PATCH 1/1 be2net: Missing byteswap in be_get_fw_log_level causes oops on PowerPC

We are seeing an oops in be_get_fw_log_level on ppc64 where we walk off the end of memory.

commit 941a77d582c8 (be2net: Fix to allow get/set of debug levels in the firmware.) requires byteswapping of num_modes and num_modules.

---

drivers/net/ethernet/emulex/benet/be_ethtool.c +3 -2
index 63e51d4..59ee51a 100644
@@ -910,8 +910,9 @@ static void be_set_fw_log_level(struct be_adapter *adapter, u32 level)
 	if (!status) {
 		cfgs = (struct be_fat_conf_params *)(extfat_cmd.va +
 					sizeof(struct be_cmd_resp_hdr));
-		for (i = 0; i < cfgs->num_modules; i++) {
-			for (j = 0; j < cfgs->module[i].num_modes; j++) {
+		for (i = 0; i < le32_to_cpu(cfgs->num_modules); i++) {
+			u32 num_modes = le32_to_cpu(cfgs->module[i].num_modes);
+			for (j = 0; j < num_modes; j++) {
 				if (cfgs->module[i].trace_lvl[j].mode ==
 								MODE_UART)
 					cfgs->module[i].trace_lvl[j].dbg_lvl =
drivers/net/ethernet/emulex/benet/be_main.c +1 -1
index 501dfa9..bd5cf7e 100644
@@ -3479,7 +3479,7 @@ u32 be_get_fw_log_level(struct be_adapter *adapter)
 	if (!status) {
 		cfgs = (struct be_fat_conf_params *)(extfat_cmd.va +
 						sizeof(struct be_cmd_resp_hdr));
-		for (j = 0; j < cfgs->module[0].num_modes; j++) {
+		for (j = 0; j < le32_to_cpu(cfgs->module[0].num_modes); j++) {
 			if (cfgs->module[0].trace_lvl[j].mode == MODE_UART)
 				level = cfgs->module[0].trace_lvl[j].dbg_lvl;
 		}
Acked-by Sathya Perla on v1 1/1
#1 lore raw
Quoted 11 lines

-----Original Message-----
From: Anton Blanchard [mailto:[email protected]]

We are seeing an oops in be_get_fw_log_level on ppc64 where we walk off the end of memory.

commit 941a77d582c8 (be2net: Fix to allow get/set of debug levels in the firmware.) requires byteswapping of num_modes and num_modules.

Thanks for the fix!

Quoted 35 lines

---

drivers/net/ethernet/emulex/benet/be_ethtool.c +3 -2
index 63e51d4..59ee51a 100644
@@ -910,8 +910,9 @@ static void be_set_fw_log_level(struct be_adapter *adapter,
 u32 level)
 	if (!status) {
 		cfgs = (struct be_fat_conf_params *)(extfat_cmd.va +
 					sizeof(struct be_cmd_resp_hdr));
-		for (i = 0; i < cfgs->num_modules; i++) {
-			for (j = 0; j < cfgs->module[i].num_modes; j++) {
+		for (i = 0; i < le32_to_cpu(cfgs->num_modules); i++) {
+			u32 num_modes = le32_to_cpu(cfgs-
 >module[i].num_modes);
+			for (j = 0; j < num_modes; j++) {
 				if (cfgs->module[i].trace_lvl[j].mode ==
								MODE_UART)
					cfgs->module[i].trace_lvl[j].dbg_lvl =
drivers/net/ethernet/emulex/benet/be_main.c +1 -1
index 501dfa9..bd5cf7e 100644
@@ -3479,7 +3479,7 @@ u32 be_get_fw_log_level(struct be_adapter *adapter)
 	if (!status) {
 		cfgs = (struct be_fat_conf_params *)(extfat_cmd.va +
 						sizeof(struct be_cmd_resp_hdr));
-		for (j = 0; j < cfgs->module[0].num_modes; j++) {
+		for (j = 0; j < le32_to_cpu(cfgs->module[0].num_modes); j++) {
 			if (cfgs->module[0].trace_lvl[j].mode == MODE_UART)