RFC: MCA/MCE concept
Hello!
The current MCA/MCE support in Xen is that it dumps the error and panics.
In the following concept I propose here, there are two places where Xen has to react on.
I) Xen receives a MCE from the CPU and
II) Xen receives Dom0 instructions via Hypercall
The term "self-healing" below is used in the sense of using the most propriate technique(s) to handle an error such as MPR
(http://www.opensparc.net/pubs/papers/MPR_DSN06.pdf),
online-spare RAM or killing/restarting of impacted processes
to prevent crashes of whole guests or the whole machine.
case I) - Xen reveives a MCE from the CPU
1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose
2b) error == UE and UE impacts Xen or Dom0:
Xen does some self-healing
and notifies Dom0 on success if Dom0 installed MCA event handler or Xen panics on failure
2c) error == UE and UE impacts DomU:
In case of Dom0 installed MCA event handler:
Xen notifies Dom0 and Dom0 tells Xen whether
to also notify DomU and/or does some operations on the DomU (case II)
In case Dom0 did not install MCA event handler,
Xen notifies DomU
3a) DomU is a PV guest:
if DomU installed MCA event handler, it gets notified to perform
self-healing
if DomU did not install MCA event handler, notify Dom0 to do
some operations on DomU (case II)
if neither DomU nor Dom0 did not install MCA event handlers,
then Xen kills DomU
3b) DomU is a HVM guest:
if DomU features a PV driver then behave as in 3a)
if DomU enabled MCA/MCE via MSR, inject MCE into guest if DomU did not enable MCA/MCE via MSR, notify Dom0
to do some operations on DomU (case II)
if neither DomU enabled MCA/MCE nor Dom0 did not install
MCA event handler, Xen kills DomU
case II) - Xen reveives Dom0 instructions via Hypercall
There are different reasons, why Xen should do something.
- Dom0 got enough CEs so that UEs are very likely to happen in order to "circumvent" UEs.
- Possible operations on a DomU
- save/restore DomU
- (live-)migrate DomU to a different physical machine
- etc.
Some details
MCE
When an MCE occures, then all the stuff above should NOT happen within the handler, because when an MCE happens within the MCE handler, then the CPU enters shutdown state. So the mail topic "NMI deferal on i386" may be related here.
Notifying guests
Above I am talking about MCA event handler. What I actually mean is a way to inform the guest something happened.
I choosed the term "MCA event handler", because I think, using the event mechanism fits best for this purpose.
Regarding HVM guests with no "MCA PV driver", can enable/disable certain types of errors. They can even control if tehy want to get an exception or do polling.
I would prefer to always inject exceptions into the HVM guest. A HVM guest can't prevent when it always see's exceptions, but I know if they behave correctly, when they assume to get all or certain errors via polling.
Guests which already feature fault management to a certain level when running non-virtualized can easily re-use this capability to decode the error telemetry and handle the error in the virtualized case. Thus forwarding/injecting the error into a guest will only require the translation of the physical/virtual address reported by the HW into guest physical/guest virtual addresses. The error code itself needs no translation/abstraction.
self-healing
IMO, only Xen should use the HW features such as online-spare RAM, which has been introduced in AMD K8 RevF. The HW features should never be visible to any DomUs in order to reduce complexity in Xen. Software-only techniques such as MPR are ok in all guests. Only the Dom0 can tell Xen to do something using HW features.
Christoph
Signature · 12 lines
AMD Saxony, Dresden Germany Operating System Research Center Legal Information: AMD Saxony Limited Liability Company & Co. KG Sitz (Geschäftsanschrift): Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland Registergericht Dresden: HRA 4896 vertretungsberechtigter Komplementär: AMD Saxony LLC (Sitz Wilmington, Delaware, USA) Geschäftsführer der AMD Saxony LLC: Dr. Hans-R. Deppe, Thomas McCoy
Quoted 8 lines
case I) - Xen reveives a MCE from the CPU
1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose
2b) error == UE and UE impacts Xen or Dom0:
A very important aspect here is how you want to classify what impact an uncorrectable has - generally, I can see very few situations where you could confine the impact to a sub-portion of the system (i.e. a single domU, dom0, or Xen). The general rule in my opinion must be to halt the system, the question just is how likely it is that you can get a meaningful message out (to screen, serial, or logs) that can help analyze the problem afterwards. If it is somewhat likely, then dom0 should be involved, otherwise Xen should just shut down the system.
Quoted 11 lines
Xen does some self-healing
and notifies Dom0 on success if Dom0 installed MCA event handler or Xen panics on failure
2c) error == UE and UE impacts DomU:
In case of Dom0 installed MCA event handler:
Xen notifies Dom0 and Dom0 tells Xen whether
to also notify DomU and/or does some operations on the DomU (case II)
In case Dom0 did not install MCA event handler,
Xen notifies DomU
3a) DomU is a PV guest:
Quoted 8 lines
if DomU installed MCA event handler, it gets notified to perform
self-healing
if DomU did not install MCA event handler, notify Dom0 to do
some operations on DomU (case II)
if neither DomU nor Dom0 did not install MCA event handlers,
then Xen kills DomU
3b) DomU is a HVM guest:
if DomU features a PV driver then behave as in 3a)
What significance do pv drivers have here? Or do you mean a pv MCA driver?
Quoted 5 lines
if DomU enabled MCA/MCE via MSR, inject MCE into guest if DomU did not enable MCA/MCE via MSR, notify Dom0
to do some operations on DomU (case II)
if neither DomU enabled MCA/MCE nor Dom0 did not install
MCA event handler, Xen kills DomU
Injecting an MCE to a hvm guest seems at least questionable. It can't really do anything about it (it doesn't even know the real topology of the system it's running on, so addresses stored in MSRs are meaningless - either you allow the to be read untranslated [in which case the guest cannot make sense of them] or you do translation for the guest [in which case it might make assumptions about co-locality of other nearby pages which will be wrong]).
Doing this to a pv domU for purely notification purposes (where the guest knows it's running virtualized) is clearly a different matter.
Quoted 10 lines
case II) - Xen reveives Dom0 instructions via Hypercall
There are different reasons, why Xen should do something.
- Dom0 got enough CEs so that UEs are very likely to happen in order to "circumvent" UEs.
- Possible operations on a DomU
- save/restore DomU
- (live-)migrate DomU to a different physical machine
- etc.
Very heavy-weight operations, which I think are unlikely to succeed if you already suspect the system's going to suffer a UE soon.
Jan
Quoted 9 lines · On Wednesday 30 May 2007 09:19:12 Jan Beulich wrote:
Quoted 8 lines
case I) - Xen reveives a MCE from the CPU
1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose
2b) error == UE and UE impacts Xen or Dom0:
Quoted 8 lines
A very important aspect here is how you want to classify what impact an uncorrectable has - generally, I can see very few situations where you could confine the impact to a sub-portion of the system (i.e. a single domU, dom0, or Xen). The general rule in my opinion must be to halt the system, the question just is how likely it is that you can get a meaningful message out (to screen, serial, or logs) that can help analyze the problem afterwards. If it is somewhat likely, then dom0 should be involved, otherwise Xen should just shut down the system.
Here you can best help out using HW features to handle errors. AMD CPUs features online-spare RAM and Chipkill since K8 RevF.
CPUs such as the Sparc features Data Poisoning. That would be the most handy technique that can be used here.
Maybe this line:
Quoted 1 line
Quoted 1 line
Xen does some self-healing
should be this:
Xen *tries* to do some self-healing
Quoted 2 lines
Quoted 2 lines
and notifies Dom0 on success if Dom0 installed MCA event handler or Xen panics on failure
The first implemenation can just panic here. The self-healing will be implemented and improved over time.
Quoted 17 lines
Quoted 8 lines
2c) error == UE and UE impacts DomU:
In case of Dom0 installed MCA event handler:
Xen notifies Dom0 and Dom0 tells Xen whether
to also notify DomU and/or does some operations on the DomU (case II)
In case Dom0 did not install MCA event handler,
Xen notifies DomU
3a) DomU is a PV guest:Quoted 8 lines
if DomU installed MCA event handler, it gets notified to perform
self-healing
if DomU did not install MCA event handler, notify Dom0 to do
some operations on DomU (case II)
if neither DomU nor Dom0 did not install MCA event handlers,
then Xen kills DomU
3b) DomU is a HVM guest:
if DomU features a PV driver then behave as in 3a)
Quoted 2 lines
What significance do pv drivers have here? Or do you mean a pv MCA driver?
Yes, I mean the pv MCA driver.
Quoted 7 lines
Quoted 6 lines
if DomU enabled MCA/MCE via MSR, inject MCE into guest if DomU did not enable MCA/MCE via MSR, notify Dom0
to do some operations on DomU (case II)
if neither DomU enabled MCA/MCE nor Dom0 did not install
MCA event handler, Xen kills DomU
Quoted 7 lines
Injecting an MCE to a hvm guest seems at least questionable. It can't really do anything about it (it doesn't even know the real topology of the system it's running on, so addresses stored in MSRs are meaningless - either you allow them to be read untranslated [in which case the guest cannot make sense of them] or you do translation for the guest [in which case it might make assumptions about co-locality of other nearby pages which will be wrong]).
Yes, Xen should do the translation for the guest. The assumptions must be fixed then. I know that's easier said than done.
Quoted 2 lines
Doing this to a pv domU for purely notification purposes (where the guest knows it's running virtualized) is clearly a different matter.
Yes, I agree with you here. The general idea behind informing a DomU is to let its own fault management handle the error. It is always better to let it kill a screen saver process and keep the word processor running than killing the whole guest. The DomU should crash itself if it thinks that's the best.
Quoted 11 lines
Quoted 10 lines
case II) - Xen reveives Dom0 instructions via Hypercall
There are different reasons, why Xen should do something.
- Dom0 got enough CEs so that UEs are very likely to happen in order to "circumvent" UEs.
- Possible operations on a DomU
- save/restore DomU
- (live-)migrate DomU to a different physical machine
- etc.
Quoted 2 lines
Very heavy-weight operations, which I think are unlikely to succeed if you already suspect the system's going to suffer a UE soon.
Yes, they are heavy-weight operations. Do you have some ideas, what a Dom0 can do?
The idea here is that the Dom0's fault management helps guests to survive as best as possible.
Christoph
Signature · 12 lines
AMD Saxony, Dresden Germany Operating System Research Center Legal Information: AMD Saxony Limited Liability Company & Co. KG Sitz (Geschäftsanschrift): Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland Registergericht Dresden: HRA 4896 vertretungsberechtigter Komplementär: AMD Saxony LLC (Sitz Wilmington, Delaware, USA) Geschäftsführer der AMD Saxony LLC: Dr. Hans-R. Deppe, Thomas McCoy
Quoted 20 lines
Quoted 1 line
Quoted 1 line
"Christoph Egger" <[email protected]> 30.05.07 09:45 >>>
Quoted 9 lines · On Wednesday 30 May 2007 09:19:12 Jan Beulich wrote:
Quoted 8 lines
case I) - Xen reveives a MCE from the CPU
1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose
2b) error == UE and UE impacts Xen or Dom0:Quoted 8 lines
A very important aspect here is how you want to classify what impact an uncorrectable has - generally, I can see very few situations where you could confine the impact to a sub-portion of the system (i.e. a single domU, dom0, or Xen). The general rule in my opinion must be to halt the system, the question just is how likely it is that you can get a meaningful message out (to screen, serial, or logs) that can help analyze the problem afterwards. If it is somewhat likely, then dom0 should be involved, otherwise Xen should just shut down the system.
Quoted 5 lines
Here you can best help out using HW features to handle errors. AMD CPUs features online-spare RAM and Chipkill since K8 RevF.
CPUs such as the Sparc features Data Poisoning. That would be the most handy technique that can be used here.
But that assumes the error is recoverable (i.e. no other data got corrupted). You still didn't clarify how you intend to determine the impact an uncorrectable error had.
Quoted 30 lines
Quoted 10 lines
Quoted 9 lines
3a) DomU is a PV guest:
if DomU installed MCA event handler, it gets notified to perform
self-healing
if DomU did not install MCA event handler, notify Dom0 to do
some operations on DomU (case II)
if neither DomU nor Dom0 did not install MCA event handlers,
then Xen kills DomU
3b) DomU is a HVM guest:
if DomU features a PV driver then behave as in 3a)Quoted 2 lines
What significance do pv drivers have here? Or do you mean a pv MCA driver?
Yes, I mean the pv MCA driver.
Quoted 7 lines
Quoted 6 lines
if DomU enabled MCA/MCE via MSR, inject MCE into guest if DomU did not enable MCA/MCE via MSR, notify Dom0
to do some operations on DomU (case II)
if neither DomU enabled MCA/MCE nor Dom0 did not install
MCA event handler, Xen kills DomUQuoted 7 lines
Injecting an MCE to a hvm guest seems at least questionable. It can't really do anything about it (it doesn't even know the real topology of the system it's running on, so addresses stored in MSRs are meaningless - either you allow them to be read untranslated [in which case the guest cannot make sense of them] or you do translation for the guest [in which case it might make assumptions about co-locality of other nearby pages which will be wrong]).
Quoted 2 lines
Yes, Xen should do the translation for the guest. The assumptions must be fixed then. I know that's easier said than done.
Exactly - you are proposing to fix all possible OSes, including sufficiently old ones. That's impossible. And I can't even see why an OS intended to run on native hardware would care to try to deal with virtualization aspects like this.
Jan
Quoted 24 lines · On Wednesday 30 May 2007 10:49:40 Jan Beulich wrote:
Quoted 24 lines
Quoted 1 line
Quoted 1 line
"Christoph Egger" <[email protected]> 30.05.07 09:45 >>>
Quoted 9 lines · On Wednesday 30 May 2007 09:19:12 Jan Beulich wrote:
Quoted 8 lines
case I) - Xen reveives a MCE from the CPU
1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose
2b) error == UE and UE impacts Xen or Dom0:Quoted 8 lines
A very important aspect here is how you want to classify what impact an uncorrectable has - generally, I can see very few situations where you could confine the impact to a sub-portion of the system (i.e. a single domU, dom0, or Xen). The general rule in my opinion must be to halt the system, the question just is how likely it is that you can get a meaningful message out (to screen, serial, or logs) that can help analyze the problem afterwards. If it is somewhat likely, then dom0 should be involved, otherwise Xen should just shut down the system.
Here you can best help out using HW features to handle errors. AMD CPUs features online-spare RAM and Chipkill since K8 RevF.
Quoted 6 lines
Quoted 2 lines
CPUs such as the Sparc features Data Poisoning. That would be the most handy technique that can be used here.
But that assumes the error is recoverable (i.e. no other data got corrupted). You still didn't clarify how you intend to determine the impact an uncorrectable error had.
I know. I am lacking a sudden inspiration here.
That's why I discuss this here before writing code that goes to nowhere. Anyone here with a flash of genius? :-)
Quoted 29 lines
Quoted 29 lines
Quoted 10 lines
Quoted 9 lines
3a) DomU is a PV guest:
if DomU installed MCA event handler, it gets notified to perform
self-healing
if DomU did not install MCA event handler, notify Dom0 to do
some operations on DomU (case II)
if neither DomU nor Dom0 did not install MCA event handlers,
then Xen kills DomU
3b) DomU is a HVM guest:
if DomU features a PV driver then behave as in 3a)Quoted 2 lines
What significance do pv drivers have here? Or do you mean a pv MCA driver?
Yes, I mean the pv MCA driver.
Quoted 13 lines
Quoted 5 lines
if DomU enabled MCA/MCE via MSR, inject MCE into guest if DomU did not enable MCA/MCE via MSR, notify Dom0
to do some operations on DomU (case II)
if neither DomU enabled MCA/MCE nor Dom0 did not install
MCA event handler, Xen kills DomUInjecting an MCE to a hvm guest seems at least questionable. It can't really do anything about it (it doesn't even know the real topology of the system it's running on, so addresses stored in MSRs are meaningless
- either you allow them to be read untranslated [in which case the guest cannot make sense of them] or you do translation for the guest [in which case it might make assumptions about co-locality of other nearby pages which will be wrong]).
Quoted 7 lines
Quoted 2 lines
Yes, Xen should do the translation for the guest. The assumptions must be fixed then. I know that's easier said than done.
Exactly - you are proposing to fix all possible OSes, including sufficiently old ones. That's impossible. And I can't even see why an OS intended to run on native hardware would care to try to deal with virtualization aspects like this.
I think, it was not obvious that
Xen should not inject failures into DomU that don't feature a fault management. In this case, either Dom0 tells Xen what to do with the DomU or Xen just kills the DomU.
<snippet from above>
Quoted 1 line
Quoted 1 line
Quoted 1 line
Quoted 1 line
3a) DomU is a PV guest:
....
Quoted 6 lines
Quoted 6 lines
Quoted 6 lines
Quoted 6 lines
if DomU did not install MCA event handler, notify Dom0 to do
some operations on DomU (case II)
if neither DomU nor Dom0 did not install MCA event handlers,
then Xen kills DomU3b) DomU is a HVM guest:
....
Quoted 4 lines
Quoted 4 lines
Quoted 4 lines
Quoted 4 lines
if DomU did not enable MCA/MCE via MSR, notify Dom0
to do some operations on DomU (case II)
if neither DomU enabled MCA/MCE nor Dom0 did not install
MCA event handler, Xen kills DomU
</snippet>
Christoph
Signature · 12 lines
AMD Saxony, Dresden Germany Operating System Research Center Legal Information: AMD Saxony Limited Liability Company & Co. KG Sitz (Geschäftsanschrift): Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland Registergericht Dresden: HRA 4896 vertretungsberechtigter Komplementär: AMD Saxony LLC (Sitz Wilmington, Delaware, USA) Geschäftsführer der AMD Saxony LLC: Dr. Hans-R. Deppe, Thomas McCoy
Quoted 16 lines
Quoted 8 lines
Quoted 8 lines
Quoted 7 lines
Injecting an MCE to a hvm guest seems at least questionable. It can't really do anything about it (it doesn't even know the real topology of the system it's running on, so addresses stored in MSRs are meaningless
- either you allow them to be read untranslated [in which case the guest cannot make sense of them] or you do translation for the guest [in which case it might make assumptions about co-locality of other nearby pages which will be wrong]).Quoted 7 lines
Quoted 2 lines
Yes, Xen should do the translation for the guest. The assumptions must be fixed then. I know that's easier said than done.
Exactly - you are proposing to fix all possible OSes, including sufficiently old ones. That's impossible. And I can't even see why an OS intended to run on native hardware would care to try to deal with virtualization aspects like this.
Quoted 4 lines
I think, it was not obvious that
Xen should not inject failures into DomU that don't feature a fault management. In this case, either Dom0 tells Xen what to do with the DomU or Xen just kills the DomU.
You apparently didn't get my point - even if the guest set up MCE properly (by setting CR4.MCE and possibly writing some MSRs) you cannot conclude that it is aware of the fact that it is running in a virtualized environment and that guest physical address relations do not map to machine physical address relations (i.e. a set of pages contiguous in gpa space is almost guaranteed to be discontiguous in mpa space). Hence if it is more than a single byte/cache line/page that is affected, any such assumptions made in the guest will be wrong.
Jan
Quoted 21 lines · On Wednesday 30 May 2007 11:59:31 Jan Beulich wrote:
Quoted 16 lines
Quoted 8 lines
Quoted 8 lines
Quoted 7 lines
Injecting an MCE to a hvm guest seems at least questionable. It can't really do anything about it (it doesn't even know the real topology of the system it's running on, so addresses stored in MSRs are meaningless - either you allow them to be read untranslated [in which case the guest cannot make sense of them] or you do translation for the guest [in which case it might make assumptions about co-locality of other nearby pages which will be wrong]).
Quoted 7 lines
Quoted 2 lines
Yes, Xen should do the translation for the guest. The assumptions must be fixed then. I know that's easier said than done.
Exactly - you are proposing to fix all possible OSes, including sufficiently old ones. That's impossible. And I can't even see why an OS intended to run on native hardware would care to try to deal with virtualization aspects like this.
Quoted 4 lines
I think, it was not obvious that
Xen should not inject failures into DomU that don't feature a fault management. In this case, either Dom0 tells Xen what to do with the DomU or Xen just kills the DomU.
Quoted 8 lines
You apparently didn't get my point - even if the guest set up MCE properly (by setting CR4.MCE and possibly writing some MSRs) you cannot conclude that it is aware of the fact that it is running in a virtualized environment and that guest physical address relations do not map to machine physical address relations (i.e. a set of pages contiguous in gpa space is almost guaranteed to be discontiguous in mpa space). Hence if it is more than a single byte/cache line/page that is affected, any such assumptions made in the guest will be wrong.
Ah, I see. So HVM guests can only handle those errors where this assumption is guaranteed to be correct. Xen needs to check the error type, the address and the size (= address range) for this.
If Xen can't determine for sure, the guest can handle this right, then Xen has to handle the DomU as a guest which does not feature fault management.
Christoph
Signature · 12 lines
AMD Saxony, Dresden, Germany Operating System Research Center Legal Information: AMD Saxony Limited Liability Company & Co. KG Sitz (Geschäftsanschrift): Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland Registergericht Dresden: HRA 4896 vertretungsberechtigter Komplementär: AMD Saxony LLC (Sitz Wilmington, Delaware, USA) Geschäftsführer der AMD Saxony LLC: Dr. Hans-R. Deppe, Thomas McCoy
Hi,
On 05/30/07 10:10, Christoph Egger wrote:
[cut]
Quoted 14 lines
Quoted 14 lines
Quoted 14 lines
Quoted 9 lines
Quoted 1 line
2b) error == UE and UE impacts Xen or Dom0:
A very important aspect here is how you want to classify what impact an uncorrectable has - generally, I can see very few situations where you could confine the impact to a sub-portion of the system (i.e. a single domU, dom0, or Xen). The general rule in my opinion must be to halt the system, the question just is how likely it is that you can get a meaningful message out (to screen, serial, or logs) that can help analyze the problem afterwards. If it is somewhat likely, then dom0 should be involved, otherwise Xen should just shut down the system.
Here you can best help out using HW features to handle errors. AMD CPUs features online-spare RAM and Chipkill since K8 RevF.
CPUs such as the Sparc features Data Poisoning. That would be the most handy technique that can be used here.
Quoted 7 lines
Quoted 3 lines
But that assumes the error is recoverable (i.e. no other data got corrupted). You still didn't clarify how you intend to determine the impact an uncorrectable error had.
I know. I am lacking a sudden inspiration here.
That's why I discuss this here before writing code that goes to nowhere. Anyone here with a flash of genius? :-)
For a first phase I'd suggest that treating an uncorrectable error as terminal to the entire system (e.g., panic hypervisor or setup a hardware reset mechanism such as Sync Flood) is practical and safe, and allows us to concentrate on getting some more basic elements in place. As Christoph says we really need some form of data poisoning supported on the platform to really be able to isolate the impact of an uncorrectable error. In the absence of such support I think some fancy heuristics could work in some limited cases (e.g., a memory uncorrectable on a page that only a domU has a mapping to and which is not shared with any other domain not even via a front/backend driver) but the penalty for bugs in those heuristics is silent data corruption which is the ultimate crime.
Quoted 10 lines
Quoted 10 lines
Quoted 10 lines
Quoted 10 lines
Quoted 10 lines
3a) DomU is a PV guest:
if DomU installed MCA event handler, it gets notified to perform
self-healing
if DomU did not install MCA event handler, notify Dom0 to do
some operations on DomU (case II)
if neither DomU nor Dom0 did not install MCA event handlers,
then Xen kills DomU
3b) DomU is a HVM guest:
if DomU features a PV driver then behave as in 3a)
Quoted 2 lines
Quoted 2 lines
Quoted 2 lines
Quoted 2 lines
What significance do pv drivers have here? Or do you mean a pv MCA driver?
[cut]
My feeling is that the hypervisor and dom0 own the hardware and as such all hardware fault management should reside there. So we should never deliver any form of #MC to a domU, nor should a poll of MCA state from a domU ever observe valid state (e.g, make the RDMSR return 0). So all handling, logging and diagnosis as well as hardware response actions (such as to deploy an online spare chip-select) are controlled in the hypervisor/dom0 combination. That seems a consistent model - e.g., if a domU is migrated to another system it should not carry the diagnosis state of the original system across etc, since that belongs with the one domain that cannot migrate.
But that is not to say that (I think at a future phase) domU should not participate in a higher-level fault management function, at the direction of the hypervisor/dom0 combo. For example if/when we can isolate an uncorrectable error to a single domU we could forward such an event to the affected domU if it has registered its ability/interest in such events. These won't be in the form of a faked #MC or anything, instead they'd be some form of synchronous trap experienced when next the affected domU context resumes on CPU. The intelligent domU handler can then decide whether the domU must panic, whether it could simply kill the affected process etc. Those details are clearly sketchy, but the idea is to up-level the communication to a domU to be more like "you're broken" rather than "here's a machine-level hardware error for you to interpret and decide what to do with".
Gavin
[snip]
Quoted 6 lines
My feeling is that the hypervisor and dom0 own the hardware and as such
all hardware fault management should reside there. So we should never deliver any form of #MC to a domU, nor should a poll of MCA state from a domU ever observe valid state (e.g, make the RDMSR return 0). So all handling, logging and diagnosis as well as hardware
Quoted 8 lines
response actions
(such as to deploy an online spare chip-select) are controlled in the hypervisor/dom0 combination. That seems a consistent model - e.g.,
if a domU is migrated to another system it should not carry the diagnosis state of the original system across etc, since that belongs with
the one domain that cannot migrate.
I agree entirely with this.
Quoted 10 lines
But that is not to say that (I think at a future phase) domU should not
participate in a higher-level fault management function, at the direction
of the hypervisor/dom0 combo. For example if/when we can isolate an uncorrectable error to a single domU we could forward such an event to the affected domU if it has registered its ability/interest in such events. These won't be in the form of a faked #MC or anything, instead they'd be some form of synchronous trap experienced when next
Quoted 8 lines
the affected domU context resumes on CPU. The intelligent domU handler
can then decide whether the domU must panic, whether it could simply kill the affected process etc. Those details are clearly sketchy, but the
idea is to up-level the communication to a domU to be more like "you're broken" rather than "here's a machine-level hardware error for you to interpret and decide what to do with".
Yes, this makes much more sense than forwarding #MC, as the guest would have a hard time to actually do anything really useful with this. As far as I know, most uncorrectable errors are near enough entirely fatal in most commercial non-Enterprise OS's anyways - e.g. in Windows XP or Server 2K3, it always ends in a blue-screen - which is hardly any better than the guest being "humanely euthenazed" by Dom0.
I take it this would be some sort of hypercall (available through the regular PV-driver interface for HVM guests) to say "Let me know if I'm broken - trap on vector X".
--
Mats
Quoted 10 lines
Gavin
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xensource.com/xen-devel
Quoted 44 lines · Mats
[snip]
Quoted 6 lines
My feeling is that the hypervisor and dom0 own the hardware and as such
all hardware fault management should reside there. So we should never deliver any form of #MC to a domU, nor should a poll of MCA state from a domU ever observe valid state (e.g, make the RDMSR return 0). So all handling, logging and diagnosis as well as hardwareQuoted 8 lines
response actions
(such as to deploy an online spare chip-select) are controlled in the hypervisor/dom0 combination. That seems a consistent model - e.g.,
if a domU is migrated to another system it should not carry the diagnosis state of the original system across etc, since that belongs with
the one domain that cannot migrate.I agree entirely with this.
Quoted 9 lines
But that is not to say that (I think at a future phase) domU should not
participate in a higher-level fault management function, at the direction
of the hypervisor/dom0 combo. For example if/when we can isolate an uncorrectable error to a single domU we could forward such an event to the affected domU if it has registered its ability/interest in such events. These won't be in the form of a faked #MC or anything, instead they'd be some form of synchronous trap experienced when nextQuoted 8 lines
the affected domU context resumes on CPU. The intelligent domU handler
can then decide whether the domU must panic, whether it could simply kill the affected process etc. Those details are clearly sketchy, but the
idea is to up-level the communication to a domU to be more like "you're broken" rather than "here's a machine-level hardware error for you to interpret and decide what to do with".Yes, this makes much more sense than forwarding #MC, as the guest would have a hard time to actually do anything really useful with this. As far as I know, most uncorrectable errors are near enough entirely fatal in most commercial non-Enterprise OS's anyways - e.g. in Windows XP or Server 2K3, it always ends in a blue-screen - which is hardly any better than the guest being "humanely euthenazed" by Dom0.
Quoted 3 lines
I take it this would be some sort of hypercall (available through the regular PV-driver interface for HVM guests) to say "Let me know if I'm broken - trap on vector X".
For short, guests with a PV MCA driver will see a certain event (assuming the event mechanism will be used for the notification) and guests w/o a PV MCA driver will see a "General Protection Fault". Is that right?
Quoted 5 lines
--
MatsQuoted 2 lines
Gavin
Signature · 12 lines
AMD Saxony, Dresden, Germany Operating System Research Center Legal Information: AMD Saxony Limited Liability Company & Co. KG Sitz (Geschäftsanschrift): Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland Registergericht Dresden: HRA 4896 vertretungsberechtigter Komplementär: AMD Saxony LLC (Sitz Wilmington, Delaware, USA) Geschäftsführer der AMD Saxony LLC: Dr. Hans-R. Deppe, Thomas McCoy
Quoted 70 lines
-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of Christoph Egger
Sent: 01 June 2007 09:12
To: [email protected]
Cc: Gavin Maltby
Subject: Re: [Xen-devel] RFC: MCA/MCE conceptQuoted 5 lines · Mats
[snip]
Quoted 3 lines
My feeling is that the hypervisor and dom0 own the hardware and as such
all hardware fault management should reside there. So weshould never
Quoted 1 line
Quoted 1 line
deliver any form of #MC to a domU, nor should a poll of
MCA state from
Quoted 11 lines
Quoted 10 lines
a domU ever observe valid state (e.g, make the RDMSR return 0). So all handling, logging and diagnosis as well as hardware response actions
(such as to deploy an online spare chip-select) are controlled in the hypervisor/dom0 combination. That seems a consistent model - e.g.,
if a domU is migrated to another system it should not carry the diagnosis state of the original system across etc, since that belongs with
the one domain that cannot migrate.Quoted 7 lines
I agree entirely with this.
Quoted 5 lines
But that is not to say that (I think at a future phase) domU should not
participate in a higher-level fault management function, at the direction
of the hypervisor/dom0 combo. For example if/when we canisolate an
Quoted 1 line
Quoted 1 line
uncorrectable error to a single domU we could forward
such an event to
Quoted 1 line
Quoted 1 line
the affected domU if it has registered its
ability/interest in such
Quoted 2 lines
Quoted 2 lines
events. These won't be in the form of a faked #MC or anything, instead they'd be some form of synchronous trap
experienced when next
Quoted 3 lines
Quoted 3 lines
the affected domU context resumes on CPU. The intelligent domU handler
can then decide whether the domU must panic, whether itcould simply
Quoted 4 lines
Quoted 4 lines
kill the affected process etc. Those details are clearly sketchy, but the
idea is to up-level the communication to a domU to be more like "you're broken" rather than "here's a machine-levelhardware error for
Quoted 3 lines
Quoted 1 line
you to interpret and decide what to do with".
Yes, this makes much more sense than forwarding #MC, as the
guest would
Quoted 1 line
have a hard time to actually do anything really useful with
this. As far
Quoted 1 line
as I know, most uncorrectable errors are near enough
entirely fatal in
Quoted 2 lines
most commercial non-Enterprise OS's anyways - e.g. in Windows XP or Server 2K3, it always ends in a blue-screen - which is
hardly any better
Quoted 3 lines
than the guest being "humanely euthenazed" by Dom0.
I take it this would be some sort of hypercall (available
through the
Quoted 8 lines
Quoted 1 line
regular PV-driver interface for HVM guests) to say "Let me
know if I'm
Quoted 1 line
broken - trap on vector X".
For short, guests with a PV MCA driver will see a certain event (assuming the event mechanism will be used for the notification) and guests w/o a PV MCA driver will see a "General Protection Fault". Is that right?
Not sure if GP fault is the right thing for non-"MCA PV driver" domains. I think "just killing" the domain is the right thing to do.
We can't gurantee that a GP fault is actually going to "kill" the guest. Let's assume the code that ran on the guest was something along the lines of:
int some_function(...)
{
...
try {
...
/* Some code that does quite a lot of "random" processing that may cause, for example, GP fault */
...
} catch(Exception e)
{
...
/* handles GP fault within the kernel code */
... }
}
Note that Windows kernel drivers are allowed to use the kernel exception handling, and ARE allowed to "allow" GP faults if they wish to do so. [Don't ask me why MS allows this, but that's the case, so we have to live with it].
I'm not sure if Linux, Solaris, *BSD, OS/2 or other OS's will allow "catching" a Kernel GP fault in a non-precise fashion (I know Linux has exception handling for EXACT positions in the code). But since at least one kernel DOES allow this, we can't be sure that a GPF will destroy the guest.
Second point to note is of course that if the guest is in user-mode when the GPF happens, then almost all OS's will just kill the application - and there's absolutely no reason to believe that the application running is necessarily where the actual memory problem is - it may be caused by memory scrubbing for example.
Whatever we do to the guest, it should be a "certain death", unless the kernel has told us "I can handle MCE's".
--
Mats
Quoted 30 lines
Quoted 6 lines
--
MatsQuoted 2 lines
Gavin
Signature · 19 lines
AMD Saxony, Dresden, Germany Operating System Research Center Legal Information: AMD Saxony Limited Liability Company & Co. KG Sitz (Geschäftsanschrift): Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland Registergericht Dresden: HRA 4896 vertretungsberechtigter Komplementär: AMD Saxony LLC (Sitz Wilmington, Delaware, USA) Geschäftsführer der AMD Saxony LLC: Dr. Hans-R. Deppe, Thomas McCoy _______________________________________________ Xen-devel mailing list [email protected] http://lists.xensource.com/xen-devel
On Friday 01 June 2007 10:55:28 Petersson, Mats wrote:
[snip]
Quoted 26 lines
Quoted 4 lines
For short, guests with a PV MCA driver will see a certain event (assuming the event mechanism will be used for the notification) and guests w/o a PV MCA driver will see a "General Protection Fault". Is that right?
Not sure if GP fault is the right thing for non-"MCA PV driver" domains. I think "just killing" the domain is the right thing to do.
We can't gurantee that a GP fault is actually going to "kill" the guest. Let's assume the code that ran on the guest was something along the lines of:
int
some_function(...){ ... try { ... /* Some code that does quite a lot of "random" processing that may cause, for example, GP fault */ ... } catch(Exception e) { ... /* handles GP fault within the kernel code */ ...
Quoted 8 lines
}
}Note that Windows kernel drivers are allowed to use the kernel exception handling, and ARE allowed to "allow" GP faults if they wish to do so. [Don't ask me why MS allows this, but that's the case, so we have to live with it].
In that case, it will die sooner or later *after* consuming the data in error. That means, the guest continues to live for an unknown time...
Quoted 4 lines
I'm not sure if Linux, Solaris, *BSD, OS/2 or other OS's will allow "catching" a Kernel GP fault in a non-precise fashion (I know Linux has exception handling for EXACT positions in the code). But since at least one kernel DOES allow this, we can't be sure that a GPF will destroy the guest.
When Linux and *BSD see a GPF while they are in userspace, then they kill the process with a SIGSEGV. If they are in kernelspace, then they panic.
Quoted 8 lines
Second point to note is of course that if the guest is in user-mode when the GPF happens, then almost all OS's will just kill the application - and there's absolutely no reason to believe that the application running is necessarily where the actual memory problem is - it may be caused by memory scrubbing for example.
Whatever we do to the guest, it should be a "certain death", unless the kernel has told us "I can handle MCE's".
It is obvious that there is no absolute generic way to handle all sort of buggy guests. I vote for:
If DomU has a PV MCA driver use this or inject a GPF. Multiplexing all the MSR's related to emulate MCA/MCE for the guests is much more complex than just injecting a GPF - and slower.
Keir, what are your opinions on this thread?
Christoph
Signature · 12 lines
AMD Saxony, Dresden, Germany Operating System Research Center Legal Information: AMD Saxony Limited Liability Company & Co. KG Sitz (Geschäftsanschrift): Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland Registergericht Dresden: HRA 4896 vertretungsberechtigter Komplementär: AMD Saxony LLC (Sitz Wilmington, Delaware, USA) Geschäftsführer der AMD Saxony LLC: Dr. Hans-R. Deppe, Thomas McCoy
Quoted 53 lines
-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of Christoph Egger
Sent: 01 June 2007 10:28
To: [email protected]
Cc: Gavin Maltby; Keir Fraser
Subject: Re: [Xen-devel] RFC: MCA/MCE conceptOn Friday 01 June 2007 10:55:28 Petersson, Mats wrote:
[snip]
Quoted 3 lines
Quoted 3 lines
For short, guests with a PV MCA driver will see a certain event (assuming the event mechanism will be used for the notification) and guests w/o a PV MCA driver will see a "General
Protection Fault".
Quoted 3 lines
Quoted 1 line
Is that right?
Not sure if GP fault is the right thing for non-"MCA PV
driver" domains. I
Quoted 3 lines
think "just killing" the domain is the right thing to do.
We can't gurantee that a GP fault is actually going to
"kill" the guest.
Quoted 1 line
Let's assume the code that ran on the guest was something
along the lines
Quoted 10 lines
of:
int
some_function(...){ ... try { ... /* Some code that does quite a lot of "random"processing that may
Quoted 11 lines
cause, for example, GP fault */ ...
} catch(Exception e){ ... /* handles GP fault within the kernel code */ ...}
}Note that Windows kernel drivers are allowed to use the
kernel exception
Quoted 1 line
handling, and ARE allowed to "allow" GP faults if they wish
Quoted 8 lines
to do so.
Quoted 1 line
[Don't ask me why MS allows this, but that's the case, so
we have to live
Quoted 1 line
with it].
In that case, it will die sooner or later *after* consuming the data in error.
That means, the guest continues to live for an unknown time...
Yes. What I'm worried about is that if you have a "transient" or "few-bit" error in a rarely used, the guest may well live a LONG time with incorrect data and potentially not get it detected for quite some time again (say it's two bits have stuck to 0, and the data is then written back with the zero's there - next time we read it, no error, since the data has zero's in that location.
Also consider the case where one cell (or small block of cells) has gone bad, but it's only used by one single piece of code that is using this try/catch code? I know, this is probably relatively rare, but I'm still worried that it will "break" things...
Quoted 28 lines
Quoted 3 lines
I'm not sure if Linux, Solaris, *BSD, OS/2 or other OS's will allow "catching" a Kernel GP fault in a non-precise fashion (I
know Linux has
Quoted 1 line
exception handling for EXACT positions in the code). But
since at least one
Quoted 1 line
kernel DOES allow this, we can't be sure that a GPF will
destroy the guest.
When Linux and *BSD see a GPF while they are in userspace, then they kill
the process with a SIGSEGV. If they are in kernelspace, then they panic.Quoted 1 line
Second point to note is of course that if the guest is in
user-mode when
Quoted 1 line
the GPF happens, then almost all OS's will just kill the
application - and
Quoted 1 line
there's absolutely no reason to believe that the
application running is
Quoted 1 line
necessarily where the actual memory problem is - it may be
caused by memory
Quoted 3 lines
scrubbing for example.
Whatever we do to the guest, it should be a "certain
death", unless the
Quoted 1 line
kernel has told us "I can handle MCE's".
Quoted 8 lines
It is obvious that there is no absolute generic way to handle all sort of
buggy guests. I vote for:If DomU has a PV MCA driver use this or inject a GPF. Multiplexing all the MSR's related to emulate MCA/MCE for the guests is much
more complex than just injecting a GPF - and slower.
Emulating MCE to the guest wasn't my intended alternative suggestion. Instead, my idea was that if the guest hasn't registered a "PV MCE handler", we just immediately kill the domain as such - e.g similar to "domain_crash_synchronous()". Don't let the guest have any chance to "do something wrong" in the process - it's already broken, and letting it run any further will almost certainly not help matters. This may not be the prettiest solution, but then on the other hand, a "Windows blue-screen" or Linux "oops" saying GP fault happened at some random place in the guest isn't exactly helping the SysAdmin understand the problem either.
--
Mats
Quoted 29 lines
Keir, what are your opinions on this thread?
Christoph
Signature · 19 lines
AMD Saxony, Dresden, Germany Operating System Research Center Legal Information: AMD Saxony Limited Liability Company & Co. KG Sitz (Geschäftsanschrift): Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland Registergericht Dresden: HRA 4896 vertretungsberechtigter Komplementär: AMD Saxony LLC (Sitz Wilmington, Delaware, USA) Geschäftsführer der AMD Saxony LLC: Dr. Hans-R. Deppe, Thomas McCoy _______________________________________________ Xen-devel mailing list [email protected] http://lists.xensource.com/xen-devel
Hi
On 06/01/07 10:48, Petersson, Mats wrote:
[cut]
Quoted 7 lines
Quoted 7 lines
Quoted 1 line
Note that Windows kernel drivers are allowed to use the
kernel exception
Quoted 1 line
handling, and ARE allowed to "allow" GP faults if they wish
to do so.
Quoted 1 line
[Don't ask me why MS allows this, but that's the case, so
we have to live
Quoted 1 line
with it].
Quoted 8 lines
Quoted 2 lines
In that case, it will die sooner or later *after* consuming the data in error. That means, the guest continues to live for an unknown time...
Yes. What I'm worried about is that if you have a "transient" or "few-bit" error in a rarely used, the guest may well live a LONG time with incorrect data and potentially not get it detected for quite some time again (say it's two bits have stuck to 0, and the data is then written back with the zero's there
- next time we read it, no error, since the data has zero's in that location.
I don't believe GP faults and uncorrectable errors really overlap that much. In a GP fault the extent of the damage is known - you tried to read from an address not in your address space, you lacked permissions for an operation etc. In an uncorrected error situation it is difficult to understand the bounds of the problem in that way - unless the hardware assists with data poisoning etc such errors may well be unconstrained and affect a wider area than just the bracket of code that caught a GP fault.
You can often ring-fence critical code sequences by inserting error barrier instructions before and after it. Those operations are usually very expensive (drain the pipeline or similar) and are suitable only in special places.
When running natively it is usually the "owner" of affected data that sees it bad in memory, eg from a read it made. In those cases we have the owner on cpu and can kill/signal it synchronously. There are times when the kernel may be shifting some data on behalf of the application owner (eg, copyin/copyout, shift network data etc) in which case we still have a handle on the real owner. If the access is from a scrub then we should not panic - just wait and see if the owner does indeed use the bad data at which time we take appropriate action.
With the virtualisation layer there is the additional case of the HV or dom0 performing operations on behalf of a guest, ie the HV may make the access that traps but it's own state is not affected.
CPU errors get still trickier. For example what do we do when we're told that while running guest A we displaced modified data from l2cache that had uncorrectable ECC? We have a physical address only, and no idea of who the data belongs to (guest A, a recently scheduled guest, or the HV?). Where cachelines are tagged with some form of context or guest ID you have a chance, provided that is reported in the error state.
Quoted 14 lines
Also consider the case where one cell (or small block of cells) has gone bad, but it's only used by one single piece of code that is using this try/catch code? I know, this is probably relatively rare, but I'm still worried that it will "break" things...
Quoted 10 lines
Quoted 2 lines
I'm not sure if Linux, Solaris, *BSD, OS/2 or other OS's will allow "catching" a Kernel GP fault in a non-precise fashion (I
know Linux has
Quoted 1 line
exception handling for EXACT positions in the code). But
since at least one
Quoted 1 line
kernel DOES allow this, we can't be sure that a GPF will
destroy the guest.
When Linux and *BSD see a GPF while they are in userspace, then they kill the process with a SIGSEGV. If they are in kernelspace, then they panic.
Solaris has some wrappers that can be applied, maybe at some expense to performance, to make protected accesses that will catch and survive various types of error including hardware errors, wild pointers etc.
Quoted 9 lines
Quoted 9 lines
Quoted 1 line
Second point to note is of course that if the guest is in
user-mode when
Quoted 1 line
the GPF happens, then almost all OS's will just kill the
application - and
Quoted 1 line
there's absolutely no reason to believe that the
application running is
Quoted 1 line
necessarily where the actual memory problem is - it may be
caused by memory
Quoted 1 line
scrubbing for example.
Yes, these are the myriad permutations I was alluding to above.
Quoted 2 lines
Quoted 2 lines
Quoted 1 line
Whatever we do to the guest, it should be a "certain
death", unless the
Yes, certain and instant death unless it is a PV guest that has registered the ability to deal with these more elegantly.
Quoted 6 lines
Quoted 6 lines
Quoted 1 line
kernel has told us "I can handle MCE's".
It is obvious that there is no absolute generic way to handle all sort of buggy guests. I vote for:
If DomU has a PV MCA driver use this or inject a GPF. Multiplexing all the MSR's related to emulate MCA/MCE for the guests is much more complex than just injecting a GPF - and slower.
Do we need to send the non-PV guest a signal of any kind to kill it? After all, we can stop it running any further instructions (and perhaps avoid the use of bad data) by deciding within the HV or dom0 simply to abort that guest. There is no loss to diagnosability since the HV/dom0 combination is doing that, anyway.
Quoted 7 lines
Emulating MCE to the guest wasn't my intended alternative suggestion. Instead,
my idea was that if the guest hasn't registered a "PV MCE handler", we just immediately kill the domain as such - e.g similar to "domain_crash_synchronous()". Don't let the guest have any chance to "do something wrong" in the process - it's
already broken, and letting it run any further will almost certainly not help matters.
This may not be the prettiest solution, but then on the other hand, a "Windows blue-screen"
or Linux "oops" saying GP fault happened at some random place in the guest isn't exactly
helping the SysAdmin understand the problem either.
Agreed - don't let the affected guest run one more instruction if we can. Sysadmins will learn to consult dom0 diagnostics to see if they explain any sudden guest deaths - no need, as you say, to splurge any raw error data to them.
Gavin
Quoted 32 lines
--
MatsQuoted 28 lines
Keir, what are your opinions on this thread?
Christoph
Signature · 19 lines
AMD Saxony, Dresden, Germany Operating System Research Center Legal Information: AMD Saxony Limited Liability Company & Co. KG Sitz (Geschäftsanschrift): Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland Registergericht Dresden: HRA 4896 vertretungsberechtigter Komplementär: AMD Saxony LLC (Sitz Wilmington, Delaware, USA) Geschäftsführer der AMD Saxony LLC: Dr. Hans-R. Deppe, Thomas McCoy _______________________________________________ Xen-devel mailing list [email protected] http://lists.xensource.com/xen-devel
Signature · 1 line
Gavin Maltby, Solaris Kernel Development.
Quoted 135 lines
-----Original Message-----
From: [email protected] [mailto:[email protected]]
Sent: 01 June 2007 11:57
To: Petersson, Mats
Cc: Egger, Christoph; [email protected]; Keir Fraser
Subject: Re: [Xen-devel] RFC: MCA/MCE conceptHi
On 06/01/07 10:48, Petersson, Mats wrote:
[cut]Quoted 4 lines
Quoted 4 lines
Quoted 1 line
Note that Windows kernel drivers are allowed to use the
kernel exception
Quoted 1 line
handling, and ARE allowed to "allow" GP faults if they wish
to do so.
Quoted 8 lines
Quoted 6 lines
Quoted 1 line
[Don't ask me why MS allows this, but that's the case, so
we have to live
Quoted 1 line
with it].
In that case, it will die sooner or later *after* consuming the data in error.
That means, the guest continues to live for an unknown time...Yes. What I'm worried about is that if you have a
"transient" or "few-bit"
Quoted 1 line
error in a rarely used, the guest may well live a LONG
time with incorrect
Quoted 1 line
data and potentially not get it detected for quite some
time again (say it's
Quoted 1 line
two bits have stuck to 0, and the data is then written back
with the zero's there
Quoted 1 line
- next time we read it, no error, since the data has
zero's in that location.
I don't believe GP faults and uncorrectable errors really overlap that much.
In a GP fault the extent of the damage is known - you tried to read from
an address not in your address space, you lacked permissions for an operation
etc. In an uncorrected error situation it is difficult to understand the
bounds of the problem in that way - unless the hardware assists with data poisoning etc such errors may well be unconstrained and affect a wider area than just the bracket of code that caught a GP fault.You can often ring-fence critical code sequences by inserting error barrier instructions before and after it. Those operations are usually very expensive (drain the pipeline or similar) and are suitable only in special places.
When running natively it is usually the "owner" of affected data that sees it bad in memory, eg from a read it made. In those cases we have the owner on cpu and can kill/signal it synchronously. There are times when the kernel may be shifting some data on behalf of the application owner (eg, copyin/copyout, shift network data etc) in which case we still have a handle on the real owner. If the access is from a scrub then we should not panic - just wait and see if the owner does indeed use the bad data at which time we take appropriate action.
With the virtualisation layer there is the additional case of the HV or
dom0 performing operations on behalf of a guest, ie the HV may make the
access that traps but it's own state is not affected.CPU errors get still trickier. For example what do we do when we're told that
while running guest A we displaced modified data from l2cache that had uncorrectable ECC? We have a physical address only, and no idea of who the
data belongs to (guest A, a recently scheduled guest, or the HV?). Where
cachelines are tagged with some form of context or guest ID you have a chance, provided that is reported in the error state.Quoted 1 line
Also consider the case where one cell (or small block of
cells) has gone bad,
Quoted 1 line
but it's only used by one single piece of code that is
using this try/catch code?
Quoted 1 line
I know, this is probably relatively rare, but I'm still
worried that it will "break" things...
Quoted 1 line
Quoted 1 line
Quoted 1 line
I'm not sure if Linux, Solaris, *BSD, OS/2 or other OS's
will allow
Quoted 11 lines
Quoted 11 lines
Quoted 1 line
"catching" a Kernel GP fault in a non-precise fashion (I
know Linux has
Quoted 1 line
exception handling for EXACT positions in the code). But
since at least one
Quoted 1 line
kernel DOES allow this, we can't be sure that a GPF will
destroy the guest.
When Linux and *BSD see a GPF while they are in userspace, then they kill
the process with a SIGSEGV. If they are in kernelspace, then they panic.Solaris has some wrappers that can be applied, maybe at some expense to
performance, to make protected accesses that will catch and survive various types of error including hardware errors, wild pointers etc.Quoted 9 lines
Quoted 9 lines
Quoted 1 line
Second point to note is of course that if the guest is in
user-mode when
Quoted 1 line
the GPF happens, then almost all OS's will just kill the
application - and
Quoted 1 line
there's absolutely no reason to believe that the
application running is
Quoted 1 line
necessarily where the actual memory problem is - it may be
caused by memory
Quoted 1 line
scrubbing for example.
Yes, these are the myriad permutations I was alluding to above.
Quoted 2 lines
Quoted 2 lines
Quoted 1 line
Whatever we do to the guest, it should be a "certain
death", unless the
Yes, certain and instant death unless it is a PV guest that has registered
the ability to deal with these more elegantly.Quoted 9 lines
Quoted 9 lines
Quoted 1 line
kernel has told us "I can handle MCE's".
It is obvious that there is no absolute generic way to handle all sort of
buggy guests. I vote for:If DomU has a PV MCA driver use this or inject a GPF. Multiplexing all the MSR's related to emulate MCA/MCE for the guests is much
more complex than just injecting a GPF - and slower.
Quoted 6 lines
Do we need to send the non-PV guest a signal of any kind to kill it? After all, we can stop it running any further instructions (and perhaps
avoid the use of bad data) by deciding within the HV or dom0 simply to abort that guest. There is no loss to diagnosability since the HV/dom0 combination is doing that, anyway.
No, HV can "kill" a guest without notifying the guest - in worst case, it may need to pause the physical CPU that may still be running on the guest (e.g. we have multiple CPU's, one of them got "bad data", but other CPU's are still processing stuff). But the pausing of the CPU is a "in hypervisor" function, so still no need to tell the guest anything - just "Bang, you're dead" type thing.
Quoted 14 lines
Quoted 2 lines
Emulating MCE to the guest wasn't my intended alternative
suggestion. Instead,
Quoted 1 line
my idea was that if the guest hasn't registered a "PV MCE
handler", we just
Quoted 1 line
immediately kill the domain as such - e.g similar to
"
domain_crash_synchronous()".Quoted 1 line
Don't let the guest have any chance to "do something
wrong" in the process - it's
Quoted 1 line
already broken, and letting it run any further will almost
certainly not help matters.
Quoted 1 line
This may not be the prettiest solution, but then on the
other hand, a "Windows blue-screen"
Quoted 1 line
or Linux "oops" saying GP fault happened at some random
Quoted 8 lines
place in the guest isn't exactly
Quoted 1 line
helping the SysAdmin understand the problem either.
Agreed - don't let the affected guest run one more instruction if we can. Sysadmins
will learn to consult dom0 diagnostics to see if they explain any sudden guest deaths -
no need, as you say, to splurge any raw error data to them.
Exactly, particularly when it's bogus raw error data, that isn't actually caused by the original problem.
--
Mats
Quoted 41 lines
Gavin
Quoted 32 lines
--
MatsQuoted 28 lines
Keir, what are your opinions on this thread?
Christoph
Signature · 19 lines
AMD Saxony, Dresden, Germany Operating System Research Center Legal Information: AMD Saxony Limited Liability Company & Co. KG Sitz (Geschäftsanschrift): Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland Registergericht Dresden: HRA 4896 vertretungsberechtigter Komplementär: AMD Saxony LLC (Sitz Wilmington, Delaware, USA) Geschäftsführer der AMD Saxony LLC: Dr. Hans-R. Deppe, Thomas McCoy _______________________________________________ Xen-devel mailing list [email protected] http://lists.xensource.com/xen-develSignature · 1 line
Gavin Maltby, Solaris Kernel Development.
Hi,
Quoted 10 lines · Christoph Egger
Quoted 9 lines · On Wednesday 30 May 2007 10:49:40 Jan Beulich wrote:
Quoted 9 lines
Quoted 1 line
Quoted 1 line
"Christoph Egger" <[email protected]> 30.05.07 09:45 >>>
Quoted 7 lines · On Wednesday 30 May 2007 09:19:12 Jan Beulich wrote:
Quoted 7 lines
case I) - Xen reveives a MCE from the CPU
1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose
[rest cut]
For the hypervisor to dom0 communication that 2a) above refers to I think we need to agree on two aspects: what form the notification event will take, and what error telemetry data and additional information will be provided by the hypervisor for dom0 to chew on for statistical and diagnosis purposes.
For the first I've assumed so far that an event channel notification of the MCA event will suffice; as long as the hypervisor only polls for correctable MCA errors at a low-frequency rate (currently 15s interval) there is no danger of spamming that single notification. On receipt of the notification the event handler will need to suck some event data out of somewhere - uncertain which somewhere would be best?
We should standardize both the format and the content of this event data. The following is just to get the conversation started in this area.
Content first. Obviously we need the raw MCA register content - MCi_STATUS, MCi_ADDR, MCi_MISC. We also need know which MCA detector bank made the observation, so we need to include some indication of which chip (where I use "chip" to coincide with "socket"), core on that chip, and MCA bank number the telemetry came from. I think I am correct in saying that hyperthreaded CPUs do not have any MCA banks per-thread, but we may want to allow for that future possibility (I know, for instance, that some SPARC cpus have error state for each hardware thread).
Such specification of error detector information clearly requires some namespace specification. For example if the detector identifier could naturally come out of Xen as a (chip, core, thread, bank) there needs to be a clear understanding of how chips, cores etc are numbered in Xen and how dom0 that matches with how the dom0 OS has numbered these things. If instead the detector identifier were something like a (physical-cpu, bank) using the Xen physical-cpu enumeration then dom0 may need a mechanism to resolve this into chip etc info - you can't just work with physical cpus since, for example, a chip-shared L3 cache spans multiple physical cpus.
We should also allow for additional model-specific error telemetry that may be available and relevant - I know that will be necessary for some upcoming x86 cpu models. We should probably avoid adding "cooked" content to this error event payload - such cooking of the raw data is much more easily performed in dom0 (the example I'm thinking of here is physical address to memory location translation).
In terms of the form of the error event data, the simplest but also the dumbest would be a binary structure passed from hypervisor to dom0:
struct mca_error_data_ver1 {
uint8_t version; /* structure version */
uint64_t status;
uint64_t addr;
uint64_t misc;
uint16_t chip;
uint16_t core;
uint16_t bank;
...
};That is easily passed around and can be extended by versioning. A more self-describing and naturally extensible approach would be to parcel the error data in some form of name-type-value list. That's what we do in the corresponding kernel->userland error code in Solaris; the downside is that the supporting libnvpair library is not tiny and likely not the sort of footprint to include in a hypervisor. Perhaps some cut-down form would do.
Thoughts?
Gavin
Quoted 15 lines · On Monday 04 June 2007 18:16:56 Gavin Maltby wrote:
Hi,
Quoted 11 lines · Christoph Egger
Quoted 10 lines · On Wednesday 30 May 2007 10:49:40 Jan Beulich wrote:
Quoted 10 lines
Quoted 1 line
Quoted 1 line
"Christoph Egger" <[email protected]> 30.05.07 09:45 >>>
Quoted 7 lines · On Wednesday 30 May 2007 09:19:12 Jan Beulich wrote:
Quoted 7 lines
case I) - Xen reveives a MCE from the CPU
1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose
Quoted 7 lines
[rest cut]
For the hypervisor to dom0 communication that 2a) above refers to I think we need to agree on two aspects: what form the notification event will take, and what error telemetry data and additional information will be provided by the hypervisor for dom0 to chew on for statistical and diagnosis purposes.
Additionally, the hypervisor must be able to notify domU that has a PV MCA driver.
Quoted 4 lines
For the first I've assumed so far that an event channel notification of the MCA event will suffice; as long as the hypervisor only polls for correctable MCA errors at a low-frequency rate (currently 15s interval) there is no danger of spamming that single notification.
Why polling?
Quoted 8 lines
On receipt of the notification the event handler will need to suck some event data out of somewhere - uncertain which somewhere would be best?
We should standardize both the format and the content of this event data. The following is just to get the conversation started in this area.
Quoted 9 lines
Content first. Obviously we need the raw MCA register content -
MCi_STATUS,MCi_ADDR,MCi_MISC. We also need know which MCA detector bank made the observation, so we need to include some indication of which chip (where I use "chip" to coincide with "socket"), core on that chip, and MCA bank number the telemetry came from. I think I am correct in saying that hyperthreaded CPUs do not have any MCA banks per-thread, but we may want to allow for that future possibility (I know, for instance, that some SPARC cpus have error state for each hardware thread).
And we need the domain and the domain's vcpu to identify who is impacted.
Quoted 11 lines
We should also allow for additional model-specific error telemetry that may be available and relevant - I know that will be necessary for some upcoming x86 cpu models. We should probably avoid adding "cooked" content to this error event payload - such cooking of the raw data is much more easily performed in dom0 (the example I'm thinking of here is physical address to memory location translation).
In terms of the form of the error event data, the simplest but also the dumbest would be a binary structure passed from hypervisor to dom0:
struct mca_error_data_ver1 {
uint8_t version; /* structure version */
uint64_t mc_status;
uint64_t mc_addr;
uint64_t mc_misc;
uint16_t mc_chip;
uint16_t mc_core;
uint16_t mc_bank;
uint16_t domid;
uint16_t vcpu_id; ...
};
Quoted 7 lines
That is easily passed around and can be extended by versioning. A more self-describing and naturally extensible approach would be to parcel the error data in some form of name-type-value list. That's what we do in the corresponding
kernel->userlanderror code in Solaris; the downside is that the supporting libnvpair library is not tiny and likely not the sort of footprint to include in a hypervisor. Perhaps some cut-down form would do.
In the public xen.h header is a VIRQ_DOM_EXC defined, which seems to be appropriate for an NMI event.
There are two functions to send VIRQs: send_guest_vcpu_virq() and send_guest_global_virq().
However, VIRQ_DOM_EXC is not properly implemented:
All virtual interrupts are maskable. We definitely need
an event that guarantees to immediately interrupts the guest, no matter if this is Dom0 or DomU and whatever they are doing.
And VIRQ_DOM_EXC is explicitely reserved for Dom0. Maybe
we should introduce a VIRQ_MCA as a special NMI event for both Dom0 and DomU?
Christoph
Signature · 12 lines
AMD Saxony, Dresden, Germany Operating System Research Center Legal Information: AMD Saxony Limited Liability Company & Co. KG Sitz (Geschäftsanschrift): Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland Registergericht Dresden: HRA 4896 vertretungsberechtigter Komplementär: AMD Saxony LLC (Sitz Wilmington, Delaware, USA) Geschäftsführer der AMD Saxony LLC: Dr. Hans-R. Deppe, Thomas McCoy
Hi,
Quoted 16 lines · Christoph Egger
Quoted 15 lines · On Monday 04 June 2007 18:16:56 Gavin Maltby wrote:
Hi,
Quoted 10 lines · Christoph Egger
Quoted 9 lines · On Wednesday 30 May 2007 10:49:40 Jan Beulich wrote:
Quoted 9 lines
Quoted 1 line
Quoted 1 line
"Christoph Egger" <[email protected]> 30.05.07 09:45 >>>
Quoted 7 lines · On Wednesday 30 May 2007 09:19:12 Jan Beulich wrote:
Quoted 7 lines
case I) - Xen reveives a MCE from the CPU
1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose[rest cut]
Quoted 8 lines
Quoted 5 lines
For the hypervisor to dom0 communication that 2a) above refers to I think we need to agree on two aspects: what form the notification event will take, and what error telemetry data and additional information will be provided by the hypervisor for dom0 to chew on for statistical and diagnosis purposes.
Additionally, the hypervisor must be able to notify domU that has a PV MCA driver.
Yes, forgot that; although I guess I view that most likely as a future phase.
Quoted 6 lines
Quoted 4 lines
For the first I've assumed so far that an event channel notification of the MCA event will suffice; as long as the hypervisor only polls for correctable MCA errors at a low-frequency rate (currently 15s interval) there is no danger of spamming that single notification.
Why polling?
Polling for correctable errors, but #MC as usual for others. Setting MCi_CTL bits for correctable errors does not produce a machine check, so polling is the only approach unless one sets additional (and undocumented, certainly for AMD chips) config bits. What I was getting at here is that polling at largish intervals for correctables is the correct approach - trapping for them or polling at a high-frequency is bad because in cases where you have some form of solid correctable error (say a single bad pin in a dimm socket affecting one or two ranks of that dimm but never able to produce a UE) the trap handling and diagnosis software consume the machine and things make little useful forward progress.
Quoted 18 lines
Quoted 8 lines
On receipt of the notification the event handler will need to suck some event data out of somewhere - uncertain which somewhere would be best?
We should standardize both the format and the content of this event data. The following is just to get the conversation started in this area.
Quoted 9 lines
Content first. Obviously we need the raw MCA register content -
MCi_STATUS,MCi_ADDR,MCi_MISC. We also need know which MCA detector bank made the observation, so we need to include some indication of which chip (where I use "chip" to coincide with "socket"), core on that chip, and MCA bank number the telemetry came from. I think I am correct in saying that hyperthreaded CPUs do not have any MCA banks per-thread, but we may want to allow for that future possibility (I know, for instance, that some SPARC cpus have error state for each hardware thread).
Quoted 2 lines
And we need the domain and the domain's vcpu to identify who is impacted.
Yes, the domain ID. I'm not sure we need the vcpu id if we instead present some physical identifiers such as chip, core number etc (and have the namespaces well-defined). If we don't present those the vcpu in the payload and some external method to resolve that to physical components. Since errors correlate to physical components it would, I think, be nicer to report detector info in some physical sense.
As regards a vcpu to physical translation, I didn't think there was any fixed mapping (or certainly any mapping that a dom0 should interpret and rely on). For example if we have two physical cores but choose to present 32 vcpus to domain I don't believe there is anything to say that 0-15 map always run on physical core 0?
Quoted 36 lines
Quoted 11 lines
We should also allow for additional model-specific error telemetry that may be available and relevant - I know that will be necessary for some upcoming x86 cpu models. We should probably avoid adding "cooked" content to this error event payload - such cooking of the raw data is much more easily performed in dom0 (the example I'm thinking of here is physical address to memory location translation).
In terms of the form of the error event data, the simplest but also the dumbest would be a binary structure passed from hypervisor to dom0:
struct
mca_error_data_ver1{(quoted diff) +0
-0uint8_t version; /* structure version */ uint64_t mc_status; uint64_t mc_addr; uint64_t mc_misc; uint16_t mc_chip; uint16_t mc_core; uint16_t mc_bank; uint16_t domid; uint16_t vcpu_id;};
Quoted 7 lines
That is easily passed around and can be extended by versioning. A more self-describing and naturally extensible approach would be to parcel the error data in some form of name-type-value list. That's what we do in the corresponding
kernel->userlanderror code in Solaris; the downside is that the supporting libnvpair library is not tiny and likely not the sort of footprint to include in a hypervisor. Perhaps some cut-down form would do.In the public
xen.hheader is aVIRQ_DOM_EXCdefined, which seems
to be appropriate for an NMI event.
There are two functions to send VIRQs:send_guest_vcpu_virq()andsend_guest_global_virq().
Quoted 7 lines
However,
VIRQ_DOM_EXCis not properly implemented:
All virtual interrupts are maskable. We definitely need
an event that guarantees to immediately interrupts the guest, no matter if this is Dom0 or DomU and whatever they are doing.And
VIRQ_DOM_EXCis explicitely reserved for Dom0. Maybe
we should introduce aVIRQ_MCAas a special NMI event for both Dom0 and DomU?
Sounds like it may be necessary. I don't know this mechanism very well so I'll go and do some reading (after a big long unrelated codereview).
Cheers
Gavin
Quoted 27 lines · On Wednesday 06 June 2007 12:35:15 Gavin Maltby wrote:
Hi,
Quoted 24 lines · Christoph Egger
Quoted 22 lines · On Monday 04 June 2007 18:16:56 Gavin Maltby wrote:
Hi,
Quoted 11 lines · Christoph Egger
Quoted 10 lines · On Wednesday 30 May 2007 10:49:40 Jan Beulich wrote:
Quoted 10 lines
Quoted 1 line
Quoted 1 line
"Christoph Egger" <[email protected]> 30.05.07 09:45 >>>
Quoted 7 lines · On Wednesday 30 May 2007 09:19:12 Jan Beulich wrote:
Quoted 7 lines
case I) - Xen reveives a MCE from the CPU
1) Xen MCE handler figures out if error is an correctable error (CE) or uncorrectable error (UE)
2a) error == CE:
Xen notifies Dom0 if Dom0 installed an MCA event handler for statistical purpose[rest cut]
For the hypervisor to dom0 communication that 2a) above refers to I think we need to agree on two aspects: what form the notification event will take, and what error telemetry data and additional information will be provided by the hypervisor for dom0 to chew on for statistical and diagnosis purposes.
Quoted 5 lines
Quoted 2 lines
Additionally, the hypervisor must be able to notify domU that has a PV MCA driver.
Yes, forgot that; although I guess I view that most likely as a future phase.
Yes, but ignoring this can lead to a design that is bad for DomU and requires a re-design in the worst case.
Quoted 7 lines
Quoted 6 lines
Quoted 4 lines
For the first I've assumed so far that an event channel notification of the MCA event will suffice; as long as the hypervisor only polls for correctable MCA errors at a low-frequency rate (currently 15s interval) there is no danger of spamming that single notification.
Why polling?
Quoted 11 lines
Polling for correctable errors, but #MC as usual for others. Setting
MCi_CTLbits for correctable errors does not produce a machine check, so polling is the only approach unless one sets additional (and undocumented, certainly for AMD chips) config bits. What I was getting at here is that polling at largish intervals for correctables is the correct approach - trapping for them or polling at a high-frequency is bad because in cases where you have some form of solid correctable error (say a single bad pin in a dimm socket affecting one or two ranks of that dimm but never able to produce a UE) the trap handling and diagnosis software consume the machine and things make little useful forward progress.
I still don't see, why #MC for all kind of errors is bad.
Quoted 21 lines
Quoted 18 lines
Quoted 8 lines
On receipt of the notification the event handler will need to suck some event data out of somewhere - uncertain which somewhere would be best?
We should standardize both the format and the content of this event data. The following is just to get the conversation started in this area.
Quoted 9 lines
Content first. Obviously we need the raw MCA register content -
MCi_STATUS,MCi_ADDR,MCi_MISC. We also need know which MCA detector bank made the observation, so we need to include some indication of which chip (where I use "chip" to coincide with "socket"), core on that chip, and MCA bank number the telemetry came from. I think I am correct in saying that hyperthreaded CPUs do not have any MCA banks per-thread, but we may want to allow for that future possibility (I know, for instance, that some SPARC cpus have error state for each hardware thread).Quoted 2 lines
And we need the domain and the domain's vcpu to identify who is impacted.
Quoted 6 lines
Yes, the domain ID. I'm not sure we need the vcpu id if we instead present some physical identifiers such as chip, core number etc (and have the namespaces well-defined). If we don't present those the vcpu in the payload and some external method to resolve that to physical components. Since errors correlate to physical components it would, I think, be nicer to report detector info in some physical sense.
The vcpu is more interesting for the domU than for dom0. See below.
Quoted 48 lines
As regards a vcpu to physical translation, I didn't think there was any fixed mapping (or certainly any mapping that a dom0 should interpret and rely on). For example if we have two physical cores but choose to present 32 vcpus to domain I don't believe there is anything to say that 0-15 map always run on physical core 0?
Quoted 42 lines
Quoted 10 lines
We should also allow for additional model-specific error telemetry that may be available and relevant - I know that will be necessary for some upcoming x86 cpu models. We should probably avoid adding "cooked" content to this error event payload - such cooking of the raw data is much more easily performed in dom0 (the example I'm thinking of here is physical address to memory location translation).
In terms of the form of the error event data, the simplest but also the dumbest would be a binary structure passed from hypervisor to dom0:
struct
mca_error_data_ver1{(quoted diff) +0
-0uint8_t version; /* structure version */ uint64_t mc_status; uint64_t mc_addr; uint64_t mc_misc; uint16_t mc_chip; uint16_t mc_core; uint16_t mc_bank; uint16_t domid; uint16_t vcpu_id;};
Quoted 7 lines
That is easily passed around and can be extended by versioning. A more self-describing and naturally extensible approach would be to parcel the error data in some form of name-type-value list. That's what we do in the corresponding
kernel->userlanderror code in Solaris; the downside is that the supporting libnvpair library is not tiny and likely not the sort of footprint to include in a hypervisor. Perhaps some cut-down form would do.In the public
xen.hheader is aVIRQ_DOM_EXCdefined, which seems to be appropriate for an NMI event.
There are two functions to send VIRQs:send_guest_vcpu_virq()andsend_guest_global_virq().However,
VIRQ_DOM_EXCis not properly implemented:
All virtual interrupts are maskable. We definitely need
an event that guarantees to immediately interrupts the guest, no matter if this is Dom0 or DomU and whatever they are doing.
Quoted 6 lines
Quoted 3 lines
And
VIRQ_DOM_EXCis explicitely reserved for Dom0. Maybe
we should introduce aVIRQ_MCAas a special NMI event for both Dom0 and DomU?Sounds like it may be necessary. I don't know this mechanism very well so I'll go and do some reading (after a big long unrelated codereview).
After some code reading I found a nmi_pending, nmi_masked and nmi_addr in struct vcpu in xen/include/xen/sched.h. xen/include/xen/nmi.h is also of interest. The implementation is in xen/common/kernel.c.
There is only one callback per vcpu allowed and only Dom0 can register an NMI. So the guests NMI handler must multiplex several nmi handlers - at least for Dom0 (MCA + watchdog timer). It's fine with me to allow DomUs to only register the MCA NMI.
To inform domU (having a PV MCA driver), they must be able to register an NMI callback as well. To allow this, struct vcpu_info in the PUBLIC xen.h also needs nmi_pending and nmi_addr.
Keir: How do you feel about all this? Is this the right way or do you see things that should be done in a different way?
Christoph
Signature · 12 lines
AMD Saxony, Dresden, Germany Operating System Research Center Legal Information: AMD Saxony Limited Liability Company & Co. KG Sitz (Geschäftsanschrift): Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland Registergericht Dresden: HRA 4896 vertretungsberechtigter Komplementär: AMD Saxony LLC (Sitz Wilmington, Delaware, USA) Geschäftsführer der AMD Saxony LLC: Dr. Hans-R. Deppe, Thomas McCoy
Hi,
Quoted 17 lines · Christoph Egger
Quoted 5 lines
Quoted 5 lines
Quoted 4 lines
For the first I've assumed so far that an event channel notification of the MCA event will suffice; as long as the hypervisor only polls for correctable MCA errors at a low-frequency rate (currently 15s interval) there is no danger of spamming that single notification.
Why polling?
Quoted 11 lines
Polling for correctable errors, but #MC as usual for others. Setting
MCi_CTLbits for correctable errors does not produce a machine check, so polling is the only approach unless one sets additional (and undocumented, certainly for AMD chips) config bits. What I was getting at here is that polling at largish intervals for correctables is the correct approach - trapping for them or polling at a high-frequency is bad because in cases where you have some form of solid correctable error (say a single bad pin in a dimm socket affecting one or two ranks of that dimm but never able to produce a UE) the trap handling and diagnosis software consume the machine and things make little useful forward progress.
Quoted 1 line
I still don't see, why #MC for all kind of errors is bad.
I'm talking about whether the hypervisor takes a machine check for an error or polls for it. We do not want #MC for correctable errors stopping the hypervisor from making progress. And if the hypervisor poll interval was to small a solid error would again keep the hypervisor busy producing (mostly/all duplicate) error telemetry and the diagnosis code in dom0 would burn cpu cycles, too.
How errors observed by the hypervisor, be they from #MC or from a poll, are propogated to the domains is unimportant from this point of view - e.g., if we decide to take error telemetry discovered via a poll in the hypervisor and propogate it to the domain pretending it is undistinguishable from a machine check that will not hurt or limit the domain processing.
An untested design I had in mind, unashamedly influenced by what we do in Solaris, was to have some common memory shared between hypervisor and domain into which the hypervisor produces error telemetry and the domain consumes that telemetry. Producing and consuming is lockless using compare-and-swap. There are two queues in this shared memory - one for uncorrectable error telemetry and one for correctable error telemetry. When the domain gets whatever event to notify it of telemetry for processing it processes the queues; the event would be synchronous for uncorrectable errors (ie, domain must process the telemetry right now) or asynchronous in the case of correctable errors (process when convenient). The separation of CE and UE queues stops CEs from flooding the more important UE events (you can always drop CEs if there is no more space, but you can never drop UEs).
[cut]
Quoted 1 line
After some code reading I found a
nmi_pending,nmi_maskedandnmi_addrin
[cut]
Still chewing on that ...
Cheers
Gavin
Quoted 39 lines · On Wednesday 06 June 2007 14:25:26 Gavin Maltby wrote:
Hi,
Quoted 19 lines · Christoph Egger
Quoted 7 lines
Quoted 6 lines
Quoted 4 lines
For the first I've assumed so far that an event channel notification of the MCA event will suffice; as long as the hypervisor only polls for correctable MCA errors at a low-frequency rate (currently 15s interval) there is no danger of spamming that single notification.
Why polling?
Quoted 11 lines
Polling for correctable errors, but #MC as usual for others. Setting
MCi_CTLbits for correctable errors does not produce a machine check, so polling is the only approach unless one sets additional (and undocumented, certainly for AMD chips) config bits. What I was getting at here is that polling at largish intervals for correctables is the correct approach - trapping for them or polling at a high-frequency is bad because in cases where you have some form of solid correctable error (say a single bad pin in a dimm socket affecting one or two ranks of that dimm but never able to produce a UE) the trap handling and diagnosis software consume the machine and things make little useful forward progress.Quoted 1 line
I still don't see, why #MC for all kind of errors is bad.
I'm talking about whether the hypervisor takes a machine check for an error or polls for it. We do not want #MC for correctable errors stopping the hypervisor from making progress. And if the hypervisor poll interval was to small a solid error would again keep the hypervisor busy producing (mostly/all duplicate) error telemetry and the diagnosis code in dom0 would burn cpu cycles, too.
How errors observed by the hypervisor, be they from #MC or from a poll, are propogated to the domains is unimportant from this point of view - e.g., if we decide to take error telemetry discovered via a poll in the hypervisor and propogate it to the domain pretending it is undistinguishable from a machine check that will not hurt or limit the domain processing.
Quoted 4 lines
An untested design I had in mind, unashamedly influenced by what we do in Solaris, was to have some common memory shared between hypervisor and domain into which the hypervisor produces error telemetry and the domain consumes that telemetry.
That is the struct vcpu_info in the PUBLIC xen.h. It is accessable in the hypervisor as well as in the guest.
Quoted 11 lines
Producing and consuming is lockless using compare-and-swap. There are two queues in this shared memory - one for uncorrectable error telemetry and one for correctable error telemetry. When the domain gets whatever event to notify it of telemetry for processing it processes the queues; the event would be synchronous for uncorrectable errors (ie, domain must process the telemetry right now) or asynchronous in the case of correctable errors (process when convenient). The separation of CE and UE queues stops CEs from flooding the more important UE events (you can always drop CEs if there is no more space, but you can never drop UEs).
So we use the asynchronous event mechanism VIRQ_DOM_EXC to report correctable errors to the Dom0 and the nmi stuff for uncorrectable errors to Dom0 and DomU, right?
The fact that VIRQ_DOM_EXC is for Dom0 only doesn't hurt here, since we never report CEs to DomUs.
Quoted 7 lines
[cut]
Quoted 1 line
After some code reading I found a
nmi_pending,nmi_maskedandnmi_addrin[cut]
Still chewing on that ...
Christoph
Signature · 12 lines
AMD Saxony, Dresden, Germany Operating System Research Center Legal Information: AMD Saxony Limited Liability Company & Co. KG Sitz (Geschäftsanschrift): Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland Registergericht Dresden: HRA 4896 vertretungsberechtigter Komplementär: AMD Saxony LLC (Sitz Wilmington, Delaware, USA) Geschäftsführer der AMD Saxony LLC: Dr. Hans-R. Deppe, Thomas McCoy
Quoted 17 lines · Christoph Egger
Quoted 4 lines · On Monday 04 June 2007 18:16:56 Gavin Maltby wrote:
In terms of the form of the error event data, the simplest but also the dumbest would be a binary structure passed from hypervisor to dom0:
struct
mca_error_data_ver1{(quoted diff) +0
-0uint8_t version; /* structure version */ uint64_t mc_status; uint64_t mc_addr; uint64_t mc_misc; uint16_t mc_chip; uint16_t mc_core; uint16_t mc_bank; uint16_t domid; uint16_t vcpu_id;
Quoted 1 line
};
Since there are multiple MCA detector banks, and more than one may have logged a valid error, we need to think about communicating all the bank error telemetry. This should also allow for there being varying numbers of MCA banks in different proccessor types. So something like
struct {
uint8_t version;
uint8_t nbanks;
uint16_t flags;
uint16_t domid;
uint16_t vcpud_id; /* if meaningful? */
uint8_t chipid;
uint8_t coreid;
uint64_t mcg_status;
struct {
mc_status;
mc_addr;
mc_misc;
} bank[1];
};The bank array is actually sized as per nbanks.
I've added mcg_status and flags. The latter I'd like to use for indicators such as "this error data was artificially injected" etc.
Gavin
Quoted 41 lines · On Thursday 14 June 2007 13:59:12 Gavin Maltby wrote:
Quoted 16 lines · Christoph Egger
Quoted 3 lines · On Monday 04 June 2007 18:16:56 Gavin Maltby wrote:
In terms of the form of the error event data, the simplest but also the dumbest would be a binary structure passed from hypervisor to dom0:
struct
mca_error_data_ver1{(quoted diff) +0
-0uint8_t version; /* structure version */ uint64_t mc_status; uint64_t mc_addr; uint64_t mc_misc; uint16_t mc_chip; uint16_t mc_core; uint16_t mc_bank; uint16_t domid; uint16_t vcpu_id;Quoted 1 line
};
Since there are multiple MCA detector banks, and more than one may have logged a valid error, we need to think about communicating all the bank error telemetry. This should also allow for there being varying numbers of MCA banks in different proccessor types. So something like
struct { uint8_t version; uint8_t nbanks; uint16_t flags; uint16_t domid; uint16_t vcpud_id; /* if meaningful? */ uint8_t chipid; uint8_t coreid; uint64_t mcg_status; struct { mc_status; mc_addr; mc_misc; } bank[1]; };
Quoted 5 lines
The bank array is actually sized as per nbanks.
I've added
mcg_statusand flags. The latter I'd like to use for indicators such as "this error data was artificially injected" etc.
Here is my proposal for a real exensible event structure:
#define MCA_TYPE_COMMON 0
#define MCA_TYPE_BANK 1
#define MCA_TYPE_ALLBANKS 2
...
#define MCA_COMMON \
size_t size; /* size of this struct in bytes */ uint32_t type; /* structure type */ uint16_t domid;
uint8_t chipid;
uint8_t coreid;
uint64_t mcg_status; /* global status */
The base structure:
struct mca_event {
MCA_COMMON;
};The specific structs:
struct mca_event_bank {
MCA_COMMON;
uint16_t vcpu_id;
uint16_t mc_bank;
uint64_t mc_status;
uint64_t mc_addr;
uint64_t mc_misc;
uint32_t flags;
};
struct mca_event_allbanks {
MCA_COMMON;
uint16_t vcpud_id;
uint8_t nbanks;
uint32_t flags;
struct {
uint64_t mc_status;
uint64_t mc_addr;
uint64_t mc_misc;
} bank[1];
};
And you can have many more structs to support future features.
In the code you allocate the size of the struct you want to use:
struct mca_event *mca = malloc(sizeof(struct mca_event_bank));
mca->size = sizeof(struct mca_event_bank);
mca->type = MCA_TYPE_BANK;in this example you can cast from mca_event to mca_event_bank and back whenever you like.
The generic code only needs to know struct mca_event.
Christoph
Signature · 12 lines
AMD Saxony, Dresden, Germany Operating System Research Center Legal Information: AMD Saxony Limited Liability Company & Co. KG Sitz (Geschäftsanschrift): Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland Registergericht Dresden: HRA 4896 vertretungsberechtigter Komplementär: AMD Saxony LLC (Sitz Wilmington, Delaware, USA) Geschäftsführer der AMD Saxony LLC: Dr. Hans-R. Deppe, Thomas McCoy
Quoted 65 lines
-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of Christoph Egger
Sent: 21 June 2007 10:29
To: [email protected]
Cc: Gavin Maltby; Jan Beulich
Subject: Re: [Xen-devel] RFC: MCA/MCE conceptQuoted 3 lines · On Thursday 14 June 2007 13:59:12 Gavin Maltby wrote:
Quoted 2 lines · Christoph Egger
Quoted 1 line · On Monday 04 June 2007 18:16:56 Gavin Maltby wrote:
In terms of the form of the error event data, the
simplest but also
Quoted 38 lines
Quoted 14 lines
Quoted 2 lines
the dumbest would be a binary structure passed from hypervisor to dom0:
struct
mca_error_data_ver1{(quoted diff) +0
-0uint8_t version; /* structure version */ uint64_t mc_status; uint64_t mc_addr; uint64_t mc_misc; uint16_t mc_chip; uint16_t mc_core; uint16_t mc_bank; uint16_t domid; uint16_t vcpu_id;Quoted 1 line
};
Since there are multiple MCA detector banks, and more than one may have logged a valid error, we need to think about communicating all the bank error telemetry. This should also allow for there being varying numbers of MCA banks in different proccessor types. So something like
struct { uint8_t version; uint8_t nbanks; uint16_t flags; uint16_t domid; uint16_t vcpud_id; /* if meaningful? */ uint8_t chipid; uint8_t coreid; uint64_t mcg_status; struct { mc_status; mc_addr; mc_misc; } bank[1]; };Quoted 5 lines
The bank array is actually sized as per nbanks.
I've added
mcg_statusand flags. The latter I'd like to use for indicators such as "this error data was artificially injected" etc.Here is my proposal for a real exensible event structure:
#define
MCA_TYPE_COMMON0
#defineMCA_TYPE_BANK1
#defineMCA_TYPE_ALLBANKS2
...
Quoted 7 lines
#define
MCA_COMMON\
size_tsize; /* size of this struct in bytes */uint32_ttype; /* structure type */uint16_tdomid;
uint8_tchipid;
uint8_tcoreid;
uint64_tmcg_status; /* global status */
At this point, I'd love it if gcc supported unnamed structs! [Which it does only with -fms-extensions].
That would make this sort of thing so much neater.
Quoted 73 lines
The base structure:
struct mca_event { MCA_COMMON; };The specific structs:
struct mca_event_bank { MCA_COMMON; uint16_t vcpu_id; uint16_t mc_bank; uint64_t mc_status; uint64_t mc_addr; uint64_t mc_misc; uint32_t flags; };struct mca_event_allbanks { MCA_COMMON; uint16_t vcpud_id; uint8_t nbanks; uint32_t flags; struct {(quoted diff) +0
-0uint64_t mc_status; uint64_t mc_addr; uint64_t mc_misc; } bank[1];};
And you can have many more structs to support future features.
In the code you allocate the size of the struct you want to use:
struct mca_event *mca = malloc(sizeof(struct mca_event_bank)); mca->size = sizeof(struct mca_event_bank); mca->type = MCA_TYPE_BANK;in this example you can cast from
mca_eventtomca_event_bankand back whenever you like.
The generic code only needs to know structmca_event.Christoph
Signature · 19 lines
AMD Saxony, Dresden, Germany Operating System Research Center Legal Information: AMD Saxony Limited Liability Company & Co. KG Sitz (Geschäftsanschrift): Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland Registergericht Dresden: HRA 4896 vertretungsberechtigter Komplementär: AMD Saxony LLC (Sitz Wilmington, Delaware, USA) Geschäftsführer der AMD Saxony LLC: Dr. Hans-R. Deppe, Thomas McCoy _______________________________________________ Xen-devel mailing list [email protected] http://lists.xensource.com/xen-devel