Skip to contentSkip to conversation

RFC: MCA/MCE concept

DISCUSSION Christoph Egger 4 participants 24 messages May 29, 2007 – Jun 21, 2007

lore
Share & tools
lore
#0 lore raw

Hello!

The current MCA/MCE support in Xen is that it dumps the error and panics.

In the following concept I propose here, there are two places where Xen has to react on.
I) Xen receives a MCE from the CPU and
II) Xen receives Dom0 instructions via Hypercall

The term "self-healing" below is used in the sense of using the most propriate technique(s) to handle an error such as MPR
(http://www.opensparc.net/pubs/papers/MPR_DSN06.pdf),
online-spare RAM or killing/restarting of impacted processes
to prevent crashes of whole guests or the whole machine.

case I) - Xen reveives a MCE from the CPU

1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose
2b) error == UE and UE impacts Xen or Dom0:
Xen does some self-healing
and notifies Dom0 on success if Dom0 installed MCA event handler or Xen panics on failure
2c) error == UE and UE impacts DomU:
In case of Dom0 installed MCA event handler:
Xen notifies Dom0 and Dom0 tells Xen whether
to also notify DomU and/or does some operations on the DomU (case II)
In case Dom0 did not install MCA event handler,
Xen notifies DomU
3a) DomU is a PV guest:
if DomU installed MCA event handler, it gets notified to perform
self-healing
if DomU did not install MCA event handler, notify Dom0 to do
some operations on DomU (case II)
if neither DomU nor Dom0 did not install MCA event handlers,
then Xen kills DomU
3b) DomU is a HVM guest:
if DomU features a PV driver then behave as in 3a)
if DomU enabled MCA/MCE via MSR, inject MCE into guest if DomU did not enable MCA/MCE via MSR, notify Dom0
to do some operations on DomU (case II)
if neither DomU enabled MCA/MCE nor Dom0 did not install
MCA event handler, Xen kills DomU

case II) - Xen reveives Dom0 instructions via Hypercall

There are different reasons, why Xen should do something.

- Dom0 got enough CEs so that UEs are very likely to happen in order to "circumvent" UEs.
- Possible operations on a DomU
- save/restore DomU
- (live-)migrate DomU to a different physical machine
- etc.

Some details

MCE

When an MCE occures, then all the stuff above should NOT happen within the handler, because when an MCE happens within the MCE handler, then the CPU enters shutdown state. So the mail topic "NMI deferal on i386" may be related here.

Notifying guests

Above I am talking about MCA event handler. What I actually mean is a way to inform the guest something happened.
I choosed the term "MCA event handler", because I think, using the event mechanism fits best for this purpose.

Regarding HVM guests with no "MCA PV driver", can enable/disable certain types of errors. They can even control if tehy want to get an exception or do polling.
I would prefer to always inject exceptions into the HVM guest. A HVM guest can't prevent when it always see's exceptions, but I know if they behave correctly, when they assume to get all or certain errors via polling.

Guests which already feature fault management to a certain level when running non-virtualized can easily re-use this capability to decode the error telemetry and handle the error in the virtualized case. Thus forwarding/injecting the error into a guest will only require the translation of the physical/virtual address reported by the HW into guest physical/guest virtual addresses. The error code itself needs no translation/abstraction.

self-healing

IMO, only Xen should use the HW features such as online-spare RAM, which has been introduced in AMD K8 RevF. The HW features should never be visible to any DomUs in order to reduce complexity in Xen. Software-only techniques such as MPR are ok in all guests. Only the Dom0 can tell Xen to do something using HW features.

Christoph

Signature · 12 lines
AMD Saxony, Dresden Germany
Operating System Research Center

Legal Information:
AMD Saxony Limited Liability Company & Co. KG
Sitz (Geschäftsanschrift):
   Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland
Registergericht Dresden: HRA 4896
vertretungsberechtigter Komplementär:
   AMD Saxony LLC (Sitz Wilmington, Delaware, USA)
Geschäftsführer der AMD Saxony LLC:
   Dr. Hans-R. Deppe, Thomas McCoy
#1 lore raw
Quoted 8 lines

case I) - Xen reveives a MCE from the CPU

1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose
2b) error == UE and UE impacts Xen or Dom0:

A very important aspect here is how you want to classify what impact an uncorrectable has - generally, I can see very few situations where you could confine the impact to a sub-portion of the system (i.e. a single domU, dom0, or Xen). The general rule in my opinion must be to halt the system, the question just is how likely it is that you can get a meaningful message out (to screen, serial, or logs) that can help analyze the problem afterwards. If it is somewhat likely, then dom0 should be involved, otherwise Xen should just shut down the system.

Quoted 11 lines

Xen does some self-healing
and notifies Dom0 on success if Dom0 installed MCA event handler or Xen panics on failure
2c) error == UE and UE impacts DomU:
In case of Dom0 installed MCA event handler:
Xen notifies Dom0 and Dom0 tells Xen whether
to also notify DomU and/or does some operations on the DomU (case II)
In case Dom0 did not install MCA event handler,
Xen notifies DomU
3a) DomU is a PV guest:

Quoted 8 lines

if DomU installed MCA event handler, it gets notified to perform
self-healing
if DomU did not install MCA event handler, notify Dom0 to do
some operations on DomU (case II)
if neither DomU nor Dom0 did not install MCA event handlers,
then Xen kills DomU
3b) DomU is a HVM guest:
if DomU features a PV driver then behave as in 3a)

What significance do pv drivers have here? Or do you mean a pv MCA driver?

Quoted 5 lines

if DomU enabled MCA/MCE via MSR, inject MCE into guest if DomU did not enable MCA/MCE via MSR, notify Dom0
to do some operations on DomU (case II)
if neither DomU enabled MCA/MCE nor Dom0 did not install
MCA event handler, Xen kills DomU

Injecting an MCE to a hvm guest seems at least questionable. It can't really do anything about it (it doesn't even know the real topology of the system it's running on, so addresses stored in MSRs are meaningless - either you allow the to be read untranslated [in which case the guest cannot make sense of them] or you do translation for the guest [in which case it might make assumptions about co-locality of other nearby pages which will be wrong]).
Doing this to a pv domU for purely notification purposes (where the guest knows it's running virtualized) is clearly a different matter.

Quoted 10 lines

case II) - Xen reveives Dom0 instructions via Hypercall

There are different reasons, why Xen should do something.

- Dom0 got enough CEs so that UEs are very likely to happen in order to "circumvent" UEs.
- Possible operations on a DomU
- save/restore DomU
- (live-)migrate DomU to a different physical machine
- etc.

Very heavy-weight operations, which I think are unlikely to succeed if you already suspect the system's going to suffer a UE soon.

Jan

#2 lore raw
Quoted 9 lines · On Wednesday 30 May 2007 09:19:12 Jan Beulich wrote:
Quoted 8 lines

case I) - Xen reveives a MCE from the CPU

1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose
2b) error == UE and UE impacts Xen or Dom0:

Quoted 8 lines

A very important aspect here is how you want to classify what impact an uncorrectable has - generally, I can see very few situations where you could confine the impact to a sub-portion of the system (i.e. a single domU, dom0, or Xen). The general rule in my opinion must be to halt the system, the question just is how likely it is that you can get a meaningful message out (to screen, serial, or logs) that can help analyze the problem afterwards. If it is somewhat likely, then dom0 should be involved, otherwise Xen should just shut down the system.

Here you can best help out using HW features to handle errors. AMD CPUs features online-spare RAM and Chipkill since K8 RevF.

CPUs such as the Sparc features Data Poisoning. That would be the most handy technique that can be used here.

Maybe this line:

Quoted 1 line
Quoted 1 line

Xen does some self-healing

should be this:

Xen *tries* to do some self-healing

Quoted 2 lines
Quoted 2 lines

and notifies Dom0 on success if Dom0 installed MCA event handler or Xen panics on failure

The first implemenation can just panic here. The self-healing will be implemented and improved over time.

Quoted 17 lines
Quoted 8 lines

2c) error == UE and UE impacts DomU:
In case of Dom0 installed MCA event handler:
Xen notifies Dom0 and Dom0 tells Xen whether
to also notify DomU and/or does some operations on the DomU (case II)
In case Dom0 did not install MCA event handler,
Xen notifies DomU
3a) DomU is a PV guest:

Quoted 8 lines

if DomU installed MCA event handler, it gets notified to perform
self-healing
if DomU did not install MCA event handler, notify Dom0 to do
some operations on DomU (case II)
if neither DomU nor Dom0 did not install MCA event handlers,
then Xen kills DomU
3b) DomU is a HVM guest:
if DomU features a PV driver then behave as in 3a)

Quoted 2 lines

What significance do pv drivers have here? Or do you mean a pv MCA driver?

Yes, I mean the pv MCA driver.

Quoted 7 lines
Quoted 6 lines

if DomU enabled MCA/MCE via MSR, inject MCE into guest if DomU did not enable MCA/MCE via MSR, notify Dom0
to do some operations on DomU (case II)
if neither DomU enabled MCA/MCE nor Dom0 did not install
MCA event handler, Xen kills DomU

Quoted 7 lines

Injecting an MCE to a hvm guest seems at least questionable. It can't really do anything about it (it doesn't even know the real topology of the system it's running on, so addresses stored in MSRs are meaningless - either you allow them to be read untranslated [in which case the guest cannot make sense of them] or you do translation for the guest [in which case it might make assumptions about co-locality of other nearby pages which will be wrong]).

Yes, Xen should do the translation for the guest. The assumptions must be fixed then. I know that's easier said than done.

Quoted 2 lines

Doing this to a pv domU for purely notification purposes (where the guest knows it's running virtualized) is clearly a different matter.

Yes, I agree with you here. The general idea behind informing a DomU is to let its own fault management handle the error. It is always better to let it kill a screen saver process and keep the word processor running than killing the whole guest. The DomU should crash itself if it thinks that's the best.

Quoted 11 lines
Quoted 10 lines

case II) - Xen reveives Dom0 instructions via Hypercall

There are different reasons, why Xen should do something.

- Dom0 got enough CEs so that UEs are very likely to happen in order to "circumvent" UEs.
- Possible operations on a DomU
- save/restore DomU
- (live-)migrate DomU to a different physical machine
- etc.

Quoted 2 lines

Very heavy-weight operations, which I think are unlikely to succeed if you already suspect the system's going to suffer a UE soon.

Yes, they are heavy-weight operations. Do you have some ideas, what a Dom0 can do?

The idea here is that the Dom0's fault management helps guests to survive as best as possible.

Christoph

Signature · 12 lines
AMD Saxony, Dresden Germany
Operating System Research Center

Legal Information:
AMD Saxony Limited Liability Company & Co. KG
Sitz (Geschäftsanschrift):
   Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland
Registergericht Dresden: HRA 4896
vertretungsberechtigter Komplementär:
   AMD Saxony LLC (Sitz Wilmington, Delaware, USA)
Geschäftsführer der AMD Saxony LLC:
   Dr. Hans-R. Deppe, Thomas McCoy
#3 lore raw
Quoted 20 lines
Quoted 1 line
Quoted 1 line

"Christoph Egger" <[email protected]> 30.05.07 09:45 >>>

Quoted 9 lines · On Wednesday 30 May 2007 09:19:12 Jan Beulich wrote:
Quoted 8 lines

case I) - Xen reveives a MCE from the CPU

1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose
2b) error == UE and UE impacts Xen or Dom0:

Quoted 8 lines

A very important aspect here is how you want to classify what impact an uncorrectable has - generally, I can see very few situations where you could confine the impact to a sub-portion of the system (i.e. a single domU, dom0, or Xen). The general rule in my opinion must be to halt the system, the question just is how likely it is that you can get a meaningful message out (to screen, serial, or logs) that can help analyze the problem afterwards. If it is somewhat likely, then dom0 should be involved, otherwise Xen should just shut down the system.

Quoted 5 lines

Here you can best help out using HW features to handle errors. AMD CPUs features online-spare RAM and Chipkill since K8 RevF.

CPUs such as the Sparc features Data Poisoning. That would be the most handy technique that can be used here.

But that assumes the error is recoverable (i.e. no other data got corrupted). You still didn't clarify how you intend to determine the impact an uncorrectable error had.

Quoted 30 lines
Quoted 10 lines
Quoted 9 lines

3a) DomU is a PV guest:
if DomU installed MCA event handler, it gets notified to perform
self-healing
if DomU did not install MCA event handler, notify Dom0 to do
some operations on DomU (case II)
if neither DomU nor Dom0 did not install MCA event handlers,
then Xen kills DomU
3b) DomU is a HVM guest:
if DomU features a PV driver then behave as in 3a)

Quoted 2 lines

What significance do pv drivers have here? Or do you mean a pv MCA driver?

Yes, I mean the pv MCA driver.

Quoted 7 lines
Quoted 6 lines

if DomU enabled MCA/MCE via MSR, inject MCE into guest if DomU did not enable MCA/MCE via MSR, notify Dom0
to do some operations on DomU (case II)
if neither DomU enabled MCA/MCE nor Dom0 did not install
MCA event handler, Xen kills DomU

Quoted 7 lines

Injecting an MCE to a hvm guest seems at least questionable. It can't really do anything about it (it doesn't even know the real topology of the system it's running on, so addresses stored in MSRs are meaningless - either you allow them to be read untranslated [in which case the guest cannot make sense of them] or you do translation for the guest [in which case it might make assumptions about co-locality of other nearby pages which will be wrong]).

Quoted 2 lines

Yes, Xen should do the translation for the guest. The assumptions must be fixed then. I know that's easier said than done.

Exactly - you are proposing to fix all possible OSes, including sufficiently old ones. That's impossible. And I can't even see why an OS intended to run on native hardware would care to try to deal with virtualization aspects like this.

Jan

#4 lore raw
Quoted 24 lines · On Wednesday 30 May 2007 10:49:40 Jan Beulich wrote:
Quoted 24 lines
Quoted 1 line
Quoted 1 line

"Christoph Egger" <[email protected]> 30.05.07 09:45 >>>

Quoted 9 lines · On Wednesday 30 May 2007 09:19:12 Jan Beulich wrote:
Quoted 8 lines

case I) - Xen reveives a MCE from the CPU

1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose
2b) error == UE and UE impacts Xen or Dom0:

Quoted 8 lines

A very important aspect here is how you want to classify what impact an uncorrectable has - generally, I can see very few situations where you could confine the impact to a sub-portion of the system (i.e. a single domU, dom0, or Xen). The general rule in my opinion must be to halt the system, the question just is how likely it is that you can get a meaningful message out (to screen, serial, or logs) that can help analyze the problem afterwards. If it is somewhat likely, then dom0 should be involved, otherwise Xen should just shut down the system.

Here you can best help out using HW features to handle errors. AMD CPUs features online-spare RAM and Chipkill since K8 RevF.

Quoted 6 lines
Quoted 2 lines

CPUs such as the Sparc features Data Poisoning. That would be the most handy technique that can be used here.

But that assumes the error is recoverable (i.e. no other data got corrupted). You still didn't clarify how you intend to determine the impact an uncorrectable error had.

I know. I am lacking a sudden inspiration here.
That's why I discuss this here before writing code that goes to nowhere. Anyone here with a flash of genius? :-)

Quoted 29 lines
Quoted 29 lines
Quoted 10 lines
Quoted 9 lines

3a) DomU is a PV guest:
if DomU installed MCA event handler, it gets notified to perform
self-healing
if DomU did not install MCA event handler, notify Dom0 to do
some operations on DomU (case II)
if neither DomU nor Dom0 did not install MCA event handlers,
then Xen kills DomU
3b) DomU is a HVM guest:
if DomU features a PV driver then behave as in 3a)

Quoted 2 lines

What significance do pv drivers have here? Or do you mean a pv MCA driver?

Yes, I mean the pv MCA driver.

Quoted 13 lines
Quoted 5 lines

if DomU enabled MCA/MCE via MSR, inject MCE into guest if DomU did not enable MCA/MCE via MSR, notify Dom0
to do some operations on DomU (case II)
if neither DomU enabled MCA/MCE nor Dom0 did not install
MCA event handler, Xen kills DomU

Injecting an MCE to a hvm guest seems at least questionable. It can't really do anything about it (it doesn't even know the real topology of the system it's running on, so addresses stored in MSRs are meaningless
- either you allow them to be read untranslated [in which case the guest cannot make sense of them] or you do translation for the guest [in which case it might make assumptions about co-locality of other nearby pages which will be wrong]).

Quoted 7 lines
Quoted 2 lines

Yes, Xen should do the translation for the guest. The assumptions must be fixed then. I know that's easier said than done.

Exactly - you are proposing to fix all possible OSes, including sufficiently old ones. That's impossible. And I can't even see why an OS intended to run on native hardware would care to try to deal with virtualization aspects like this.

I think, it was not obvious that
Xen should not inject failures into DomU that don't feature a fault management. In this case, either Dom0 tells Xen what to do with the DomU or Xen just kills the DomU.

<snippet from above>

Quoted 1 line
Quoted 1 line
Quoted 1 line
Quoted 1 line

3a) DomU is a PV guest:

                    ....
Quoted 6 lines
Quoted 6 lines
Quoted 6 lines
Quoted 6 lines

if DomU did not install MCA event handler, notify Dom0 to do
some operations on DomU (case II)
if neither DomU nor Dom0 did not install MCA event handlers,
then Xen kills DomU

3b) DomU is a HVM guest:

                    ....
Quoted 4 lines
Quoted 4 lines
Quoted 4 lines
Quoted 4 lines

if DomU did not enable MCA/MCE via MSR, notify Dom0
to do some operations on DomU (case II)
if neither DomU enabled MCA/MCE nor Dom0 did not install
MCA event handler, Xen kills DomU

</snippet>

Christoph

Signature · 12 lines
AMD Saxony, Dresden Germany
Operating System Research Center

Legal Information:
AMD Saxony Limited Liability Company & Co. KG
Sitz (Geschäftsanschrift):
   Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland
Registergericht Dresden: HRA 4896
vertretungsberechtigter Komplementär:
   AMD Saxony LLC (Sitz Wilmington, Delaware, USA)
Geschäftsführer der AMD Saxony LLC:
   Dr. Hans-R. Deppe, Thomas McCoy
#5 lore raw
Quoted 16 lines
Quoted 8 lines
Quoted 8 lines
Quoted 7 lines

Injecting an MCE to a hvm guest seems at least questionable. It can't really do anything about it (it doesn't even know the real topology of the system it's running on, so addresses stored in MSRs are meaningless
- either you allow them to be read untranslated [in which case the guest cannot make sense of them] or you do translation for the guest [in which case it might make assumptions about co-locality of other nearby pages which will be wrong]).

Quoted 7 lines
Quoted 2 lines

Yes, Xen should do the translation for the guest. The assumptions must be fixed then. I know that's easier said than done.

Exactly - you are proposing to fix all possible OSes, including sufficiently old ones. That's impossible. And I can't even see why an OS intended to run on native hardware would care to try to deal with virtualization aspects like this.

Quoted 4 lines

I think, it was not obvious that
Xen should not inject failures into DomU that don't feature a fault management. In this case, either Dom0 tells Xen what to do with the DomU or Xen just kills the DomU.

You apparently didn't get my point - even if the guest set up MCE properly (by setting CR4.MCE and possibly writing some MSRs) you cannot conclude that it is aware of the fact that it is running in a virtualized environment and that guest physical address relations do not map to machine physical address relations (i.e. a set of pages contiguous in gpa space is almost guaranteed to be discontiguous in mpa space). Hence if it is more than a single byte/cache line/page that is affected, any such assumptions made in the guest will be wrong.

Jan

#6 lore raw
Quoted 21 lines · On Wednesday 30 May 2007 11:59:31 Jan Beulich wrote:
Quoted 16 lines
Quoted 8 lines
Quoted 8 lines
Quoted 7 lines

Injecting an MCE to a hvm guest seems at least questionable. It can't really do anything about it (it doesn't even know the real topology of the system it's running on, so addresses stored in MSRs are meaningless - either you allow them to be read untranslated [in which case the guest cannot make sense of them] or you do translation for the guest [in which case it might make assumptions about co-locality of other nearby pages which will be wrong]).

Quoted 7 lines
Quoted 2 lines

Yes, Xen should do the translation for the guest. The assumptions must be fixed then. I know that's easier said than done.

Exactly - you are proposing to fix all possible OSes, including sufficiently old ones. That's impossible. And I can't even see why an OS intended to run on native hardware would care to try to deal with virtualization aspects like this.

Quoted 4 lines

I think, it was not obvious that
Xen should not inject failures into DomU that don't feature a fault management. In this case, either Dom0 tells Xen what to do with the DomU or Xen just kills the DomU.

Quoted 8 lines

You apparently didn't get my point - even if the guest set up MCE properly (by setting CR4.MCE and possibly writing some MSRs) you cannot conclude that it is aware of the fact that it is running in a virtualized environment and that guest physical address relations do not map to machine physical address relations (i.e. a set of pages contiguous in gpa space is almost guaranteed to be discontiguous in mpa space). Hence if it is more than a single byte/cache line/page that is affected, any such assumptions made in the guest will be wrong.

Ah, I see. So HVM guests can only handle those errors where this assumption is guaranteed to be correct. Xen needs to check the error type, the address and the size (= address range) for this.
If Xen can't determine for sure, the guest can handle this right, then Xen has to handle the DomU as a guest which does not feature fault management.

Christoph

Signature · 12 lines
AMD Saxony, Dresden, Germany
Operating System Research Center

Legal Information:
AMD Saxony Limited Liability Company & Co. KG
Sitz (Geschäftsanschrift):
   Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland
Registergericht Dresden: HRA 4896
vertretungsberechtigter Komplementär:
   AMD Saxony LLC (Sitz Wilmington, Delaware, USA)
Geschäftsführer der AMD Saxony LLC:
   Dr. Hans-R. Deppe, Thomas McCoy
#7 lore raw
In reply to Christoph Egger

Hi,

On 05/30/07 10:10, Christoph Egger wrote:

[cut]

Quoted 14 lines
Quoted 14 lines
Quoted 14 lines
Quoted 9 lines
Quoted 1 line

2b) error == UE and UE impacts Xen or Dom0:

A very important aspect here is how you want to classify what impact an uncorrectable has - generally, I can see very few situations where you could confine the impact to a sub-portion of the system (i.e. a single domU, dom0, or Xen). The general rule in my opinion must be to halt the system, the question just is how likely it is that you can get a meaningful message out (to screen, serial, or logs) that can help analyze the problem afterwards. If it is somewhat likely, then dom0 should be involved, otherwise Xen should just shut down the system.

Here you can best help out using HW features to handle errors. AMD CPUs features online-spare RAM and Chipkill since K8 RevF.

CPUs such as the Sparc features Data Poisoning. That would be the most handy technique that can be used here.

Quoted 7 lines
Quoted 3 lines

But that assumes the error is recoverable (i.e. no other data got corrupted). You still didn't clarify how you intend to determine the impact an uncorrectable error had.

I know. I am lacking a sudden inspiration here.
That's why I discuss this here before writing code that goes to nowhere. Anyone here with a flash of genius? :-)

For a first phase I'd suggest that treating an uncorrectable error as terminal to the entire system (e.g., panic hypervisor or setup a hardware reset mechanism such as Sync Flood) is practical and safe, and allows us to concentrate on getting some more basic elements in place. As Christoph says we really need some form of data poisoning supported on the platform to really be able to isolate the impact of an uncorrectable error. In the absence of such support I think some fancy heuristics could work in some limited cases (e.g., a memory uncorrectable on a page that only a domU has a mapping to and which is not shared with any other domain not even via a front/backend driver) but the penalty for bugs in those heuristics is silent data corruption which is the ultimate crime.

Quoted 10 lines
Quoted 10 lines
Quoted 10 lines
Quoted 10 lines
Quoted 10 lines

3a) DomU is a PV guest:
if DomU installed MCA event handler, it gets notified to perform
self-healing
if DomU did not install MCA event handler, notify Dom0 to do
some operations on DomU (case II)
if neither DomU nor Dom0 did not install MCA event handlers,
then Xen kills DomU
3b) DomU is a HVM guest:
if DomU features a PV driver then behave as in 3a)

Quoted 2 lines
Quoted 2 lines
Quoted 2 lines
Quoted 2 lines

What significance do pv drivers have here? Or do you mean a pv MCA driver?

[cut]

My feeling is that the hypervisor and dom0 own the hardware and as such all hardware fault management should reside there. So we should never deliver any form of #MC to a domU, nor should a poll of MCA state from a domU ever observe valid state (e.g, make the RDMSR return 0). So all handling, logging and diagnosis as well as hardware response actions (such as to deploy an online spare chip-select) are controlled in the hypervisor/dom0 combination. That seems a consistent model - e.g., if a domU is migrated to another system it should not carry the diagnosis state of the original system across etc, since that belongs with the one domain that cannot migrate.

But that is not to say that (I think at a future phase) domU should not participate in a higher-level fault management function, at the direction of the hypervisor/dom0 combo. For example if/when we can isolate an uncorrectable error to a single domU we could forward such an event to the affected domU if it has registered its ability/interest in such events. These won't be in the form of a faked #MC or anything, instead they'd be some form of synchronous trap experienced when next the affected domU context resumes on CPU. The intelligent domU handler can then decide whether the domU must panic, whether it could simply kill the affected process etc. Those details are clearly sketchy, but the idea is to up-level the communication to a domU to be more like "you're broken" rather than "here's a machine-level hardware error for you to interpret and decide what to do with".

Gavin

#8 lore raw

[snip]

Quoted 6 lines

My feeling is that the hypervisor and dom0 own the hardware and as such
all hardware fault management should reside there. So we should never deliver any form of #MC to a domU, nor should a poll of MCA state from a domU ever observe valid state (e.g, make the RDMSR return 0). So all handling, logging and diagnosis as well as hardware

Quoted 8 lines

response actions
(such as to deploy an online spare chip-select) are controlled in the hypervisor/dom0 combination. That seems a consistent model - e.g.,
if a domU is migrated to another system it should not carry the diagnosis state of the original system across etc, since that belongs with
the one domain that cannot migrate.

I agree entirely with this.

Quoted 10 lines

But that is not to say that (I think at a future phase) domU should not
participate in a higher-level fault management function, at the direction
of the hypervisor/dom0 combo. For example if/when we can isolate an uncorrectable error to a single domU we could forward such an event to the affected domU if it has registered its ability/interest in such events. These won't be in the form of a faked #MC or anything, instead they'd be some form of synchronous trap experienced when next

Quoted 8 lines

the affected domU context resumes on CPU. The intelligent domU handler
can then decide whether the domU must panic, whether it could simply kill the affected process etc. Those details are clearly sketchy, but the
idea is to up-level the communication to a domU to be more like "you're broken" rather than "here's a machine-level hardware error for you to interpret and decide what to do with".

Yes, this makes much more sense than forwarding #MC, as the guest would have a hard time to actually do anything really useful with this. As far as I know, most uncorrectable errors are near enough entirely fatal in most commercial non-Enterprise OS's anyways - e.g. in Windows XP or Server 2K3, it always ends in a blue-screen - which is hardly any better than the guest being "humanely euthenazed" by Dom0.

I take it this would be some sort of hypercall (available through the regular PV-driver interface for HVM guests) to say "Let me know if I'm broken - trap on vector X".

--
Mats

Quoted 10 lines

Gavin

_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xensource.com/xen-devel

#9 lore raw
Quoted 44 lines · Mats

[snip]

Quoted 6 lines

My feeling is that the hypervisor and dom0 own the hardware and as such
all hardware fault management should reside there. So we should never deliver any form of #MC to a domU, nor should a poll of MCA state from a domU ever observe valid state (e.g, make the RDMSR return 0). So all handling, logging and diagnosis as well as hardware

Quoted 8 lines

response actions
(such as to deploy an online spare chip-select) are controlled in the hypervisor/dom0 combination. That seems a consistent model - e.g.,
if a domU is migrated to another system it should not carry the diagnosis state of the original system across etc, since that belongs with
the one domain that cannot migrate.

I agree entirely with this.

Quoted 9 lines

But that is not to say that (I think at a future phase) domU should not
participate in a higher-level fault management function, at the direction
of the hypervisor/dom0 combo. For example if/when we can isolate an uncorrectable error to a single domU we could forward such an event to the affected domU if it has registered its ability/interest in such events. These won't be in the form of a faked #MC or anything, instead they'd be some form of synchronous trap experienced when next

Quoted 8 lines

the affected domU context resumes on CPU. The intelligent domU handler
can then decide whether the domU must panic, whether it could simply kill the affected process etc. Those details are clearly sketchy, but the
idea is to up-level the communication to a domU to be more like "you're broken" rather than "here's a machine-level hardware error for you to interpret and decide what to do with".

Yes, this makes much more sense than forwarding #MC, as the guest would have a hard time to actually do anything really useful with this. As far as I know, most uncorrectable errors are near enough entirely fatal in most commercial non-Enterprise OS's anyways - e.g. in Windows XP or Server 2K3, it always ends in a blue-screen - which is hardly any better than the guest being "humanely euthenazed" by Dom0.

Quoted 3 lines

I take it this would be some sort of hypercall (available through the regular PV-driver interface for HVM guests) to say "Let me know if I'm broken - trap on vector X".

For short, guests with a PV MCA driver will see a certain event (assuming the event mechanism will be used for the notification) and guests w/o a PV MCA driver will see a "General Protection Fault". Is that right?

Quoted 5 lines

--
Mats

Quoted 2 lines

Gavin

Signature · 12 lines
AMD Saxony, Dresden, Germany
Operating System Research Center

Legal Information:
AMD Saxony Limited Liability Company & Co. KG
Sitz (Geschäftsanschrift):
   Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland
Registergericht Dresden: HRA 4896
vertretungsberechtigter Komplementär:
   AMD Saxony LLC (Sitz Wilmington, Delaware, USA)
Geschäftsführer der AMD Saxony LLC:
   Dr. Hans-R. Deppe, Thomas McCoy
#10 lore raw
Quoted 70 lines

-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of Christoph Egger
Sent: 01 June 2007 09:12
To: [email protected]
Cc: Gavin Maltby
Subject: Re: [Xen-devel] RFC: MCA/MCE concept

Quoted 5 lines · Mats

[snip]

Quoted 3 lines

My feeling is that the hypervisor and dom0 own the hardware and as such
all hardware fault management should reside there. So we

should never

Quoted 1 line
Quoted 1 line

deliver any form of #MC to a domU, nor should a poll of

MCA state from

Quoted 11 lines
Quoted 10 lines

a domU ever observe valid state (e.g, make the RDMSR return 0). So all handling, logging and diagnosis as well as hardware response actions
(such as to deploy an online spare chip-select) are controlled in the hypervisor/dom0 combination. That seems a consistent model - e.g.,
if a domU is migrated to another system it should not carry the diagnosis state of the original system across etc, since that belongs with
the one domain that cannot migrate.

Quoted 7 lines

I agree entirely with this.

Quoted 5 lines

But that is not to say that (I think at a future phase) domU should not
participate in a higher-level fault management function, at the direction
of the hypervisor/dom0 combo. For example if/when we can

isolate an

Quoted 1 line
Quoted 1 line

uncorrectable error to a single domU we could forward

such an event to

Quoted 1 line
Quoted 1 line

the affected domU if it has registered its

ability/interest in such

Quoted 2 lines
Quoted 2 lines

events. These won't be in the form of a faked #MC or anything, instead they'd be some form of synchronous trap

experienced when next

Quoted 3 lines
Quoted 3 lines

the affected domU context resumes on CPU. The intelligent domU handler
can then decide whether the domU must panic, whether it

could simply

Quoted 4 lines
Quoted 4 lines

kill the affected process etc. Those details are clearly sketchy, but the
idea is to up-level the communication to a domU to be more like "you're broken" rather than "here's a machine-level

hardware error for

Quoted 3 lines
Quoted 1 line

you to interpret and decide what to do with".

Yes, this makes much more sense than forwarding #MC, as the

guest would

Quoted 1 line

have a hard time to actually do anything really useful with

this. As far

Quoted 1 line

as I know, most uncorrectable errors are near enough

entirely fatal in

Quoted 2 lines

most commercial non-Enterprise OS's anyways - e.g. in Windows XP or Server 2K3, it always ends in a blue-screen - which is

hardly any better

Quoted 3 lines

than the guest being "humanely euthenazed" by Dom0.

I take it this would be some sort of hypercall (available

through the

Quoted 8 lines
Quoted 1 line

regular PV-driver interface for HVM guests) to say "Let me

know if I'm

Quoted 1 line

broken - trap on vector X".

For short, guests with a PV MCA driver will see a certain event (assuming the event mechanism will be used for the notification) and guests w/o a PV MCA driver will see a "General Protection Fault". Is that right?

Not sure if GP fault is the right thing for non-"MCA PV driver" domains. I think "just killing" the domain is the right thing to do.

We can't gurantee that a GP fault is actually going to "kill" the guest. Let's assume the code that ran on the guest was something along the lines of:

int some_function(...)
{
...

   try {
      ...
      /* Some code that does quite a lot of "random" processing that may cause, for example, GP fault */
	...
   } catch(Exception e) 
   {
	... 
	/* handles GP fault within the kernel code */
	...

}
}

Note that Windows kernel drivers are allowed to use the kernel exception handling, and ARE allowed to "allow" GP faults if they wish to do so. [Don't ask me why MS allows this, but that's the case, so we have to live with it].

I'm not sure if Linux, Solaris, *BSD, OS/2 or other OS's will allow "catching" a Kernel GP fault in a non-precise fashion (I know Linux has exception handling for EXACT positions in the code). But since at least one kernel DOES allow this, we can't be sure that a GPF will destroy the guest.

Second point to note is of course that if the guest is in user-mode when the GPF happens, then almost all OS's will just kill the application - and there's absolutely no reason to believe that the application running is necessarily where the actual memory problem is - it may be caused by memory scrubbing for example.

Whatever we do to the guest, it should be a "certain death", unless the kernel has told us "I can handle MCE's".

--
Mats

Quoted 30 lines
Quoted 6 lines

--
Mats

Quoted 2 lines

Gavin

Signature · 19 lines
AMD Saxony, Dresden, Germany
Operating System Research Center

Legal Information:
AMD Saxony Limited Liability Company & Co. KG
Sitz (Geschäftsanschrift):
   Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland
Registergericht Dresden: HRA 4896
vertretungsberechtigter Komplementär:
   AMD Saxony LLC (Sitz Wilmington, Delaware, USA)
Geschäftsführer der AMD Saxony LLC:
   Dr. Hans-R. Deppe, Thomas McCoy



_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xensource.com/xen-devel
#11 lore raw

On Friday 01 June 2007 10:55:28 Petersson, Mats wrote:

[snip]

Quoted 26 lines
Quoted 4 lines

For short, guests with a PV MCA driver will see a certain event (assuming the event mechanism will be used for the notification) and guests w/o a PV MCA driver will see a "General Protection Fault". Is that right?

Not sure if GP fault is the right thing for non-"MCA PV driver" domains. I think "just killing" the domain is the right thing to do.

We can't gurantee that a GP fault is actually going to "kill" the guest. Let's assume the code that ran on the guest was something along the lines of:

int some_function(...)

{
   ...

   try {
      ...
      /* Some code that does quite a lot of "random" processing that may
cause, for example, GP fault */ ...
   } catch(Exception e)
   {
	...
	/* handles GP fault within the kernel code */
	...
Quoted 8 lines

}
}

Note that Windows kernel drivers are allowed to use the kernel exception handling, and ARE allowed to "allow" GP faults if they wish to do so. [Don't ask me why MS allows this, but that's the case, so we have to live with it].

In that case, it will die sooner or later *after* consuming the data in error. That means, the guest continues to live for an unknown time...

Quoted 4 lines

I'm not sure if Linux, Solaris, *BSD, OS/2 or other OS's will allow "catching" a Kernel GP fault in a non-precise fashion (I know Linux has exception handling for EXACT positions in the code). But since at least one kernel DOES allow this, we can't be sure that a GPF will destroy the guest.

When Linux and *BSD see a GPF while they are in userspace, then they kill the process with a SIGSEGV. If they are in kernelspace, then they panic.

Quoted 8 lines

Second point to note is of course that if the guest is in user-mode when the GPF happens, then almost all OS's will just kill the application - and there's absolutely no reason to believe that the application running is necessarily where the actual memory problem is - it may be caused by memory scrubbing for example.

Whatever we do to the guest, it should be a "certain death", unless the kernel has told us "I can handle MCE's".

It is obvious that there is no absolute generic way to handle all sort of buggy guests. I vote for:

If DomU has a PV MCA driver use this or inject a GPF. Multiplexing all the MSR's related to emulate MCA/MCE for the guests is much more complex than just injecting a GPF - and slower.

Keir, what are your opinions on this thread?

Christoph

Signature · 12 lines
AMD Saxony, Dresden, Germany
Operating System Research Center

Legal Information:
AMD Saxony Limited Liability Company & Co. KG
Sitz (Geschäftsanschrift):
   Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland
Registergericht Dresden: HRA 4896
vertretungsberechtigter Komplementär:
   AMD Saxony LLC (Sitz Wilmington, Delaware, USA)
Geschäftsführer der AMD Saxony LLC:
   Dr. Hans-R. Deppe, Thomas McCoy
#12 lore raw
Quoted 53 lines

-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of Christoph Egger
Sent: 01 June 2007 10:28
To: [email protected]
Cc: Gavin Maltby; Keir Fraser
Subject: Re: [Xen-devel] RFC: MCA/MCE concept

On Friday 01 June 2007 10:55:28 Petersson, Mats wrote:

[snip]

Quoted 3 lines
Quoted 3 lines

For short, guests with a PV MCA driver will see a certain event (assuming the event mechanism will be used for the notification) and guests w/o a PV MCA driver will see a "General

Protection Fault".

Quoted 3 lines
Quoted 1 line

Is that right?

Not sure if GP fault is the right thing for non-"MCA PV

driver" domains. I

Quoted 3 lines

think "just killing" the domain is the right thing to do.

We can't gurantee that a GP fault is actually going to

"kill" the guest.

Quoted 1 line

Let's assume the code that ran on the guest was something

along the lines

Quoted 10 lines

of:

int some_function(...)

{
   ...

   try {
      ...
      /* Some code that does quite a lot of "random" 

processing that may

Quoted 11 lines

cause, for example, GP fault */ ...
} catch(Exception e)

   {
	...
	/* handles GP fault within the kernel code */
	...

}
}

Note that Windows kernel drivers are allowed to use the

kernel exception

Quoted 1 line

handling, and ARE allowed to "allow" GP faults if they wish

Quoted 8 lines

to do so.

Quoted 1 line

[Don't ask me why MS allows this, but that's the case, so

we have to live

Quoted 1 line

with it].

In that case, it will die sooner or later *after* consuming the data in error.
That means, the guest continues to live for an unknown time...

Yes. What I'm worried about is that if you have a "transient" or "few-bit" error in a rarely used, the guest may well live a LONG time with incorrect data and potentially not get it detected for quite some time again (say it's two bits have stuck to 0, and the data is then written back with the zero's there - next time we read it, no error, since the data has zero's in that location.

Also consider the case where one cell (or small block of cells) has gone bad, but it's only used by one single piece of code that is using this try/catch code? I know, this is probably relatively rare, but I'm still worried that it will "break" things...

Quoted 28 lines
Quoted 3 lines

I'm not sure if Linux, Solaris, *BSD, OS/2 or other OS's will allow "catching" a Kernel GP fault in a non-precise fashion (I

know Linux has

Quoted 1 line

exception handling for EXACT positions in the code). But

since at least one

Quoted 1 line

kernel DOES allow this, we can't be sure that a GPF will

destroy the guest.

When Linux and *BSD see a GPF while they are in userspace, then they kill
the process with a SIGSEGV. If they are in kernelspace, then they panic.

Quoted 1 line

Second point to note is of course that if the guest is in

user-mode when

Quoted 1 line

the GPF happens, then almost all OS's will just kill the

application - and

Quoted 1 line

there's absolutely no reason to believe that the

application running is

Quoted 1 line

necessarily where the actual memory problem is - it may be

caused by memory

Quoted 3 lines

scrubbing for example.

Whatever we do to the guest, it should be a "certain

death", unless the

Quoted 1 line

kernel has told us "I can handle MCE's".

Quoted 8 lines

It is obvious that there is no absolute generic way to handle all sort of
buggy guests. I vote for:

If DomU has a PV MCA driver use this or inject a GPF. Multiplexing all the MSR's related to emulate MCA/MCE for the guests is much
more complex than just injecting a GPF - and slower.

Emulating MCE to the guest wasn't my intended alternative suggestion. Instead, my idea was that if the guest hasn't registered a "PV MCE handler", we just immediately kill the domain as such - e.g similar to "domain_crash_synchronous()". Don't let the guest have any chance to "do something wrong" in the process - it's already broken, and letting it run any further will almost certainly not help matters. This may not be the prettiest solution, but then on the other hand, a "Windows blue-screen" or Linux "oops" saying GP fault happened at some random place in the guest isn't exactly helping the SysAdmin understand the problem either.

--
Mats

Quoted 29 lines

Keir, what are your opinions on this thread?

Christoph

Signature · 19 lines
AMD Saxony, Dresden, Germany
Operating System Research Center

Legal Information:
AMD Saxony Limited Liability Company & Co. KG
Sitz (Geschäftsanschrift):
   Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland
Registergericht Dresden: HRA 4896
vertretungsberechtigter Komplementär:
   AMD Saxony LLC (Sitz Wilmington, Delaware, USA)
Geschäftsführer der AMD Saxony LLC:
   Dr. Hans-R. Deppe, Thomas McCoy



_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xensource.com/xen-devel
#13 lore raw

Hi

On 06/01/07 10:48, Petersson, Mats wrote:
[cut]

Quoted 7 lines
Quoted 7 lines
Quoted 1 line

Note that Windows kernel drivers are allowed to use the

kernel exception

Quoted 1 line

handling, and ARE allowed to "allow" GP faults if they wish

to do so.

Quoted 1 line

[Don't ask me why MS allows this, but that's the case, so

we have to live

Quoted 1 line

with it].

Quoted 8 lines
Quoted 2 lines

In that case, it will die sooner or later *after* consuming the data in error. That means, the guest continues to live for an unknown time...

Yes. What I'm worried about is that if you have a "transient" or "few-bit" error in a rarely used, the guest may well live a LONG time with incorrect data and potentially not get it detected for quite some time again (say it's two bits have stuck to 0, and the data is then written back with the zero's there
- next time we read it, no error, since the data has zero's in that location.

I don't believe GP faults and uncorrectable errors really overlap that much. In a GP fault the extent of the damage is known - you tried to read from an address not in your address space, you lacked permissions for an operation etc. In an uncorrected error situation it is difficult to understand the bounds of the problem in that way - unless the hardware assists with data poisoning etc such errors may well be unconstrained and affect a wider area than just the bracket of code that caught a GP fault.

You can often ring-fence critical code sequences by inserting error barrier instructions before and after it. Those operations are usually very expensive (drain the pipeline or similar) and are suitable only in special places.

When running natively it is usually the "owner" of affected data that sees it bad in memory, eg from a read it made. In those cases we have the owner on cpu and can kill/signal it synchronously. There are times when the kernel may be shifting some data on behalf of the application owner (eg, copyin/copyout, shift network data etc) in which case we still have a handle on the real owner. If the access is from a scrub then we should not panic - just wait and see if the owner does indeed use the bad data at which time we take appropriate action.

With the virtualisation layer there is the additional case of the HV or dom0 performing operations on behalf of a guest, ie the HV may make the access that traps but it's own state is not affected.

CPU errors get still trickier. For example what do we do when we're told that while running guest A we displaced modified data from l2cache that had uncorrectable ECC? We have a physical address only, and no idea of who the data belongs to (guest A, a recently scheduled guest, or the HV?). Where cachelines are tagged with some form of context or guest ID you have a chance, provided that is reported in the error state.

Quoted 14 lines

Also consider the case where one cell (or small block of cells) has gone bad, but it's only used by one single piece of code that is using this try/catch code? I know, this is probably relatively rare, but I'm still worried that it will "break" things...

Quoted 10 lines
Quoted 2 lines

I'm not sure if Linux, Solaris, *BSD, OS/2 or other OS's will allow "catching" a Kernel GP fault in a non-precise fashion (I

know Linux has

Quoted 1 line

exception handling for EXACT positions in the code). But

since at least one

Quoted 1 line

kernel DOES allow this, we can't be sure that a GPF will

destroy the guest.

When Linux and *BSD see a GPF while they are in userspace, then they kill the process with a SIGSEGV. If they are in kernelspace, then they panic.

Solaris has some wrappers that can be applied, maybe at some expense to performance, to make protected accesses that will catch and survive various types of error including hardware errors, wild pointers etc.

Quoted 9 lines
Quoted 9 lines
Quoted 1 line

Second point to note is of course that if the guest is in

user-mode when

Quoted 1 line

the GPF happens, then almost all OS's will just kill the

application - and

Quoted 1 line

there's absolutely no reason to believe that the

application running is

Quoted 1 line

necessarily where the actual memory problem is - it may be

caused by memory

Quoted 1 line

scrubbing for example.

Yes, these are the myriad permutations I was alluding to above.

Quoted 2 lines
Quoted 2 lines
Quoted 1 line

Whatever we do to the guest, it should be a "certain

death", unless the

Yes, certain and instant death unless it is a PV guest that has registered the ability to deal with these more elegantly.

Quoted 6 lines
Quoted 6 lines
Quoted 1 line

kernel has told us "I can handle MCE's".

It is obvious that there is no absolute generic way to handle all sort of buggy guests. I vote for:

If DomU has a PV MCA driver use this or inject a GPF. Multiplexing all the MSR's related to emulate MCA/MCE for the guests is much more complex than just injecting a GPF - and slower.

Do we need to send the non-PV guest a signal of any kind to kill it? After all, we can stop it running any further instructions (and perhaps avoid the use of bad data) by deciding within the HV or dom0 simply to abort that guest. There is no loss to diagnosability since the HV/dom0 combination is doing that, anyway.

Quoted 7 lines

Emulating MCE to the guest wasn't my intended alternative suggestion. Instead,
my idea was that if the guest hasn't registered a "PV MCE handler", we just immediately kill the domain as such - e.g similar to "domain_crash_synchronous()". Don't let the guest have any chance to "do something wrong" in the process - it's
already broken, and letting it run any further will almost certainly not help matters.
This may not be the prettiest solution, but then on the other hand, a "Windows blue-screen"
or Linux "oops" saying GP fault happened at some random place in the guest isn't exactly
helping the SysAdmin understand the problem either.

Agreed - don't let the affected guest run one more instruction if we can. Sysadmins will learn to consult dom0 diagnostics to see if they explain any sudden guest deaths - no need, as you say, to splurge any raw error data to them.

Gavin

Quoted 32 lines

--
Mats

Quoted 28 lines

Keir, what are your opinions on this thread?

Christoph

Signature · 19 lines
AMD Saxony, Dresden, Germany
Operating System Research Center

Legal Information:
AMD Saxony Limited Liability Company & Co. KG
Sitz (Geschäftsanschrift):
   Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland
Registergericht Dresden: HRA 4896
vertretungsberechtigter Komplementär:
   AMD Saxony LLC (Sitz Wilmington, Delaware, USA)
Geschäftsführer der AMD Saxony LLC:
   Dr. Hans-R. Deppe, Thomas McCoy



_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xensource.com/xen-devel
Signature · 1 line
Gavin Maltby, Solaris Kernel Development.
#14 lore raw
Quoted 135 lines

-----Original Message-----
From: [email protected] [mailto:[email protected]]
Sent: 01 June 2007 11:57
To: Petersson, Mats
Cc: Egger, Christoph; [email protected]; Keir Fraser
Subject: Re: [Xen-devel] RFC: MCA/MCE concept

Hi

On 06/01/07 10:48, Petersson, Mats wrote:
[cut]

Quoted 4 lines
Quoted 4 lines
Quoted 1 line

Note that Windows kernel drivers are allowed to use the

kernel exception

Quoted 1 line

handling, and ARE allowed to "allow" GP faults if they wish

to do so.

Quoted 8 lines
Quoted 6 lines
Quoted 1 line

[Don't ask me why MS allows this, but that's the case, so

we have to live

Quoted 1 line

with it].

In that case, it will die sooner or later *after* consuming the data in error.
That means, the guest continues to live for an unknown time...

Yes. What I'm worried about is that if you have a

"transient" or "few-bit"

Quoted 1 line

error in a rarely used, the guest may well live a LONG

time with incorrect

Quoted 1 line

data and potentially not get it detected for quite some

time again (say it's

Quoted 1 line

two bits have stuck to 0, and the data is then written back

with the zero's there

Quoted 1 line

- next time we read it, no error, since the data has

zero's in that location.

I don't believe GP faults and uncorrectable errors really overlap that much.
In a GP fault the extent of the damage is known - you tried to read from
an address not in your address space, you lacked permissions for an operation
etc. In an uncorrected error situation it is difficult to understand the
bounds of the problem in that way - unless the hardware assists with data poisoning etc such errors may well be unconstrained and affect a wider area than just the bracket of code that caught a GP fault.

You can often ring-fence critical code sequences by inserting error barrier instructions before and after it. Those operations are usually very expensive (drain the pipeline or similar) and are suitable only in special places.

When running natively it is usually the "owner" of affected data that sees it bad in memory, eg from a read it made. In those cases we have the owner on cpu and can kill/signal it synchronously. There are times when the kernel may be shifting some data on behalf of the application owner (eg, copyin/copyout, shift network data etc) in which case we still have a handle on the real owner. If the access is from a scrub then we should not panic - just wait and see if the owner does indeed use the bad data at which time we take appropriate action.

With the virtualisation layer there is the additional case of the HV or
dom0 performing operations on behalf of a guest, ie the HV may make the
access that traps but it's own state is not affected.

CPU errors get still trickier. For example what do we do when we're told that
while running guest A we displaced modified data from l2cache that had uncorrectable ECC? We have a physical address only, and no idea of who the
data belongs to (guest A, a recently scheduled guest, or the HV?). Where
cachelines are tagged with some form of context or guest ID you have a chance, provided that is reported in the error state.

Quoted 1 line

Also consider the case where one cell (or small block of

cells) has gone bad,

Quoted 1 line

but it's only used by one single piece of code that is

using this try/catch code?

Quoted 1 line

I know, this is probably relatively rare, but I'm still

worried that it will "break" things...

Quoted 1 line
Quoted 1 line
Quoted 1 line

I'm not sure if Linux, Solaris, *BSD, OS/2 or other OS's

will allow

Quoted 11 lines
Quoted 11 lines
Quoted 1 line

"catching" a Kernel GP fault in a non-precise fashion (I

know Linux has

Quoted 1 line

exception handling for EXACT positions in the code). But

since at least one

Quoted 1 line

kernel DOES allow this, we can't be sure that a GPF will

destroy the guest.

When Linux and *BSD see a GPF while they are in userspace, then they kill
the process with a SIGSEGV. If they are in kernelspace, then they panic.

Solaris has some wrappers that can be applied, maybe at some expense to
performance, to make protected accesses that will catch and survive various types of error including hardware errors, wild pointers etc.

Quoted 9 lines
Quoted 9 lines
Quoted 1 line

Second point to note is of course that if the guest is in

user-mode when

Quoted 1 line

the GPF happens, then almost all OS's will just kill the

application - and

Quoted 1 line

there's absolutely no reason to believe that the

application running is

Quoted 1 line

necessarily where the actual memory problem is - it may be

caused by memory

Quoted 1 line

scrubbing for example.

Yes, these are the myriad permutations I was alluding to above.

Quoted 2 lines
Quoted 2 lines
Quoted 1 line

Whatever we do to the guest, it should be a "certain

death", unless the

Yes, certain and instant death unless it is a PV guest that has registered
the ability to deal with these more elegantly.

Quoted 9 lines
Quoted 9 lines
Quoted 1 line

kernel has told us "I can handle MCE's".

It is obvious that there is no absolute generic way to handle all sort of
buggy guests. I vote for:

If DomU has a PV MCA driver use this or inject a GPF. Multiplexing all the MSR's related to emulate MCA/MCE for the guests is much
more complex than just injecting a GPF - and slower.

Quoted 6 lines

Do we need to send the non-PV guest a signal of any kind to kill it? After all, we can stop it running any further instructions (and perhaps
avoid the use of bad data) by deciding within the HV or dom0 simply to abort that guest. There is no loss to diagnosability since the HV/dom0 combination is doing that, anyway.

No, HV can "kill" a guest without notifying the guest - in worst case, it may need to pause the physical CPU that may still be running on the guest (e.g. we have multiple CPU's, one of them got "bad data", but other CPU's are still processing stuff). But the pausing of the CPU is a "in hypervisor" function, so still no need to tell the guest anything - just "Bang, you're dead" type thing.

Quoted 14 lines
Quoted 2 lines

Emulating MCE to the guest wasn't my intended alternative

suggestion. Instead,

Quoted 1 line

my idea was that if the guest hasn't registered a "PV MCE

handler", we just

Quoted 1 line

immediately kill the domain as such - e.g similar to

"domain_crash_synchronous()".

Quoted 1 line

Don't let the guest have any chance to "do something

wrong" in the process - it's

Quoted 1 line

already broken, and letting it run any further will almost

certainly not help matters.

Quoted 1 line

This may not be the prettiest solution, but then on the

other hand, a "Windows blue-screen"

Quoted 1 line

or Linux "oops" saying GP fault happened at some random

Quoted 8 lines

place in the guest isn't exactly

Quoted 1 line

helping the SysAdmin understand the problem either.

Agreed - don't let the affected guest run one more instruction if we can. Sysadmins
will learn to consult dom0 diagnostics to see if they explain any sudden guest deaths -
no need, as you say, to splurge any raw error data to them.

Exactly, particularly when it's bogus raw error data, that isn't actually caused by the original problem.

--
Mats

Quoted 41 lines

Gavin

Quoted 32 lines

--
Mats

Quoted 28 lines

Keir, what are your opinions on this thread?

Christoph

Signature · 19 lines
AMD Saxony, Dresden, Germany
Operating System Research Center

Legal Information:
AMD Saxony Limited Liability Company & Co. KG
Sitz (Geschäftsanschrift):
   Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland
Registergericht Dresden: HRA 4896
vertretungsberechtigter Komplementär:
   AMD Saxony LLC (Sitz Wilmington, Delaware, USA)
Geschäftsführer der AMD Saxony LLC:
   Dr. Hans-R. Deppe, Thomas McCoy



_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xensource.com/xen-devel
Signature · 1 line
Gavin Maltby, Solaris Kernel Development.
#15 lore raw
In reply to Christoph Egger

Hi,

Quoted 10 lines · Christoph Egger
Quoted 9 lines · On Wednesday 30 May 2007 10:49:40 Jan Beulich wrote:
Quoted 9 lines
Quoted 1 line
Quoted 1 line

"Christoph Egger" <[email protected]> 30.05.07 09:45 >>>

Quoted 7 lines · On Wednesday 30 May 2007 09:19:12 Jan Beulich wrote:
Quoted 7 lines

case I) - Xen reveives a MCE from the CPU

1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose

[rest cut]

For the hypervisor to dom0 communication that 2a) above refers to I think we need to agree on two aspects: what form the notification event will take, and what error telemetry data and additional information will be provided by the hypervisor for dom0 to chew on for statistical and diagnosis purposes.

For the first I've assumed so far that an event channel notification of the MCA event will suffice; as long as the hypervisor only polls for correctable MCA errors at a low-frequency rate (currently 15s interval) there is no danger of spamming that single notification. On receipt of the notification the event handler will need to suck some event data out of somewhere - uncertain which somewhere would be best?

We should standardize both the format and the content of this event data. The following is just to get the conversation started in this area.

Content first. Obviously we need the raw MCA register content - MCi_STATUS, MCi_ADDR, MCi_MISC. We also need know which MCA detector bank made the observation, so we need to include some indication of which chip (where I use "chip" to coincide with "socket"), core on that chip, and MCA bank number the telemetry came from. I think I am correct in saying that hyperthreaded CPUs do not have any MCA banks per-thread, but we may want to allow for that future possibility (I know, for instance, that some SPARC cpus have error state for each hardware thread).

Such specification of error detector information clearly requires some namespace specification. For example if the detector identifier could naturally come out of Xen as a (chip, core, thread, bank) there needs to be a clear understanding of how chips, cores etc are numbered in Xen and how dom0 that matches with how the dom0 OS has numbered these things. If instead the detector identifier were something like a (physical-cpu, bank) using the Xen physical-cpu enumeration then dom0 may need a mechanism to resolve this into chip etc info - you can't just work with physical cpus since, for example, a chip-shared L3 cache spans multiple physical cpus.

We should also allow for additional model-specific error telemetry that may be available and relevant - I know that will be necessary for some upcoming x86 cpu models. We should probably avoid adding "cooked" content to this error event payload - such cooking of the raw data is much more easily performed in dom0 (the example I'm thinking of here is physical address to memory location translation).

In terms of the form of the error event data, the simplest but also the dumbest would be a binary structure passed from hypervisor to dom0:

struct mca_error_data_ver1 {
	uint8_t version;	/* structure version */
	uint64_t status;
	uint64_t addr;
	uint64_t misc;
	uint16_t chip;
	uint16_t core;
	uint16_t bank;
	...
};

That is easily passed around and can be extended by versioning. A more self-describing and naturally extensible approach would be to parcel the error data in some form of name-type-value list. That's what we do in the corresponding kernel->userland error code in Solaris; the downside is that the supporting libnvpair library is not tiny and likely not the sort of footprint to include in a hypervisor. Perhaps some cut-down form would do.

Thoughts?

Gavin

#16 lore raw
Quoted 15 lines · On Monday 04 June 2007 18:16:56 Gavin Maltby wrote:

Hi,

Quoted 11 lines · Christoph Egger
Quoted 10 lines · On Wednesday 30 May 2007 10:49:40 Jan Beulich wrote:
Quoted 10 lines
Quoted 1 line
Quoted 1 line

"Christoph Egger" <[email protected]> 30.05.07 09:45 >>>

Quoted 7 lines · On Wednesday 30 May 2007 09:19:12 Jan Beulich wrote:
Quoted 7 lines

case I) - Xen reveives a MCE from the CPU

1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose

Quoted 7 lines

[rest cut]

For the hypervisor to dom0 communication that 2a) above refers to I think we need to agree on two aspects: what form the notification event will take, and what error telemetry data and additional information will be provided by the hypervisor for dom0 to chew on for statistical and diagnosis purposes.

Additionally, the hypervisor must be able to notify domU that has a PV MCA driver.

Quoted 4 lines

For the first I've assumed so far that an event channel notification of the MCA event will suffice; as long as the hypervisor only polls for correctable MCA errors at a low-frequency rate (currently 15s interval) there is no danger of spamming that single notification.

Why polling?

Quoted 8 lines

On receipt of the notification the event handler will need to suck some event data out of somewhere - uncertain which somewhere would be best?

We should standardize both the format and the content of this event data. The following is just to get the conversation started in this area.

Quoted 9 lines

Content first. Obviously we need the raw MCA register content - MCi_STATUS, MCi_ADDR, MCi_MISC. We also need know which MCA detector bank made the observation, so we need to include some indication of which chip (where I use "chip" to coincide with "socket"), core on that chip, and MCA bank number the telemetry came from. I think I am correct in saying that hyperthreaded CPUs do not have any MCA banks per-thread, but we may want to allow for that future possibility (I know, for instance, that some SPARC cpus have error state for each hardware thread).

And we need the domain and the domain's vcpu to identify who is impacted.

Quoted 11 lines

We should also allow for additional model-specific error telemetry that may be available and relevant - I know that will be necessary for some upcoming x86 cpu models. We should probably avoid adding "cooked" content to this error event payload - such cooking of the raw data is much more easily performed in dom0 (the example I'm thinking of here is physical address to memory location translation).

In terms of the form of the error event data, the simplest but also the dumbest would be a binary structure passed from hypervisor to dom0:

struct mca_error_data_ver1 {
uint8_t version; /* structure version */
uint64_t mc_status;
uint64_t mc_addr;
uint64_t mc_misc;
uint16_t mc_chip;
uint16_t mc_core;

 	uint16_t mc_bank;
        uint16_t domid;
        uint16_t vcpu_id;

...
};

Quoted 7 lines

That is easily passed around and can be extended by versioning. A more self-describing and naturally extensible approach would be to parcel the error data in some form of name-type-value list. That's what we do in the corresponding kernel->userland error code in Solaris; the downside is that the supporting libnvpair library is not tiny and likely not the sort of footprint to include in a hypervisor. Perhaps some cut-down form would do.

In the public xen.h header is a VIRQ_DOM_EXC defined, which seems to be appropriate for an NMI event.
There are two functions to send VIRQs: send_guest_vcpu_virq() and send_guest_global_virq().

However, VIRQ_DOM_EXC is not properly implemented:
All virtual interrupts are maskable. We definitely need
an event that guarantees to immediately interrupts the guest, no matter if this is Dom0 or DomU and whatever they are doing.

And VIRQ_DOM_EXC is explicitely reserved for Dom0. Maybe
we should introduce a VIRQ_MCA as a special NMI event for both Dom0 and DomU?

Christoph

Signature · 12 lines
AMD Saxony, Dresden, Germany
Operating System Research Center

Legal Information:
AMD Saxony Limited Liability Company & Co. KG
Sitz (Geschäftsanschrift):
   Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland
Registergericht Dresden: HRA 4896
vertretungsberechtigter Komplementär:
   AMD Saxony LLC (Sitz Wilmington, Delaware, USA)
Geschäftsführer der AMD Saxony LLC:
   Dr. Hans-R. Deppe, Thomas McCoy
#17 lore raw

Hi,

Quoted 16 lines · Christoph Egger
Quoted 15 lines · On Monday 04 June 2007 18:16:56 Gavin Maltby wrote:

Hi,

Quoted 10 lines · Christoph Egger
Quoted 9 lines · On Wednesday 30 May 2007 10:49:40 Jan Beulich wrote:
Quoted 9 lines
Quoted 1 line
Quoted 1 line

"Christoph Egger" <[email protected]> 30.05.07 09:45 >>>

Quoted 7 lines · On Wednesday 30 May 2007 09:19:12 Jan Beulich wrote:
Quoted 7 lines

case I) - Xen reveives a MCE from the CPU

1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose

[rest cut]

Quoted 8 lines
Quoted 5 lines

For the hypervisor to dom0 communication that 2a) above refers to I think we need to agree on two aspects: what form the notification event will take, and what error telemetry data and additional information will be provided by the hypervisor for dom0 to chew on for statistical and diagnosis purposes.

Additionally, the hypervisor must be able to notify domU that has a PV MCA driver.

Yes, forgot that; although I guess I view that most likely as a future phase.

Quoted 6 lines
Quoted 4 lines

For the first I've assumed so far that an event channel notification of the MCA event will suffice; as long as the hypervisor only polls for correctable MCA errors at a low-frequency rate (currently 15s interval) there is no danger of spamming that single notification.

Why polling?

Polling for correctable errors, but #MC as usual for others. Setting MCi_CTL bits for correctable errors does not produce a machine check, so polling is the only approach unless one sets additional (and undocumented, certainly for AMD chips) config bits. What I was getting at here is that polling at largish intervals for correctables is the correct approach - trapping for them or polling at a high-frequency is bad because in cases where you have some form of solid correctable error (say a single bad pin in a dimm socket affecting one or two ranks of that dimm but never able to produce a UE) the trap handling and diagnosis software consume the machine and things make little useful forward progress.

Quoted 18 lines
Quoted 8 lines

On receipt of the notification the event handler will need to suck some event data out of somewhere - uncertain which somewhere would be best?

We should standardize both the format and the content of this event data. The following is just to get the conversation started in this area.

Quoted 9 lines

Content first. Obviously we need the raw MCA register content - MCi_STATUS, MCi_ADDR, MCi_MISC. We also need know which MCA detector bank made the observation, so we need to include some indication of which chip (where I use "chip" to coincide with "socket"), core on that chip, and MCA bank number the telemetry came from. I think I am correct in saying that hyperthreaded CPUs do not have any MCA banks per-thread, but we may want to allow for that future possibility (I know, for instance, that some SPARC cpus have error state for each hardware thread).

Quoted 2 lines

And we need the domain and the domain's vcpu to identify who is impacted.

Yes, the domain ID. I'm not sure we need the vcpu id if we instead present some physical identifiers such as chip, core number etc (and have the namespaces well-defined). If we don't present those the vcpu in the payload and some external method to resolve that to physical components. Since errors correlate to physical components it would, I think, be nicer to report detector info in some physical sense.

As regards a vcpu to physical translation, I didn't think there was any fixed mapping (or certainly any mapping that a dom0 should interpret and rely on). For example if we have two physical cores but choose to present 32 vcpus to domain I don't believe there is anything to say that 0-15 map always run on physical core 0?

Quoted 36 lines
Quoted 11 lines

We should also allow for additional model-specific error telemetry that may be available and relevant - I know that will be necessary for some upcoming x86 cpu models. We should probably avoid adding "cooked" content to this error event payload - such cooking of the raw data is much more easily performed in dom0 (the example I'm thinking of here is physical address to memory location translation).

In terms of the form of the error event data, the simplest but also the dumbest would be a binary structure passed from hypervisor to dom0:

struct mca_error_data_ver1 {

(quoted diff) +0 -0
 	uint8_t version;	/* structure version */
 	uint64_t mc_status;
 	uint64_t mc_addr;
 	uint64_t mc_misc;
 	uint16_t mc_chip;
 	uint16_t mc_core;
 	uint16_t mc_bank;
        uint16_t domid;
        uint16_t vcpu_id;
...

};

Quoted 7 lines

That is easily passed around and can be extended by versioning. A more self-describing and naturally extensible approach would be to parcel the error data in some form of name-type-value list. That's what we do in the corresponding kernel->userland error code in Solaris; the downside is that the supporting libnvpair library is not tiny and likely not the sort of footprint to include in a hypervisor. Perhaps some cut-down form would do.

In the public xen.h header is a VIRQ_DOM_EXC defined, which seems
to be appropriate for an NMI event.
There are two functions to send VIRQs: send_guest_vcpu_virq() and send_guest_global_virq().

Quoted 7 lines

However, VIRQ_DOM_EXC is not properly implemented:
All virtual interrupts are maskable. We definitely need
an event that guarantees to immediately interrupts the guest, no matter if this is Dom0 or DomU and whatever they are doing.

And VIRQ_DOM_EXC is explicitely reserved for Dom0. Maybe
we should introduce a VIRQ_MCA as a special NMI event for both Dom0 and DomU?

Sounds like it may be necessary. I don't know this mechanism very well so I'll go and do some reading (after a big long unrelated codereview).

Cheers

Gavin

#18 lore raw
Quoted 27 lines · On Wednesday 06 June 2007 12:35:15 Gavin Maltby wrote:

Hi,

Quoted 24 lines · Christoph Egger
Quoted 22 lines · On Monday 04 June 2007 18:16:56 Gavin Maltby wrote:

Hi,

Quoted 11 lines · Christoph Egger
Quoted 10 lines · On Wednesday 30 May 2007 10:49:40 Jan Beulich wrote:
Quoted 10 lines
Quoted 1 line
Quoted 1 line

"Christoph Egger" <[email protected]> 30.05.07 09:45 >>>

Quoted 7 lines · On Wednesday 30 May 2007 09:19:12 Jan Beulich wrote:
Quoted 7 lines

case I) - Xen reveives a MCE from the CPU

1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose

[rest cut]

For the hypervisor to dom0 communication that 2a) above refers to I think we need to agree on two aspects: what form the notification event will take, and what error telemetry data and additional information will be provided by the hypervisor for dom0 to chew on for statistical and diagnosis purposes.

Quoted 5 lines
Quoted 2 lines

Additionally, the hypervisor must be able to notify domU that has a PV MCA driver.

Yes, forgot that; although I guess I view that most likely as a future phase.

Yes, but ignoring this can lead to a design that is bad for DomU and requires a re-design in the worst case.

Quoted 7 lines
Quoted 6 lines
Quoted 4 lines

For the first I've assumed so far that an event channel notification of the MCA event will suffice; as long as the hypervisor only polls for correctable MCA errors at a low-frequency rate (currently 15s interval) there is no danger of spamming that single notification.

Why polling?

Quoted 11 lines

Polling for correctable errors, but #MC as usual for others. Setting MCi_CTL bits for correctable errors does not produce a machine check, so polling is the only approach unless one sets additional (and undocumented, certainly for AMD chips) config bits. What I was getting at here is that polling at largish intervals for correctables is the correct approach - trapping for them or polling at a high-frequency is bad because in cases where you have some form of solid correctable error (say a single bad pin in a dimm socket affecting one or two ranks of that dimm but never able to produce a UE) the trap handling and diagnosis software consume the machine and things make little useful forward progress.

I still don't see, why #MC for all kind of errors is bad.

Quoted 21 lines
Quoted 18 lines
Quoted 8 lines

On receipt of the notification the event handler will need to suck some event data out of somewhere - uncertain which somewhere would be best?

We should standardize both the format and the content of this event data. The following is just to get the conversation started in this area.

Quoted 9 lines

Content first. Obviously we need the raw MCA register content - MCi_STATUS, MCi_ADDR, MCi_MISC. We also need know which MCA detector bank made the observation, so we need to include some indication of which chip (where I use "chip" to coincide with "socket"), core on that chip, and MCA bank number the telemetry came from. I think I am correct in saying that hyperthreaded CPUs do not have any MCA banks per-thread, but we may want to allow for that future possibility (I know, for instance, that some SPARC cpus have error state for each hardware thread).

Quoted 2 lines

And we need the domain and the domain's vcpu to identify who is impacted.

Quoted 6 lines

Yes, the domain ID. I'm not sure we need the vcpu id if we instead present some physical identifiers such as chip, core number etc (and have the namespaces well-defined). If we don't present those the vcpu in the payload and some external method to resolve that to physical components. Since errors correlate to physical components it would, I think, be nicer to report detector info in some physical sense.

The vcpu is more interesting for the domU than for dom0. See below.

Quoted 48 lines

As regards a vcpu to physical translation, I didn't think there was any fixed mapping (or certainly any mapping that a dom0 should interpret and rely on). For example if we have two physical cores but choose to present 32 vcpus to domain I don't believe there is anything to say that 0-15 map always run on physical core 0?

Quoted 42 lines
Quoted 10 lines

We should also allow for additional model-specific error telemetry that may be available and relevant - I know that will be necessary for some upcoming x86 cpu models. We should probably avoid adding "cooked" content to this error event payload - such cooking of the raw data is much more easily performed in dom0 (the example I'm thinking of here is physical address to memory location translation).

In terms of the form of the error event data, the simplest but also the dumbest would be a binary structure passed from hypervisor to dom0:

struct mca_error_data_ver1 {

(quoted diff) +0 -0
 	uint8_t version;	/* structure version */
 	uint64_t mc_status;
 	uint64_t mc_addr;
 	uint64_t mc_misc;
 	uint16_t mc_chip;
 	uint16_t mc_core;
 	uint16_t mc_bank;
        uint16_t domid;
        uint16_t vcpu_id;
...

};

Quoted 7 lines

That is easily passed around and can be extended by versioning. A more self-describing and naturally extensible approach would be to parcel the error data in some form of name-type-value list. That's what we do in the corresponding kernel->userland error code in Solaris; the downside is that the supporting libnvpair library is not tiny and likely not the sort of footprint to include in a hypervisor. Perhaps some cut-down form would do.

In the public xen.h header is a VIRQ_DOM_EXC defined, which seems to be appropriate for an NMI event.
There are two functions to send VIRQs: send_guest_vcpu_virq() and send_guest_global_virq().

However, VIRQ_DOM_EXC is not properly implemented:
All virtual interrupts are maskable. We definitely need
an event that guarantees to immediately interrupts the guest, no matter if this is Dom0 or DomU and whatever they are doing.

Quoted 6 lines
Quoted 3 lines

And VIRQ_DOM_EXC is explicitely reserved for Dom0. Maybe
we should introduce a VIRQ_MCA as a special NMI event for both Dom0 and DomU?

Sounds like it may be necessary. I don't know this mechanism very well so I'll go and do some reading (after a big long unrelated codereview).

After some code reading I found a nmi_pending, nmi_masked and nmi_addr in struct vcpu in xen/include/xen/sched.h. xen/include/xen/nmi.h is also of interest. The implementation is in xen/common/kernel.c.
There is only one callback per vcpu allowed and only Dom0 can register an NMI. So the guests NMI handler must multiplex several nmi handlers - at least for Dom0 (MCA + watchdog timer). It's fine with me to allow DomUs to only register the MCA NMI.

To inform domU (having a PV MCA driver), they must be able to register an NMI callback as well. To allow this, struct vcpu_info in the PUBLIC xen.h also needs nmi_pending and nmi_addr.

Keir: How do you feel about all this? Is this the right way or do you see things that should be done in a different way?

Christoph

Signature · 12 lines
AMD Saxony, Dresden, Germany
Operating System Research Center

Legal Information:
AMD Saxony Limited Liability Company & Co. KG
Sitz (Geschäftsanschrift):
   Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland
Registergericht Dresden: HRA 4896
vertretungsberechtigter Komplementär:
   AMD Saxony LLC (Sitz Wilmington, Delaware, USA)
Geschäftsführer der AMD Saxony LLC:
   Dr. Hans-R. Deppe, Thomas McCoy
#19 lore raw

Hi,

Quoted 17 lines · Christoph Egger
Quoted 5 lines
Quoted 5 lines
Quoted 4 lines

For the first I've assumed so far that an event channel notification of the MCA event will suffice; as long as the hypervisor only polls for correctable MCA errors at a low-frequency rate (currently 15s interval) there is no danger of spamming that single notification.

Why polling?

Quoted 11 lines

Polling for correctable errors, but #MC as usual for others. Setting MCi_CTL bits for correctable errors does not produce a machine check, so polling is the only approach unless one sets additional (and undocumented, certainly for AMD chips) config bits. What I was getting at here is that polling at largish intervals for correctables is the correct approach - trapping for them or polling at a high-frequency is bad because in cases where you have some form of solid correctable error (say a single bad pin in a dimm socket affecting one or two ranks of that dimm but never able to produce a UE) the trap handling and diagnosis software consume the machine and things make little useful forward progress.

Quoted 1 line

I still don't see, why #MC for all kind of errors is bad.

I'm talking about whether the hypervisor takes a machine check for an error or polls for it. We do not want #MC for correctable errors stopping the hypervisor from making progress. And if the hypervisor poll interval was to small a solid error would again keep the hypervisor busy producing (mostly/all duplicate) error telemetry and the diagnosis code in dom0 would burn cpu cycles, too.

How errors observed by the hypervisor, be they from #MC or from a poll, are propogated to the domains is unimportant from this point of view - e.g., if we decide to take error telemetry discovered via a poll in the hypervisor and propogate it to the domain pretending it is undistinguishable from a machine check that will not hurt or limit the domain processing.

An untested design I had in mind, unashamedly influenced by what we do in Solaris, was to have some common memory shared between hypervisor and domain into which the hypervisor produces error telemetry and the domain consumes that telemetry. Producing and consuming is lockless using compare-and-swap. There are two queues in this shared memory - one for uncorrectable error telemetry and one for correctable error telemetry. When the domain gets whatever event to notify it of telemetry for processing it processes the queues; the event would be synchronous for uncorrectable errors (ie, domain must process the telemetry right now) or asynchronous in the case of correctable errors (process when convenient). The separation of CE and UE queues stops CEs from flooding the more important UE events (you can always drop CEs if there is no more space, but you can never drop UEs).

[cut]

Quoted 1 line

After some code reading I found a nmi_pending, nmi_masked and nmi_addr in

[cut]

Still chewing on that ...

Cheers

Gavin

#20 lore raw
Quoted 39 lines · On Wednesday 06 June 2007 14:25:26 Gavin Maltby wrote:

Hi,

Quoted 19 lines · Christoph Egger
Quoted 7 lines
Quoted 6 lines
Quoted 4 lines

For the first I've assumed so far that an event channel notification of the MCA event will suffice; as long as the hypervisor only polls for correctable MCA errors at a low-frequency rate (currently 15s interval) there is no danger of spamming that single notification.

Why polling?

Quoted 11 lines

Polling for correctable errors, but #MC as usual for others. Setting MCi_CTL bits for correctable errors does not produce a machine check, so polling is the only approach unless one sets additional (and undocumented, certainly for AMD chips) config bits. What I was getting at here is that polling at largish intervals for correctables is the correct approach - trapping for them or polling at a high-frequency is bad because in cases where you have some form of solid correctable error (say a single bad pin in a dimm socket affecting one or two ranks of that dimm but never able to produce a UE) the trap handling and diagnosis software consume the machine and things make little useful forward progress.

Quoted 1 line

I still don't see, why #MC for all kind of errors is bad.

I'm talking about whether the hypervisor takes a machine check for an error or polls for it. We do not want #MC for correctable errors stopping the hypervisor from making progress. And if the hypervisor poll interval was to small a solid error would again keep the hypervisor busy producing (mostly/all duplicate) error telemetry and the diagnosis code in dom0 would burn cpu cycles, too.

How errors observed by the hypervisor, be they from #MC or from a poll, are propogated to the domains is unimportant from this point of view - e.g., if we decide to take error telemetry discovered via a poll in the hypervisor and propogate it to the domain pretending it is undistinguishable from a machine check that will not hurt or limit the domain processing.

Quoted 4 lines

An untested design I had in mind, unashamedly influenced by what we do in Solaris, was to have some common memory shared between hypervisor and domain into which the hypervisor produces error telemetry and the domain consumes that telemetry.

That is the struct vcpu_info in the PUBLIC xen.h. It is accessable in the hypervisor as well as in the guest.

Quoted 11 lines

Producing and consuming is lockless using compare-and-swap. There are two queues in this shared memory - one for uncorrectable error telemetry and one for correctable error telemetry. When the domain gets whatever event to notify it of telemetry for processing it processes the queues; the event would be synchronous for uncorrectable errors (ie, domain must process the telemetry right now) or asynchronous in the case of correctable errors (process when convenient). The separation of CE and UE queues stops CEs from flooding the more important UE events (you can always drop CEs if there is no more space, but you can never drop UEs).

So we use the asynchronous event mechanism VIRQ_DOM_EXC to report correctable errors to the Dom0 and the nmi stuff for uncorrectable errors to Dom0 and DomU, right?

The fact that VIRQ_DOM_EXC is for Dom0 only doesn't hurt here, since we never report CEs to DomUs.

Quoted 7 lines

[cut]

Quoted 1 line

After some code reading I found a nmi_pending, nmi_masked and nmi_addr in

[cut]

Still chewing on that ...

Christoph

Signature · 12 lines
AMD Saxony, Dresden, Germany
Operating System Research Center

Legal Information:
AMD Saxony Limited Liability Company & Co. KG
Sitz (Geschäftsanschrift):
   Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland
Registergericht Dresden: HRA 4896
vertretungsberechtigter Komplementär:
   AMD Saxony LLC (Sitz Wilmington, Delaware, USA)
Geschäftsführer der AMD Saxony LLC:
   Dr. Hans-R. Deppe, Thomas McCoy
#21 lore raw
In reply to Christoph Egger
Quoted 17 lines · Christoph Egger
Quoted 4 lines · On Monday 04 June 2007 18:16:56 Gavin Maltby wrote:

In terms of the form of the error event data, the simplest but also the dumbest would be a binary structure passed from hypervisor to dom0:

struct mca_error_data_ver1 {

(quoted diff) +0 -0
 	uint8_t version;	/* structure version */
 	uint64_t mc_status;
 	uint64_t mc_addr;
 	uint64_t mc_misc;
 	uint16_t mc_chip;
 	uint16_t mc_core;
 	uint16_t mc_bank;
        uint16_t domid;
        uint16_t vcpu_id;
...
Quoted 1 line

};

Since there are multiple MCA detector banks, and more than one may have logged a valid error, we need to think about communicating all the bank error telemetry. This should also allow for there being varying numbers of MCA banks in different proccessor types. So something like

struct {
	uint8_t version;
	uint8_t nbanks;
	uint16_t flags;
	uint16_t domid;
	uint16_t vcpud_id; /* if meaningful? */
	uint8_t chipid;
	uint8_t coreid;
	uint64_t mcg_status;
	struct {
		mc_status;
		mc_addr;
		mc_misc;
	} bank[1];
};

The bank array is actually sized as per nbanks.

I've added mcg_status and flags. The latter I'd like to use for indicators such as "this error data was artificially injected" etc.

Gavin

#22 lore raw
Quoted 41 lines · On Thursday 14 June 2007 13:59:12 Gavin Maltby wrote:
Quoted 16 lines · Christoph Egger
Quoted 3 lines · On Monday 04 June 2007 18:16:56 Gavin Maltby wrote:

In terms of the form of the error event data, the simplest but also the dumbest would be a binary structure passed from hypervisor to dom0:

struct mca_error_data_ver1 {

(quoted diff) +0 -0
 	uint8_t version;	/* structure version */
 	uint64_t mc_status;
 	uint64_t mc_addr;
 	uint64_t mc_misc;
 	uint16_t mc_chip;
 	uint16_t mc_core;
 	uint16_t mc_bank;
        uint16_t domid;
        uint16_t vcpu_id;
...
Quoted 1 line

};

Since there are multiple MCA detector banks, and more than one may have logged a valid error, we need to think about communicating all the bank error telemetry. This should also allow for there being varying numbers of MCA banks in different proccessor types. So something like

struct {
	uint8_t version;
	uint8_t nbanks;
	uint16_t flags;
	uint16_t domid;
	uint16_t vcpud_id; /* if meaningful? */
	uint8_t chipid;
	uint8_t coreid;
	uint64_t mcg_status;
	struct {
		mc_status;
		mc_addr;
		mc_misc;
	} bank[1];
};
Quoted 5 lines

The bank array is actually sized as per nbanks.

I've added mcg_status and flags. The latter I'd like to use for indicators such as "this error data was artificially injected" etc.

Here is my proposal for a real exensible event structure:

#define MCA_TYPE_COMMON 0
#define MCA_TYPE_BANK 1
#define MCA_TYPE_ALLBANKS 2
...

#define MCA_COMMON \
size_t size; /* size of this struct in bytes */ uint32_t type; /* structure type */ uint16_t domid;
uint8_t chipid;
uint8_t coreid;
uint64_t mcg_status; /* global status */

The base structure:

struct mca_event {
     MCA_COMMON;
};

The specific structs:

struct mca_event_bank {
MCA_COMMON;

uint16_t vcpu_id;
uint16_t mc_bank;
uint64_t mc_status;
uint64_t mc_addr;
uint64_t mc_misc;
uint32_t flags;
};

struct mca_event_allbanks {
MCA_COMMON;

uint16_t vcpud_id;
uint8_t nbanks;
uint32_t flags;
struct {
uint64_t mc_status;
uint64_t mc_addr;
uint64_t mc_misc;
} bank[1];
};

And you can have many more structs to support future features.

In the code you allocate the size of the struct you want to use:

     struct mca_event *mca = malloc(sizeof(struct mca_event_bank));
     mca->size = sizeof(struct mca_event_bank);
     mca->type = MCA_TYPE_BANK;

in this example you can cast from mca_event to mca_event_bank and back whenever you like.
The generic code only needs to know struct mca_event.

Christoph

Signature · 12 lines
AMD Saxony, Dresden, Germany
Operating System Research Center

Legal Information:
AMD Saxony Limited Liability Company & Co. KG
Sitz (Geschäftsanschrift):
   Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland
Registergericht Dresden: HRA 4896
vertretungsberechtigter Komplementär:
   AMD Saxony LLC (Sitz Wilmington, Delaware, USA)
Geschäftsführer der AMD Saxony LLC:
   Dr. Hans-R. Deppe, Thomas McCoy
#23 lore raw
Quoted 65 lines

-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of Christoph Egger
Sent: 21 June 2007 10:29
To: [email protected]
Cc: Gavin Maltby; Jan Beulich
Subject: Re: [Xen-devel] RFC: MCA/MCE concept

Quoted 3 lines · On Thursday 14 June 2007 13:59:12 Gavin Maltby wrote:
Quoted 2 lines · Christoph Egger
Quoted 1 line · On Monday 04 June 2007 18:16:56 Gavin Maltby wrote:

In terms of the form of the error event data, the

simplest but also

Quoted 38 lines
Quoted 14 lines
Quoted 2 lines

the dumbest would be a binary structure passed from hypervisor to dom0:

struct mca_error_data_ver1 {

(quoted diff) +0 -0
 	uint8_t version;	/* structure version */
 	uint64_t mc_status;
 	uint64_t mc_addr;
 	uint64_t mc_misc;
 	uint16_t mc_chip;
 	uint16_t mc_core;
 	uint16_t mc_bank;
        uint16_t domid;
        uint16_t vcpu_id;
...
Quoted 1 line

};

Since there are multiple MCA detector banks, and more than one may have logged a valid error, we need to think about communicating all the bank error telemetry. This should also allow for there being varying numbers of MCA banks in different proccessor types. So something like

struct {
	uint8_t version;
	uint8_t nbanks;
	uint16_t flags;
	uint16_t domid;
	uint16_t vcpud_id; /* if meaningful? */
	uint8_t chipid;
	uint8_t coreid;
	uint64_t mcg_status;
	struct {
		mc_status;
		mc_addr;
		mc_misc;
	} bank[1];
};
Quoted 5 lines

The bank array is actually sized as per nbanks.

I've added mcg_status and flags. The latter I'd like to use for indicators such as "this error data was artificially injected" etc.

Here is my proposal for a real exensible event structure:

#define MCA_TYPE_COMMON 0
#define MCA_TYPE_BANK 1
#define MCA_TYPE_ALLBANKS 2
...

Quoted 7 lines

#define MCA_COMMON \
size_t size; /* size of this struct in bytes */ uint32_t type; /* structure type */ uint16_t domid;
uint8_t chipid;
uint8_t coreid;
uint64_t mcg_status; /* global status */

At this point, I'd love it if gcc supported unnamed structs! [Which it does only with -fms-extensions].

That would make this sort of thing so much neater.

Quoted 73 lines

The base structure:

struct mca_event {
     MCA_COMMON;
};

The specific structs:

struct mca_event_bank {
   MCA_COMMON;

   uint16_t vcpu_id;
   uint16_t mc_bank;
   uint64_t mc_status;
   uint64_t mc_addr;
   uint64_t mc_misc;
   uint32_t flags;
};
struct mca_event_allbanks {
   MCA_COMMON;

   uint16_t vcpud_id;
   uint8_t nbanks;
   uint32_t flags;
   struct {
(quoted diff) +0 -0
 	uint64_t mc_status;
 	uint64_t mc_addr;
 	uint64_t mc_misc;
   } bank[1];

};

And you can have many more structs to support future features.

In the code you allocate the size of the struct you want to use:

     struct mca_event *mca = malloc(sizeof(struct mca_event_bank));
     mca->size = sizeof(struct mca_event_bank);
     mca->type = MCA_TYPE_BANK;

in this example you can cast from mca_event to mca_event_bank and back whenever you like.
The generic code only needs to know struct mca_event.

Christoph

Signature · 19 lines
AMD Saxony, Dresden, Germany
Operating System Research Center

Legal Information:
AMD Saxony Limited Liability Company & Co. KG
Sitz (Geschäftsanschrift):
   Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland
Registergericht Dresden: HRA 4896
vertretungsberechtigter Komplementär:
   AMD Saxony LLC (Sitz Wilmington, Delaware, USA)
Geschäftsführer der AMD Saxony LLC:
   Dr. Hans-R. Deppe, Thomas McCoy



_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xensource.com/xen-devel