PATCH 1/1 ucc_geth: Fix half-duplex operation for non-MII/RMII interfaces

Currently the half-duplex operation seems to not work reliably for RGMII/GMII PHY interfaces. It takes about 10 minutes to boot NFS rootfs using 10/half link, following symptoms were observed:

ucc_geth: QE UCC Gigabit Ethernet Controller
ucc_geth: UCC1 at 0xe0082000 (irq = 32)
[...]
Sending DHCP and RARP requests .
PHY: mdio@e0082120:07 - Link is Up - 10/Half
., OK
[...]
Looking up port of RPC 100003/2 on 10.0.0.2 Looking up port of RPC 100005/1 on 10.0.0.2
VFS: Mounted root (nfs filesystem) readonly on device 0:13. Freeing unused kernel memory: 204k init
eth0: no IPv6 routers present
nfs: server 10.0.0.2 not responding, still trying
nfs: server 10.0.0.2 not responding, still trying
nfs: server 10.0.0.2 not responding, still trying
nfs: server 10.0.0.2 OK
nfs: server 10.0.0.2 OK
nfs: server 10.0.0.2 not responding, still trying [... few minutes of OK/not responding flood ...]

The statistic shows that there are indeed some errors:

  # ethtool -S eth0 | grep -v ": 0"
  NIC statistics:
       tx-64-frames: 42
       tx-65-127-frames: 9
       tx-128-255-frames: 4768
       rx-64-frames: 41
       rx-65-127-frames: 260
       rx-128-255-frames: 2679
       tx-bytes-ok: 859634
       tx-multicast-frames: 5
       tx-broadcast-frames: 7
       rx-frames: 8333
       rx-bytes-ok: 8039364
       rx-bytes-all: 8039364
       stats-counter-mask: 4294901760
       tx-single-collision: 324
       tx-multiple-collision: 47
       tx-late-collsion: 604
       tx-aborted-frames: 604
       tx-frames-ok: 4967
       tx-256-511-frames: 3
       tx-512-1023-frames: 79
       tx-1024-1518-frames: 71
       rx-256-511-frames: 37
       rx-512-1023-frames: 73
       rx-1024-1518-frames: 5243

According to current QEIWRM (Rev. 2 5/2009), FDX bit can be 0 for RGMII(10/100) modes, while MPC8568ERM (Rev. C 02/2007) spec says that cleared FDX bit is permitted for MII/RMII modes only.

The symptoms above were seen on MPC8569E-MDS boards, so QEIWRM is clearly wrong, and this patch completely cures the problems above.

---
 drivers/net/ucc_geth.c |    8 ++++++--
 1 files changed, 6 insertions(+), 2 deletions(-)
drivers/net/ucc_geth.c +6 -2
index 464df03..e618cf2 100644
@@ -1469,12 +1469,16 @@ static void adjust_link(struct net_device *dev)
 	if (phydev->link) {
 		u32 tempval = in_be32(&ug_regs->maccfg2);
 		u32 upsmr = in_be32(&uf_regs->upsmr);
+		phy_interface_t phyi = ugeth->phy_interface;
+
 		/* Now we make sure that we can be in full duplex mode.
 		 * If not, we operate in half-duplex mode. */
 		if (phydev->duplex != ugeth->oldduplex) {
 			new_state = 1;
-			if (!(phydev->duplex))
-				tempval &= ~(MACCFG2_FDX);
+			if (!phydev->duplex &&
+					(phyi == PHY_INTERFACE_MODE_MII ||
+					 phyi == PHY_INTERFACE_MODE_RMII))
+				tempval &= ~MACCFG2_FDX;
 			else
 				tempval |= MACCFG2_FDX;
 			ugeth->oldduplex = phydev->duplex;
Signature · 1 line
1.6.3.1
#1 lore raw
Quoted 10 lines · Anton Vorontsov

Currently the half-duplex operation seems to not work reliably for RGMII/GMII PHY interfaces. It takes about 10 minutes to boot NFS rootfs using 10/half link, following symptoms were observed:

ucc_geth: QE UCC Gigabit Ethernet Controller
ucc_geth: UCC1 at 0xe0082000 (irq = 32)
[...]
Sending DHCP and RARP requests .
PHY: mdio@e0082120:07 - Link is Up - 10/Half
., OK

So why does the phy think this is a half-duplex network?

Quoted 27 lines

[...]
Looking up port of RPC 100003/2 on 10.0.0.2 Looking up port of RPC 100005/1 on 10.0.0.2
VFS: Mounted root (nfs filesystem) readonly on device 0:13. Freeing unused kernel memory: 204k init
eth0: no IPv6 routers present
nfs: server 10.0.0.2 not responding, still trying
nfs: server 10.0.0.2 not responding, still trying
nfs: server 10.0.0.2 not responding, still trying
nfs: server 10.0.0.2 OK
nfs: server 10.0.0.2 OK
nfs: server 10.0.0.2 not responding, still trying [... few minutes of OK/not responding flood ...]

The statistic shows that there are indeed some errors:

  # ethtool -S eth0 | grep -v ": 0"
  NIC statistics:
       tx-64-frames: 42
       tx-65-127-frames: 9
       tx-128-255-frames: 4768
       rx-64-frames: 41
       rx-65-127-frames: 260
       rx-128-255-frames: 2679
       tx-bytes-ok: 859634
       tx-multicast-frames: 5
       tx-broadcast-frames: 7
Quoted 8 lines
       rx-frames: 8333
       rx-bytes-ok: 8039364
       rx-bytes-all: 8039364
       stats-counter-mask: 4294901760
       tx-single-collision: 324
       tx-multiple-collision: 47
       tx-late-collsion: 604
       tx-aborted-frames: 604

The above two counters are the actual errors from a half-duplex ethernet configuration. The size of the collision domain is limited so that the collisions from one end will reach the other end within the minimum frame length wire time. Thus the collision will be detected within the first 64 bytes of the frame. A late collision indicates a mis-configured network. The fact that everything seems to work when the MAC is placed into full-duplex mode hints that the network is really a full-duplex network.

Otherwise, if the network is really half-duplex, then presence of a full-duplex node will result in the other nodes seeing CRC/framing errors on receive, and possibly also late collisions, as the full-duplex node does not observe the CS or the CD( carrier sense and collision detect) part of CSMA/CD, because it doesn't care.

Putting a node in full-duplex will always make the nasty collision related errors go away, but it may not be a proper diagnosis of the problem.

Quoted 8 lines
       tx-frames-ok: 4967
       tx-256-511-frames: 3
       tx-512-1023-frames: 79
       tx-1024-1518-frames: 71
       rx-256-511-frames: 37
       rx-512-1023-frames: 73
       rx-1024-1518-frames: 5243
Quoted 6 lines

According to current QEIWRM (Rev. 2 5/2009), FDX bit can be 0 for RGMII(10/100) modes, while MPC8568ERM (Rev. C 02/2007) spec says that cleared FDX bit is permitted for MII/RMII modes only.

The symptoms above were seen on MPC8569E-MDS boards, so QEIWRM is clearly wrong, and this patch completely cures the problems above.

Not so fast - RGMII and GMII refer to the interface between the MAC and the PHY. While Gigabit physical links will always be full-duplex, phys that detect lower operational modes will indicate half-duplex where needed, and putting the MAC into full-duplex will make other nodes see errors.

As Andy indicated later, it may be necessary to alter the interface definition in those cases, depending on the particular hardware. Forcing full-duplex does not seem to be a general solution.

Mark Huth
MontaVista Software

Quoted 29 lines
---
 drivers/net/ucc_geth.c |    8 ++++++--
 1 files changed, 6 insertions(+), 2 deletions(-)
drivers/net/ucc_geth.c +6 -2
index 464df03..e618cf2 100644
@@ -1469,12 +1469,16 @@ static void adjust_link(struct net_device *dev)
 	if (phydev->link) {
 		u32 tempval = in_be32(&ug_regs->maccfg2);
 		u32 upsmr = in_be32(&uf_regs->upsmr);
+		phy_interface_t phyi = ugeth->phy_interface;
+
 		/* Now we make sure that we can be in full duplex mode.
 		 * If not, we operate in half-duplex mode. */
 		if (phydev->duplex != ugeth->oldduplex) {
 			new_state = 1;
-			if (!(phydev->duplex))
-				tempval &= ~(MACCFG2_FDX);
+			if (!phydev->duplex &&
+					(phyi == PHY_INTERFACE_MODE_MII ||
+					 phyi == PHY_INTERFACE_MODE_RMII))
+				tempval &= ~MACCFG2_FDX;
 			else
 				tempval |= MACCFG2_FDX;
 			ugeth->oldduplex = phydev->duplex;
#2 lore raw
Quoted 5 lines · Mark Huth
Quoted 4 lines · Anton Vorontsov

Currently the half-duplex operation seems to not work reliably for RGMII/GMII PHY interfaces. It takes about 10 minutes to boot NFS rootfs using 10/half link, following symptoms were observed:

Quoted 7 lines
Quoted 6 lines

ucc_geth: QE UCC Gigabit Ethernet Controller
ucc_geth: UCC1 at 0xe0082000 (irq = 32)
[...]
Sending DHCP and RARP requests .
PHY: mdio@e0082120:07 - Link is Up - 10/Half
., OK

So why does the phy think this is a half-duplex network?

Because it's physical media now in half-duplex. At least that's what PHY detects.

[...]

Quoted 10 lines
Quoted 2 lines
       tx-late-collsion: 604
       tx-aborted-frames: 604

The above two counters are the actual errors from a half-duplex ethernet configuration. The size of the collision domain is limited so that the collisions from one end will reach the other end within the minimum frame length wire time. Thus the collision will be detected within the first 64 bytes of the frame. A late collision indicates a mis-configured network. The fact that everything seems to work when the MAC is placed into full-duplex mode hints that the network is really a full-duplex network.

No, it's half. Can be configured so on both sides, with or without auto-negotiation. The "10/half" message comes from a PHY layer, the PHY layer reports human readable values of PHY's LPA/BMSR registers, not MAC's configuration.

Of course, it could be that the root cause of the problems I observe is weird NIC on my host. Well, then QA team should have used the same broken NIC on their hosts. :-)

I can easily test it by interconnecting two targets though.

Quoted 22 lines

Otherwise, if the network is really half-duplex, then presence of a full-duplex node will result in the other nodes seeing CRC/framing errors on receive, and possibly also late collisions, as the full-duplex node does not observe the CS or the CD( carrier sense and collision detect) part of CSMA/CD, because it doesn't care.

Putting a node in full-duplex will always make the nasty collision related errors go away, but it may not be a proper diagnosis of the problem.

Quoted 12 lines
       tx-frames-ok: 4967
       tx-256-511-frames: 3
       tx-512-1023-frames: 79
       tx-1024-1518-frames: 71
       rx-256-511-frames: 37
       rx-512-1023-frames: 73
       rx-1024-1518-frames: 5243

According to current QEIWRM (Rev. 2 5/2009), FDX bit can be 0 for RGMII(10/100) modes, while MPC8568ERM (Rev. C 02/2007) spec says that cleared FDX bit is permitted for MII/RMII modes only.

Quoted 5 lines
Quoted 2 lines

The symptoms above were seen on MPC8569E-MDS boards, so QEIWRM is clearly wrong, and this patch completely cures the problems above.

Not so fast - RGMII and GMII refer to the interface between the MAC and the PHY.

Correct.

Quoted 4 lines

While Gigabit physical links will always be full-duplex, phys that detect lower operational modes will indicate half-duplex where needed, and putting the MAC into full-duplex will make other nodes see errors.

D'oh!

[1358634.636147] eth1: Transmit error, Tx status register 82.
[1358634.636150] Probably a duplex mismatch.  See Documentation/networking/vortex.txt

It's on a host side.

Quoted 3 lines

As Andy indicated later, it may be necessary to alter the interface definition in those cases, depending on the particular hardware. Forcing full-duplex does not seem to be a general solution.

Definitely. Though I'm out of ideas if it's NOT host-side issue.

Thanks!

Signature · 3 lines
Anton Vorontsov
email: [email protected]
irc://irc.freenode.net/bd2
#3 lore raw

On Thu, Jun 25, 2009 at 11:02:36AM +0400, Anton Vorontsov wrote:
[...]

Quoted 5 lines

Of course, it could be that the root cause of the problems I observe is weird NIC on my host. Well, then QA team should have used the same broken NIC on their hosts. :-)

I can easily test it by interconnecting two targets though.

[...]

Quoted 1 line

Definitely. Though I'm out of ideas if it's NOT host-side issue.

Two boards interconnected work fine. eTSEC + SKY2 NIC also work OK. I'll test some more NICs, known to not work is 3Com Corporation 3c905C-TX/TX-M [Tornado] (rev 74).

After some netperf tests, statistic on a gianfar board:

# ethtool -S eth0 | grep -v ": 0"
NIC statistics:
     rx-dropped-by-kernel: 2
     tx-rx-64-frames: 52
     tx-rx-65-127-frames: 20668
     tx-rx-128-255-frames: 10343
     tx-rx-256-511-frames: 113
     tx-rx-512-1023-frames: 147
     tx-rx-1024-1518-frames: 45965
     rx-bytes: 45075782
     rx-packets: 50300
     rx-carrier-sense-error: 1
     rx-fragmented-frames: 7600
     tx-byte-counter: 27401677
     tx-packets: 34618
     tx-broadcast-packets: 3
     tx-deferral-packets: 5
     tx-single-collision-packets: 4039
     tx-multiple-collision-packets: 1943
     tx-excessive-collision-packets: 30
     tx-total-collision: 785

Thanks for the ideas, Mark.

Signature · 3 lines
Anton Vorontsov
email: [email protected]