Drive replace question
When a drive is being replaced and has lots of errors, does it get kicked before the resync is completed?
I'm performing this action now on a system with kernel 3.14.6. I don't believe the mdadm version makes a difference but it's debian version 3.3-2
Here's the mdstat for that array:
md1 : active raid1 sde[3](R) sdj[2] sdk[1]
1465138448 blocks super 1.0 [2/2] [UU]
[>....................] recovery = 0.0% (419648/1465138448) finish=174.5min speed=139882K/sec
bitmap: 3/11 pages [12KB], 65536KB chunksdj is being replaced by sde. Currently, md1 is not in use.
Signature · 2 lines
Microsoft has beaten Volkswagen's world record. Volkswagen only created 22 million bugs.
Quoted 2 lines · On Fri, 11 Jul 2014 13:13:38 -0400 Wakko Warner <[email protected]> wrote:
When a drive is being replaced and has lots of errors, does it get kicked before the resync is completed?
If it doesn't have a bad block log, then "yes".
If it does, then "no, as long as it doesn't have too many error".
Quoted 3 lines
I'm performing this action now on a system with kernel 3.14.6. I don't believe the mdadm version makes a difference but it's debian version 3.3-2
The version of mdadm that created the array does make a difference. Not all versions create a bad block log. 3.3 and later will create a bad block log.
NeilBrown
Quoted 9 lines
Here's the mdstat for that array:
md1 : active raid1 sde[3](R) sdj[2] sdk[1]1465138448 blocks super 1.0 [2/2] [UU] [>....................] recovery = 0.0% (419648/1465138448) finish=174.5min speed=139882K/sec bitmap: 3/11 pages [12KB], 65536KB chunksdj is being replaced by sde. Currently, md1 is not in use.