Marvell PHY m88e1111 (not sure about other models, but think they too) works in two modes: fiber and copper. In Marvell PHY driver (that we have in current community kernels) code supported only copper mode, and this is not configurable, bits for copper mode are simply written in registers during PHY initialization. This patch adds support for both modes.

drivers/net/phy/marvell.c +131 -5
diff -pruN powerpc.orig/drivers/net/phy/marvell.c powerpc/drivers/net/phy/marvell.c
@@ -58,9 +58,28 @@
 #define MII_M1111_RX_DELAY		0x80
 #define MII_M1111_TX_DELAY		0x2
 #define MII_M1111_PHY_EXT_SR		0x1b
-#define MII_M1111_HWCFG_MODE_MASK	0xf
-#define MII_M1111_HWCFG_MODE_RGMII	0xb
+
+#define MII_M1111_HWCFG_MODE_MASK		0xf
+#define MII_M1111_HWCFG_MODE_COPPER_RGMII	0xb
+#define MII_M1111_HWCFG_MODE_FIBER_RGMII	0x3
 #define MII_M1111_HWCFG_MODE_SGMII_NO_CLK	0x4
+#define MII_M1111_HWCFG_FIBER_COPPER_AUTO	0x8000
+#define MII_M1111_HWCFG_FIBER_COPPER_RES	0x2000
+
+#define MII_M1111_PHY_CR		0
+#define MII_M1111_SOFTWARE_RESET	0x8000
+
+#define MII_M1111_COPPER		0
+#define MII_M1111_FIBER			1
+
+#define MII_M1011_PHY_STATUS		0x11
+#define MII_M1011_PHY_STATUS_1000	0x8000
+#define MII_M1011_PHY_STATUS_100	0x4000
+#define MII_M1011_PHY_STATUS_SPD_MASK	0xc000
+#define MII_M1011_PHY_STATUS_FULLDUPLEX	0x2000
+#define MII_M1011_PHY_STATUS_RESOLVED	0x0800
+#define MII_M1011_PHY_STATUS_LINK	0x0400
+
 
 MODULE_DESCRIPTION("Marvell PHY driver");
 MODULE_AUTHOR("Andy Fleming");
@@ -141,12 +160,22 @@ static int marvell_config_aneg(struct ph
 static int m88e1111_config_init(struct phy_device *phydev)
 {
 	int err;
+	int temp;
+	int mode;
+
+	/* Enable Fiber/Copper auto selection */
+	temp = phy_read(phydev, MII_M1111_PHY_EXT_SR);
+	temp |= MII_M1111_HWCFG_FIBER_COPPER_AUTO;
+	phy_write(phydev, MII_M1111_PHY_EXT_SR, temp);
+
+	temp = phy_read(phydev, MII_M1111_PHY_CR);
+	temp |= MII_M1111_SOFTWARE_RESET;
+	phy_write(phydev, MII_M1111_PHY_CR, temp);
 
 	if ((phydev->interface == PHY_INTERFACE_MODE_RGMII) ||
 	    (phydev->interface == PHY_INTERFACE_MODE_RGMII_ID) ||
 	    (phydev->interface == PHY_INTERFACE_MODE_RGMII_RXID) ||
 	    (phydev->interface == PHY_INTERFACE_MODE_RGMII_TXID)) {
-		int temp;
 
 		temp = phy_read(phydev, MII_M1111_PHY_EXT_CR);
 		if (temp < 0)
@@ -171,7 +200,17 @@ static int m88e1111_config_init(struct p
 			return temp;
 
 		temp &= ~(MII_M1111_HWCFG_MODE_MASK);
-		temp |= MII_M1111_HWCFG_MODE_RGMII;
+
+		mode = phy_read(phydev, MII_M1111_PHY_EXT_CR);
+		mode = (mode & MII_M1111_HWCFG_FIBER_COPPER_RES) >> 13;
+
+		switch (mode) {
+		case MII_M1111_COPPER:
+			temp |= MII_M1111_HWCFG_MODE_COPPER_RGMII;
+			break;
+		case MII_M1111_FIBER:
+			temp |= MII_M1111_HWCFG_MODE_FIBER_RGMII;
+		}
 
 		err = phy_write(phydev, MII_M1111_PHY_EXT_SR, temp);
 		if (err < 0)
@@ -262,6 +301,93 @@ static int m88e1145_config_init(struct p
 	return 0;
 }
 
+/* marvell_read_status
+ *
+ * Generic status code does not detect Fiber correctly!
+ * Description: 
+ *   Check the link, then figure out the current state
+ *   by comparing what we advertise with what the link partner
+ *   advertises.  Start by checking the gigabit possibilities,
+ *   then move on to 10/100.
+ */
+static int marvell_read_status(struct phy_device *phydev)
+{
+	int adv;
+	int err;
+	int lpa;
+	int status = 0;
+
+	/* Update the link, but return if there
+	 * was an error */
+	err = genphy_update_link(phydev);
+	if (err)
+		return err;
+
+	if (AUTONEG_ENABLE == phydev->autoneg) {
+		status = phy_read(phydev, MII_M1011_PHY_STATUS);
+		if (status < 0)
+			return status;
+
+		lpa = phy_read(phydev, MII_LPA);
+		if (lpa < 0)
+			return lpa;
+
+		adv = phy_read(phydev, MII_ADVERTISE);
+		if (adv < 0)
+			return adv;
+
+		lpa &= adv;
+
+		if (status & MII_M1011_PHY_STATUS_FULLDUPLEX)
+			phydev->duplex = DUPLEX_FULL;
+		else
+			phydev->duplex = DUPLEX_HALF;
+
+		status = status & MII_M1011_PHY_STATUS_SPD_MASK;
+		phydev->pause = phydev->asym_pause = 0;
+
+		switch (status) {
+		case MII_M1011_PHY_STATUS_1000:
+			phydev->speed = SPEED_1000;
+			break;
+
+		case MII_M1011_PHY_STATUS_100:
+			phydev->speed = SPEED_100;
+			break;
+
+		default:
+			phydev->speed = SPEED_10;
+			break;
+		}
+
+		if (phydev->duplex == DUPLEX_FULL) {
+			phydev->pause = lpa & LPA_PAUSE_CAP ? 1 : 0;
+			phydev->asym_pause = lpa & LPA_PAUSE_ASYM ? 1 : 0;
+		}
+	} else {
+		int bmcr = phy_read(phydev, MII_BMCR);
+
+		if (bmcr < 0)
+			return bmcr;
+
+		if (bmcr & BMCR_FULLDPLX)
+			phydev->duplex = DUPLEX_FULL;
+		else
+			phydev->duplex = DUPLEX_HALF;
+
+		if (bmcr & BMCR_SPEED1000)
+			phydev->speed = SPEED_1000;
+		else if (bmcr & BMCR_SPEED100)
+			phydev->speed = SPEED_100;
+		else
+			phydev->speed = SPEED_10;
+
+		phydev->pause = phydev->asym_pause = 0;
+	}
+
+	return 0;
+}
+
 static struct phy_driver marvell_drivers[] = {
 	{
 		.phy_id = 0x01410c60,
@@ -296,7 +422,7 @@ static struct phy_driver marvell_drivers
 		.flags = PHY_HAS_INTERRUPT,
 		.config_init = &m88e1111_config_init,
 		.config_aneg = &marvell_config_aneg,
-		.read_status = &genphy_read_status,
+		.read_status = &marvell_read_status,
 		.ack_interrupt = &marvell_ack_interrupt,
 		.config_intr = &marvell_config_intr,
 		.driver = { .owner = THIS_MODULE },
#1 lore raw
Quoted 5 lines · Alexandr Smirnov

Marvell PHY m88e1111 (not sure about other models, but think they too) works in two modes: fiber and copper. In Marvell PHY driver (that we have in current community kernels) code supported only copper mode, and this is not configurable, bits for copper mode are simply written in registers during PHY initialization. This patch adds support for both modes.

Excellent. I've known about this problem for a while, but haven't been able to look into it.

However, some comments below

drivers/net/phy/marvell.c line 61

Quoted 13 lines

diff -pruN powerpc.orig/drivers/net/phy/marvell.c powerpc/drivers/net/phy/marvell.c
--- powerpc.orig/drivers/net/phy/marvell.c 2008-02-07
14:59:32.000000000 +0300
+++ powerpc/drivers/net/phy/marvell.c 2008-02-19 21:47:34.000000000
+0300

drivers/net/phy/marvell.c +2 -0
@@ -58,9 +58,28 @@
 
 
+#define MII_M1111_PHY_CR		0
+#define MII_M1111_SOFTWARE_RESET	0x8000

You don't need to do this. There are already constants for both of those values. That's a standard register.

Quoted 9 lines
drivers/net/phy/marvell.c +1 -0
 MODULE_DESCRIPTION("Marvell PHY driver");
 MODULE_AUTHOR("Andy Fleming");
@@ -141,12 +160,22 @@ static int marvell_config_aneg(struct ph
 static int m88e1111_config_init(struct phy_device *phydev)
 {
 	int err;
+	int temp;

drivers/net/phy/marvell.c static int marvell_config_aneg(struct ph · line 173

Quoted 10 lines
drivers/net/phy/marvell.c +10 -0
+	int mode;
+
+	/* Enable Fiber/Copper auto selection */
+	temp = phy_read(phydev, MII_M1111_PHY_EXT_SR);
+	temp |= MII_M1111_HWCFG_FIBER_COPPER_AUTO;
+	phy_write(phydev, MII_M1111_PHY_EXT_SR, temp);
+
+	temp = phy_read(phydev, MII_M1111_PHY_CR);
+	temp |= MII_M1111_SOFTWARE_RESET;
+	phy_write(phydev, MII_M1111_PHY_CR, temp);

Use the standard constants from mii.h (MII_BMCR, and BMCR_RESET)

Quoted 6 lines
drivers/net/phy/marvell.c +1 -1
 		temp &= ~(MII_M1111_HWCFG_MODE_MASK);
-		temp |= MII_M1111_HWCFG_MODE_RGMII;
+

drivers/net/phy/marvell.c static int m88e1111_config_init(struct p · line 213

Quoted 10 lines
drivers/net/phy/marvell.c +10 -0
+		mode = phy_read(phydev, MII_M1111_PHY_EXT_CR);
+		mode = (mode & MII_M1111_HWCFG_FIBER_COPPER_RES) >> 13;
+
+		switch (mode) {
+		case MII_M1111_COPPER:
+			temp |= MII_M1111_HWCFG_MODE_COPPER_RGMII;
+			break;
+		case MII_M1111_FIBER:
+			temp |= MII_M1111_HWCFG_MODE_FIBER_RGMII;
+		}

I think using a switch statement on a single bit is probably overkill. Much clearer, I think, if you do:

mode = phy_read(phydev, MII_M1111_PHY_EXT_CR);

if (mode & MII_M1111_HWCFG_FIBER_COPPER_RES)

	temp |= MII_M1111_HWCFG_MODE_FIBER_RGMII;
else
	temp |= MII_M1111_HWCFG_MODE_COPPER_RGMII;
Quoted 4 lines

+/* marvell_read_status
+ *
+ * Generic status code does not detect Fiber correctly!

After looking at the manual for the 88e1111, I think there may be a way to continue using the generic code, rather than replicating the generic code with slightly different values. It looks like the problem isn't that Fiber disobeys the MIIM standard, but that it uses a paging mechanism to determine whether it's the Fiber Status/Control or the Copper Status/Control. Many of the registers exist in both pages, but those two don't. However, based on this, it seems reasonable to use the detected mode (fiber/copper) to determine whether we should be operating out of page 0 or 1.

Could you try making sure that register 22[7:0] = 0x1 for fiber, and see if you can then just use the standard genphy_read_status()?

Andy