Skip to contentSkip to conversation

CMD + OST FID range mapping

Lustre-devel Andreas Dilger 1 participant 1 message Apr 27, 2009 3 messages not in the archive

lore
Share & tools
lore

A message that is not in the archive (sent off-list or not yet received): [email protected]

A message that is not in the archive (sent off-list or not yet received): [email protected]

A message that is not in the archive (sent off-list or not yet received): [email protected]

#3 lore raw
Quoted 2 lines · Alex Zhuravlev

btw, I looked at interoperability page on the wiki, but haven't understood exact encoding of group:objid in fid structure. could you explain it, please?

It isn't documented on the wiki yet. My proposal is for FID-on-OST to pass the 64-bit SEQ number in the 64-bit o_gr field (similar to how we pass the MDS number there today), the main difference being that the SEQ number is a proper sequence number and assigned to a specific MDT-OST pair instead of being the same MDT index on all OSTs. Since FID-on-OST is only needed for CMD we do not need to implement this immediately. For existing objects we would use the l_ost_idx + l_object_id

Likely, we would assign a large range of SEQ numbers to each OST, and then sub-assign those to the MDTs as needed (exactly the way MDTs assign individual SEQ numbers to clients) so that the FLDB remains contiguous for the majority of uses.

Note there isn't a big problem with migrating SEQ numbers between OSTs because these numbers are not exposed to userspace in any manner that requires them to remain constant (unlink filesystem inode numbers and tar/nfs/etc). That means for normal file migrations/rebalancing we can just assign new object numbers during the migration and rewrite the LOV EA layout.

If we are doing whole-OST content migration we could consider copying the objects and migrating entire sequence numbers, but Eric pointed out to me we would likely want to do space balancing at that point anyways, so it might make sense to always just allocate new OST objects for any migration. We don't need to scan the filesystem to find the files referencing these objects, because the OST objects contain backpointers to the inodes that they are part of.

For on-the-wire usage, we can keep the OID in the low 32 bits of the obdo.o_id field, and the high 32-bit of the obdo.o_id is the VER field from the FID. That said, since we would need to special-case the seq/oid/ver mapping to the lock resource ids for "FID" vs "IDIF" values, it could go either way.

For existing objects (group == 0) we can use the l_ost_idx + l_object_id to locate it (as stored in the lov_mds_md today) and treat o_gr == 0 specially to indicate an IDIF OST FID, just as the MDT treats IGIF FIDs differently when generating a lock resource value to maintain compatibility.

There is also the unused l_ost_gen for each OST object in the LOV EA which could be used to distinguish the "ver" field of the FID if we wanted it to remain separate from the o_id on disk.

In summary for objects (note VER is flexible and could fit in a few places until we had an obdo_v2 and/or LOV_V4 that held a proper FID):

		SEQ				OID		VER

lu_fid: seq:64 oid:32 ver:32
IDIF: seq:31 1: ost_idx:16 o_id_hi:16 o_id_lo:32 0:
obdo (wire): o_gr:64 o_id:32 o_id:32_hi
LOVEA(disk): o_gr:64 o_id:32 o_id:32_hi

The IDIF would only be used if we need to represent an old objid as a FID (e.g. if we exported it for an OST changelog, or in a obdo_v2 or LOV_V4).

Cheers, Andreas
--
Andreas Dilger
Sr. Staff Engineer, Lustre Group
Sun Microsystems of Canada, Inc.