[I'm not subscribed; please cc]

I'm being affected by the HID blacklist on USB_DEVICE_ID_TENX_IBUDDY1 as described in 13411. My barcode scanner is a USB HID device, and works completely once I remove that blacklist entry.

Please let me know if there is anything I can do to help get this bug fixed.

Below is lsusb -v on the device (with the blacklist entry removed, if that matters):

Bus 001 Device 071: ID 1130:0001 Tenx Technology, Inc. Device Descriptor:
bLength 18
bDescriptorType 1
bcdUSB 1.10

  bDeviceClass            0 (Defined at Interface level)
  bDeviceSubClass         0 
  bDeviceProtocol         0 
  bMaxPacketSize0         8
  idVendor           0x1130 Tenx Technology, Inc.
  idProduct          0x0001 
  bcdDevice            1.00
  iManufacturer           0 
  iProduct                2 USB-TMU-V3
  iSerial                 0 
  bNumConfigurations      1

Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 34
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 0
bmAttributes 0xa0
(Bus Powered)
Remote Wakeup
MaxPower 100mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 1
bInterfaceClass 3 Human Interface Device
bInterfaceSubClass 1 Boot Interface Subclass
bInterfaceProtocol 1 Keyboard
iInterface 0
HID Device Descriptor:
bLength 9
bDescriptorType 33
bcdHID 1.10
bCountryCode 0 Not supported
bNumDescriptors 1
bDescriptorType 34 Report
wDescriptorLength 78
Report Descriptors:
** UNAVAILABLE **
Endpoint Descriptor:
bLength 7
bDescriptorType 5
bEndpointAddress 0x81 EP 1 IN
bmAttributes 3
Transfer Type Interrupt
Synch Type None
Usage Type Data
wMaxPacketSize 0x0008 1x 8 bytes
bInterval 10
Device Status: 0x0002
(Bus Powered)
Remote Wakeup Enabled

Signature · 3 lines
BOFH excuse #211:

Lightning strikes.