Skip to contentSkip to conversation

recommended way to add ssd cache to mdraid array

DISCUSSION Thomas Fjellstrom 8 participants 53 messages Dec 22, 2012 – Feb 10, 2013 MD RAID

lore
Share & tools
lore
#0 lore raw

I'm setting up a new nas box (7x2TB on a IBM M1015 8 port sas card flashed to 9211IT mode) and was thinking about adding an SSD cache to it. I've been following bcache's development, but it seems to have stalled a bit.

I've got a 240G Samsung 470/810 that I'd like to use for this.

Also I was wondering if anyone has any tips on the best (or their preferred) way to set up a "big" raid6 array with a single filesystem. I'm probably going to stick with XFS, but I'm not married to it, if there's something better for a big media (audio, video, disk images, backups, etc) volume I'd love to hear about it.

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#1 lore raw
Quoted 11 lines · Thomas Fjellstrom

I'm setting up a new nas box (7x2TB on a IBM M1015 8 port sas card flashed to 9211IT mode) and was thinking about adding an SSD cache to it. I've been following bcache's development, but it seems to have stalled a bit.

I've got a 240G Samsung 470/810 that I'd like to use for this.

Also I was wondering if anyone has any tips on the best (or their preferred) way to set up a "big" raid6 array with a single filesystem. I'm probably going to stick with XFS, but I'm not married to it, if there's something better for a big media (audio, video, disk images, backups, etc) volume I'd love to hear about it.

So my array has finally finished resyncing, and I've run a simple iozone test on it formated with xfs, and I'm seeing some somewhat low write results:

moose@mrbig:/mnt/mrbig/data/test$ iozone -a -s 32G -r 8M
                                                            random  random    
bkwd   record   stride                                   
              KB  reclen   write rewrite    read    reread    read   write    
read  rewrite     read   fwrite frewrite   fread  freread
        33554432    8192  212507  210382   630327   630852  372807  161710  
388319  4922757   617347   210642   217122  717279   716150

Is this normal for a 7 disk (2TB seagate barracudas) raid array on a pcie x8 sas controller?

I was thinking it might be alignment issues, but there are no partitions on the disks, and xfs seems to have correctly set up the sunit and swidth settings (128/640 for a 7 disk raid6). While 200MB/s is probably more than I need day to day, I'd like to make sure it is set up properly.

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#2 lore raw
Quoted 26 lines · you
Quoted 5 lines · Thomas Fjellstrom

I'm setting up a new nas box (7x2TB on a IBM M1015 8 port sas card flashed to 9211IT mode) and was thinking about adding an SSD cache to it. I've been following bcache's development, but it seems to have stalled a bit.

Quoted 7 lines

I've got a 240G Samsung 470/810 that I'd like to use for this.

Also I was wondering if anyone has any tips on the best (or their preferred) way to set up a "big" raid6 array with a single filesystem. I'm probably going to stick with XFS, but I'm not married to it, if there's something better for a big media (audio, video, disk images, backups, etc) volume I'd love to hear about it.

So my array has finally finished resyncing, and I've run a simple iozone test on it formated with xfs, and I'm seeing some somewhat low write results:

moose@mrbig:/mnt/mrbig/data/test$ iozone -a -s 32G -r 8M
                                                            random  random
bkwd   record   stride
              KB  reclen   write rewrite    read    reread    read   write
read  rewrite     read   fwrite frewrite   fread  freread
        33554432    8192  212507  210382   630327   630852  372807  161710
388319  4922757   617347   210642   217122  717279   716150
Quoted 7 lines

Is this normal for a 7 disk (2TB seagate barracudas) raid array on a pcie x8 sas controller?

I was thinking it might be alignment issues, but there are no partitions on the disks, and xfs seems to have correctly set up the sunit and swidth settings (128/640 for a 7 disk raid6). While 200MB/s is probably more than I need day to day, I'd like to make sure it is set up properly.

So I've retested the array without bcache in th way, and my write speeds are still a fraction of the read speeds. Is this normal for a setup like mine?

The iozone results are a bit odd as well, I'm seeing the write speeds get worse as the record size goes up. To compare with the bcache result above:

random random
bkwd record stride
KB reclen write rewrite read reread read write
read rewrite read fwrite frewrite fread freread

        33554432    8192  177919  167524   632030   629077  371602  115228  

384030 4934570 618061 161562 176033 708542 709788

I'm pretty sure the bare results I got before I tested the bcache setup were better than this, a little over 200MB/s. But with the current kernel, these are the numbers I'm getting.

Specs:
Intel Core i3-2120
16GB 1333MHZ DDR3 ECC
30GB Vertex 1 SSD for /
IBM M1015 flashed with the LSI 9211-8i IT firmware
7x2TB Seagate Baracuda HDDs in raid6 unpartitioned and formatted with XFS

This system is currently dedicated to nothing but NAS duties. Later on I might get it doing other things, but right now, its actually doing nothing but running a RAID6 array that I haven't started using yet, so there shouldn't be too much getting in the way of the iozone tests.

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#3 lore raw
Quoted 3 lines · Thomas Fjellstrom

So I've retested the array without bcache in th way, and my write speeds are still a fraction of the read speeds. Is this normal for a setup like mine?

It looks like roughly 1/3 of the write performance? There is a non-insignificant penalty with RAID6 writes in IOPS, so I would look at whether your test is even valid; i.e. is it writing or rewriting in amounts that match what you will be using the array for? If not, disqualify the test and results and come up with something else that's more like the actual usage.

Is this for DAS? For big media files, IOPS is not typically what you need. You get large sequential writes.

Quoted 3 lines

IBM M1015 flashed with the LSI 9211-8i IT firmware
7x2TB Seagate Baracuda HDDs in raid6 unpartitioned and formatted with XFS

I'm not following. This is a SAS controller and you're using a Barracuda, which I think is a SATA drive? If you're using SAS drives, I'd expect them to be good enough quality and low UER that you could do RAID5 and avoid some of the write penalty. RAID 6 implies quite a few drives, have you considered RAID 10 instead? That card will do RAID 10 itself. The other possibility just RAID 0 the thing for DAS, and then back it up daily with rsync to a separate DAS RAID 0, or linear array.

Chris Murphy

#4 lore raw
Quoted 11 lines · you
Quoted 3 lines · Thomas Fjellstrom

So I've retested the array without bcache in th way, and my write speeds are still a fraction of the read speeds. Is this normal for a setup like mine?

It looks like roughly 1/3 of the write performance? There is a non-insignificant penalty with RAID6 writes in IOPS, so I would look at whether your test is even valid; i.e. is it writing or rewriting in amounts that match what you will be using the array for? If not, disqualify the test and results and come up with something else that's more like the actual usage.

A lot of it will be streaming. Some may end up being random read/writes. The test is just to gauge over all performance of the setup. 600MBs read is far more than I need, but having writes at 1/3 that seems odd to me.

Quoted 2 lines

Is this for DAS? For big media files, IOPS is not typically what you need. You get large sequential writes.

IOPS is not something I'm worrying about, but 1/3 the write throughput seems a bit off to me. I assume I've mis-configured something.

Quoted 10 lines
Quoted 2 lines

IBM M1015 flashed with the LSI 9211-8i IT firmware
7x2TB Seagate Baracuda HDDs in raid6 unpartitioned and formatted with XFS

I'm not following. This is a SAS controller and you're using a Barracuda, which I think is a SATA drive? If you're using SAS drives, I'd expect them to be good enough quality and low UER that you could do RAID5 and avoid some of the write penalty. RAID 6 implies quite a few drives, have you considered RAID 10 instead? That card will do RAID 10 itself. The other possibility just RAID 0 the thing for DAS, and then back it up daily with rsync to a separate DAS RAID 0, or linear array.

Its a relatively inexpensive ($80-100) 8 port SAS/SATA controller. And I have it flashed in IT mode, so theres no RAID support what so ever. I'm not a big fan of hardware based raid, as it tends to be rather proprietary and you end up having just one more weak link in the chain to account for (you get to buy identical backup cards to make sure you have spares, since no other cards will likely like any meta data, or on disk layout the original happened to use).

This is primarily a media and file share. RAID 10 comes with a rather large space penalty (50%) which is not something I want to deal with. I'd end up with an array the same size as my current 7x1TB RAID5, which is full. My idea was to make a 10TB array to replace the current one, and recommission some of those disks for use in a backup array (with some 3TB drives I picked up)

The reason I've selected RAID6 to begin with is I've read (on this mailing list, and on some hardware tech sites) that even with SAS drives, the rebuild/resync time on a large array using large disks (2TB+) is long enough that it gives more than enough time for another disk to hit a random read error, which will kick the disk out of the array, potentially giving you a double fault and taking the entire array out. This is something I'd like to avoid. But something I also don't want to spend 2x the money on drives for. Also going with parity based RAID so the array isn't totally out of commission for long stretches, even then theres some kind of error taking out one of the disks (and resync times are short due to using mdraid's write intent bitmap).

Quoted 4 lines

Chris Murphy--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#52 lore raw
In reply to Thomas Fjellstrom
Quoted 9 lines · Thomas Fjellstrom
moose@mrbig:/mnt/mrbig/data/test$ iozone -a -s 32G -r 8M
                                                             random  random
bkwd   record   stride
               KB  reclen   write rewrite    read    reread    read   write
read  rewrite     read   fwrite frewrite   fread  freread
         33554432    8192  212507  210382   630327   630852  372807  161710
388319  4922757   617347   210642   217122  717279   716150
Quoted 3 lines

Is this normal for a 7 disk (2TB seagate barracudas) raid array on a pcie x8 sas controller?

For comparo using the same command line. This is a running system and has a slight but measurable load on the array, but not enough that it should really impact the numbers.

This is 10 x WD 2TB Green drives (sloooow) in RAID-6 on a pair of those cards. Formatted ext4.

mpt2sas0: LSISAS2008: FWVersion(15.00.00.00), ChipRevision(0x02), BiosVersion(00.00.00.00)

md0 : active raid6 sdl[0] sdr[5] sdo[6] sdp[7] sdn[8] sdk[9] sdm[10] sdq[11] sds[4] sdf[12]

      15628106752 blocks super 1.2 level 6, 128k chunk, algorithm 2 
[10/10] [UUUUUUUUUU]
      bitmap: 2/15 pages [8KB], 65536KB chunk

                                                            random 
random    bkwd   record   stride
              KB  reclen   write rewrite    read    reread    read 
write    read  rewrite     read   fwrite frewrite   fread  freread
        33554432    8192  349745  448840   481170   488821  284313 
312892  355422  2288708   440818   397878   469964  478596   496619

Not sure this actually means anything though.

Regards,
Brad

#5 lore raw
In reply to Thomas Fjellstrom
Quoted 3 lines · Thomas Fjellstrom

A lot of it will be streaming. Some may end up being random read/writes. The test is just to gauge over all performance of the setup. 600MBs read is far more than I need, but having writes at 1/3 that seems odd to me.

Tell us how many disks there are, and what the chunk size is. It could be too small if you have too few disks which results in a small full stripe size for a video context. If you're using the default, it could be too big and you're getting a lot of RWM. Stan, and others, can better answer this.

You said these are unpartitioned disks, I think. In which case alignment of 4096 byte sectors isn't a factor if these are AF disks.

Unlikely to make up the difference is the scheduler. Parallel fs's like XFS don't perform nearly as well with CFQ, so you should have a kernel parameter elevator=noop.

Another thing to look at is md/stripe_cache_size which probably needs to be higher for your application.

Another thing to look at is if you're using XFS, what your mount options are. Invariably with an array of this size you need to be mounting with the inode64 option.

Quoted 5 lines

The reason I've selected RAID6 to begin with is I've read (on this mailing list, and on some hardware tech sites) that even with SAS drives, the rebuild/resync time on a large array using large disks (2TB+) is long enough that it gives more than enough time for another disk to hit a random read error,

This is true for high density consumer SATA drives. It's not nearly as applicable for low to moderate density nearline SATA which has an order of magnitude lower UER, or for enterprise SAS (and some enterprise SATA) which has yet another order of magnitude lower UER. So it depends on the disks, and the RAID size, and the backup/restore strategy.

Another way people get into trouble with the event you're talking about, is they don't do regular scrubs or poll drive SMART data. I have no empirical data, but I'd expect much better than order of magnitude lower array loss during a rebuild when the array is being properly maintained, rather than considering it a push button "it's magic" appliance to be forgotten about.

Chris Murphy

#6 lore raw
Quoted 8 lines · Chris Murphy
Quoted 3 lines · Thomas Fjellstrom

A lot of it will be streaming. Some may end up being random read/writes. The test is just to gauge over all performance of the setup. 600MBs read is far more than I need, but having writes at 1/3 that seems odd to me.

Tell us how many disks there are, and what the chunk size is. It could be too small if you have too few disks which results in a small full stripe size for a video context. If you're using the default, it could be too big and you're getting a lot of RWM. Stan, and others, can better answer this.

Thomas is using a benchmark, and a single one at that, to judge the performance. He's not using his actual workloads. Tuning/tweaking to increase the numbers in a benchmark could be detrimental to actual performance instead of providing a boost. One must be careful.

Regarding RAID6, it will always have horrible performance compared to non-parity RAID levels and even RAID5, for anything but full stripe aligned writes, which means writing new large files or doing large appends to existing files.

However, everything is relative. This RAID6 may have plenty of random and streaming write/read throughput for Thomas. But a single benchmark isn't going to inform him accurately.

Quoted 3 lines

You said these are unpartitioned disks, I think. In which case alignment of 4096 byte sectors isn't a factor if these are AF disks.

Unlikely to make up the difference is the scheduler. Parallel fs's like XFS don't perform nearly as well with CFQ, so you should have a kernel parameter elevator=noop.

If the HBAs have [BB|FB]WC then one should probably use noop as the cache schedules the actual IO to the drives. If the HBAs lack cache, then deadline often provides better performance. Testing of each is required on a system and workload basis. With two identical systems (hardware/RAID/OS) one may perform better with noop, the other with deadline. The determining factor is the applications' IO patterns.

Quoted 3 lines

Another thing to look at is md/stripe_cache_size which probably needs to be higher for your application.

Another thing to look at is if you're using XFS, what your mount options are. Invariably with an array of this size you need to be mounting with the inode64 option.

The desired allocator behavior is independent of array size but, once again, dependent on the workloads. inode64 is only needed for large filesystems with lots of files, where 1TB may not be enough for the directory inodes. Or, for mixed metadata/data heavy workloads.

For many workloads including databases, video ingestion, etc, the inode32 allocator is preferred, regardless of array size. This is the linux-raid list so I'll not go into detail of the XFS allocators.

Quoted 7 lines
Quoted 5 lines

The reason I've selected RAID6 to begin with is I've read (on this mailing list, and on some hardware tech sites) that even with SAS drives, the rebuild/resync time on a large array using large disks (2TB+) is long enough that it gives more than enough time for another disk to hit a random read error,

This is true for high density consumer SATA drives. It's not nearly as applicable for low to moderate density nearline SATA which has an order of magnitude lower UER, or for enterprise SAS (and some enterprise SATA) which has yet another order of magnitude lower UER. So it depends on the disks, and the RAID size, and the backup/restore strategy.

Yes, enterprise drives have a much larger spare sector pool.

WRT rebuild time, this is one more reason to use RAID10 or a concat of RAID1s. The rebuild time is low, constant, predictable. For 2TB drives about 5-6 hours at 100% rebuild rate. And rebuild time, for any array type, with gargantuan drives, is yet one more reason not to use the largest drives you can get your hands on. Using 1TB drives will cut that to 2.5-3 hours, and using 500GB drives will cut it down to 1.25-1.5 hours, as all these drives tend to have similar streaming write rates.

To wit, as a general rule I always build my arrays with the smallest drives I can get away with for the workload at hand. Yes, for a given TB total it increases acquisition cost of drives, HBAs, enclosures, and cables, and power consumption, but it also increases spindle count--thus performance-- while decreasing rebuild times substantially/dramatically.

Signature · 1 line
Stan
#29 lore raw
In reply to Chris Murphy
Quoted 9 lines · Chris Murphy
Quoted 3 lines · Thomas Fjellstrom

A lot of it will be streaming. Some may end up being random read/writes. The test is just to gauge over all performance of the setup. 600MBs read is far more than I need, but having writes at 1/3 that seems odd to me.

Tell us how many disks there are, and what the chunk size is. It could be too small if you have too few disks which results in a small full stripe size for a video context. If you're using the default, it could be too big and you're getting a lot of RWM. Stan, and others, can better answer this.

As stated earlier, its a 7x2TB array.

Quoted 2 lines

You said these are unpartitioned disks, I think. In which case alignment of 4096 byte sectors isn't a factor if these are AF disks.

They are AF disks.

Quoted 6 lines

Unlikely to make up the difference is the scheduler. Parallel fs's like XFS don't perform nearly as well with CFQ, so you should have a kernel parameter elevator=noop.

Another thing to look at is md/stripe_cache_size which probably needs to be higher for your application.

I'll look into it.

Quoted 3 lines

Another thing to look at is if you're using XFS, what your mount options are. Invariably with an array of this size you need to be mounting with the inode64 option.

I'm not sure, but I think that's the default.

Quoted 11 lines
Quoted 5 lines

The reason I've selected RAID6 to begin with is I've read (on this mailing list, and on some hardware tech sites) that even with SAS drives, the rebuild/resync time on a large array using large disks (2TB+) is long enough that it gives more than enough time for another disk to hit a random read error,

This is true for high density consumer SATA drives. It's not nearly as applicable for low to moderate density nearline SATA which has an order of magnitude lower UER, or for enterprise SAS (and some enterprise SATA) which has yet another order of magnitude lower UER. So it depends on the disks, and the RAID size, and the backup/restore strategy.

Plain old seagate baracudas, so not the best but at least they aren't greens.

Quoted 5 lines

Another way people get into trouble with the event you're talking about, is they don't do regular scrubs or poll drive SMART data. I have no empirical data, but I'd expect much better than order of magnitude lower array loss during a rebuild when the array is being properly maintained, rather than considering it a push button "it's magic" appliance to be forgotten about.

Debian seems to set up a weekly or monthly scrub, which I leave on due to reading that same fact.

Quoted 5 lines

Chris Murphy--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#7 lore raw
In reply to Stan Hoeppner
Quoted 18 lines · Stan Hoeppner
Quoted 11 lines · Chris Murphy
Quoted 4 lines · Thomas Fjellstrom

A lot of it will be streaming. Some may end up being random read/writes. The test is just to gauge over all performance of the setup. 600MBs read is far more than I need, but having writes at 1/3 that seems odd to me.

Tell us how many disks there are, and what the chunk size is. It could be too small if you have too few disks which results in a small full stripe size for a video context. If you're using the default, it could be too big and you're getting a lot of RWM. Stan, and others, can better answer this.

Thomas is using a benchmark, and a single one at that, to judge the performance. He's not using his actual workloads. Tuning/tweaking to increase the numbers in a benchmark could be detrimental to actual performance instead of providing a boost. One must be careful.

Quoted 4 lines

Regarding RAID6, it will always have horrible performance compared to non-parity RAID levels and even RAID5, for anything but full stripe aligned writes, which means writing new large files or doing large appends to existing files.

Considering its a rather simple use case, mostly streaming video, and misc file sharing for my home network, an iozone test should be rather telling. Especially the full test, from 4k up to 16mb

                                                            random  random    bkwd   record   stride                                   
              KB  reclen   write rewrite    read    reread    read   write    read  rewrite     read   fwrite frewrite   fread  freread
        33554432       4  243295  221756   628767   624081    1028    4627   16822  7468777    17740   233295   231092  582036   579131
        33554432       8  241134  225728   628264   627015    2027    8879   25977 10030302    19578   228923   233928  591478   584892
        33554432      16  233758  228122   633406   618248    3952   13635   35676 10166457    19968   227599   229698  579267   576850
        33554432      32  232390  219484   625968   625627    7604   18800   44252 10728450    24976   216880   222545  556513   555371
        33554432      64  222936  206166   631659   627823   14112   22837   52259 11243595    30251   196243   192755  498602   494354
        33554432     128  214740  182619   628604   626407   25088   26719   64912 11232068    39867   198638   185078  463505   467853
        33554432     256  202543  185964   626614   624367   44363   34763   73939 10148251    62349   176724   191899  593517   595646
        33554432     512  208081  188584   632188   629547   72617   39145   84876  9660408    89877   182736   172912  610681   608870
        33554432    1024  196429  166125   630785   632413  116793   51904  133342  8687679   121956   168756   175225  620587   616722
        33554432    2048  185399  167484   622180   627606  188571   70789  218009  5357136   370189   171019   166128  637830   637120
        33554432    4096  198340  188695   632693   628225  289971   95211  278098  4836433   611529   161664   170469  665617   655268
        33554432    8192  177919  167524   632030   629077  371602  115228  384030  4934570   618061   161562   176033  708542   709788
        33554432   16384  196639  183744   631478   627518  485622  133467  462861  4890426   644615   175411   179795  725966   734364
Quoted 3 lines

However, everything is relative. This RAID6 may have plenty of random and streaming write/read throughput for Thomas. But a single benchmark isn't going to inform him accurately.

200MB/s may be enough, but the difference between the read and write throughput is a bit unexpected. It's not a weak machine (core i3-2120, dual core 3.2Ghz with HT, 16GB ECC 1333Mhz ram), and this is basically all its going to be doing.

Quoted 7 lines
Quoted 6 lines

You said these are unpartitioned disks, I think. In which case alignment of 4096 byte sectors isn't a factor if these are AF disks.

Unlikely to make up the difference is the scheduler. Parallel fs's like XFS don't perform nearly as well with CFQ, so you should have a kernel parameter elevator=noop.

Quoted 6 lines

If the HBAs have [BB|FB]WC then one should probably use noop as the cache schedules the actual IO to the drives. If the HBAs lack cache, then deadline often provides better performance. Testing of each is required on a system and workload basis. With two identical systems (hardware/RAID/OS) one may perform better with noop, the other with deadline. The determining factor is the applications' IO patterns.

Mostly streaming reads, some long rsync's to copy stuff back and forth, file share duties (downloads etc).

Quoted 7 lines
Quoted 6 lines

Another thing to look at is md/stripe_cache_size which probably needs to be higher for your application.

Another thing to look at is if you're using XFS, what your mount options are. Invariably with an array of this size you need to be mounting with the inode64 option.

Quoted 8 lines

The desired allocator behavior is independent of array size but, once again, dependent on the workloads. inode64 is only needed for large filesystems with lots of files, where 1TB may not be enough for the directory inodes. Or, for mixed metadata/data heavy workloads.

For many workloads including databases, video ingestion, etc, the inode32 allocator is preferred, regardless of array size. This is the linux-raid list so I'll not go into detail of the XFS allocators.

If you have the time and the desire, I'd like to hear about it off list.

Quoted 22 lines
Quoted 11 lines
Quoted 5 lines

The reason I've selected RAID6 to begin with is I've read (on this mailing list, and on some hardware tech sites) that even with SAS drives, the rebuild/resync time on a large array using large disks (2TB+) is long enough that it gives more than enough time for another disk to hit a random read error,

This is true for high density consumer SATA drives. It's not nearly as applicable for low to moderate density nearline SATA which has an order of magnitude lower UER, or for enterprise SAS (and some enterprise SATA) which has yet another order of magnitude lower UER. So it depends on the disks, and the RAID size, and the backup/restore strategy.

Yes, enterprise drives have a much larger spare sector pool.

WRT rebuild time, this is one more reason to use RAID10 or a concat of RAID1s. The rebuild time is low, constant, predictable. For 2TB drives about 5-6 hours at 100% rebuild rate. And rebuild time, for any array type, with gargantuan drives, is yet one more reason not to use the largest drives you can get your hands on. Using 1TB drives will cut that to 2.5-3 hours, and using 500GB drives will cut it down to 1.25-1.5 hours, as all these drives tend to have similar streaming write rates.

Quoted 5 lines

To wit, as a general rule I always build my arrays with the smallest drives I can get away with for the workload at hand. Yes, for a given TB total it increases acquisition cost of drives, HBAs, enclosures, and cables, and power consumption, but it also increases spindle count--thus performance-- while decreasing rebuild times substantially/dramatically.

I'd go raid10 or something if I had the space, but this little 10TB nas (which is the goal, a small, quiet, not too slow, 10TB nas with some kind of redundancy) only fits 7 3.5" HDDs.

Maybe sometime in the future I'll get a big 3 or 4 u case with a crap load of 3.5" HDD bays, but for now, this is what I have (as well as my old array, 7x1TB RAID5+XFS in 4in3 hot swap bays with room for 8 drives, but haven't bothered to expand the old array, and I have the new one almost ready to go).

I don't know if it impacts anything at all, but when burning in these drives after I bought them, I ran the same full iozone test a couple times, and each drive shows 150MB/s read, and similar write times (100-120+?). It impressed me somewhat, to see a mechanical hard drive go that fast. I remember back a few years ago thinking 80MBs was fast for a HDD.

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#8 lore raw
Quoted 3 lines · Thomas Fjellstrom
Quoted 2 lines · Stan Hoeppner
Quoted 1 line · Chris Murphy

On Jan 10, 2013, at 3:49 AM, Thomas Fjellstrom <[email protected]>

Quoted 135 lines · wrote:
Quoted 16 lines
Quoted 10 lines
Quoted 4 lines

A lot of it will be streaming. Some may end up being random read/writes. The test is just to gauge over all performance of the setup. 600MBs read is far more than I need, but having writes at 1/3 that seems odd to me.

Tell us how many disks there are, and what the chunk size is. It could be too small if you have too few disks which results in a small full stripe size for a video context. If you're using the default, it could be too big and you're getting a lot of RWM. Stan, and others, can better answer this.

Thomas is using a benchmark, and a single one at that, to judge the performance. He's not using his actual workloads. Tuning/tweaking to increase the numbers in a benchmark could be detrimental to actual performance instead of providing a boost. One must be careful.

Quoted 4 lines

Regarding RAID6, it will always have horrible performance compared to non-parity RAID levels and even RAID5, for anything but full stripe aligned writes, which means writing new large files or doing large appends to existing files.

Considering its a rather simple use case, mostly streaming video, and misc file sharing for my home network, an iozone test should be rather telling. Especially the full test, from 4k up to 16mb

random random
bkwd record stride KB reclen write rewrite read reread
read write read rewrite read fwrite frewrite fread freread
33554432 4 243295 221756 628767 624081 1028 4627 16822
7468777 17740 233295 231092 582036 579131 33554432 8
241134 225728 628264 627015 2027 8879 25977 10030302 19578
228923 233928 591478 584892 33554432 16 233758 228122
633406 618248 3952 13635 35676 10166457 19968 227599
229698 579267 576850 33554432 32 232390 219484 625968 625627
7604 18800 44252 10728450 24976 216880 222545 556513
555371 33554432 64 222936 206166 631659 627823 14112 22837
52259 11243595 30251 196243 192755 498602 494354 33554432
128 214740 182619 628604 626407 25088 26719 64912 11232068
39867 198638 185078 463505 467853 33554432 256 202543 185964
626614 624367 44363 34763 73939 10148251 62349 176724
191899 593517 595646 33554432 512 208081 188584 632188 629547
72617 39145 84876 9660408 89877 182736 172912 610681
608870 33554432 1024 196429 166125 630785 632413 116793 51904
133342 8687679 121956 168756 175225 620587 616722 33554432
2048 185399 167484 622180 627606 188571 70789 218009 5357136
370189 171019 166128 637830 637120 33554432 4096 198340 188695
632693 628225 289971 95211 278098 4836433 611529 161664
170469 665617 655268 33554432 8192 177919 167524 632030 629077
371602 115228 384030 4934570 618061 161562 176033 708542
709788 33554432 16384 196639 183744 631478 627518 485622 133467
462861 4890426 644615 175411 179795 725966 734364

Quoted 3 lines

However, everything is relative. This RAID6 may have plenty of random and streaming write/read throughput for Thomas. But a single benchmark isn't going to inform him accurately.

200MB/s may be enough, but the difference between the read and write throughput is a bit unexpected. It's not a weak machine (core i3-2120, dual core 3.2Ghz with HT, 16GB ECC 1333Mhz ram), and this is basically all its going to be doing.

Quoted 7 lines
Quoted 6 lines

You said these are unpartitioned disks, I think. In which case alignment of 4096 byte sectors isn't a factor if these are AF disks.

Unlikely to make up the difference is the scheduler. Parallel fs's like XFS don't perform nearly as well with CFQ, so you should have a kernel parameter elevator=noop.

Quoted 6 lines

If the HBAs have [BB|FB]WC then one should probably use noop as the cache schedules the actual IO to the drives. If the HBAs lack cache, then deadline often provides better performance. Testing of each is required on a system and workload basis. With two identical systems (hardware/RAID/OS) one may perform better with noop, the other with deadline. The determining factor is the applications' IO patterns.

Mostly streaming reads, some long rsync's to copy stuff back and forth, file share duties (downloads etc).

Quoted 7 lines
Quoted 6 lines

Another thing to look at is md/stripe_cache_size which probably needs to be higher for your application.

Another thing to look at is if you're using XFS, what your mount options are. Invariably with an array of this size you need to be mounting with the inode64 option.

Quoted 8 lines

The desired allocator behavior is independent of array size but, once again, dependent on the workloads. inode64 is only needed for large filesystems with lots of files, where 1TB may not be enough for the directory inodes. Or, for mixed metadata/data heavy workloads.

For many workloads including databases, video ingestion, etc, the inode32 allocator is preferred, regardless of array size. This is the linux-raid list so I'll not go into detail of the XFS allocators.

If you have the time and the desire, I'd like to hear about it off list.

Quoted 23 lines
Quoted 6 lines
Quoted 5 lines

The reason I've selected RAID6 to begin with is I've read (on this mailing list, and on some hardware tech sites) that even with SAS drives, the rebuild/resync time on a large array using large disks (2TB+) is long enough that it gives more than enough time for another disk to hit a random read error,

Quoted 6 lines

This is true for high density consumer SATA drives. It's not nearly as applicable for low to moderate density nearline SATA which has an order of magnitude lower UER, or for enterprise SAS (and some enterprise SATA) which has yet another order of magnitude lower UER. So it depends on the disks, and the RAID size, and the backup/restore strategy.

Yes, enterprise drives have a much larger spare sector pool.

WRT rebuild time, this is one more reason to use RAID10 or a concat of RAID1s. The rebuild time is low, constant, predictable. For 2TB drives about 5-6 hours at 100% rebuild rate. And rebuild time, for any array type, with gargantuan drives, is yet one more reason not to use the largest drives you can get your hands on. Using 1TB drives will cut that to 2.5-3 hours, and using 500GB drives will cut it down to 1.25-1.5 hours, as all these drives tend to have similar streaming write rates.

Quoted 5 lines

To wit, as a general rule I always build my arrays with the smallest drives I can get away with for the workload at hand. Yes, for a given TB total it increases acquisition cost of drives, HBAs, enclosures, and cables, and power consumption, but it also increases spindle count--thus performance-- while decreasing rebuild times substantially/dramatically.

I'd go raid10 or something if I had the space, but this little 10TB nas (which is the goal, a small, quiet, not too slow, 10TB nas with some kind of redundancy) only fits 7 3.5" HDDs.

Maybe sometime in the future I'll get a big 3 or 4 u case with a crap load of 3.5" HDD bays, but for now, this is what I have (as well as my old array, 7x1TB RAID5+XFS in 4in3 hot swap bays with room for 8 drives, but haven't bothered to expand the old array, and I have the new one almost ready to go).

Quoted 6 lines

I don't know if it impacts anything at all, but when burning in these drives after I bought them, I ran the same full iozone test a couple times, and each drive shows 150MB/s read, and similar write times (100-120+?). It impressed me somewhat, to see a mechanical hard drive go that fast. I remember back a few years ago thinking 80MBs was fast for a HDD.

I should note, it might do some p2p duties in the future. Not sure about that.

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#30 lore raw
In reply to Thomas Fjellstrom
Quoted 6 lines · Thomas Fjellstrom
Quoted 5 lines · Chris Murphy
Quoted 3 lines · Thomas Fjellstrom

A lot of it will be streaming. Some may end up being random read/writes. The test is just to gauge over all performance of the setup. 600MBs read is far more than I need, but having writes at 1/3 that seems odd to me.

Quoted 6 lines
Quoted 4 lines

Tell us how many disks there are, and what the chunk size is. It could be too small if you have too few disks which results in a small full stripe size for a video context. If you're using the default, it could be too big and you're getting a lot of RWM. Stan, and others, can better answer this.

As stated earlier, its a 7x2TB array.

OK fair enough, and as asked earlier, what's the chunk size?

Quoted 6 lines
Quoted 4 lines

Another thing to look at is if you're using XFS, what your mount options are. Invariably with an array of this size you need to be mounting with the inode64 option.

I'm not sure, but I think that's the default.

It's not but as Stan writes it may not be preferred for your application.

Quoted 3 lines
Quoted 1 line

Plain old seagate baracudas, so not the best but at least they aren't greens.

They probably have a high ERC time out as all consumer disks do so you should also check /sys/block/sdX/device/timeout and make sure it's not significantly less than the drive. It may be possible for smartctl or hdparm to figure out what the drive ERC timeout is.

http://cgi.csc.liv.ac.uk/~greg/projects/erc/

Quoted 4 lines

Debian seems to set up a weekly or monthly scrub, which I leave on due to reading that same fact.

Unless there's a script to email you the results, you'll need to check it periodically. Or write a script that checks for reported errors and only sends an email if that's the case.

Chris Murphy

#31 lore raw
Quoted 4 lines · Chris Murphy

They probably have a high ERC time out as all consumer disks do so you should also check /sys/block/sdX/device/timeout and make sure it's not significantly less than the drive. It may be possible for smartctl or hdparm to figure out what the drive ERC timeout is.

http://cgi.csc.liv.ac.uk/~greg/projects/erc/

Actually what I wrote is misleading to the point it's wrong. You want the linux device time out to be greater than the device timeout. The device needs to be allowed to give up, and report back a read error to linux/md, so that md knows it should reconstruct the missing data from parity, and overwrite the (obviously) bad blocks causing the read error.

If the linux device time out is even a little bit less than the drive's timeout, md never gets the sector read error, doesn't repair it, since linux boots the whole drive. Now instead of repairing a few sectors, you have a degraded array on your hands. Usual consumer drive time outs are quite high, they can be up to a couple minutes long. Linux device time out is 30 seconds.

Chris Murphy

#47 lore raw
In reply to Thomas Fjellstrom
Quoted 7 lines · Thomas Fjellstrom
Quoted 3 lines · Chris Murphy

Another thing to look at is if you're using XFS, what your mount options are. Invariably with an array of this size you need to be mounting with the inode64 option.

I'm not sure, but I think that's the default.

No, inode32 has always been the default allocator. It was decided just recently to make inode64 the default, and the patcheset for this was committed on 9/20/2012, ~3 months ago, into 3.6-rc1-17:

http://oss.sgi.com/archives/xfs/2012-09/msg00397.html

So with 3.6+ kernels inode64 is the new default. Any current mainstream distro kernel defaults to inode32.

Worth noting: if you upgrade the kernel on a system with existing inode32 XFS filesystems the allocator for these will remain inode32 unless the mount option is manually changed. This is the same behavior as with current kernels. New filesystems created after upgrading to a 64 bit kernel w/this patch set will be mounted with inode64. IIRC 32 bit kernels are limited to the inode32 allocator and 32 bit inodes.

There are many workloads that prefer, or even require, 32bit inodes, and/or the behavior available with the inode32 allocator. Thus it would not be smart to auto convert them to inode64 after a kernel upgrade.

Signature · 1 line
Stan
#40 lore raw
In reply to Chris Murphy
Quoted 3 lines · you
Quoted 2 lines · Thomas Fjellstrom
Quoted 1 line · Chris Murphy

On Jan 10, 2013, at 3:49 AM, Thomas Fjellstrom <[email protected]>

Quoted 11 lines · wrote:
Quoted 11 lines
Quoted 10 lines
Quoted 4 lines

A lot of it will be streaming. Some may end up being random read/writes. The test is just to gauge over all performance of the setup. 600MBs read is far more than I need, but having writes at 1/3 that seems odd to me.

Tell us how many disks there are, and what the chunk size is. It could be too small if you have too few disks which results in a small full stripe size for a video context. If you're using the default, it could be too big and you're getting a lot of RWM. Stan, and others, can better answer this.

Quoted 3 lines
Quoted 1 line

As stated earlier, its a 7x2TB array.

OK fair enough, and as asked earlier, what's the chunk size?

Ah, sorry, I missed that bit. I didn't tweak the chunk size, so I have the default 512K.

Quoted 7 lines
Quoted 5 lines
Quoted 3 lines

Another thing to look at is if you're using XFS, what your mount options are. Invariably with an array of this size you need to be mounting with the inode64 option.

I'm not sure, but I think that's the default.

It's not but as Stan writes it may not be preferred for your application.

Hm, ok, it is in my mount line, so I'll try it with that off. Though I would be interested in hearing from Stan why it may not be good.

Quoted 8 lines
Quoted 2 lines

Plain old seagate baracudas, so not the best but at least they aren't greens.

They probably have a high ERC time out as all consumer disks do so you should also check /sys/block/sdX/device/timeout and make sure it's not significantly less than the drive. It may be possible for smartctl or hdparm to figure out what the drive ERC timeout is.

Quoted 8 lines

http://cgi.csc.liv.ac.uk/~greg/projects/erc/

Quoted 2 lines

Debian seems to set up a weekly or monthly scrub, which I leave on due to reading that same fact.

Unless there's a script to email you the results, you'll need to check it periodically. Or write a script that checks for reported errors and only sends an email if that's the case.

I believe it will send a mail to root. It seems as if its a mdadm/mdmon feature, as the config option is in mdadm.conf. I've set it to send a mail to my main email address, so I should see alerts.

Quoted 6 lines

Chris Murphy

--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#32 lore raw
In reply to Chris Murphy
Quoted 14 lines · Chris Murphy
Quoted 6 lines · Chris Murphy

They probably have a high ERC time out as all consumer disks do so you should also check /sys/block/sdX/device/timeout and make sure it's not significantly less than the drive. It may be possible for smartctl or hdparm to figure out what the drive ERC timeout is.

http://cgi.csc.liv.ac.uk/~greg/projects/erc/

Actually what I wrote is misleading to the point it's wrong. You want the linux device time out to be greater than the device timeout. The device needs to be allowed to give up, and report back a read error to linux/md, so that md knows it should reconstruct the missing data from parity, and overwrite the (obviously) bad blocks causing the read error.

Quoted 7 lines

If the linux device time out is even a little bit less than the drive's timeout, md never gets the sector read error, doesn't repair it, since linux boots the whole drive. Now instead of repairing a few sectors, you have a degraded array on your hands. Usual consumer drive time outs are quite high, they can be up to a couple minutes long. Linux device time out is 30 seconds.

Hm, ok. I'll look into that, and set those up properly.

Thanks.

Quoted 4 lines

Chris Murphy--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#41 lore raw
In reply to Thomas Fjellstrom
Quoted 4 lines · Thomas Fjellstrom
Quoted 1 line

It's not but as Stan writes it may not be preferred for your application.

Hm, ok, it is in my mount line, so I'll try it with that off. Though I would be interested in hearing from Stan why it may not be good.

You should not do this. This parameter is not a toggle switch intended to be flipped on/off at will, but changed only once and left there.

Never change XFS parameters willy-nilly without knowing the consequences. And currently you certainly do not know them.

I don't have time for the detailed explanation. Ask on the XFS list.

Signature · 1 line
Stan
#33 lore raw
In reply to Chris Murphy
Quoted 18 lines · Chris Murphy
Quoted 7 lines · Chris Murphy

They probably have a high ERC time out as all consumer disks do so you should also check /sys/block/sdX/device/timeout and make sure it's not significantly less than the drive. It may be possible for smartctl or hdparm to figure out what the drive ERC timeout is.

http://cgi.csc.liv.ac.uk/~greg/projects/erc/

Actually what I wrote is misleading to the point it's wrong. You want the linux device time out to be greater than the device timeout. The device needs to be allowed to give up, and report back a read error to linux/md, so that md knows it should reconstruct the missing data from parity, and overwrite the (obviously) bad blocks causing the read error.

Quoted 6 lines

If the linux device time out is even a little bit less than the drive's timeout, md never gets the sector read error, doesn't repair it, since linux boots the whole drive. Now instead of repairing a few sectors, you have a degraded array on your hands. Usual consumer drive time outs are quite high, they can be up to a couple minutes long. Linux device time out is 30 seconds.

This isn't quite right. When the linux driver stack times out, it passes the error to MD. MD doesn't care if the drive reported the error, or if the controller reported the error, it just knows that it couldn't read that block. It goes to recovery, which typically generates the replacement data in a few milliseconds, and tries to write back to the first disk. *That* instantly fails, since the controller is resetting the link and the drive is still in la-la land trying to read the data. MD will tolerate several bad reads before it kicks out a drive, but will immediately kick if a write fails.

By the time you come to investigate, the drive has completed its timeout, the link has reset, and the otherwise good drive is sitting idle (failed).

Any array running with mismatched timeouts will kick a drive on every unrecoverable read error, where it would likely have just fixed it.

Sadly, many hobbyist arrays are built with desktop drives, and the timeouts are left mismatched. When that hobbyist later learns s/he should be scrubbing, the long-overdue scrub is very likely to produce UREs on multiple drives (BOOM).

Phil

#42 lore raw
In reply to Stan Hoeppner
Quoted 9 lines · Stan Hoeppner
Quoted 5 lines · Thomas Fjellstrom
Quoted 2 lines

It's not but as Stan writes it may not be preferred for your application.

Hm, ok, it is in my mount line, so I'll try it with that off. Though I would be interested in hearing from Stan why it may not be good.

You should not do this. This parameter is not a toggle switch intended to be flipped on/off at will, but changed only once and left there.

Makes me wonder why they are mount options if they aren't meant to ever be changed?

Quoted 4 lines

Never change XFS parameters willy-nilly without knowing the consequences. And currently you certainly do not know them.

I don't have time for the detailed explanation. Ask on the XFS list.

Alright, thanks for your help :)

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#48 lore raw
In reply to Stan Hoeppner
Quoted 11 lines · Stan Hoeppner
Quoted 6 lines · Thomas Fjellstrom
Quoted 3 lines · Chris Murphy

Another thing to look at is if you're using XFS, what your mount options are. Invariably with an array of this size you need to be mounting with the inode64 option.

I'm not sure, but I think that's the default.

No, inode32 has always been the default allocator. It was decided just recently to make inode64 the default, and the patcheset for this was committed on 9/20/2012, ~3 months ago, into 3.6-rc1-17:

Ahh. I somewhat sorta try and keep up to date on kernel happenings, and after a while things get muddled. So that's probably where I got that from.

Quoted 15 lines

http://oss.sgi.com/archives/xfs/2012-09/msg00397.html

So with 3.6+ kernels inode64 is the new default. Any current mainstream distro kernel defaults to inode32.

Worth noting: if you upgrade the kernel on a system with existing inode32 XFS filesystems the allocator for these will remain inode32 unless the mount option is manually changed. This is the same behavior as with current kernels. New filesystems created after upgrading to a 64 bit kernel w/this patch set will be mounted with inode64. IIRC 32 bit kernels are limited to the inode32 allocator and 32 bit inodes.

There are many workloads that prefer, or even require, 32bit inodes, and/or the behavior available with the inode32 allocator. Thus it would not be smart to auto convert them to inode64 after a kernel upgrade.

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#34 lore raw
In reply to Phil Turmel
Quoted 36 lines · Phil Turmel
Quoted 18 lines · Chris Murphy
Quoted 7 lines · Chris Murphy

They probably have a high ERC time out as all consumer disks do so you should also check /sys/block/sdX/device/timeout and make sure it's not significantly less than the drive. It may be possible for smartctl or hdparm to figure out what the drive ERC timeout is.

http://cgi.csc.liv.ac.uk/~greg/projects/erc/

Actually what I wrote is misleading to the point it's wrong. You want the linux device time out to be greater than the device timeout. The device needs to be allowed to give up, and report back a read error to linux/md, so that md knows it should reconstruct the missing data from parity, and overwrite the (obviously) bad blocks causing the read error.

Quoted 6 lines

If the linux device time out is even a little bit less than the drive's timeout, md never gets the sector read error, doesn't repair it, since linux boots the whole drive. Now instead of repairing a few sectors, you have a degraded array on your hands. Usual consumer drive time outs are quite high, they can be up to a couple minutes long. Linux device time out is 30 seconds.

This isn't quite right. When the linux driver stack times out, it passes the error to MD. MD doesn't care if the drive reported the error, or if the controller reported the error, it just knows that it couldn't read that block. It goes to recovery, which typically generates the replacement data in a few milliseconds, and tries to write back to the first disk. *That* instantly fails, since the controller is resetting the link and the drive is still in la-la land trying to read the data. MD will tolerate several bad reads before it kicks out a drive, but will immediately kick if a write fails.

Quoted 3 lines

By the time you come to investigate, the drive has completed its timeout, the link has reset, and the otherwise good drive is sitting idle (failed).

I admit I omitted the handling of the error md gets in the case of linux itself timing out the drive, because I don't know how that's handled. For example:

When you say, "the linux driver stack times out, it passes the error to MD," what error is passed? Is it the same (I think it's 0x40) read error that the drive would have produced, along with affected LBAs? Does the driver know the affected LBA's, maybe by inference? Otherwise md wouldn't know what replacement data to generate. Or is it a different error, neither a read nor write error, that causes md to bounce the drive wholesale?

Quoted 3 lines

Any array running with mismatched timeouts will kick a drive on every unrecoverable read error, where it would likely have just fixed it.

This is the key phrase I was trying to get at.

Quoted 4 lines

Sadly, many hobbyist arrays are built with desktop drives, and the timeouts are left mismatched. When that hobbyist later learns s/he should be scrubbing, the long-overdue scrub is very likely to produce UREs on multiple drives (BOOM).

Or even if they have been scrubbing all along. If the drive recovers the data inside of 30 seconds, and also doesn't relocated the data to a new sector (? I have no idea when drives do this on their own; I know they will do it on a write failure but I'm unclear when they do it on persistent read "difficulty") the scrub has no means of even being aware there's a problem to fix!

Given the craptastic state of affairs that manufacturers disallow a simple setting change to ask the drive to do LESS error correction, the recommendation to buy a different drive that can be so configured, is the best suggestion. Alternative 1 is to change the linux driver timeout to maybe upwards of two minutes, and then deal with the fall out of that behavior, which could be worse than a drive being booted out of the array sooner. And a very distant alternative 2 is to zero or Secure Erase the drive every so often, in hopes of avoiding bad sectors altogether — is tedious, as well as implies either putting the drive into a degraded state, or cycling a spare drive. And at the point you're going to buy a spare drive for this fiasco, you might as well just buy drives suited for the purpose.

How's that?

Chris Murphy--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

#43 lore raw
In reply to Thomas Fjellstrom
Quoted 5 lines · Thomas Fjellstrom
Quoted 4 lines · Stan Hoeppner
Quoted 3 lines · Thomas Fjellstrom
Quoted 2 lines

It's not but as Stan writes it may not be preferred for your application.

Quoted 8 lines
Quoted 5 lines
Quoted 2 lines

Hm, ok, it is in my mount line, so I'll try it with that off. Though I would be interested in hearing from Stan why it may not be good.

You should not do this. This parameter is not a toggle switch intended to be flipped on/off at will, but changed only once and left there.

Makes me wonder why they are mount options if they aren't meant to ever be changed?

I'll answer that question with a question: If you were to implement a new (secondary) allocator on a 10 year old filesystem, by what mechanism would you have the user enable it?

You can't change the allocator while the filesystem is mounted, so you can't do this with a sysctl. So if you must remount the filesystem to enable the new allocator, where do you enable it?

Make sense yet?

Quoted 6 lines
Quoted 4 lines

Never change XFS parameters willy-nilly without knowing the consequences. And currently you certainly do not know them.

I don't have time for the detailed explanation. Ask on the XFS list.

Alright, thanks for your help :)

And as the last few times over many months, you never post to the XFS list. Which tells me you really don't care to learn this stuff.

Signature · 1 line
Stan
#49 lore raw
In reply to Chris Murphy
Quoted 3 lines

Unlikely to make up the difference is the scheduler. Parallel fs's like XFS don't perform nearly as well with CFQ, so you should have a kernel parameter elevator=noop.

uh… how can the filesystem chosen be relevant to the disk elevator? CFQ will try to optimize access to reduce seeks and should be completely independent on the filesystem used on top. Also, if you really want to disable CFQ (which you shouldn't do on rotating rust, IMO), better use deadline (which is default on newer kernels).

Vennlige hilsener / Best regards

roy
--
Roy Sigurd Karlsbakk
(+47) 98013356
[email protected]
http://blogg.karlsbakk.net/
GPG Public key: http://karlsbakk.net/roysigurdkarlsbakk.pubkey.txt
--
I all pedagogikk er det essensielt at pensum presenteres intelligibelt. Det er et elementært imperativ for alle pedagoger å unngå eksessiv anvendelse av idiomer med xenotyp etymologi. I de fleste tilfeller eksisterer adekvate og relevante synonymer på norsk. --
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

#50 lore raw
Quoted 5 lines · Roy Sigurd Karlsbakk
Quoted 3 lines

Unlikely to make up the difference is the scheduler. Parallel fs's like XFS don't perform nearly as well with CFQ, so you should have a kernel parameter elevator=noop.

uh… how can the filesystem chosen be relevant to the disk elevator?

It's the other way round. The chosen elevator can cause problems with the filesystem. You should find this relevant conversation amongst the lead XFS developers educational:

http://oss.sgi.com/archives/xfs/2011-07/msg00464.html

Quoted 1 line

CFQ will try to optimize access to reduce seeks

"Completely Fair Queuing" -- The name alone tells you how it works. It most certainly does not do what you state. Please read the brief Wikipedia article: http://en.wikipedia.org/wiki/CFQ

Quoted 1 line

and should be completely independent on the filesystem used on top.

Operative word: "should"

The USA should not be $16 Trillion in debt, but it is. By international law whales should not be killed, but they still are. Etc.

Signature · 6 lines
Stan

--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html
#44 lore raw
In reply to Stan Hoeppner
Quoted 19 lines · Stan Hoeppner
Quoted 5 lines · Thomas Fjellstrom
Quoted 4 lines · Stan Hoeppner
Quoted 3 lines · Thomas Fjellstrom
Quoted 2 lines

It's not but as Stan writes it may not be preferred for your application.

Quoted 8 lines
Quoted 5 lines
Quoted 2 lines

Hm, ok, it is in my mount line, so I'll try it with that off. Though I would be interested in hearing from Stan why it may not be good.

You should not do this. This parameter is not a toggle switch intended to be flipped on/off at will, but changed only once and left there.

Makes me wonder why they are mount options if they aren't meant to ever be changed?

I'll answer that question with a question: If you were to implement a new (secondary) allocator on a 10 year old filesystem, by what mechanism would you have the user enable it?

Quoted 5 lines

You can't change the allocator while the filesystem is mounted, so you can't do this with a sysctl. So if you must remount the filesystem to enable the new allocator, where do you enable it?

Make sense yet?

Could have a tool like tune2fs, if you have to remount anyway, putting the non option option behind a tool would make it less dangerous for people who don't know they aren't actually changeable.

Quoted 9 lines
Quoted 6 lines
Quoted 4 lines

Never change XFS parameters willy-nilly without knowing the consequences. And currently you certainly do not know them.

I don't have time for the detailed explanation. Ask on the XFS list.

Alright, thanks for your help :)

And as the last few times over many months, you never post to the XFS list. Which tells me you really don't care to learn this stuff.

I don't think theres a reason to be hostile. I had been meaning to join the XFS list, but usually, I get so far into looking into this stuff, before I run out of time and have to get back to work. As it is this new NAS box has been sitting on the floor doing nothing for a month or so waiting for me to have time to finish configuring it.

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#51 lore raw
In reply to Stan Hoeppner
Quoted 7 lines
Quoted 1 line

uh… how can the filesystem chosen be relevant to the disk elevator?

It's the other way round. The chosen elevator can cause problems with the filesystem. You should find this relevant conversation amongst the lead XFS developers educational:

http://oss.sgi.com/archives/xfs/2011-07/msg00464.html

This article is about using CFQ with RAID controllers with write cache, which isn't something I'd recommend. CFQ is, if I'm not mistaken, good if Linux has local access to each disk, and the disks are spinning (!SSD).

Quoted 5 lines
Quoted 1 line

CFQ will try to optimize access to reduce seeks

"Completely Fair Queuing" -- The name alone tells you how it works. It most certainly does not do what you state. Please read the brief Wikipedia article: http://en.wikipedia.org/wiki/CFQ

It's how it's designed, for spinning rust.

Quoted 7 lines
Quoted 1 line

and should be completely independent on the filesystem used on top.

Operative word: "should"

The USA should not be $16 Trillion in debt, but it is. By international
law whales should not be killed, but they still are. Etc.

Well, most things don't work as they are intended to do, but I guess CFQ works pretty well for spinning rust directly attached to a Linux box.

The default scheduler was changed in kernel, but only because SSDs are getting more common. Would those kernel developers know their things?

Vennlige hilsener / Best regards

roy
--
Roy Sigurd Karlsbakk
(+47) 98013356
[email protected]
http://blogg.karlsbakk.net/
GPG Public key: http://karlsbakk.net/roysigurdkarlsbakk.pubkey.txt
--
I all pedagogikk er det essensielt at pensum presenteres intelligibelt. Det er et elementært imperativ for alle pedagoger å unngå eksessiv anvendelse av idiomer med xenotyp etymologi. I de fleste tilfeller eksisterer adekvate og relevante synonymer på norsk. --
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

#45 lore raw
In reply to Thomas Fjellstrom
Quoted 5 lines · Thomas Fjellstrom
Quoted 1 line · you

OK fair enough, and as asked earlier, what's the chunk size?

Ah, sorry, I missed that bit. I didn't tweak the chunk size, so I have the default 512K.

OK now that the subject has been sufficiently detoured…

Benchmarking can perhaps help you isolate causes for problems you're having, but you haven't said what problems you're having. You're using benchmarking data to go looking for a problem. This is a GigE network to the NAS? If it's wireless, who cares, all of these array numbers are better than wireless bandwidth and latency. If it's GigE, all of your sequential read write numbers exceed the bandwidth of wired. So what's the problem? You want better random read writes? Rebuild the array with a 32KB or 64KB chunk size, knowing you may take a small hit on the larger sequential read/writes.

Chris Murphy--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

#35 lore raw
In reply to Chris Murphy
Quoted 2 lines · Chris Murphy

On Jan 11, 2013, at 5:47 PM, Phil Turmel <[email protected]> wrote:

[trim /]

Quoted 19 lines
Quoted 11 lines

This isn't quite right. When the linux driver stack times out, it
passes the error to MD. MD doesn't care if the drive reported the error, or if the controller reported the error, it just knows
that it couldn't read that block. It goes to recovery, which typically generates the replacement data in a few milliseconds, and tries to write back to the first disk. *That* instantly fails, since the controller is resetting the link and the drive is still in la-la land trying to read the data. MD will tolerate several bad reads before it kicks out a drive, but will immediately kick if a write fails.

Quoted 3 lines

By the time you come to investigate, the drive has completed its timeout, the link has reset, and the otherwise good drive is sitting idle (failed).

I admit I omitted the handling of the error md gets in the case of linux itself timing out the drive, because I don't know how that's handled. For example:

Quoted 7 lines

When you say, "the linux driver stack times out, it passes the error to MD," what error is passed? Is it the same (I think it's 0x40) read error that the drive would have produced, along with affected LBAs? Does the driver know the affected LBA's, maybe by inference? Otherwise md wouldn't know what replacement data to generate. Or is it a different error, neither a read nor write error, that causes md to bounce the drive wholesale?

I haven't examined the code in detail, just watched patches pass on the list. :-) But as I understand it, the error is returned with the request that it belongs to, and the MD does not look at the drive error code itself. So MD know what read it was, for which member devices, but doesn't care if the error came from the drive itself, or the controller, or the driver.

Quoted 5 lines
Quoted 4 lines

Any array running with mismatched timeouts will kick a drive on every unrecoverable read error, where it would likely have just fixed it.

Quoted 8 lines

This is the key phrase I was trying to get at.

Quoted 4 lines

Sadly, many hobbyist arrays are built with desktop drives, and the
timeouts are left mismatched. When that hobbyist later learns
s/he should be scrubbing, the long-overdue scrub is very likely to
produce UREs on multiple drives (BOOM).

Or even if they have been scrubbing all along.

Yes. But in that case, they've probably lost arrays without understanding why.

Quoted 5 lines

If the drive recovers the data inside of 30 seconds, and also doesn't relocated the data to a new sector (? I have no idea when drives do this on their own; I know they will do it on a write failure but I'm unclear when they do it on persistent read "difficulty") the scrub has no means of even being aware there's a problem to fix!

I understand that it varies. But drives generally only reallocate on a write, and only if they are primed to verify the write at that sector by a previous URE at that spot. Those show up in a smartctl report as "Pending".

Quoted 4 lines

Given the craptastic state of affairs that manufacturers disallow a simple setting change to ask the drive to do LESS error correction, the recommendation to buy a different drive that can be so configured, is the best suggestion.

For a while, it was Hitachi Deskstar or enterprise. Western Digital's new "Red" series appears to be an attempt to deal with the backlash.

Quoted 4 lines

Alternative 1 is to change the linux driver timeout to maybe upwards
of two minutes, and then deal with the fall out of that behavior,
which could be worse than a drive being booted out of the array sooner.

Yes. Some servers will time out a connection in 90 seconds if a reply is delayed. To be safe with desktop drives, a timeout of 120 seconds seems to be necessary. I wouldn't be surprised if certain drives needed more, but I have insufficient experience.

Quoted 4 lines

And a very distant alternative 2 is to zero or Secure Erase the drive every so often, in hopes of avoiding bad sectors altogether — is tedious, as well as implies either putting the drive into a degraded state, or cycling a spare drive.

No. This still isn't safe. UREs can happen at any time, and are spec'd to occur at about every 12TB read. Even on a freshly wiped drive. Spares don't help either, as a rebuild onto a spare stresses the rest of the array, and is likely to expose any developing UREs.

Quoted 2 lines

And at the point you're going to buy a spare drive for this fiasco, you might as well just buy drives suited for the purpose.

Options are:

A) Buy Enterprise drives. They have appropriate error timeouts and work properly with MD right out of the box.

B) Buy Desktop drives with SCTERC support. They have inappropriate default timeouts, but can be set to an appropriate value. Udev or boot script assistance is needed to call smartctl to set it. They do *not* work properly with MD out of the box.

C) Suffer with desktop drives without SCTERC support. They cannot be set to appropriate error timeouts. Udev or boot script assistance is needed to set a 120 second driver timeout in sysfs. They do *not* work properly with MD out of the box.

D) Lose your data during spare rebuild after your first URE. (Odds in proportion to array size.)

One last point bears repeating: MD is *not* a backup system, although some people leverage it's features for rotating off-site backup disks. Raid arrays are all about *uptime*. They will not save you from accidental deletion or other operator errors. They will not save you if your office burns down. You need a separate backup system for critical files.

Phil
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

#36 lore raw
Quoted 7 lines · Phil Turmel

I haven't examined the code in detail, just watched patches pass on the list. :-) But as I understand it, the error is returned with the request that it belongs to, and the MD does not look at the drive error code itself. So MD know what read it was, for which member devices, but doesn't care if the error came from the drive itself, or the controller, or the driver.

I think it does, but I don't know diddly about the code.

Only the drive knows what LBA's exhibit read and write errors. The linux driver doesn't. And the linux driver times out after 30 seconds by default, which is an eternity. There isn't just one request pending. There are dozens to hundreds of pending commands, representing possibly tens of thousands of LBAs in the drive's own cache. Once the drive goes into sector recovery, I'm pretty sure SATA drives, unlike SAS, basically go silent. That's probably when the linux timeout counter starts, in the meantime md is still talking to the linux driver making more requests.

This is a huge pile of just requests, not even the data it represents. Some of those requests made it to the drive, some are with the linux driver. I think it's much easier/efficient, when linux block device driver timeout arrives, for the linux driver to just nullify all requests, gives the drive the boot (lalala i can't hear you i don't care if you start talking to me again in 60 seconds), and tells md with a single error that the drive isn't even available. And I'd expect md does the only thing it can do if it gets such an error which is the same as a write error; it flags the device in the array as faulty. I'd be surprised if it tried to reconstruct data at all in such a case, without an explicit read error and LBA reported by the drive.

But I don't know the code, so I'm talking out my ass.

Quoted 12 lines
Quoted 12 lines
Quoted 4 lines

Any array running with mismatched timeouts will kick a drive on every unrecoverable read error, where it would likely have just fixed it.

This is the key phrase I was trying to get at.

Quoted 4 lines

Sadly, many hobbyist arrays are built with desktop drives, and the timeouts are left mismatched. When that hobbyist later learns s/he should be scrubbing, the long-overdue scrub is very likely to produce UREs on multiple drives (BOOM).

Quoted 4 lines
Quoted 1 line

Or even if they have been scrubbing all along.

Yes. But in that case, they've probably lost arrays without understanding why.

Maybe. I don't have data on this. If recovery occurs in less than 30 seconds, they effectively get no indication. They'd have to be looking at ECC errors recorded by SMART. And not all drives record that attribute.

Quoted 10 lines
Quoted 5 lines

If the drive recovers the data inside of 30 seconds, and also doesn't relocated the data to a new sector (? I have no idea when drives do this on their own; I know they will do it on a write failure but I'm unclear when they do it on persistent read "difficulty") the scrub has no means of even being aware there's a problem to fix!

I understand that it varies. But drives generally only reallocate on a write, and only if they are primed to verify the write at that sector by a previous URE at that spot. Those show up in a smartctl report as "Pending".

I'm pretty sure that attribute 197, usually called current pending sector, is only due to unrecoverable read error. Not from a sector that ECC detects transient read error and can correct for. The uncorrectable error, the firmware doesn't want to relocate the data on the sector because it clearly can't get it correct, so it just leaves it there until the sector is written and if on write there's persistent write failure, it gets remapped to a reserve sector. I don't know off hand if there is a read specific remap count, but attribute 5 'reallocated sectors' appears to be read or write remaps. *shrug*

I have several HDDs that have attribute 197, but not attribute 5. And an SSD with only attribute 5, not 197.

Quoted 8 lines
Quoted 5 lines

Given the craptastic state of affairs that manufacturers disallow a simple setting change to ask the drive to do LESS error correction, the recommendation to buy a different drive that can be so configured, is the best suggestion.

For a while, it was Hitachi Deskstar or enterprise. Western Digital's new "Red" series appears to be an attempt to deal with the backlash.

Yeah I know. :-) But I mean all drives could have this. It's a request for LESS, not more. I'm not asking for better ECC, although that would be nice, merely a faster time out as a settable option.

Quoted 10 lines
Quoted 5 lines

And a very distant alternative 2 is to zero or Secure Erase the drive every so often, in hopes of avoiding bad sectors altogether — is tedious, as well as implies either putting the drive into a degraded state, or cycling a spare drive.

No. This still isn't safe. UREs can happen at any time, and are spec'd to occur at about every 12TB read. Even on a freshly wiped drive. Spares don't help either, as a rebuild onto a spare stresses the rest of the array, and is likely to expose any developing UREs.

Technically the spec statistic is "less than" 1 bit in 10^14 for a consumer disk. So it's not that you will get a URE at 12TB, but that you should be able to read at least 11.37TiB without a URE. It's entirely within the tolerance if the mean occurrence happens 2 bits shy of 10^15 bits, or 113TiB. By using "less than" the value is not a mean. It's likely a lot higher than 12TB, or we'd have total mayhem by now. That's only 3 reads of a 4TB drive otherwise. It's bad, but not that bad.

Quoted 14 lines
Quoted 3 lines

And at the point you're going to buy a spare drive for this fiasco, you might as well just buy drives suited for the purpose.

Options are:

A) Buy Enterprise drives. They have appropriate error timeouts and work properly with MD right out of the box.

B) Buy Desktop drives with SCTERC support. They have inappropriate default timeouts, but can be set to an appropriate value. Udev or boot script assistance is needed to call smartctl to set it. They do *not* work properly with MD out of the box.

Quoted 7 lines

C) Suffer with desktop drives without SCTERC support. They cannot be set to appropriate error timeouts. Udev or boot script assistance is needed to set a 120 second driver timeout in sysfs. They do *not* work properly with MD out of the box.

D) Lose your data during spare rebuild after your first URE. (Odds in proportion to array size.)

That's a good summary.

Quoted 7 lines

One last point bears repeating: MD is *not* a backup system, although some people leverage it's features for rotating off-site backup disks. Raid arrays are all about *uptime*. They will not save you from accidental deletion or other operator errors. They will not save you if your office burns down. You need a separate backup system for critical files.

Yeah and that's why I'm sorta leery of this RAID 6 setup in the home. I think that people are reading that the odds of an array failure with RAID 5 are so high that they are better off adding one more drive for dual-parity, and *still* not having a real backup and restore plan. As if the RAID 6 is the faux-backup plan.

Some home NAS's, with BluRay vids, are so big that people just either need to stop such behavior, or get a used LTO 2 or 3 drive for their gargantuous backups.

Chris--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

#9 lore raw
In reply to Thomas Fjellstrom

Could you do me a favor and run the iozone test with the -I switch on so that we can seen the actual speed of the array and not you RAM

/Tommy

Quoted 138 lines · Thomas Fjellstrom
Quoted 18 lines · Stan Hoeppner
Quoted 11 lines · Chris Murphy
Quoted 4 lines · Thomas Fjellstrom

A lot of it will be streaming. Some may end up being random read/writes. The test is just to gauge over all performance of the setup. 600MBs read is far more than I need, but having writes at 1/3 that seems odd to me.

Tell us how many disks there are, and what the chunk size is. It could be too small if you have too few disks which results in a small full stripe size for a video context. If you're using the default, it could be too big and you're getting a lot of RWM. Stan, and others, can better answer this.

Thomas is using a benchmark, and a single one at that, to judge the performance. He's not using his actual workloads. Tuning/tweaking to increase the numbers in a benchmark could be detrimental to actual performance instead of providing a boost. One must be careful.

Quoted 4 lines

Regarding RAID6, it will always have horrible performance compared to non-parity RAID levels and even RAID5, for anything but full stripe aligned writes, which means writing new large files or doing large appends to existing files.

Considering its a rather simple use case, mostly streaming video, and misc file sharing for my home network, an iozone test should be rather telling. Especially the full test, from 4k up to 16mb

                                                            random  random    bkwd   record   stride                                   
              KB  reclen   write rewrite    read    reread    read   write    read  rewrite     read   fwrite frewrite   fread  freread
        33554432       4  243295  221756   628767   624081    1028    4627   16822  7468777    17740   233295   231092  582036   579131
        33554432       8  241134  225728   628264   627015    2027    8879   25977 10030302    19578   228923   233928  591478   584892
        33554432      16  233758  228122   633406   618248    3952   13635   35676 10166457    19968   227599   229698  579267   576850
        33554432      32  232390  219484   625968   625627    7604   18800   44252 10728450    24976   216880   222545  556513   555371
        33554432      64  222936  206166   631659   627823   14112   22837   52259 11243595    30251   196243   192755  498602   494354
        33554432     128  214740  182619   628604   626407   25088   26719   64912 11232068    39867   198638   185078  463505   467853
        33554432     256  202543  185964   626614   624367   44363   34763   73939 10148251    62349   176724   191899  593517   595646
        33554432     512  208081  188584   632188   629547   72617   39145   84876  9660408    89877   182736   172912  610681   608870
        33554432    1024  196429  166125   630785   632413  116793   51904  133342  8687679   121956   168756   175225  620587   616722
        33554432    2048  185399  167484   622180   627606  188571   70789  218009  5357136   370189   171019   166128  637830   637120
        33554432    4096  198340  188695   632693   628225  289971   95211  278098  4836433   611529   161664   170469  665617   655268
        33554432    8192  177919  167524   632030   629077  371602  115228  384030  4934570   618061   161562   176033  708542   709788
        33554432   16384  196639  183744   631478   627518  485622  133467  462861  4890426   644615   175411   179795  725966   734364
Quoted 3 lines

However, everything is relative. This RAID6 may have plenty of random and streaming write/read throughput for Thomas. But a single benchmark isn't going to inform him accurately.

200MB/s may be enough, but the difference between the read and write throughput is a bit unexpected. It's not a weak machine (core i3-2120, dual core 3.2Ghz with HT, 16GB ECC 1333Mhz ram), and this is basically all its going to be doing.

Quoted 7 lines
Quoted 6 lines

You said these are unpartitioned disks, I think. In which case alignment of 4096 byte sectors isn't a factor if these are AF disks.

Unlikely to make up the difference is the scheduler. Parallel fs's like XFS don't perform nearly as well with CFQ, so you should have a kernel parameter elevator=noop.

Quoted 6 lines

If the HBAs have [BB|FB]WC then one should probably use noop as the cache schedules the actual IO to the drives. If the HBAs lack cache, then deadline often provides better performance. Testing of each is required on a system and workload basis. With two identical systems (hardware/RAID/OS) one may perform better with noop, the other with deadline. The determining factor is the applications' IO patterns.

Mostly streaming reads, some long rsync's to copy stuff back and forth, file share duties (downloads etc).

Quoted 7 lines
Quoted 6 lines

Another thing to look at is md/stripe_cache_size which probably needs to be higher for your application.

Another thing to look at is if you're using XFS, what your mount options are. Invariably with an array of this size you need to be mounting with the inode64 option.

Quoted 8 lines

The desired allocator behavior is independent of array size but, once again, dependent on the workloads. inode64 is only needed for large filesystems with lots of files, where 1TB may not be enough for the directory inodes. Or, for mixed metadata/data heavy workloads.

For many workloads including databases, video ingestion, etc, the inode32 allocator is preferred, regardless of array size. This is the linux-raid list so I'll not go into detail of the XFS allocators.

If you have the time and the desire, I'd like to hear about it off list.

Quoted 22 lines
Quoted 11 lines
Quoted 5 lines

The reason I've selected RAID6 to begin with is I've read (on this mailing list, and on some hardware tech sites) that even with SAS drives, the rebuild/resync time on a large array using large disks (2TB+) is long enough that it gives more than enough time for another disk to hit a random read error,

This is true for high density consumer SATA drives. It's not nearly as applicable for low to moderate density nearline SATA which has an order of magnitude lower UER, or for enterprise SAS (and some enterprise SATA) which has yet another order of magnitude lower UER. So it depends on the disks, and the RAID size, and the backup/restore strategy.

Yes, enterprise drives have a much larger spare sector pool.

WRT rebuild time, this is one more reason to use RAID10 or a concat of RAID1s. The rebuild time is low, constant, predictable. For 2TB drives about 5-6 hours at 100% rebuild rate. And rebuild time, for any array type, with gargantuan drives, is yet one more reason not to use the largest drives you can get your hands on. Using 1TB drives will cut that to 2.5-3 hours, and using 500GB drives will cut it down to 1.25-1.5 hours, as all these drives tend to have similar streaming write rates.

Quoted 5 lines

To wit, as a general rule I always build my arrays with the smallest drives I can get away with for the workload at hand. Yes, for a given TB total it increases acquisition cost of drives, HBAs, enclosures, and cables, and power consumption, but it also increases spindle count--thus performance-- while decreasing rebuild times substantially/dramatically.

I'd go raid10 or something if I had the space, but this little 10TB nas (which is the goal, a small, quiet, not too slow, 10TB nas with some kind of redundancy) only fits 7 3.5" HDDs.

Maybe sometime in the future I'll get a big 3 or 4 u case with a crap load of 3.5" HDD bays, but for now, this is what I have (as well as my old array, 7x1TB RAID5+XFS in 4in3 hot swap bays with room for 8 drives, but haven't bothered to expand the old array, and I have the new one almost ready to go).

I don't know if it impacts anything at all, but when burning in these drives after I bought them, I ran the same full iozone test a couple times, and each drive shows 150MB/s read, and similar write times (100-120+?). It impressed me somewhat, to see a mechanical hard drive go that fast. I remember back a few years ago thinking 80MBs was fast for a HDD.

Signature · 6 lines
Thomas Fjellstrom
[email protected]
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html
#37 lore raw
In reply to Chris Murphy
Quoted 11 lines · Chris Murphy
Quoted 7 lines · Phil Turmel

I haven't examined the code in detail, just watched patches pass on the list. :-) But as I understand it, the error is returned with the request that it belongs to, and the MD does not look at the drive error code itself. So MD know what read it was, for which member devices, but doesn't care if the error came from the drive itself, or the controller, or the driver.

I think it does, but I don't know diddly about the code.

If you think about this, you'll realize that the driver *must* keep track of every unique request for the block device. Otherwise, how would MD know what data was read and ready to use? And what data was written so its buffer could be freed? Reads are distinct from writes.

Quoted 6 lines

Only the drive knows what LBA's exhibit read and write errors. The linux driver doesn't. And the linux driver times out after 30 seconds by default, which is an eternity. There isn't just one request pending. There are dozens to hundreds of pending commands, representing possibly tens of thousands of LBAs in the drive's own cache.

But reads are separate from writes, and MD handles them differently. See the "md" man-page under "Recovery".

Quoted 5 lines

Once the drive goes into sector recovery, I'm pretty sure SATA drives, unlike SAS, basically go silent. That's probably when the linux timeout counter starts, in the meantime md is still talking to the linux driver making more requests.

Quoted 12 lines

This is a huge pile of just requests, not even the data it represents. Some of those requests made it to the drive, some are with the linux driver. I think it's much easier/efficient, when linux block device driver timeout arrives, for the linux driver to just nullify all requests, gives the drive the boot (lalala i can't hear you i don't care if you start talking to me again in 60 seconds), and tells md with a single error that the drive isn't even available. And I'd expect md does the only thing it can do if it gets such an error which is the same as a write error; it flags the device in the array as faulty. I'd be surprised if it tried to reconstruct data at all in such a case, without an explicit read error and LBA reported by the drive.

This is just wrong.

Quoted 1 line

But I don't know the code, so I'm talking out my ass.

:-)

[trim /]

Quoted 7 lines
Quoted 2 lines

Yes. But in that case, they've probably lost arrays without understanding why.

Maybe. I don't have data on this. If recovery occurs in less than 30 seconds, they effectively get no indication. They'd have to be looking at ECC errors recorded by SMART. And not all drives record that attribute.

See all the assistance requests on this list where the OP says something to the effect of: "I don't understand! The (failed) drive appears to be OK!"

[trim /]

Quoted 5 lines
Quoted 5 lines
Quoted 4 lines

Given the craptastic state of affairs that manufacturers disallow a simple setting change to ask the drive to do LESS error correction, the recommendation to buy a different drive that can be so configured, is the best suggestion.

Quoted 7 lines
Quoted 3 lines

For a while, it was Hitachi Deskstar or enterprise. Western Digital's new "Red" series appears to be an attempt to deal with the backlash.

Yeah I know. :-) But I mean all drives could have this. It's a request for LESS, not more. I'm not asking for better ECC, although that would be nice, merely a faster time out as a settable option.

You don't seem to understand: The hard drive industry loses revenue when people set up raid arrays with cheap drives, and then have the temerity to return good drives that have been (arguably) misapplied.

Manufacturers have a financial interest in selling enterprise drives instead of desktop drives, and have made desktop drives painful to use in this application. The manufacturers have even redefined "RAID". Supposedly "I" now stands for "Independent" instead of "Inexpensive".

Quoted 11 lines
Quoted 10 lines
Quoted 4 lines

And a very distant alternative 2 is to zero or Secure Erase the drive every so often, in hopes of avoiding bad sectors altogether — is tedious, as well as implies either putting the drive into a degraded state, or cycling a spare drive.

No. This still isn't safe. UREs can happen at any time, and are spec'd to occur at about every 12TB read. Even on a freshly wiped drive. Spares don't help either, as a rebuild onto a spare stresses the rest of the array, and is likely to expose any developing UREs.

Quoted 8 lines

Technically the spec statistic is "less than" 1 bit in 10^14 for a consumer disk. So it's not that you will get a URE at 12TB, but that you should be able to read at least 11.37TiB without a URE. It's entirely within the tolerance if the mean occurrence happens 2 bits shy of 10^15 bits, or 113TiB. By using "less than" the value is not a mean. It's likely a lot higher than 12TB, or we'd have total mayhem by now. That's only 3 reads of a 4TB drive otherwise. It's bad, but not that bad.

That's not really how the statistics work. The spec just means that if you run a typically drive for some long time on some workload you'll average one URE every 10^14 bits. What the actual shape of the distribution is varies through the life of the drive. IIRC, Google's analysis was that the rate spikes early, then forms a gaussian distribution for the bulk of the life, then spikes again as mechanical parts wear out.

Quoted 19 lines
Quoted 19 lines
Quoted 3 lines

And at the point you're going to buy a spare drive for this fiasco, you might as well just buy drives suited for the purpose.

Options are:

A) Buy Enterprise drives. They have appropriate error timeouts and work properly with MD right out of the box.

B) Buy Desktop drives with SCTERC support. They have inappropriate default timeouts, but can be set to an appropriate value. Udev or boot script assistance is needed to call smartctl to set it. They do *not* work properly with MD out of the box.

C) Suffer with desktop drives without SCTERC support. They cannot be set to appropriate error timeouts. Udev or boot script assistance is needed to set a 120 second driver timeout in sysfs. They do *not* work properly with MD out of the box.

Quoted 4 lines
Quoted 2 lines

D) Lose your data during spare rebuild after your first URE. (Odds in proportion to array size.)

That's a good summary.

Yeah. Not enough people hear it though. If I was more than a very light user, I'd be on option A. As it is, option B is best for me.

Quoted 13 lines
Quoted 6 lines

One last point bears repeating: MD is *not* a backup system, although some people leverage it's features for rotating off-site backup disks. Raid arrays are all about *uptime*. They will not save you from accidental deletion or other operator errors. They will not save you if your office burns down. You need a separate backup system for critical files.

Yeah and that's why I'm sorta leery of this RAID 6 setup in the home. I think that people are reading that the odds of an array failure with RAID 5 are so high that they are better off adding one more drive for dual-parity, and *still* not having a real backup and restore plan. As if the RAID 6 is the faux-backup plan.

Quoted 3 lines

Some home NAS's, with BluRay vids, are so big that people just either need to stop such behavior, or get a used LTO 2 or 3 drive for their gargantuous backups.

Well, for me, such material on hard drives *are* the backups. I use "par2" for big backup files, not MD raid. I also skip backups for my Hi-Def MythTV recordings. Just not valuable enough.

Phil
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

#38 lore raw
Quoted 11 lines · Phil Turmel
Quoted 10 lines · Chris Murphy
Quoted 7 lines · Phil Turmel

I haven't examined the code in detail, just watched patches pass on the list. :-) But as I understand it, the error is returned with the request that it belongs to, and the MD does not look at the drive error code itself. So MD know what read it was, for which member devices, but doesn't care if the error came from the drive itself, or the controller, or the driver.

Quoted 4 lines
Quoted 1 line

I think it does, but I don't know diddly about the code.

If you think about this, you'll realize that the driver *must* keep track of every unique request for the block device.

Perhaps not. It looks like it's the SCSI layer that sets the timer on each request. The driver may be doing something comparatively simple. But in any case there is something in between the SATA controller and md that's tracking requests, yes. But presumably md tracks its own requests. It's expecting something back.

Quoted 3 lines

Otherwise, how
would MD know what data was read and ready to use? And what data was written so its buffer could be freed? Reads are distinct from writes.

Yes fine, and I'm suggesting timeouts are distinct from reads and writes. Read and write errors are drive reported errors. I'm suggesting there's some other error from either the linux block device driver (or the SCSI layer) that is not a read error or a write error, when there's a time out.

Quoted 10 lines
Quoted 7 lines

Only the drive knows what LBA's exhibit read and write errors. The linux driver doesn't. And the linux driver times out after 30 seconds by default, which is an eternity. There isn't just one request pending. There are dozens to hundreds of pending commands, representing possibly tens of thousands of LBAs in the drive's own cache.

But reads are separate from writes, and MD handles them differently. See the "md" man-page under "Recovery".

I know that. I'm just suggesting it's not only a read or write error that's possible.

Quoted 19 lines
Quoted 6 lines

Once the drive goes into sector recovery, I'm pretty sure SATA drives, unlike SAS, basically go silent. That's probably when the linux timeout counter starts, in the meantime md is still talking to the linux driver making more requests.

Quoted 12 lines

This is a huge pile of just requests, not even the data it represents. Some of those requests made it to the drive, some are with the linux driver. I think it's much easier/efficient, when linux block device driver timeout arrives, for the linux driver to just nullify all requests, gives the drive the boot (lalala i can't hear you i don't care if you start talking to me again in 60 seconds), and tells md with a single error that the drive isn't even available. And I'd expect md does the only thing it can do if it gets such an error which is the same as a write error; it flags the device in the array as faulty. I'd be surprised if it tried to reconstruct data at all in such a case, without an explicit read error and LBA reported by the drive.

Quoted 1 line

This is just wrong.

Yeah the last sentence is clearly quite wrong: md has to reconstruct the data at some point in such a case, without an explicit read error from the drive. However, I think I largely had the idea right now that I've looked at this after-the-fact.

https://access.redhat.com/knowledge/docs/en-US/Red_Hat_Enterprise_Linux/6/html/Storage_Administration_Guide/task_controlling-scsi-command-timer-onlining-devices.html

I expect that the SCSI layer informs md that the device state is offline. And md in turn marks the drive faulty. And in turn rebuilds all pending and future data chunks for that device from parity (or mirrored copy). No need for a superfluous write attempt for an offline device.

Quoted 10 lines
Quoted 9 lines

Technically the spec statistic is "less than" 1 bit in 10^14 for a consumer disk. So it's not that you will get a URE at 12TB, but that you should be able to read at least 11.37TiB without a URE. It's entirely within the tolerance if the mean occurrence happens 2 bits shy of 10^15 bits, or 113TiB. By using "less than" the value is not a mean. It's likely a lot higher than 12TB, or we'd have total mayhem by now. That's only 3 reads of a 4TB drive otherwise. It's bad, but not that bad.

Quoted 3 lines

That's not really how the statistics work. The spec just means that if you run a typically drive for some long time on some workload you'll average one URE every 10^14 bits.

I don't accept this. "less than" cannot be redefined as "mean/average" in statistics.

And 1 bit does not equal an actual URE either. The drive either reports all 4096 bits for a sector (usually they are good, but they might be corrupted), or you get a URE in which case all 4096 bits are lost. There is no such thing as getting 1 bit of URE with a hard drive when the smallest unit is a sector containing 4096 bits (for non-AF drives). 4096 bits in 10^14 bits is *NOT* the same thing as 1 bit in 10^14 bits. If you lose a sector to URE in 12TBs, that's the same thing as 1 bit in 2.4^10.

And for an AF drive, a URE means you lose 16384 bits. If that happened every 12TB, it would be 1 bit in 6.1^9 bits of loss.

So I don't agree at all with the basic math you've proposed. But then again, I'm just an ape so someone probably ought to double check it.

Quoted 5 lines

What the actual shape of the
distribution is varies through the life of the drive. IIRC, Google's analysis was that the rate spikes early, then forms a gaussian distribution for the bulk of the life, then spikes again as mechanical parts wear out.

That was not a UBER/URE study however. That study was about failures, i.e. whole disks were replaced. They only looked at sector reallocation to see if there was correlation to drive failures/replacements, not if UBER was consistent with manufacturer's stated spec.

Chris Murphy

#10 lore raw
In reply to Tommy Apel Hansen
Quoted 2 lines · Tommy Apel Hansen

Could you do me a favor and run the iozone test with the -I switch on so that we can seen the actual speed of the array and not you RAM

Sure. Though I thought running the test with a file size twice the size of ram would help with that issue.

Quoted 6 lines

/Tommy

Quoted 3 lines · Thomas Fjellstrom
Quoted 2 lines · Stan Hoeppner
Quoted 1 line · Chris Murphy

On Jan 10, 2013, at 3:49 AM, Thomas Fjellstrom <[email protected]>

Quoted 152 lines · wrote:
Quoted 152 lines
Quoted 16 lines
Quoted 10 lines
Quoted 4 lines

A lot of it will be streaming. Some may end up being random read/writes. The test is just to gauge over all performance of the setup. 600MBs read is far more than I need, but having writes at 1/3 that seems odd to me.

Tell us how many disks there are, and what the chunk size is. It could be too small if you have too few disks which results in a small full stripe size for a video context. If you're using the default, it could be too big and you're getting a lot of RWM. Stan, and others, can better answer this.

Thomas is using a benchmark, and a single one at that, to judge the performance. He's not using his actual workloads. Tuning/tweaking to increase the numbers in a benchmark could be detrimental to actual performance instead of providing a boost. One must be careful.

Quoted 4 lines

Regarding RAID6, it will always have horrible performance compared to non-parity RAID levels and even RAID5, for anything but full stripe aligned writes, which means writing new large files or doing large appends to existing files.

Considering its a rather simple use case, mostly streaming video, and misc file sharing for my home network, an iozone test should be rather telling. Especially the full test, from 4k up to 16mb

                                                            random  random   
                                                            bkwd   record  
                                                            stride
              
              KB  reclen   write rewrite    read    reread    read  
              write    read  rewrite     read   fwrite frewrite   fread 
              freread
        
        33554432       4  243295  221756   628767   624081    1028   
        4627   16822  7468777    17740   233295   231092  582036  
        579131 33554432       8  241134  225728   628264   627015   
        2027    8879   25977 10030302    19578   228923   233928  591478
          584892 33554432      16  233758  228122   633406   618248   
        3952   13635   35676 10166457    19968   227599   229698  579267
          576850 33554432      32  232390  219484   625968   625627   
        7604   18800   44252 10728450    24976   216880   222545  556513
          555371 33554432      64  222936  206166   631659   627823  
        14112   22837   52259 11243595    30251   196243   192755 
        498602   494354 33554432     128  214740  182619   628604  
        626407   25088   26719   64912 11232068    39867   198638  
        185078  463505   467853 33554432     256  202543  185964  
        626614   624367   44363   34763   73939 10148251    62349  
        176724   191899  593517   595646 33554432     512  208081 
        188584   632188   629547   72617   39145   84876  9660408   
        89877   182736   172912  610681   608870 33554432    1024 
        196429  166125   630785   632413  116793   51904  133342 
        8687679   121956   168756   175225  620587   616722 33554432   
        2048  185399  167484   622180   627606  188571   70789  218009 
        5357136   370189   171019   166128  637830   637120 33554432   
        4096  198340  188695   632693   628225  289971   95211  278098 
        4836433   611529   161664   170469  665617   655268 33554432   
        8192  177919  167524   632030   629077  371602  115228  384030 
        4934570   618061   161562   176033  708542   709788 33554432  
        16384  196639  183744   631478   627518  485622  133467  462861 
        4890426   644615   175411   179795  725966   734364
Quoted 4 lines

However, everything is relative. This RAID6 may have plenty of random and streaming write/read throughput for Thomas. But a single benchmark isn't going to inform him accurately.

200MB/s may be enough, but the difference between the read and write throughput is a bit unexpected. It's not a weak machine (core i3-2120, dual core 3.2Ghz with HT, 16GB ECC 1333Mhz ram), and this is basically all its going to be doing.

Quoted 7 lines
Quoted 6 lines

You said these are unpartitioned disks, I think. In which case alignment of 4096 byte sectors isn't a factor if these are AF disks.

Unlikely to make up the difference is the scheduler. Parallel fs's like XFS don't perform nearly as well with CFQ, so you should have a kernel parameter elevator=noop.

Quoted 6 lines

If the HBAs have [BB|FB]WC then one should probably use noop as the cache schedules the actual IO to the drives. If the HBAs lack cache, then deadline often provides better performance. Testing of each is required on a system and workload basis. With two identical systems (hardware/RAID/OS) one may perform better with noop, the other with deadline. The determining factor is the applications' IO patterns.

Mostly streaming reads, some long rsync's to copy stuff back and forth, file share duties (downloads etc).

Quoted 7 lines
Quoted 6 lines

Another thing to look at is md/stripe_cache_size which probably needs to be higher for your application.

Another thing to look at is if you're using XFS, what your mount options are. Invariably with an array of this size you need to be mounting with the inode64 option.

Quoted 8 lines

The desired allocator behavior is independent of array size but, once again, dependent on the workloads. inode64 is only needed for large filesystems with lots of files, where 1TB may not be enough for the directory inodes. Or, for mixed metadata/data heavy workloads.

For many workloads including databases, video ingestion, etc, the inode32 allocator is preferred, regardless of array size. This is the linux-raid list so I'll not go into detail of the XFS allocators.

If you have the time and the desire, I'd like to hear about it off list.

Quoted 24 lines
Quoted 6 lines
Quoted 5 lines

The reason I've selected RAID6 to begin with is I've read (on this mailing list, and on some hardware tech sites) that even with SAS drives, the rebuild/resync time on a large array using large disks (2TB+) is long enough that it gives more than enough time for another disk to hit a random read error,

Quoted 6 lines

This is true for high density consumer SATA drives. It's not nearly as applicable for low to moderate density nearline SATA which has an order of magnitude lower UER, or for enterprise SAS (and some enterprise SATA) which has yet another order of magnitude lower UER.
So it depends on the disks, and the RAID size, and the
backup/restore strategy.

Yes, enterprise drives have a much larger spare sector pool.

WRT rebuild time, this is one more reason to use RAID10 or a concat of RAID1s. The rebuild time is low, constant, predictable. For 2TB drives about 5-6 hours at 100% rebuild rate. And rebuild time, for any array type, with gargantuan drives, is yet one more reason not to use the largest drives you can get your hands on. Using 1TB drives will cut that to 2.5-3 hours, and using 500GB drives will cut it down to 1.25-1.5 hours, as all these drives tend to have similar streaming write rates.

Quoted 6 lines

To wit, as a general rule I always build my arrays with the smallest drives I can get away with for the workload at hand. Yes, for a given TB total it increases acquisition cost of drives, HBAs, enclosures, and cables, and power consumption, but it also increases spindle count--thus performance-- while decreasing rebuild times substantially/dramatically.

I'd go raid10 or something if I had the space, but this little 10TB nas (which is the goal, a small, quiet, not too slow, 10TB nas with some kind of redundancy) only fits 7 3.5" HDDs.

Maybe sometime in the future I'll get a big 3 or 4 u case with a crap load of 3.5" HDD bays, but for now, this is what I have (as well as my old array, 7x1TB RAID5+XFS in 4in3 hot swap bays with room for 8 drives, but haven't bothered to expand the old array, and I have the new one almost ready to go).

I don't know if it impacts anything at all, but when burning in these drives after I bought them, I ran the same full iozone test a couple times, and each drive shows 150MB/s read, and similar write times (100-120+?). It impressed me somewhat, to see a mechanical hard drive go that fast. I remember back a few years ago thinking 80MBs was fast for a HDD.

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#46 lore raw
In reply to Chris Murphy
Quoted 1 line · Chris Murphy

On Jan 11, 2013, at 11:51 AM, Thomas Fjellstrom <[email protected]>

Quoted 8 lines · wrote:
Quoted 5 lines · you
Quoted 1 line

OK fair enough, and as asked earlier, what's the chunk size?

Ah, sorry, I missed that bit. I didn't tweak the chunk size, so I have the default 512K.

OK now that the subject has been sufficiently detoured…

Quoted 9 lines

Benchmarking can perhaps help you isolate causes for problems you're having, but you haven't said what problems you're having. You're using benchmarking data to go looking for a problem. This is a GigE network to the NAS? If it's wireless, who cares, all of these array numbers are better than wireless bandwidth and latency. If it's GigE, all of your sequential read write numbers exceed the bandwidth of wired. So what's the problem? You want better random read writes? Rebuild the array with a 32KB or 64KB chunk size, knowing you may take a small hit on the larger sequential read/writes.

I did the "just ignore it" with my last array. This time around I figured it would be a good idea to make sure everything is setup as correctly as is possible given the hardware I have, because once its setup, It's too late to fix any issues found that need changes to the lower level settings.

To me, the write performance shown so far seems quite low, which hints at a problem that could be solved with some config change before I put it into "production". I would like to get it right (as I can), and learn a little in the process.

Quoted 4 lines

Chris Murphy--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

Signature · 6 lines
Thomas Fjellstrom
[email protected]
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html
#11 lore raw
In reply to Thomas Fjellstrom
Quoted 6 lines · Thomas Fjellstrom
Quoted 2 lines · Tommy Apel Hansen

Could you do me a favor and run the iozone test with the -I switch on so that we can seen the actual speed of the array and not you RAM

Sure. Though I thought running the test with a file size twice the size of ram would help with that issue.

This is the initial single 8MB chunk size test

random random
bkwd record stride
KB reclen write rewrite read reread read write
read rewrite read fwrite frewrite fread freread

        33554432    8192  124664  121973   524509   527971  376880  104357  

336083 40088 392683 213941 215453 631122 631617

The full run will take a couple days.

Quoted 31 lines
Quoted 7 lines

/Tommy

Quoted 4 lines · Thomas Fjellstrom
Quoted 3 lines · Stan Hoeppner
Quoted 2 lines · Chris Murphy

On Jan 10, 2013, at 3:49 AM, Thomas Fjellstrom
<[email protected]>

Quoted 22 lines · wrote:
Quoted 22 lines
Quoted 21 lines
Quoted 10 lines
Quoted 4 lines

A lot of it will be streaming. Some may end up being random read/writes. The test is just to gauge over all performance of the setup. 600MBs read is far more than I need, but having writes at 1/3 that seems odd to me.

Tell us how many disks there are, and what the chunk size is. It could be too small if you have too few disks which results in a small full stripe size for a video context. If you're using the default, it could be too big and you're getting a lot of RWM. Stan, and others, can better answer this.

Thomas is using a benchmark, and a single one at that, to judge the performance. He's not using his actual workloads. Tuning/tweaking to increase the numbers in a benchmark could be detrimental to actual performance instead of providing a boost. One must be careful.

Regarding RAID6, it will always have horrible performance compared to non-parity RAID levels and even RAID5, for anything but full stripe aligned writes, which means writing new large files or doing large appends to existing files.

Quoted 5 lines
Quoted 5 lines
Quoted 5 lines

Considering its a rather simple use case, mostly streaming video, and misc file sharing for my home network, an iozone test should be rather telling. Especially the full test, from 4k up to 16mb

random

random

Quoted 1 line
Quoted 1 line
Quoted 1 line

bkwd

record

Quoted 140 lines
Quoted 140 lines
Quoted 140 lines
                                                            stride
              
              KB  reclen   write rewrite    read    reread    read
              write    read  rewrite     read   fwrite frewrite   fread
              freread
        
        33554432       4  243295  221756   628767   624081    1028
        4627   16822  7468777    17740   233295   231092  582036
        579131 33554432       8  241134  225728   628264   627015
        2027    8879   25977 10030302    19578   228923   233928 
        591478
        
          584892 33554432      16  233758  228122   633406   618248
        
        3952   13635   35676 10166457    19968   227599   229698 
        579267
        
          576850 33554432      32  232390  219484   625968   625627
        
        7604   18800   44252 10728450    24976   216880   222545 
        556513
        
          555371 33554432      64  222936  206166   631659   627823
        
        14112   22837   52259 11243595    30251   196243   192755
        498602   494354 33554432     128  214740  182619   628604
        626407   25088   26719   64912 11232068    39867   198638
        185078  463505   467853 33554432     256  202543  185964
        626614   624367   44363   34763   73939 10148251    62349
        176724   191899  593517   595646 33554432     512  208081
        188584   632188   629547   72617   39145   84876  9660408
        89877   182736   172912  610681   608870 33554432    1024
        196429  166125   630785   632413  116793   51904  133342
        8687679   121956   168756   175225  620587   616722 33554432
        2048  185399  167484   622180   627606  188571   70789  218009
        5357136   370189   171019   166128  637830   637120 33554432
        4096  198340  188695   632693   628225  289971   95211  278098
        4836433   611529   161664   170469  665617   655268 33554432
        8192  177919  167524   632030   629077  371602  115228  384030
        4934570   618061   161562   176033  708542   709788 33554432
        16384  196639  183744   631478   627518  485622  133467  462861
        4890426   644615   175411   179795  725966   734364
Quoted 4 lines

However, everything is relative. This RAID6 may have plenty of random and streaming write/read throughput for Thomas. But a single benchmark isn't going to inform him accurately.

200MB/s may be enough, but the difference between the read and write throughput is a bit unexpected. It's not a weak machine (core i3-2120, dual core 3.2Ghz with HT, 16GB ECC 1333Mhz ram), and this is basically all its going to be doing.

Quoted 8 lines
Quoted 7 lines

You said these are unpartitioned disks, I think. In which case alignment of 4096 byte sectors isn't a factor if these are AF disks.

Unlikely to make up the difference is the scheduler. Parallel fs's like XFS don't perform nearly as well with CFQ, so you should have a kernel parameter elevator=noop.

Quoted 6 lines

If the HBAs have [BB|FB]WC then one should probably use noop as the cache schedules the actual IO to the drives. If the HBAs lack cache, then deadline often provides better performance. Testing of each is required on a system and workload basis. With two identical systems (hardware/RAID/OS) one may perform better with noop, the other with deadline. The determining factor is the applications' IO patterns.

Mostly streaming reads, some long rsync's to copy stuff back and forth, file share duties (downloads etc).

Quoted 12 lines
Quoted 6 lines

Another thing to look at is md/stripe_cache_size which probably needs to be higher for your application.

Another thing to look at is if you're using XFS, what your mount options are. Invariably with an array of this size you need to be mounting with the inode64 option.

The desired allocator behavior is independent of array size but, once again, dependent on the workloads. inode64 is only needed for large filesystems with lots of files, where 1TB may not be enough for the directory inodes. Or, for mixed metadata/data heavy workloads.

Quoted 4 lines

For many workloads including databases, video ingestion, etc, the inode32 allocator is preferred, regardless of array size. This is the linux-raid list so I'll not go into detail of the XFS allocators.

If you have the time and the desire, I'd like to hear about it off list.

Quoted 27 lines
Quoted 12 lines
Quoted 5 lines

The reason I've selected RAID6 to begin with is I've read (on this mailing list, and on some hardware tech sites) that even with SAS drives, the rebuild/resync time on a large array using large disks (2TB+) is long enough that it gives more than enough time for another disk to hit a random read error,

This is true for high density consumer SATA drives. It's not nearly as applicable for low to moderate density nearline SATA which has an order of magnitude lower UER, or for enterprise SAS (and some enterprise SATA) which has yet another order of magnitude lower UER.

Quoted 3 lines

So it depends on the disks, and the RAID size, and the

backup/restore strategy.

Yes, enterprise drives have a much larger spare sector pool.

WRT rebuild time, this is one more reason to use RAID10 or a concat of RAID1s. The rebuild time is low, constant, predictable. For 2TB drives about 5-6 hours at 100% rebuild rate. And rebuild time, for any array type, with gargantuan drives, is yet one more reason not to use the largest drives you can get your hands on. Using 1TB drives will cut that to 2.5-3 hours, and using 500GB drives will cut it down to 1.25-1.5 hours, as all these drives tend to have similar streaming write rates.

Quoted 6 lines

To wit, as a general rule I always build my arrays with the smallest drives I can get away with for the workload at hand. Yes, for a given TB total it increases acquisition cost of drives, HBAs, enclosures, and cables, and power consumption, but it also increases spindle count--thus performance-- while decreasing rebuild times substantially/dramatically.

I'd go raid10 or something if I had the space, but this little 10TB nas (which is the goal, a small, quiet, not too slow, 10TB nas with some kind of redundancy) only fits 7 3.5" HDDs.

Maybe sometime in the future I'll get a big 3 or 4 u case with a crap load of 3.5" HDD bays, but for now, this is what I have (as well as my old array, 7x1TB RAID5+XFS in 4in3 hot swap bays with room for 8 drives, but haven't bothered to expand the old array, and I have the new one almost ready to go).

I don't know if it impacts anything at all, but when burning in these drives after I bought them, I ran the same full iozone test a couple times, and each drive shows 150MB/s read, and similar write times (100-120+?). It impressed me somewhat, to see a mechanical hard drive go that fast. I remember back a few years ago thinking 80MBs was fast for a HDD.

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#12 lore raw
Quoted 8 lines · Thomas Fjellstrom

This is the initial single 8MB chunk size test

random random
bkwd record stride
KB reclen write rewrite read reread read write
read rewrite read fwrite frewrite fread freread

        33554432    8192  124664  121973   524509   527971  376880  104357  

336083 40088 392683 213941 215453 631122 631617

Thomas, if you can't paste a data table into an email such that folks can actually read it, try a paste bin. Sending this junk demonstrates a lack of respect for fellow technical users here-- assuming they have or will take time to decipher this. I won't even bother to tackle your lack of trim posting 3 page emails when replying with a single sentence...

It's bad enough that you require so much hand holding for a simple home server array, but then you expect us to assemble puzzles in order to assist you? This is absurd. By doing this you're asking to be treated like a child, asking us to wipe your nose for you.

I'm not being 'hostile' here but REAL. Cowboy up and get it together. Don't retort, don't give excuses. Just take your licks, bite your tongue, and resolve yourself to get this stuff right from now on. It's simple list etiquette, courtesy. If it's worth your time to send an email with an Iozone output table, then it's worth taking a little extra time formatting it so folks can read it.

Signature · 1 line
Stan
#27 lore raw
In reply to Thomas Fjellstrom

Test of my raw SAS2 7K2 disks without bcache
*****************************************************************************
*****************************************************************************
~ # mdadm -C /dev/md0 -l 6 -c 512 -n 7 --assume-clean --run --force /dev/dm-[0,1,2,3,4,5,7]
*****************************************************************************
~ # mdadm -D /dev/md0
/dev/md0:
Raid Level : raid6
Array Size : 9767564800 (9315.08 GiB 10001.99 GB)
Used Dev Size : 1953512960 (1863.02 GiB 2000.40 GB)
Raid Devices : 7
Total Devices : 7
Layout : left-symmetric
Chunk Size : 512K

Number Major Minor RaidDevice State
0 253 0 0 active sync /dev/dm-0
1 253 1 1 active sync /dev/dm-1
2 253 2 2 active sync /dev/dm-2
3 253 3 3 active sync /dev/dm-3
4 253 4 4 active sync /dev/dm-4
5 253 5 5 active sync /dev/dm-5
6 253 7 6 active sync /dev/dm-7
*****************************************************************************
~ # echo 32768 > /sys/block/md0/md/stripe_cache_size
*****************************************************************************
~ # blockdev --getra /dev/dm-0
2048
~ # iozone -I -a -s 1g -y 8192 -q 8192 -i 0 -i 1 -i 2 -I -f /dev/md0
O_DIRECT feature enabled
Auto Mode
File size set to 1048576 KB
Using Minimum Record Size 8192 KB
Using Maximum Record Size 8192 KB
O_DIRECT feature enabled
Command line used: iozone -I -a -s 1g -y 8192 -q 8192 -i 0 -i 1 -i 2 -I -f /dev/md0 Output is in Kbytes/sec
Time Resolution = 0.000001 seconds.
Processor cache size set to 1024 Kbytes.
Processor cache line size set to 32 bytes.
File stride size set to 17 * record size.
random random
KB reclen write rewrite read reread read write
1048576 8192 193370 193976 297343 314465 311949 197962

iozone test complete.
*****************************************************************************
*****************************************************************************
This test should be of more intrest for you as those are the normal blocksizes you'll see hit the disks
*****************************************************************************
~ # iozone -I -a -s 25m -y 4 -q 64 -i 0 -i 1 -i 2 -I -f /dev/md0
O_DIRECT feature enabled
Auto Mode
File size set to 25600 KB
Using Minimum Record Size 4 KB
Using Maximum Record Size 64 KB
O_DIRECT feature enabled
Command line used: iozone -I -a -s 25m -y 4 -q 64 -i 0 -i 1 -i 2 -I -f /dev/md0 Output is in Kbytes/sec
Time Resolution = 0.000001 seconds.
Processor cache size set to 1024 Kbytes.
Processor cache line size set to 32 bytes.
File stride size set to 17 * record size.
random random
KB reclen write rewrite read reread read write
25600 4 864 931 149704 197296 202074 8378
25600 8 1713 1717 204531 254967 245363 15468
25600 16 3522 3389 270464 266586 237274 19848
25600 32 5824 5887 342603 422281 324350 36111
25600 64 10555 10304 382500 367605 318845 56680

iozone test complete.
*****************************************************************************
One more thing you should look for when you do this type of test is that you are properly maxing out you cpu while doing this, my tests were done on a Dual Xeon E5-2609 @ 2.40GHz, that's a total o 8 physical cores, while doing this singlethread iozone test only 1 core was in use and it was maxed out at 12.5% iowait according to iostat, if you run iozone in a multithreaded setup you result will get higher, I was noting just about 48MB/s to every drive in the array while doing the tests above which is about 100MB/s from the max of those drives.
*****************************************************************************
MULTITHREAD TEST BELOW USING XFS
*****************************************************************************
~ # mkfs.xfs -f /dev/md0

data     =                       bsize=4096   blocks=2441887744, imaxpct=5
         =                       sunit=128    swidth=640 blks

*****************************************************************************
~ # mount -t xfs -o noatime,inode64 /dev/md0 /mnt
*****************************************************************************
mnt # iozone -t 20 -s 512m -i 0 -i 1 -i 2 -I -r 8m

Children see throughput for 20 initial writers  =  431515.35 KB/sec
Children see throughput for 20 rewriters        =  349231.38 KB/sec
Children see throughput for 20 readers          =  647558.30 KB/sec
Children see throughput for 20 re-readers       =  643240.44 KB/sec
Children see throughput for 20 random readers   =  642147.36 KB/sec
Children see throughput for 20 random writers   =  325886.66 KB/sec
iozone test complete.
*****************************************************************************
avg-cpu:  %user   %nice %system %iowait  %steal   %idle
           0.00    0.00   21.01   78.61    0.00    0.38

*****************************************************************************
This test brought the drives up around 100MB/s but I ran out of cpu cycles, Now replicate my tests on you system as see what numbers you can come up with, considering your drives are not enterprise sas drives you numbers might be some 10% lower or so.
*****************************************************************************

#13 lore raw
In reply to Stan Hoeppner
Quoted 1 line · you

On 1/14/2013 12:22 PM, Thomas Fjellstrom wrote:

[snip]

Quoted 11 lines

Thomas, if you can't paste a data table into an email such that folks can actually read it, try a paste bin. Sending this junk demonstrates a lack of respect for fellow technical users here-- assuming they have or will take time to decipher this. I won't even bother to tackle your lack of trim posting 3 page emails when replying with a single sentence...

It's bad enough that you require so much hand holding for a simple home server array, but then you expect us to assemble puzzles in order to assist you? This is absurd. By doing this you're asking to be treated like a child, asking us to wipe your nose for you.

Quoted 6 lines

I'm not being 'hostile' here but REAL. Cowboy up and get it together. Don't retort, don't give excuses. Just take your licks, bite your tongue, and resolve yourself to get this stuff right from now on. It's simple list etiquette, courtesy. If it's worth your time to send an email with an Iozone output table, then it's worth taking a little extra time formatting it so folks can read it.

random random bkwd record stride
KB reclen write rewrite read reread read write read rewrite read fwrite frewrite fread freread
33554432 8192 124664 121973 524509 527971 376880 104357 336083 40088 392683 213941 215453 631122 631617

I assume that is to you liking?

As for the simple home server array, if it were so simple, it'd work out of the box with no issues at all.

The implied insults are completely unnecessary. And yes, you are being hostile, whether you choose to admit it or not.

I apologize for not trimming, and not formatting the table properly. I should have waited to post when I wasn't so tired. I tend to forget things when I post too tired.

p.s. I am seriously tempted to play your little flame game, but It's not worth the time.

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#39 lore raw
In reply to Phil Turmel
Quoted 1 line · Phil Turmel

On 01/13/2013 06:20 PM, Chris Murphy wrote:

[snip]

Quoted 13 lines
Quoted 13 lines
Quoted 6 lines

One last point bears repeating: MD is *not* a backup system, although some people leverage it's features for rotating off-site backup disks. Raid arrays are all about *uptime*. They will not save you from accidental deletion or other operator errors. They will not save you if your office burns down. You need a separate backup system for critical files.

Yeah and that's why I'm sorta leery of this RAID 6 setup in the home. I think that people are reading that the odds of an array failure with RAID 5 are so high that they are better off adding one more drive for dual-parity, and *still* not having a real backup and restore plan. As if the RAID 6 is the faux-backup plan.

Quoted 7 lines
Quoted 3 lines

Some home NAS's, with BluRay vids, are so big that people just either need to stop such behavior, or get a used LTO 2 or 3 drive for their gargantuous backups.

Well, for me, such material on hard drives *are* the backups. I use "par2" for big backup files, not MD raid. I also skip backups for my Hi-Def MythTV recordings. Just not valuable enough.

Yeah, I learned a while back to make proper backups. My very important files are backed up from each machine every day to a raid1, which is then synced up to a remote machine. Once the new array is up, the backups will have another location to copy to, as well as the not so important media files will have a backup (some 3TB drives and a few of the old 1TB drives in a linear concat 'array'). I may add another remote backup location in the future, I just haven't decided who to go with.

Quoted 2 lines

Phil
--

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#14 lore raw
In reply to Thomas Fjellstrom
Quoted 5 lines · Thomas Fjellstrom

random random bkwd record stride
KB reclen write rewrite read reread read write read rewrite read fwrite frewrite fread freread
33554432 8192 124664 121973 524509 527971 376880 104357 336083 40088 392683 213941 215453 631122 631617

I assume that is to you liking?

No it's getting hosed for me too, I think it's just too wide for the forum. Pastebin it. And I suggest you post the one that has the variable reclen not just the 8MB result.

And also, now I'm confused because the above reclen8192 result doesn't match with the one you posted from before, so I'm goingn to guess this is the one with -I. My suggestion is that you put into the pastebin the command you used to arrive at the results. Both are important.

Quoted 2 lines

p.s. I am seriously tempted to play your little flame game, but It's not worth the time.

Don't say that or people won't help. If it's your first day at the rodeo taking a bit of a beating and you announce it's not worth it, most people will agree with you and stop playing.

Chris Murphy

#16 lore raw
In reply to Thomas Fjellstrom
Quoted 6 lines · Thomas Fjellstrom

random random bkwd record stride
KB reclen write rewrite read reread read write read rewrite read fwrite frewrite fread freread
33554432 8192 124664 121973 524509 527971 376880 104357 336083 40088 392683 213941 215453 631122 631617

I assume that is to you liking?

Yes, much better. Now, where is the output from the system you're comparing performance against?

Quoted 2 lines

As for the simple home server array, if it were so simple, it'd work out of the box with no issues at all.

It is working. And there are no issues, but for your subjective interpretation of the iozone data, assuming it is not working properly.

This is why benchmarks of this sort are generally only good for comparing one system to another.

Signature · 1 line
Stan
#15 lore raw
In reply to Chris Murphy
Quoted 9 lines · Chris Murphy
Quoted 8 lines · Thomas Fjellstrom

random random
bkwd record
stride

KB reclen write rewrite read reread read write
read rewrite read fwrite frewrite fread
freread

Quoted 8 lines
Quoted 4 lines
       33554432    8192  124664  121973   524509   527971  376880  104357
        336083    40088   392683   213941   215453  631122   631617

I assume that is to you liking?

No it's getting hosed for me too, I think it's just too wide for the forum. Pastebin it. And I suggest you post the one that has the variable reclen not just the 8MB result.

Forum? The email I got back views fine in my email program. Well mostly fine, one of the header lines is offset by one character.

Quoted 4 lines

And also, now I'm confused because the above reclen8192 result doesn't match with the one you posted from before, so I'm goingn to guess this is the one with -I. My suggestion is that you put into the pastebin the command you used to arrive at the results. Both are important.

Yeah, total screw up on my part there. I still had the contents from replying to Tommy with a different test. *sigh* *headdesk*

http://pastebin.com/ffaKiKnN

moose@mrbig:/mnt/mrbig/data/test$ time iozone -a -s 32G -r 8M
                                                            random  random    bkwd   record   stride                                   
      KB  reclen   write rewrite    read    reread    read   write    read  rewrite     read   fwrite frewrite   fread  freread
33554432    8192  208232  210453   628247   630950  370444  163451  382472  4889055   618370   210211   216416  714091   709861
Quoted 6 lines
Quoted 2 lines

p.s. I am seriously tempted to play your little flame game, but It's not worth the time.

Don't say that or people won't help. If it's your first day at the rodeo taking a bit of a beating and you announce it's not worth it, most people will agree with you and stop playing.

I'm a little confused. People won't help if I state that I'm uninterested in a flame war? I've spent way more than enough time engaging in flame wars on the internet.

Quoted 1 line

Chris Murphy

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#17 lore raw
In reply to Stan Hoeppner
Quoted 9 lines · Stan Hoeppner
Quoted 8 lines · Thomas Fjellstrom

random random
bkwd record
stride

KB reclen write rewrite read reread read
write read rewrite read fwrite frewrite fread
freread

Quoted 8 lines
Quoted 5 lines
        33554432    8192  124664  121973   524509   527971  376880 
        104357  336083    40088   392683   213941   215453  631122  
        631617

I assume that is to you liking?

Yes, much better. Now, where is the output from the system you're comparing performance against?

I haven't been comparing it against my other system, as its kind of apples and oranges. My old array, on somewhat similar hardware for the most part, but uses older 1TB drives in RAID5.

Server hw:
Supermicro X9SCM-FO
Xeon E3-1230 3.2Ghz
16GB DDR3 1333mhz ECC
8 port IBM/LSI SAS/SATA HBA

NAS hw:
Intel S1200KP
Core i3-2120 3.3Ghz
16GB DDR3 1333mhz ECC
8 port IBM/LSI SAS/SATA HBA

Not the highest end hardware out there, but it gets the job done. I was actually trying to get less powerful hardware for the NAS, but I really couldn't find much that fit my other requirements (mini-itx server grade hw). Very limited selection of motherboards, most of which take socket 1155 cpus, and the selection of those that also take ECC ram is fairly limited as well.

Quoted 5 lines
Quoted 2 lines

As for the simple home server array, if it were so simple, it'd work out of the box with no issues at all.

It is working. And there are no issues, but for your subjective interpretation of the iozone data, assuming it is not working properly.

It is working. And I can live with it as is, but it does seem like something isn't right. If thats just me jumping to conclusions, well thats fine then. But 600MB/s+ reads vs 200MB/s writes seems a tad off.

Quoted 2 lines

This is why benchmarks of this sort are generally only good for comparing one system to another.

I'm running the same iozone test on the old array, see how it goes. But its currently in use, and getting full (84G free out of 5.5TB), so I'm not positive how well it'll do as compared to if it was a fresh array like the new nas array.

Preliminary results show similar read/write patterns (140MB/s write, 380MB/s read), albeit slower probably due to being well aged, in use, and maybe the drive speeds (the 1TB drives are 20-40MB/s slower than the 2TB drives in a straight read test, I can't remember the write differences).

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#18 lore raw

On 1/14/2013 9:52 PM, Thomas Fjellstrom wrote:
...

Quoted 3 lines

I haven't been comparing it against my other system, as its kind of apples and oranges. My old array, on somewhat similar hardware for the most part, but uses older 1TB drives in RAID5.

...

Quoted 3 lines

It is working. And I can live with it as is, but it does seem like something isn't right. If thats just me jumping to conclusions, well thats fine then. But 600MB/s+ reads vs 200MB/s writes seems a tad off.

It's not off. As myself and others stated previously, this low write performance is typical of RAID6, particularly for unaligned or partial stripe writes--anything that triggers a RMW cycle.

Quoted 4 lines

I'm running the same iozone test on the old array, see how it goes. But its currently in use, and getting full (84G free out of 5.5TB), so I'm not positive how well it'll do as compared to if it was a fresh array like the new nas array.

...

Quoted 4 lines

Preliminary results show similar read/write patterns (140MB/s write, 380MB/s read), albeit slower probably due to being well aged, in use, and maybe the drive speeds (the 1TB drives are 20-40MB/s slower than the 2TB drives in a straight read test, I can't remember the write differences).

Yes, the way in which the old filesystem has aged, and the difference in single drive performance, will both cause lower numbers on the old hardware.

What you're really after, what you want to see, is iozone numbers from a similar system with a 7 drive md/RAID6 array with XFS. Only that will finally convince you, one way or the other, that your array is doing pretty much as well as it can, or not. However, even once you've established this, it still doesn't inform you as to how well the new array will perform with your workloads.

On that note, someone stated you should run iozone using O_DIRECT writes to get more accurate numbers, or more precisely, to eliminate the Linux buffer cache from the equation. Doing this actually makes your testing LESS valid, because your real world use will likely include all buffered IO, and no direct IO.

What you should be concentrating on right now is identifying if any of your workloads make use of fsync. If they do not, or if the majority do not (Samba does not by default IIRC, neither does NFS), then you should be running iozone with fsync disabled. In other words, since you're not comparing two similar systems, you should be tweaking iozone to best mimic your real workloads. Running iozone with buffer cache and with fsync disable should produce higher write numbers, which should be closer to what you will see with your real workloads.

Signature · 1 line
Stan
#19 lore raw

Stan: it is true what you are saying about the cache and real life usage but if you suspect a problem with the array I would suggest testing array rather than the buffer system in linux hence the use if O_DIRECT as that will determine the array performance and not the vmem.

Quoted 53 lines · Stan Hoeppner

On 1/14/2013 9:52 PM, Thomas Fjellstrom wrote:
...

Quoted 3 lines

I haven't been comparing it against my other system, as its kind of apples and oranges. My old array, on somewhat similar hardware for the most part, but uses older 1TB drives in RAID5.

...

Quoted 3 lines

It is working. And I can live with it as is, but it does seem like something isn't right. If thats just me jumping to conclusions, well thats fine then. But 600MB/s+ reads vs 200MB/s writes seems a tad off.

It's not off. As myself and others stated previously, this low write performance is typical of RAID6, particularly for unaligned or partial stripe writes--anything that triggers a RMW cycle.

Quoted 4 lines

I'm running the same iozone test on the old array, see how it goes. But its currently in use, and getting full (84G free out of 5.5TB), so I'm not positive how well it'll do as compared to if it was a fresh array like the new nas array.

...

Quoted 4 lines

Preliminary results show similar read/write patterns (140MB/s write, 380MB/s read), albeit slower probably due to being well aged, in use, and maybe the drive speeds (the 1TB drives are 20-40MB/s slower than the 2TB drives in a straight read test, I can't remember the write differences).

Yes, the way in which the old filesystem has aged, and the difference in single drive performance, will both cause lower numbers on the old hardware.

What you're really after, what you want to see, is iozone numbers from a similar system with a 7 drive md/RAID6 array with XFS. Only that will finally convince you, one way or the other, that your array is doing pretty much as well as it can, or not. However, even once you've established this, it still doesn't inform you as to how well the new array will perform with your workloads.

On that note, someone stated you should run iozone using O_DIRECT writes to get more accurate numbers, or more precisely, to eliminate the Linux buffer cache from the equation. Doing this actually makes your testing LESS valid, because your real world use will likely include all buffered IO, and no direct IO.

What you should be concentrating on right now is identifying if any of your workloads make use of fsync. If they do not, or if the majority do not (Samba does not by default IIRC, neither does NFS), then you should be running iozone with fsync disabled. In other words, since you're not comparing two similar systems, you should be tweaking iozone to best mimic your real workloads. Running iozone with buffer cache and with fsync disable should produce higher write numbers, which should be closer to what you will see with your real workloads.

--
Stan

#21 lore raw
In reply to Stan Hoeppner

If to follow you I can only assume that my server is better at administrating cache than Thomas' server according to these results, this doesn't tell me much about how the subsystem is handeling the io though.

Command line used: iozone -a -s 128g -r 8m Output is in Kbytes/sec
Time Resolution = 0.000001 seconds. Processor cache size set to 1024 Kbytes. Processor cache line size set to 32 bytes. File stride size set to 17 * record size.

random random
KB reclen write ewrite read
reread read write

       134217728    8192  365802  371250   397293   399526  241641  265306

2013/1/15 Stan Hoeppner <[email protected]>:

Quoted 52 lines · Thomas Fjellstrom

...

Quoted 3 lines

I haven't been comparing it against my other system, as its kind of apples and oranges. My old array, on somewhat similar hardware for the most part, but uses older 1TB drives in RAID5.

...

Quoted 3 lines

It is working. And I can live with it as is, but it does seem like something isn't right. If thats just me jumping to conclusions, well thats fine then. But 600MB/s+ reads vs 200MB/s writes seems a tad off.

It's not off. As myself and others stated previously, this low write performance is typical of RAID6, particularly for unaligned or partial stripe writes--anything that triggers a RMW cycle.

Quoted 4 lines

I'm running the same iozone test on the old array, see how it goes. But its currently in use, and getting full (84G free out of 5.5TB), so I'm not positive how well it'll do as compared to if it was a fresh array like the new nas array.

...

Quoted 4 lines

Preliminary results show similar read/write patterns (140MB/s write, 380MB/s read), albeit slower probably due to being well aged, in use, and maybe the drive speeds (the 1TB drives are 20-40MB/s slower than the 2TB drives in a straight read test, I can't remember the write differences).

Yes, the way in which the old filesystem has aged, and the difference in single drive performance, will both cause lower numbers on the old hardware.

What you're really after, what you want to see, is iozone numbers from a similar system with a 7 drive md/RAID6 array with XFS. Only that will finally convince you, one way or the other, that your array is doing pretty much as well as it can, or not. However, even once you've established this, it still doesn't inform you as to how well the new array will perform with your workloads.

On that note, someone stated you should run iozone using O_DIRECT writes to get more accurate numbers, or more precisely, to eliminate the Linux buffer cache from the equation. Doing this actually makes your testing LESS valid, because your real world use will likely include all buffered IO, and no direct IO.

What you should be concentrating on right now is identifying if any of your workloads make use of fsync. If they do not, or if the majority do not (Samba does not by default IIRC, neither does NFS), then you should be running iozone with fsync disabled. In other words, since you're not comparing two similar systems, you should be tweaking iozone to best mimic your real workloads. Running iozone with buffer cache and with fsync disable should produce higher write numbers, which should be closer to what you will see with your real workloads.

--
Stan

#20 lore raw
In reply to Tommy Apel
Quoted 4 lines · Tommy Apel

Stan: it is true what you are saying about the cache and real life usage but if you suspect a problem with the array I would suggest testing array rather than the buffer system in linux hence the use if O_DIRECT as that will determine the array performance and not the vmem.

If you really want to get to testing only the array you must bypass the filesystem as well using something like fio for your testing. Simply bypassing the buffer cache only removes one obstacle of many in the IO path.

But in Thomas case raw IO numbers still don't clear the fog for him because he has no idea what the numbers _should_ be in the first place.
He is assuming, due to lack of knowledge/experience, that write
throughput that is ~1/3rd his read throughput is wrong. It's not. It is expected.

To see this for himself all he need do is blow it away and create a 6 disk RAID10 or layered RAID0 over 3 RAID1 pairs. When he sees the much higher iozone write throughput with only 6 of his disks, only 3 spindles vs 5, then he'll finally understand their is a huge write performance penalty with RAID6.

Signature · 1 line
Stan
#22 lore raw
In reply to Stan Hoeppner
Quoted 9 lines · Stan Hoeppner

On 1/14/2013 9:52 PM, Thomas Fjellstrom wrote:
...

Quoted 3 lines

I haven't been comparing it against my other system, as its kind of apples and oranges. My old array, on somewhat similar hardware for the most part, but uses older 1TB drives in RAID5.

...

Quoted 7 lines
Quoted 3 lines

It is working. And I can live with it as is, but it does seem like something isn't right. If thats just me jumping to conclusions, well thats fine then. But 600MB/s+ reads vs 200MB/s writes seems a tad off.

It's not off. As myself and others stated previously, this low write performance is typical of RAID6, particularly for unaligned or partial stripe writes--anything that triggers a RMW cycle.

That gets me thinking. Maybe try a test with the record test size set to the stripe width, that would hopefully show some more accurate numbers.

If that large of a difference between reads and writes is perfectly normal, I can accept that. I am wondering what kinds of numbers others see, real world wise.

Quoted 17 lines
Quoted 4 lines

I'm running the same iozone test on the old array, see how it goes. But its currently in use, and getting full (84G free out of 5.5TB), so I'm not positive how well it'll do as compared to if it was a fresh array like the new nas array.

...

Quoted 5 lines

Preliminary results show similar read/write patterns (140MB/s write, 380MB/s read), albeit slower probably due to being well aged, in use, and maybe the drive speeds (the 1TB drives are 20-40MB/s slower than the 2TB drives in a straight read test, I can't remember the write differences).

Yes, the way in which the old filesystem has aged, and the difference in single drive performance, will both cause lower numbers on the old hardware.

Quoted 6 lines

What you're really after, what you want to see, is iozone numbers from a similar system with a 7 drive md/RAID6 array with XFS. Only that will finally convince you, one way or the other, that your array is doing pretty much as well as it can, or not. However, even once you've established this, it still doesn't inform you as to how well the new array will perform with your workloads.

In the end, the performance I am getting is more than I currently use day to day. So its not a huge problem I need to solve, rather its something I thought was odd, and wanted to figure out.

Quoted 5 lines

On that note, someone stated you should run iozone using O_DIRECT writes to get more accurate numbers, or more precisely, to eliminate the Linux buffer cache from the equation. Doing this actually makes your testing LESS valid, because your real world use will likely include all buffered IO, and no direct IO.

I didn't think it'd be a very good test of real world performance, but it can't hurt to be thorough. Though I just checked on it, that one run is still going, and it seems like it may be quite a while.

Quoted 8 lines

What you should be concentrating on right now is identifying if any of your workloads make use of fsync. If they do not, or if the majority do not (Samba does not by default IIRC, neither does NFS), then you should be running iozone with fsync disabled. In other words, since you're not comparing two similar systems, you should be tweaking iozone to best mimic your real workloads. Running iozone with buffer cache and with fsync disable should produce higher write numbers, which should be closer to what you will see with your real workloads.

I doubt very much of my workload uses fsync, though if I move some p2p stuff to it /may/ use fsync, to be honest, I'm not sure which (if any) p2p clients use fsync. Or if I particularly care in that case. P2P performance really depends on decent random writes of 512KB-4MB which an array like this isn't exactly going to excel at.

P2P is one reason I was interested in ssd caching (tried playing with bcache, it seemed to cut read speeds down to 200MB/s or something crazy, likely a misconfig on my part, I still have to finish looking into that, the author suggested changing the cache mode).

I've found it incredibly annoying when video playback stutters due to other activity on the array. It used to happen often enough due to the different jobs I had it doing. At one point it held VM images, regular rsnapshot backups, all of my media, and some torrent downloads. Over the past while I've slowly pulled one job after another off the old array till all that its really doing now is storing random downloads, p2p and media file streaming.

Signature · 2 lines
Thomas Fjellstrom
[email protected]
#23 lore raw
Quoted 7 lines · Thomas Fjellstrom
Quoted 6 lines · Stan Hoeppner

On 1/14/2013 9:52 PM, Thomas Fjellstrom wrote:
...

Quoted 3 lines

It is working. And I can live with it as is, but it does seem like something isn't right. If thats just me jumping to conclusions, well thats fine then. But 600MB/s+ reads vs 200MB/s writes seems a tad off.

Quoted 6 lines
Quoted 3 lines

It's not off. As myself and others stated previously, this low write performance is typical of RAID6, particularly for unaligned or partial stripe writes--anything that triggers a RMW cycle.

That gets me thinking. Maybe try a test with the record test size set to the stripe width, that would hopefully show some more accurate numbers.

Your 7-drive RAID-6 with 512K chunk will have a 2.5MB stripe width, or stride, whichever is the correct term, on the basis of 5 data chunks. Even still, a filesystem-level test cannot guarantee to be writing records aligned to the array's data stripes.

If you do another benchmark, try running iostat concurrently, to see how many reads are happening during the write tests.

At the same time, if in the real world you're doing streaming writes of dozens of MB/s, I would expect that write caching would turn a good proportion of the writes into full-stripe writes.

Cheers,

John.

#24 lore raw
Quoted 3 lines · John Robinson

At the same time, if in the real world you're doing streaming writes of dozens of MB/s, I would expect that write caching would turn a good proportion of the writes into full-stripe writes.

The filesystem dictates whether a write is stripe aligned or not, or fills a full stripe. If the filesystem performs multiple partial stripe writes no type nor manner of write caching is going to turn them into a single stripe aligned write. That's not possible.

On that note, a great many people on this list mistakenly configure, optimize, and test their arrays for a magical chunk/stripe size, apparently oblivious to the fact that most writes with most workloads are not going to be full stripe writes, or stripe aligned whatsoever:

1.  Journal writes can be aligned, but usually don't fill a full stripe
2.  Metadata writes to the directory tress are often unaligned
3.  File appends or modify-in-place ops are never aligned

The only instance in which one will always get full stripe writes is when creating and writing a new file whose size is a multiple of the full stripe width. I.e. one must be performing allocation to fill full stripes. Most workloads don't do this.

This is the reason why RAID6 performs so horribly with mixed read/write workloads. Using Thomas' example, while he was doing a streaming read of a media file and simultaneously doing non-aligned writes from a P2P or other application, md is performing a RMW operation during each write, adding substantially to the seek burden on the drives. RAID5/6 use rotating parity, so he also has an extra seek on each of two drives occurring, competing with the read seeks of his streaming app. Consumer 7.2K drives aren't designed to handle this type of random seek load with good performance.

If using RAID10 or RAID0 over RAID1, there is no RMW penalty for partial stripe width writes, and no extra seek burden for the parity writes, as described above for RAID5/6. Thus it doesn't cause the playback stutter as the disks can service the read and write requests without running out of head seek bandwidth as parity arrays do due to RMW and parity block writes.

In summary, with Thomas' old disk system, he would have most likely avoided the playback stutter simply by using a non-parity RAID level.

I'm constantly amazed by the fact that so many people here using parity RAID don't understand the performance impact of these basic parity RAID IO behaviors, and how striping actually works, and the fact that most often they're not writing full stripes, and thus not benefiting from their spindle count.

Signature · 1 line
Stan
#26 lore raw
In reply to Thomas Fjellstrom
Quoted 2 lines · Thomas Fjellstrom

That gets me thinking. Maybe try a test with the record test size set to the stripe width, that would hopefully show some more accurate numbers.

That will give you less accurate numbers, if you're looking for numbers that reflect real world performance. Again, in general, most real world writes are not stripe aligned, and not full width, especially with the insanely large 512KB chunk size.

For all but a few workloads, storage should be designed and optimized assuming most writes will be unaligned or not full width, -not- assuming most will be full stripe writes.

Signature · 1 line
Stan
#25 lore raw
In reply to Stan Hoeppner

On January 16, 2013, Stan Hoeppner wrote:
[snip]

Quoted 9 lines

This is the reason why RAID6 performs so horribly with mixed read/write workloads. Using Thomas' example, while he was doing a streaming read of a media file and simultaneously doing non-aligned writes from a P2P or other application, md is performing a RMW operation during each write, adding substantially to the seek burden on the drives. RAID5/6 use rotating parity, so he also has an extra seek on each of two drives occurring, competing with the read seeks of his streaming app. Consumer 7.2K drives aren't designed to handle this type of random seek load with good performance.

Re-reading through this thread (I have a bit of spare time this weekend), I finally understood what you wrote there. I'm not normally quite this dense, and I appologise. The RMW ops and double seek penalties are really quite harsh.

Quoted 7 lines

If using RAID10 or RAID0 over RAID1, there is no RMW penalty for partial stripe width writes, and no extra seek burden for the parity writes, as described above for RAID5/6. Thus it doesn't cause the playback stutter as the disks can service the read and write requests without running out of head seek bandwidth as parity arrays do due to RMW and parity block writes.

Quoted 8 lines

In summary, with Thomas' old disk system, he would have most likely avoided the playback stutter simply by using a non-parity RAID level.

I'm constantly amazed by the fact that so many people here using parity RAID don't understand the performance impact of these basic parity RAID IO behaviors, and how striping actually works, and the fact that most often they're not writing full stripes, and thus not benefiting from their spindle count.

I actually do/did have a decent understanding of how raid5 works, and why its slower than a lay-person would intuit. The extra seeking, the RMW, and for software raid, the parity calculations. What's happened is I didn't expand that up to how raid6 obviously works, with an extra parity set interleaved with the data. *sigh*

Complete face palm moment.

In the future, if I need more performance than what I'll get out of this setup, I'll move to smaller drives (with ERC, and low URE rates), in raid10. If I had a couple/few extra bays in this box, I'd be very tempted to go raid10 right now.

As I haven't noticed any stuttering with my "old" 5.5TB (7x1TB) array, I somehwat doubt I'll notice any on my new 11TB array (7x2TB, switched to raid5, as with the backup array, I probably don't need/want the extra parity, if two drives do die at the same time, I still have a backup copy of most/all of the data, and can just restore it).

Thank you Stan, Chris, Phil, and Tommy for the help and insight. It was all very helpful.

Signature · 2 lines
Thomas Fjellstrom
[email protected]