s3c_adc_battery: Fix method names when PM not set

PATCH Applied Heiko Stübner 3 participants 3 messages Mar 14, 2011 – Mar 16, 2011

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 s3c_adc_battery: Fix method names when PM not set

From: Heiko Stuebner <[email protected]>

s3c_adc_battery declares wrong method names when CONFIG_PM is not set.

---
 drivers/power/s3c_adc_battery.c |    4 ++--
 1 files changed, 2 insertions(+), 2 deletions(-)
drivers/power/s3c_adc_battery.c +2 -2
index 4255f23..d36c289 100644
@@ -406,8 +406,8 @@ static int s3c_adc_bat_resume(struct platform_device *pdev)
 	return 0;
 }
 #else
-#define s3c_adc_battery_suspend NULL
-#define s3c_adc_battery_resume NULL
+#define s3c_adc_bat_suspend NULL
+#define s3c_adc_bat_resume NULL
 #endif
 
 static struct platform_driver s3c_adc_bat_driver = {
Signature · 1 line
tg: (2fbfac4..) topic/fixes/s3c_adc_battery_nopm (depends on: master)
Acked-by on v1 1/1
#1 lore raw
Quoted 5 lines · On Monday 14 March 2011 22:12:39 Heiko Stübner wrote:

From: Heiko Stuebner <[email protected]>

s3c_adc_battery declares wrong method names when CONFIG_PM is not set.

Quoted 19 lines
---
 drivers/power/s3c_adc_battery.c |    4 ++--
 1 files changed, 2 insertions(+), 2 deletions(-)
(quoted diff) +0 -0

b/drivers/power/s3c_adc_battery.c index 4255f23..d36c289 100644

drivers/power/s3c_adc_battery.c +2 -2
@@ -406,8 +406,8 @@ static int s3c_adc_bat_resume(struct platform_device
 *pdev) return 0;
 }
 #else
-#define s3c_adc_battery_suspend NULL
-#define s3c_adc_battery_resume NULL
+#define s3c_adc_bat_suspend NULL
+#define s3c_adc_bat_resume NULL
 #endif
 
 static struct platform_driver s3c_adc_bat_driver = {