hwmon/w83627ehf: Preserve speed reading
PATCH 1/10 hwmon/w83627ehf: Preserve speed reading
The w83627ehf driver changes the fan clock divider automatically when a new min fan speed is set. It is supposed to preserve the fan speed reading while doing so, but doesn't really. Fix it.
Signed-off-by Jean Delvare <[email protected]>
--- drivers/hwmon/w83627ehf.c | 13 +++++++++---- 1 file changed, 9 insertions(+), 4 deletions(-)
drivers/hwmon/w83627ehf.c +9 -4
@@ -716,10 +716,15 @@ store_fan_min(struct device *dev, struct/* Write both the fan clock divider (if it changed) and the new fan min (unconditionally) */ if (new_div != data->fan_div[nr]) { -if (new_div > data->fan_div[nr]) - data->fan[nr] >>= (data->fan_div[nr] - new_div); -else - data->fan[nr] <<= (new_div - data->fan_div[nr]); +/* Preserve the fan speed reading */ +if (data->fan[nr] !=0xff ) { +if (new_div > data->fan_div[nr]) + data->fan[nr] >>= new_div - data->fan_div[nr]; +else if (data->fan[nr] &0x80 ) + data->fan[nr] =0xff ; +else + data->fan[nr] <<= data->fan_div[nr] - new_div; + } dev_dbg(dev, "fan%u clock divider changed from %u to %u\n", nr + 1, div_from_reg(data->fan_div[nr]),
Signature · 6 lines
Jean Delvare _______________________________________________ lm-sensors mailing list [email protected] http://lists.lm-sensors.org/mailman/listinfo/lm-sensors