staging: comedi: pcl816: if test should use logical OR not bitwise OR
PATCH 1/1 staging: comedi: pcl816: if test should use logical OR not bitwise OR
This quiets a couple sparse warnings about:
warning: dubious: !x | !y
warning: dubious: x | !y
Also, remove the unnecessary parentheses abound the variables.
Signed-off-by H Hartley Sweeten <[email protected]>
Cc Ian Abbott <[email protected]>
Cc Mori Hess <[email protected]>
Cc Greg Kroah-Hartman <[email protected]>
---
drivers/staging/comedi/drivers/pcl816.c +2 -2
@@ -414,8 +414,8 @@ static irqreturn_t interrupt_pcl816(int irq, void *d) }outb (0 , dev->iobase +PCL816_CLRINT );/* clear INT request */ -if ((!dev->irq) | (!devpriv->irq_free) | (!devpriv->irq_blocked) | - (!devpriv->int816_mode)) { +if (!dev->irq || !devpriv->irq_free || !devpriv->irq_blocked || + !devpriv->int816_mode) {if (devpriv->irq_was_now_closed) { devpriv->irq_was_now_closed =0 ;/* comedi_error(dev,"last IRQ.."); */