hwmon: (lm90) Don't access nonexistent
Subsystems (2)
PATCH 3/6 hwmon: (lm90) Don't access nonexistent
The Maxim chips supported by the lm90 driver have 8-bit high and low remote limit values, not 11-bit as the other chips have. So stop reading from and writing to registers that do not exist on these chips. Also round the limit values set by the user properly.
Signed-off-by Jean Delvare <[email protected]>
--- drivers/hwmon/lm90.c | 29 +++++++++++++++++++++-------- 1 file changed, 21 insertions(+), 8 deletions(-)
drivers/hwmon/lm90.c +21 -8
@@ -303,12 +303,16 @@ static ssize_t set_temp11(struct devicemutex_lock (&data->update_lock);if (data->kind = adt7461) data->temp11[nr] =TEMP2_TO_REG_ADT7461 (val); +else if (data->kind = max6657 || data->kind = max6680) + data->temp11[nr] =TEMP1_TO_REG (val) <<8 ;else data->temp11[nr] =TEMP2_TO_REG (val); +i2c_smbus_write_byte_data (client, reg[(nr -1 ) *2 ], data->temp11[nr] >>8 ); -i2c_smbus_write_byte_data (client, reg[(nr -1 ) *2 +1 ], - data->temp11[nr] &0xff ); +if (data->kind != max6657 && data->kind != max6680) +i2c_smbus_write_byte_data (client, reg[(nr -1 ) *2 +1 ], + data->temp11[nr] &0xff );mutex_unlock (&data->update_lock);return count; }
@@ -794,12 +798,21 @@ static struct lm90_data *lm90_update_devlm90_read16 (client,LM90_REG_R_REMOTE_TEMPH ,LM90_REG_R_REMOTE_TEMPL , &data->temp11[0 ]); -if (lm90_read_reg (client,LM90_REG_R_REMOTE_LOWH , &h) =0 - &&lm90_read_reg (client,LM90_REG_R_REMOTE_LOWL , &l) =0 ) - data->temp11[1 ] = (h <<8 ) | l; -if (lm90_read_reg (client,LM90_REG_R_REMOTE_HIGHH , &h) =0 - &&lm90_read_reg (client,LM90_REG_R_REMOTE_HIGHL , &l) =0 ) - data->temp11[2 ] = (h <<8 ) | l; +if (lm90_read_reg (client,LM90_REG_R_REMOTE_LOWH , &h) =0 ) { + data->temp11[1 ] = h <<8 ; +if (data->kind != max6657 && data->kind != max6680 + &&lm90_read_reg (client,LM90_REG_R_REMOTE_LOWL , + &l) =0 ) + data->temp11[1 ] |= l; + } +if (lm90_read_reg (client,LM90_REG_R_REMOTE_HIGHH , &h) =0 ) { + data->temp11[2 ] = h <<8 ; +if (data->kind != max6657 && data->kind != max6680 + &&lm90_read_reg (client,LM90_REG_R_REMOTE_HIGHL , + &l) =0 ) + data->temp11[2 ] |= l; + } +if (data->kind != max6657) {if (lm90_read_reg (client,LM90_REG_R_REMOTE_OFFSH , &h) = 0
Signature · 6 lines
Jean Delvare _______________________________________________ lm-sensors mailing list [email protected] http://lists.lm-sensors.org/mailman/listinfo/lm-sensors