cluster/fence/man fence.8 fenced.8 fence_tool. ...
CVSROOT: /cvs/cluster
Module name: cluster
Changes by: teigland at sourceware.org 2007-08-15 21:09:01
Modified files:
fence/man : fence.8 fenced.8 fence_tool.8 fence_node.8
Log message:
Update fence, fenced, fence_tool and fence_node man pages which were stuck in the RHEL4 era.
Patches:
http://sourceware.org/cgi-bin/cvsweb.cgi/cluster/fence/man/fence.8.diff?cvsroot=cluster&r1=1.6&r2=1.7
http://sourceware.org/cgi-bin/cvsweb.cgi/cluster/fence/man/fenced.8.diff?cvsroot=cluster&r1=1.4&r2=1.5
http://sourceware.org/cgi-bin/cvsweb.cgi/cluster/fence/man/fence_tool.8.diff?cvsroot=cluster&r1=1.8&r2=1.9
http://sourceware.org/cgi-bin/cvsweb.cgi/cluster/fence/man/fence_node.8.diff?cvsroot=cluster&r1=1.8&r2=1.9
fence/man/fence.8 +3 -39
@@ -28,46 +28,10 @@ Manages fenced .TP fence_node -Calls the fence agent specified in the configuration file - -.SS I/O Fencing agents - -.TP 20 -fence_apc -for APC MasterSwitch and APC 79xx models -.TP -fence_bladecenter -for IBM Bladecenters w/ telnet interface -.TP -fence_brocade -for Brocade fibre channel switches (PortDisable) -.TP -fence_egenera -for Egenera blades -.TP -fence_gnbd -for GNBD-based GFS clusters -.TP -fence_ilo -for HP ILO interfaces (formerly fence_rib) -.TP -fence_manual -for manual intervention -.TP -fence_mcdata -for McData fibre channel switches -.TP -fence_ack_manual -for manual intervention -.TP -fence_sanbox2 -for Qlogic SAN Box fibre channel switches -.TP -fence_vixel -for Vixel switches (PortDisable) +Runs the fence agent configured (per cluster.conf) for the given node. .TP -fence_wti -for WTI Network Power Switch +fence_* +Fence agents run by fenced. .SH SEE ALSO gnbd(8), gfs(8)
fence/man/fenced.8 +79 -47
175 lines not on this page · raw message
fence/man/fence_tool.8 +10 -28
@@ -13,34 +13,22 @@ .SH SYNOPSIS .B fence_tool -<\fBjoin | leave | wait\fP> +<\fBjoin | leave | dump\fP> [\fIOPTION\fR]... .SH DESCRIPTION \fBfence_tool\fP is a program used to join or leave the default fence -domain. Specifically, it starts the fence daemon (fenced) to join the -domain and kills fenced to leave the domain. Fenced can be started -and stopped directly without using this program, but fence_tool takes -some added steps that are often helpful. +domain. It communicates with the fenced daemon. Before telling fenced +to join the domain, fence_tool waits for the cluster to have quorum, +making it easier to cancel the command if the cluster is inquorate. -Before joining or leaving the fence domain, fence_tool waits for the -cluster be in a quorate state. The user can cancel fence_tool while it's -waiting for quorum. It's generally nicer to block waiting for quorum here -than to have the fence daemon itself waiting to join or leave the domain -while the cluster is inquorate. - -Since \fBfence_tool join\fP is the usual way of starting fenced, the -fenced options -j, -f, and -c can also be passed to fence_tool which -passes them on to fenced. - -A node must not leave the fence domain (fenced must not be terminated) -while CLVM or GFS are in use. +The dump option will read fenced's ring buffer of debug messages and print +it to stdout. .SH OPTIONS .TP \fB-w\fP -Wait until the join is completed. "fence_tool join -w" is -equivalent to "fence_tool join; fence_tool wait" +Wait until the join or leave is completed. .TP \fB-h\fP Help. Print out the usage syntax.
@@ -48,17 +36,11 @@ \fB-V\fP Print version information. .TP -\fB-j\fP \fIsecs\fP -Post-join fencing delay (passed to fenced) -.TP -\fB-f\fP \fIsecs\fP -Post-fail fencing delay (passed to fenced) -.TP -\fB-c\fP -All nodes are in a clean state to start (passed to fenced) -.TP \fB-t\fP Maximum time in seconds to wait (default: 300 seconds) +.TP +\fB-Q\fP +Fail command immediately if the cluster is not quorate, don't wait. .SH SEE ALSO fenced(8), fence(8), fence_node(8)
fence/man/fence_node.8 +3 -5
@@ -16,11 +16,9 @@ [\fIOPTION\fR]... .SH DESCRIPTION -\fBfence_node\fP is a program which accumulates all the necessary information -for I/O fencing a particular node and then performs the fencing action by -issuing a call to the proper fencing agent. \fBfence_node\fP gets the -necessary information from the Cluster Configuration System (CCS). CCS must -be running and properly configured for \fBfence_node\fP to work properly. +\fBfence_node\fP is a program that reads the fencing settings from +cluster.conf (through libccs/ccsd) for the given node and then runs the +configured fencing agent against the node. .SH OPTIONS .TP