 line · Andrew Burgess
Quoted 1 line

Basically, B appears to be "write-only"; it will never return an

error on a

Quoted 2 lines
Quoted 1 line

write, but just try to read from it, and you will be sorry.

Quoted 9 lines
Quoted 1 line

It would be interesting to see what SMART says about drive B,

especially

Quoted 1 line

the short and long self tests.

I wouldn't rely on SMART.

I have a broken drive, which has lots of badblocks - but SMART happily claims it's fine (short/long tests are completed without errors).

Quoted 7 lines

If you haven't seen Google's hard drive study yet, you should take a look. It's at http://labs.google.com/papers/disk_failures.pdf

The conclusion says that "some of the SMART parameters are well-correlated with higher failure probabilities," but also that "a large fraction of [google's] failed drives have shown no SMART error signals whatsoever."

Having covered that in a presentation to a user group related to SMART. may I offer a paraphrase which may be more obvious to people who are not native speakers of English:

High counts of some SMART parameters indicate that the drive is likely to fail. However, most drives fail without warning.

Signature · 3 lines
bill davidsen <[email protected]>
 CTO TMR Associates, Inc
 Doing interesting things with small computers since 1979