mpt2sas: Excessive log info causes sas iounit page time out
PATCH 5/9 mpt2sas: Excessive log info causes sas iounit page time out
Inhibit 0x3117 loginfos - during cable pull, there are too many printks going to the syslog, this is have impact on how fast the interrupt routine can handle keeping up with command completions; this was the root cause to the config pages timeouts.
---
Signed-off-by Kashyap Desai <[email protected]>
Signed-off-by Eric Moore <[email protected]>
---
drivers/scsi/mpt2sas/mpt2sas_base.c +4 -0
@@ -440,6 +440,10 @@ _base_sas_log_info(struct MPT2SAS_ADAPTER *ioc , u32 log_info)if (sas_loginfo.dw.bus_type !=3 /*SAS*/ )return ; +/* each nexus loss loginfo */ +if (log_info ==0x31170000 ) +return ; +/* eat the loginfos associated with task aborts */ if (ioc->ignore_loginfos && (log_info ==30050000 || log_info ==0x31140000 || log_info ==0x31130000 ))
drivers/scsi/mpt2sas/mpt2sas_scsih.c +4 -0
@@ -2767,6 +2767,10 @@ _scsih_scsi_ioc_info(struct MPT2SAS_ADAPTER *ioc, struct scsi_cmnd *scmd,char *desc_ioc_state =NULL ;char *desc_scsi_status =NULL ;char *desc_scsi_state = ioc->tmp_string; +u32 log_info =le32_to_cpu (mpi_reply->IOCLogInfo); + +if (log_info ==0x31170000 ) +return ;switch (ioc_status) {case MPI2_IOCSTATUS_SUCCESS :