s390: fix build on 32 bit host

PATCH In review Michael S. Tsirkin 2 participants 2 messages Dec 13, 2009

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 s390: fix build on 32 bit host

Building on 32 bit host we get:
hw/s390-virtio.c: In function ‘s390_init’:
hw/s390-virtio.c:184: error: integer constant is too large for ‘unsigned long’ type 64 bit values must be ULL.

---
 hw/s390-virtio.c |    2 +-
 1 files changed, 1 insertions(+), 1 deletions(-)
hw/s390-virtio.c +1 -1
index 51c032a..e71dbe6 100644
@@ -181,7 +181,7 @@ static void s390_init(ram_addr_t ram_size,
 
         cpu_synchronize_state(env);
         env->psw.addr = KERN_IMAGE_START;
-        env->psw.mask = 0x0000000180000000UL;
+        env->psw.mask = 0x0000000180000000ULL;
     }
 
     if (initrd_filename) {
Signature · 1 line