Skip to contentSkip to conversation

hwmon: (it87) Fix manual fan speed control on

PATCH Superseded Jean Delvare 2 participants 3 messages Nov 29, 2010

Subsystems (2)

v1 of 2 Superseded Latest is v2 →

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 hwmon: (it87) Fix manual fan speed control on

The manual fan speed control logic of the IT8721F is much different from what older devices had. Update the code to properly support that.

---
 drivers/hwmon/it87.c |   61 ++++++++++++++++++++++++++++++++++++--------------
 1 file changed, 45 insertions(+), 16 deletions(-)
drivers/hwmon/it87.c +45 -16
@@ -187,6 +187,7 @@ static const u8 IT87_REG_FANX_MIN[]	= {
 #define IT87_REG_FAN_MAIN_CTRL 0x13
 #define IT87_REG_FAN_CTL       0x14
 #define IT87_REG_PWM(nr)       (0x15 + (nr))
+#define IT87_REG_PWM_DUTY(nr)  (0x63 + (nr) * 8)
 
 #define IT87_REG_VIN(nr)       (0x20 + (nr))
 #define IT87_REG_TEMP(nr)      (0x29 + (nr))
@@ -251,12 +252,16 @@ struct it87_data {
 	u8 fan_main_ctrl;	/* Register value */
 	u8 fan_ctl;		/* Register value */
 
-	/* The following 3 arrays correspond to the same registers. The
-	 * meaning of bits 6-0 depends on the value of bit 7, and we want
-	 * to preserve settings on mode changes, so we have to track all
-	 * values separately. */
+	/* The following 3 arrays correspond to the same registers up to
+	 * the IT8720F. The meaning of bits 6-0 depends on the value of bit
+	 * 7, and we want to preserve settings on mode changes, so we have
+	 * to track all values separately.
+	 * Starting with the IT8721F, the manual PWM duty cycles are stored
+	 * in separate registers (8-bit values), so the separate tracking
+	 * is no longer needed, but it is still done to keep the driver
+	 * simple. */
 	u8 pwm_ctrl[3];		/* Register value */
-	u8 pwm_duty[3];		/* Manual PWM value set by user (bit 6-0) */
+	u8 pwm_duty[3];		/* Manual PWM value set by user */
 	u8 pwm_temp_map[3];	/* PWM to temp. chan. mapping (bits 1-0) */
 
 	/* Automatic fan speed control registers */
@@ -832,7 +837,9 @@ static ssize_t set_pwm_enable(struct dev
 				 data->fan_main_ctrl);
 	} else {
 		if (val = 1)				/* Manual mode */
-			data->pwm_ctrl[nr] = data->pwm_duty[nr];
+			data->pwm_ctrl[nr] = data->type = it8721 ?
+					     data->pwm_temp_map[nr] :
+					     data->pwm_duty[nr];
 		else					/* Automatic mode */
 			data->pwm_ctrl[nr] = 0x80 | data->pwm_temp_map[nr];
 		it87_write_value(data, IT87_REG_PWM(nr), data->pwm_ctrl[nr]);
@@ -858,12 +865,25 @@ static ssize_t set_pwm(struct device *de
 		return -EINVAL;
 
 	mutex_lock(&data->update_lock);
-	data->pwm_duty[nr] = pwm_to_reg(data, val);
-	/* If we are in manual mode, write the duty cycle immediately;
-	 * otherwise, just store it for later use. */
-	if (!(data->pwm_ctrl[nr] & 0x80)) {
-		data->pwm_ctrl[nr] = data->pwm_duty[nr];
-		it87_write_value(data, IT87_REG_PWM(nr), data->pwm_ctrl[nr]);
+	if (data->type = it8721) {
+		/* If we are in automatic mode, the PWM duty cycle register
+		 * is read-only so we can't write the value */
+		if (data->pwm_ctrl[nr] & 0x80) {
+			mutex_unlock(&data->update_lock);
+			return -EBUSY;
+		}
+		data->pwm_duty[nr] = pwm_to_reg(data, val);
+		it87_write_value(data, IT87_REG_PWM_DUTY(nr),
+				 data->pwm_duty[nr]);
+	} else {
+		data->pwm_duty[nr] = pwm_to_reg(data, val);
+		/* If we are in manual mode, write the duty cycle immediately;
+		 * otherwise, just store it for later use. */
+		if (!(data->pwm_ctrl[nr] & 0x80)) {
+			data->pwm_ctrl[nr] = data->pwm_duty[nr];
+			it87_write_value(data, IT87_REG_PWM(nr),
+					 data->pwm_ctrl[nr]);
+		}
 	}
 	mutex_unlock(&data->update_lock);
 	return count;
@@ -1958,7 +1978,10 @@ static void __devinit it87_init_device(s
 	 *   channels to use when later setting to automatic mode later.
 	 *   Use a 1:1 mapping by default (we are clueless.)
 	 * In both cases, the value can (and should) be changed by the user
-	 * prior to switching to a different mode. */
+	 * prior to switching to a different mode.
+	 * Note that this is no longer needed for the IT8721F and later, as
+	 * these have separate registers for the temperature mapping and the
+	 * manual duty cycle. */
 	for (i = 0; i < 3; i++) {
 		data->pwm_temp_map[i] = i;
 		data->pwm_duty[i] = 0x7f;	/* Full speed */
@@ -2034,10 +2057,16 @@ static void __devinit it87_init_device(s
 static void it87_update_pwm_ctrl(struct it87_data *data, int nr)
 {
 	data->pwm_ctrl[nr] = it87_read_value(data, IT87_REG_PWM(nr));
-	if (data->pwm_ctrl[nr] & 0x80)	/* Automatic mode */
+	if (data->type = it8721) {
 		data->pwm_temp_map[nr] = data->pwm_ctrl[nr] & 0x03;
-	else				/* Manual mode */
-		data->pwm_duty[nr] = data->pwm_ctrl[nr] & 0x7f;
+		data->pwm_duty[nr] = it87_read_value(data,
+						     IT87_REG_PWM_DUTY(nr));
+	} else {
+		if (data->pwm_ctrl[nr] & 0x80)	/* Automatic mode */
+			data->pwm_temp_map[nr] = data->pwm_ctrl[nr] & 0x03;
+		else				/* Manual mode */
+			data->pwm_duty[nr] = (data->pwm_ctrl[nr] & 0x7f) << 1;
+	}
 
 	if (has_old_autopwm(data)) {
 		int i;
Signature · 6 lines
Jean Delvare

_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors
Acked-by on v1 1/1
#1 lore raw

Re: [lm-sensors] [PATCH] hwmon: (it87) Fix manual fan speed control

Hi Jean,

Quoted 4 lines · Jean Delvare

The manual fan speed control logic of the IT8721F is much different from what older devices had. Update the code to properly support that.

Minor comment below, otherwise

Quoted 97 lines
---
 drivers/hwmon/it87.c |   61 ++++++++++++++++++++++++++++++++++++--------------
 1 file changed, 45 insertions(+), 16 deletions(-)
drivers/hwmon/it87.c +37 -14
@@ -187,6 +187,7 @@ static const u8 IT87_REG_FANX_MIN[]	= {
 #define IT87_REG_FAN_MAIN_CTRL 0x13
 #define IT87_REG_FAN_CTL       0x14
 #define IT87_REG_PWM(nr)       (0x15 + (nr))
+#define IT87_REG_PWM_DUTY(nr)  (0x63 + (nr) * 8)
 
 #define IT87_REG_VIN(nr)       (0x20 + (nr))
 #define IT87_REG_TEMP(nr)      (0x29 + (nr))
@@ -251,12 +252,16 @@ struct it87_data {
 	u8 fan_main_ctrl;	/* Register value */
 	u8 fan_ctl;		/* Register value */
 
-	/* The following 3 arrays correspond to the same registers. The
-	 * meaning of bits 6-0 depends on the value of bit 7, and we want
-	 * to preserve settings on mode changes, so we have to track all
-	 * values separately. */
+	/* The following 3 arrays correspond to the same registers up to
+	 * the IT8720F. The meaning of bits 6-0 depends on the value of bit
+	 * 7, and we want to preserve settings on mode changes, so we have
+	 * to track all values separately.
+	 * Starting with the IT8721F, the manual PWM duty cycles are stored
+	 * in separate registers (8-bit values), so the separate tracking
+	 * is no longer needed, but it is still done to keep the driver
+	 * simple. */
 	u8 pwm_ctrl[3];		/* Register value */
-	u8 pwm_duty[3];		/* Manual PWM value set by user (bit 6-0) */
+	u8 pwm_duty[3];		/* Manual PWM value set by user */
 	u8 pwm_temp_map[3];	/* PWM to temp. chan. mapping (bits 1-0) */
 
 	/* Automatic fan speed control registers */
@@ -832,7 +837,9 @@ static ssize_t set_pwm_enable(struct dev
 				 data->fan_main_ctrl);
 	} else {
 		if (val = 1)				/* Manual mode */
-			data->pwm_ctrl[nr] = data->pwm_duty[nr];
+			data->pwm_ctrl[nr] = data->type = it8721 ?
+					     data->pwm_temp_map[nr] :
+					     data->pwm_duty[nr];
 		else					/* Automatic mode */
 			data->pwm_ctrl[nr] = 0x80 | data->pwm_temp_map[nr];
 		it87_write_value(data, IT87_REG_PWM(nr), data->pwm_ctrl[nr]);
@@ -858,12 +865,25 @@ static ssize_t set_pwm(struct device *de
 		return -EINVAL;
 
 	mutex_lock(&data->update_lock);
-	data->pwm_duty[nr] = pwm_to_reg(data, val);
-	/* If we are in manual mode, write the duty cycle immediately;
-	 * otherwise, just store it for later use. */
-	if (!(data->pwm_ctrl[nr] & 0x80)) {
-		data->pwm_ctrl[nr] = data->pwm_duty[nr];
-		it87_write_value(data, IT87_REG_PWM(nr), data->pwm_ctrl[nr]);
+	if (data->type = it8721) {
+		/* If we are in automatic mode, the PWM duty cycle register
+		 * is read-only so we can't write the value */
+		if (data->pwm_ctrl[nr] & 0x80) {
+			mutex_unlock(&data->update_lock);
+			return -EBUSY;
+		}
+		data->pwm_duty[nr] = pwm_to_reg(data, val);
+		it87_write_value(data, IT87_REG_PWM_DUTY(nr),
+				 data->pwm_duty[nr]);
+	} else {
+		data->pwm_duty[nr] = pwm_to_reg(data, val);
+		/* If we are in manual mode, write the duty cycle immediately;
+		 * otherwise, just store it for later use. */
+		if (!(data->pwm_ctrl[nr] & 0x80)) {
+			data->pwm_ctrl[nr] = data->pwm_duty[nr];
+			it87_write_value(data, IT87_REG_PWM(nr),
+					 data->pwm_ctrl[nr]);
+		}
 	}
 	mutex_unlock(&data->update_lock);
 	return count;
@@ -1958,7 +1978,10 @@ static void __devinit it87_init_device(s
 	 *   channels to use when later setting to automatic mode later.
 	 *   Use a 1:1 mapping by default (we are clueless.)
 	 * In both cases, the value can (and should) be changed by the user
-	 * prior to switching to a different mode. */
+	 * prior to switching to a different mode.
+	 * Note that this is no longer needed for the IT8721F and later, as
+	 * these have separate registers for the temperature mapping and the
+	 * manual duty cycle. */
 	for (i = 0; i < 3; i++) {
 		data->pwm_temp_map[i] = i;
 		data->pwm_duty[i] = 0x7f;	/* Full speed */
@@ -2034,10 +2057,16 @@ static void __devinit it87_init_device(s
 static void it87_update_pwm_ctrl(struct it87_data *data, int nr)
 {
 	data->pwm_ctrl[nr] = it87_read_value(data, IT87_REG_PWM(nr));
-	if (data->pwm_ctrl[nr] & 0x80)	/* Automatic mode */
+	if (data->type = it8721) {

drivers/hwmon/it87.c static void __devinit it87_init_device(s · line 2068

Quoted 10 lines
drivers/hwmon/it87.c +7 -2
 		data->pwm_temp_map[nr] = data->pwm_ctrl[nr] & 0x03;
-	else				/* Manual mode */
-		data->pwm_duty[nr] = data->pwm_ctrl[nr] & 0x7f;
+		data->pwm_duty[nr] = it87_read_value(data,
+						     IT87_REG_PWM_DUTY(nr));
+	} else {
+		if (data->pwm_ctrl[nr] & 0x80)	/* Automatic mode */
+			data->pwm_temp_map[nr] = data->pwm_ctrl[nr] & 0x03;
+		else				/* Manual mode */
+			data->pwm_duty[nr] = (data->pwm_ctrl[nr] & 0x7f) << 1;

This is a bug fix, isn't it ? You might want to mention it in the commit log.

_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors

#2 lore raw

Re: [lm-sensors] [PATCH] hwmon: (it87) Fix manual fan speed control

In reply to Jean Delvare

Hi Guenter,

Quoted 29 lines · Guenter Roeck

Hi Jean,

Quoted 4 lines · Jean Delvare

The manual fan speed control logic of the IT8721F is much different from what older devices had. Update the code to properly support that.

Minor comment below, otherwise

Quoted 17 lines
---
 drivers/hwmon/it87.c |   61 ++++++++++++++++++++++++++++++++++++--------------
 1 file changed, 45 insertions(+), 16 deletions(-)
drivers/hwmon/it87.c +2 -3
(...)
@@ -2034,10 +2057,16 @@ static void __devinit it87_init_device(s
 static void it87_update_pwm_ctrl(struct it87_data *data, int nr)
 {
 	data->pwm_ctrl[nr] = it87_read_value(data, IT87_REG_PWM(nr));
-	if (data->pwm_ctrl[nr] & 0x80)	/* Automatic mode */
+	if (data->type = it8721) {
 		data->pwm_temp_map[nr] = data->pwm_ctrl[nr] & 0x03;
-	else				/* Manual mode */
-		data->pwm_duty[nr] = data->pwm_ctrl[nr] & 0x7f;
+		data->pwm_duty[nr] = it87_read_value(data,
Quoted 8 lines

drivers/hwmon/it87.c static void __devinit it87_init_device(s · line 2068

Quoted 6 lines
drivers/hwmon/it87.c +6 -0
+						     IT87_REG_PWM_DUTY(nr));
+	} else {
+		if (data->pwm_ctrl[nr] & 0x80)	/* Automatic mode */
+			data->pwm_temp_map[nr] = data->pwm_ctrl[nr] & 0x03;
+		else				/* Manual mode */
+			data->pwm_duty[nr] = (data->pwm_ctrl[nr] & 0x7f) << 1;

This is a bug fix, isn't it ? You might want to mention it in the commit log.

Huh. No, it isn't. It's me adding a bug actually... Glad you spotted it, thanks for the careful review. I seem to recall that at some point when writing this patch, I considered left-aligning the PWM duty cycle value in the hope to simplify the code, but apparently I changed my mind half way through.

I'll send a fixed patch...

Signature · 6 lines
Jean Delvare

_______________________________________________
lm-sensors mailing list
[email protected]