Hello guys,

For a patch to this nouveau bug [1] I'm trying to implement the sysfs interface for two properties (linear_min and linear_max) nouveau uses internally to decide when to raise the fan speed. The initial idea was to have them as custom sysfs attributes, but I was advised to try to fit them into the hwmon sysfs interface.

And this is when I hit a little roadblock. If my understanding is correct (and I'm not ashamed to admit it probably isn't) trip points are used to tie together a specific fan speed to a specific temperature. Unfortunately nouveau does not quite work that way: those two properties above mark the temperature the driver uses to decide when to start and stop the *scaling* of the fan speed (from a specific minimum value all the way to 100%).

Now, could I strech the trip point definition above to mean that a trip point specify a *minimum* value for the fan speed at a specific temperature, and that the driver can decide to use an higher speed as needed when the temperature goes above the one specified in the trip point without fear of breaking some convention/userspace tool that expect a constant fan speed? Is this an acceptable/correct usage for the interface?

Thanks,
Gianni

[1] https://bugs.freedesktop.org/show_bug.cgi?id€901

_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors

#1 lore raw
Quoted 16 lines · Gianni Vialetto

Hello guys,

For a patch to this nouveau bug [1] I'm trying to implement the sysfs interface for two properties (linear_min and linear_max) nouveau uses internally to decide when to raise the fan speed. The initial idea was to have them as custom sysfs attributes, but I was advised to try to fit them into the hwmon sysfs interface.

And this is when I hit a little roadblock. If my understanding is correct (and I'm not ashamed to admit it probably isn't) trip points are used to tie together a specific fan speed to a specific temperature. Unfortunately nouveau does not quite work that way: those two properties above mark the temperature the driver uses to decide when to start and stop the *scaling* of the fan speed (from a specific minimum value all the way to 100%).

Quoted 8 lines

Now, could I strech the trip point definition above to mean that a trip point specify a *minimum* value for the fan speed at a specific temperature, and that the driver can decide to use an higher speed as needed when the temperature goes above the one specified in the trip point without fear of breaking some convention/userspace tool that expect a constant fan speed? Is this an acceptable/correct usage for the interface?

For automatic fan control we don't really have a well defined ABI. Part of the problem is that the mechanisms used by various chips are quite different.

Please have a look into Documentation/hwmon/nct6775. It is by far the driver with the most comprehensive fan control mechanisms and attributes. Would any of the attributes or atribute groups in this driver meet your needs ? I could imagine that pwm1_target_temp for the upper temperature limit and pwm1_temp_tolerance for the difference between upper and lower limit might do. Then there are other attributes such as pxm1_start, pwm1_floor, pwm1_step, and pwm1_max which you could use to control pwm values further is that is possible with the driver.

An alternative would be to use two sets of pwm_auto_point attributes, where the first set specifies the start pwm limit and the second specifies the upper temperature and limit. So you would have something like

pwm1_auto_point1_pwm pwm at low temperature
pwm1_auto_point1_temp low temperature

pwm1_auto_point2_pwm pwm at high temperature
pwm1_auto_point2_temp high temperature

After all, there is no requirement that pwm must exactly match the configured value; the above only means that the chip uses those values to calculate the necessary fan speed. In addition to that, you could still have some of the other attributes as needed, such as pwm1_min, pwm1_max, and so on.

Hope this helps,
Guenter

_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors

#3 lore raw
In reply to a message not in the archive

Hi Guenter,

Quoted 4 lines

For automatic fan control we don't really have a well defined ABI. Part of the problem is that the mechanisms used by various chips are quite different.

Quoted 9 lines

Please have a look into Documentation/hwmon/nct6775. It is by far the driver with the most comprehensive fan control mechanisms and attributes. Would any of the attributes or atribute groups in this driver meet your needs ? I could imagine that pwm1_target_temp for the upper temperature limit and pwm1_temp_tolerance for the difference between upper and lower limit might do. Then there are other attributes such as pxm1_start, pwm1_floor, pwm1_step, and pwm1_max which you could use to control pwm values further is that is possible with the driver.

Using pwm1_target_temp and pwm1_temp_tolerance seems a like nice idea, yes. Some of the other attributes are already used and I'm not certain how much I should change at this point.

Quoted 8 lines

An alternative would be to use two sets of pwm_auto_point attributes, where the first set specifies the start pwm limit and the second specifies the upper temperature and limit. So you would have something like

pwm1_auto_point1_pwm pwm at low temperature
pwm1_auto_point1_temp low temperature

Quoted 7 lines

pwm1_auto_point2_pwm pwm at high temperature
pwm1_auto_point2_temp high temperature

After all, there is no requirement that pwm must exactly match the configured value; the above only means that the chip uses those values to calculate the necessary fan speed. In addition to that, you could still have some of the other attributes as needed, such as pwm1_min, pwm1_max, and so on.

This was my initial plan, roughly, but I like the first solution more at this point.

Quoted 2 lines

Hope this helps,
Guenter

Definitely. Thank you.

Regards,
Gianni

_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors

#5 lore raw
In reply to a message not in the archive
Quoted 16 lines · Gianni Vialetto

Hi Guenter,

Quoted 4 lines

For automatic fan control we don't really have a well defined ABI. Part of the problem is that the mechanisms used by various chips are quite different.

Quoted 9 lines

Please have a look into Documentation/hwmon/nct6775. It is by far the driver with the most comprehensive fan control mechanisms and attributes. Would any of the attributes or atribute groups in this driver meet your needs ? I could imagine that pwm1_target_temp for the upper temperature limit and pwm1_temp_tolerance for the difference between upper and lower limit might do. Then there are other attributes such as pxm1_start, pwm1_floor, pwm1_step, and pwm1_max which you could use to control pwm values further is that is possible with the driver.

Quoted 4 lines

Using pwm1_target_temp and pwm1_temp_tolerance seems a like nice idea, yes. Some of the other attributes are already used and I'm not certain how much I should change at this point.

I can not really comment on this. We prefer to retain at least some level of attribute name consistency, but the Nouveau hwmon driver pretty much bypasses hwmon review anyway, so from a practical perspective you can invent as many new attribute names as you like.

Guenter

Quoted 19 lines
Quoted 8 lines

An alternative would be to use two sets of pwm_auto_point attributes, where the first set specifies the start pwm limit and the second specifies the upper temperature and limit. So you would have something like

pwm1_auto_point1_pwm pwm at low temperature
pwm1_auto_point1_temp low temperature

Quoted 7 lines

pwm1_auto_point2_pwm pwm at high temperature
pwm1_auto_point2_temp high temperature

After all, there is no requirement that pwm must exactly match the configured value; the above only means that the chip uses those values to calculate the necessary fan speed. In addition to that, you could still have some of the other attributes as needed, such as pwm1_min, pwm1_max, and so on.

This was my initial plan, roughly, but I like the first solution more at this point.

Quoted 9 lines
Quoted 2 lines

Hope this helps,
Guenter

Definitely. Thank you.

Regards,
Gianni

_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors

#7 lore raw
In reply to a message not in the archive
Quoted 6 lines · Guenter Roeck

I can not really comment on this. We prefer to retain at least some level of attribute name consistency, but the Nouveau hwmon driver pretty much bypasses hwmon review anyway, so from a practical perspective you can invent as many new attribute names as you like.

Guenter

Please do comment on this. I may never have asked for a review but I still tried to stick
to the hwmon sysfs interface documentation.

Martin