hwmon: (lm90) Support the extra resolution
Subsystems (3)
PATCH 2/6 hwmon: (lm90) Support the extra resolution
The Maxim MAX6657, MAX6658 and MAX6659 have extra resolution bits for the local temperature measurement. Let the lm90 driver read them and export them to user-space.
Signed-off-by Jean Delvare <[email protected]>
---
The patch is bigger than one would think, because some re-indexing of the 8-bit temperature values was needed.
Documentation/hwmon/lm90 | 10 +++++--- drivers/hwmon/lm90.c | 54 ++++++++++++++++++++++++++++------------------ 2 files changed, 39 insertions(+), 25 deletions(-)
drivers/hwmon/lm90.c +33 -21
@@ -149,6 +149,10 @@ I2C_CLIENT_INSMOD_7(lm90, adm1032, lm99,#define LM90_REG_R_TCRIT_HYST 0x21#define LM90_REG_W_TCRIT_HYST 0x21 +/* MAX6657-specific registers */ + +#define MAX6657_REG_R_LOCAL_TEMPL 0x11 +/* * Conversions and various macros * For local temperatures and limits, critical limits and the hysteresis
@@ -219,15 +223,15 @@ struct lm90_data {int kind;/* registers values */ -s8 temp8[5 ];/* 0: local input -1: local low limit -2: local high limit -3: local critical limit -4: remote critical limit */ -s16 temp11[4 ];/* 0: remote input +s8 temp8[4 ];/* 0: local low limit +1: local high limit +2: local critical limit +3: remote critical limit */ +s16 temp11[5 ];/* 0: remote input 1: remote low limit 2: remote high limit -3: remote offset (except max6657) */ +3: remote offset (except max6657) +4: local input */ u8 temp_hyst;u8 alarms;/* bitvector */ };
@@ -265,7 +269,7 @@ static ssize_t set_temp8(struct device * data->temp8[nr] =TEMP1_TO_REG_ADT7461 (val); else data->temp8[nr] = TEMP1_TO_REG(val); -i2c_smbus_write_byte_data (client, reg[nr -1 ], data->temp8[nr]); +i2c_smbus_write_byte_data (client, reg[nr], data->temp8[nr]);mutex_unlock (&data->update_lock);return count; }
@@ -327,7 +331,7 @@ static ssize_t set_temphyst(struct deviclong hyst;mutex_lock (&data->update_lock); - hyst =TEMP1_FROM_REG (data->temp8[3 ]) - val; + hyst =TEMP1_FROM_REG (data->temp8[2 ]) - val;i2c_smbus_write_byte_data (client,LM90_REG_W_TCRIT_HYST ,HYST_TO_REG (hyst));mutex_unlock (&data->update_lock);
@@ -351,23 +355,23 @@ static ssize_t show_alarm(struct devicereturn sprintf (buf,"%d\n" , (data->alarms >> bitnr) &1 ); } -static SENSOR_DEVICE_ATTR(temp1_input, S_IRUGO, show_temp8, NULL, 0); +static SENSOR_DEVICE_ATTR(temp1_input, S_IRUGO, show_temp11, NULL, 4); static SENSOR_DEVICE_ATTR(temp2_input, S_IRUGO, show_temp11, NULL, 0); static SENSOR_DEVICE_ATTR(temp1_min, S_IWUSR | S_IRUGO, show_temp8, - set_temp8, 1); + set_temp8, 0); static SENSOR_DEVICE_ATTR(temp2_min, S_IWUSR | S_IRUGO, show_temp11, set_temp11, 1); static SENSOR_DEVICE_ATTR(temp1_max, S_IWUSR | S_IRUGO, show_temp8, - set_temp8, 2); + set_temp8, 1); static SENSOR_DEVICE_ATTR(temp2_max, S_IWUSR | S_IRUGO, show_temp11, set_temp11, 2); static SENSOR_DEVICE_ATTR(temp1_crit, S_IWUSR | S_IRUGO, show_temp8, - set_temp8, 3); + set_temp8, 2); static SENSOR_DEVICE_ATTR(temp2_crit, S_IWUSR | S_IRUGO, show_temp8, - set_temp8, 4); + set_temp8, 3); static SENSOR_DEVICE_ATTR(temp1_crit_hyst, S_IWUSR | S_IRUGO, show_temphyst, - set_temphyst, 3); -static SENSOR_DEVICE_ATTR(temp2_crit_hyst, S_IRUGO, show_temphyst, NULL, 4); + set_temphyst, 2); +static SENSOR_DEVICE_ATTR(temp2_crit_hyst, S_IRUGO, show_temphyst, NULL, 3); static SENSOR_DEVICE_ATTR(temp2_offset, S_IWUSR | S_IRUGO, show_temp11, set_temp11, 3);
@@ -772,13 +776,21 @@ static struct lm90_data *lm90_update_devu8 h, l;dev_dbg (&client->dev,"Updating lm90 data.\n" ); -lm90_read_reg (client,LM90_REG_R_LOCAL_TEMP , &data->temp8[0 ]); -lm90_read_reg (client,LM90_REG_R_LOCAL_LOW , &data->temp8[1 ]); -lm90_read_reg (client,LM90_REG_R_LOCAL_HIGH , &data->temp8[2 ]); -lm90_read_reg (client,LM90_REG_R_LOCAL_CRIT , &data->temp8[3 ]); -lm90_read_reg (client,LM90_REG_R_REMOTE_CRIT , &data->temp8[4 ]); +lm90_read_reg (client,LM90_REG_R_LOCAL_LOW , &data->temp8[0 ]); +lm90_read_reg (client,LM90_REG_R_LOCAL_HIGH , &data->temp8[1 ]); +lm90_read_reg (client,LM90_REG_R_LOCAL_CRIT , &data->temp8[2 ]); +lm90_read_reg (client,LM90_REG_R_REMOTE_CRIT , &data->temp8[3 ]);lm90_read_reg (client,LM90_REG_R_TCRIT_HYST , &data->temp_hyst); +if (data->kind = max6657) { +lm90_read16 (client,LM90_REG_R_LOCAL_TEMP , +MAX6657_REG_R_LOCAL_TEMPL , + &data->temp11[4 ]); + }else { +if (lm90_read_reg (client,LM90_REG_R_LOCAL_TEMP , + &h) =0 ) + data->temp11[4 ] = h <<8 ; + }lm90_read16 (client,LM90_REG_R_REMOTE_TEMPH ,LM90_REG_R_REMOTE_TEMPL , &data->temp11[0 ]);
Documentation/hwmon/lm90 +6 -4
@@ -86,9 +86,8 @@ family is that it features critical limi increased resolution of the remote temperature measurement. The different chipsets of the family are not strictly identical, although -very similar. This driver doesn't handle any specific feature for now, -with the exception of SMBus PEC. For reference, here comes a non-exhaustive -list of specific features: +very similar. For reference, here comes a non-exhaustive list of specific +features: LM90: * Filter and alert configuration register at 0xBF.
@@ -114,9 +113,11 @@ ADT7461: * Lower resolution for remote temperature MAX6657 and MAX6658: + * Better local resolution * Remote sensor type selection MAX6659: + * Better local resolution * Selectable address * Second critical temperature limit * Remote sensor type selection
@@ -127,7 +128,8 @@ MAX6680 and MAX6681: All temperature values are given in degrees Celsius. Resolution is 1.0 degree for the local temperature, 0.125 degree for the remote -temperature. +temperature, except for the MAX6657, MAX6658 and MAX6659 which have a +resolution of 0.125 degree for both temperatures. Each sensor has its own high and low limits, plus a critical limit. Additionally, there is a relative hysteresis value common to both critical
Signature · 6 lines
Jean Delvare _______________________________________________ lm-sensors mailing list [email protected] http://lists.lm-sensors.org/mailman/listinfo/lm-sensors