master - vgextend: Allow PVs to be added to VGs that have PVs missing
Gitweb: http://git.fedorahosted.org/git/?p=lvm2.git;a=commitdiff;h=186a2772e8ac3c2088bdfc833c32d773464d666b Commit: 186a2772e8ac3c2088bdfc833c32d773464d666b Parent: 45db25817ff342a86b2ddf000b4b3a4d59be8848 Author: Jonathan Brassow <[email protected]> AuthorDate: Thu Jul 26 17:06:06 2012 -0500 Committer: Jonathan Brassow <[email protected]> CommitterDate: Thu Jul 26 17:06:06 2012 -0500
vgextend: Allow PVs to be added to VGs that have PVs missing
Allowing people to add devices to a VG that has PVs missing helps people avoid the inability to repair RAID LVs in certain cases. For example, if a user creates a RAID 4/5/6 LV using all of the available devices in a VG, there will be no spare devices to repair the LV with if a device should fail. Further, because the VG is missing a device, new devices cannot be added to allow the repair. If 'vgreduce --removemissing' were attempted, the "MISSING" PV could not be removed without also destroying the RAID LV.
Allowing vgextend to operate solves the circular dependency.
When the PV is added by a vgextend operation, the sequence number is incremented and the 'MISSING' flag is put on the PVs which are missing.
--- WHATS_NEW | 1 + tools/vgextend.c | 9 +++++++-- 2 files changed, 8 insertions(+), 2 deletions(-)
WHATS_NEW +1 -0
@@ -1,5 +1,6 @@ Version 2.02.97 - =============================== + Allow vgextend to add PVs to a VG that is missing PVs. Recognise Micron PCIe SSDs in filter and move array out to device-types.h. Fix segfault when attempting to replace RAID 4/5/6 device (2.02.97). Fix dumpconfig <node> to print only <node> without its siblings (2.02.89).
tools/vgextend.c +7 -2
@@ -66,8 +66,13 @@ int vgextend(struct cmd_context *cmd, int argc, char **argv)return EINVALID_CMD_LINE ; } -if (arg_count (cmd, restoremissing_ARG)) - cmd->handles_missing_pvs =1 ; +/* +* It is always ok to add new PVs to a VG - even if there are +* missing PVs. No LVs are affected by this operation, but +* repair processes - particularly for RAID segtypes - can +* be facilitated. +*/ + cmd->handles_missing_pvs =1 ;log_verbose ("Checking for volume group \"%s\"" , vg_name); vg =vg_read_for_update (cmd, vg_name,NULL ,0 );