AR7: use correct UART port type
PATCH 1/2 AR7: use correct UART port type
PORT_AR7 has the correct TRIG flag (UART_FCR_R_TRIG_00) as well as UART_CAP_AFE being set. This fixes UART on TNETD7300 revision 0x02, which would otherwise mangle some characters, no side effects on other revisions.
Signed-off-by Florian Fainelli <[email protected]>
--- arch/mips/ar7/platform.c | 2 +- 1 files changed, 1 insertions(+), 1 deletions(-)
arch/mips/ar7/platform.c +1 -1
@@ -542,7 +542,7 @@ static int __init ar7_register_uarts(void)if (IS_ERR (bus_clk))panic ("unable to get bus clk\n" ); - uart_port.type =PORT_16550A ; + uart_port.type =PORT_AR7 ; uart_port.uartclk =clk_get_rate (bus_clk) /2 ; uart_port.iotype =UPIO_MEM32 ; uart_port.regshift =2 ;
Signature · 1 line
1.7.1
Ralf Baechle
AppliedOn Sun, May 16, 2010 at 03:25:17PM +0200, Florian Fainelli wrote:
Thanks, applied.
Ralf