Intel L2 Cache Allocation Technology (L2 CAT) Feature enabling
% Intel L2 Cache Allocation Technology (L2 CAT) Feature % Revision 1.0
\clearpage
Hi all,
We plan to bring new PQoS feature called Intel L2 Cache Allocation Technology (L2 CAT) to Xen.
L2 CAT is supported on Atom codename Goldmont and beyond. “Big-core” Xeon does not support L2 CAT in current generations.
This is the initial design of L2 CAT. It might be a little long and detailed, hope it doesn't matter.
Comments and suggestions are welcome :-)
# Basics
---------------- ----------------------------------------------------
Status: **Tech Preview**
Architecture(s): Intel x86
Component(s): Hypervisor, toolstack
Hardware: Atom codename Goldmont and beyond
---------------- ----------------------------------------------------
# Overview
L2 CAT allows an OS or Hypervisor/VMM to control allocation of a CPU's shared L2 cache based on application priority or Class of Service (COS). Each CLOS is configured using capacity bitmasks (CBM) which represent cache capacity and indicate the degree of overlap and isolation between classes. Once L2 CAT is configured, the processor allows access to portions of L2 cache according to the established class of service (COS).
# Technical information
L2 CAT is a member of Intel PQoS features and part of CAT, it shares some base PSR infrastructure in Xen.
## Hardware perspective
L2 CAT defines a new range MSRs to assign different L2 cache access patterns which are known as CBMs (Capacity BitMask), each CBM is associated with a COS.
```
+----------------------------+----------------+
IA32_PQR_ASSOC | MSR (per socket) | Address |
+----+---+-------+ +----------------------------+----------------+
| |COS| | | IA32_L2_QOS_MASK_0 | 0xD10 |
+----+---+-------+ +----------------------------+----------------+
└-------------> | ... | ... |
+----------------------------+----------------+
| IA32_L2_QOS_MASK_n | 0xD10+n (n<64) |
+----------------------------+----------------+
```When context switch happens, the COS of VCPU is written to per-thread MSR IA32_PQR_ASSOC, and then hardware enforces L2 cache allocation according to the corresponding CBM.
## The relationship between L2 CAT and L3 CAT/CDP
L2 CAT is independent of L3 CAT/CDP, which means L2 CAT would be enabled while L3 CAT/CDP is disabled, or L2 CAT and L3 CAT/CDP are all enabled.
L2 CAT uses a new range CBMs from 0xD10 ~ 0xD10+n (n<64), following by the L3 CAT/CDP CBMs, and supports setting different L2 cache accessing patterns from L3 cache.
N.B. L2 CAT and L3 CAT/CDP share the same COS field in the same associate register IA32_PQR_ASSOC, that means one COS corresponds to a pair of L2 CBM and L3 CBM.
In the initial implementation, L2 CAT is shown up on Atom codename Goldmont firstly and there is no platform support both L2 & L3 CAT so far.
## Design Overview
* Core COS/CBM association
When enforcing L2 CAT, all cores of domains have the same default COS (COS0) which associated to the fully open CBM (all ones bitmask) to access all L2 cache. The default COS is used only in hypervisor and is transparent to tool stack and user.
System administrator can change PQoS allocation policy at runtime by tool stack. Since L2 CAT share COS with L3 CAT/CDP, a COS corresponds to a 2-tuple, like [L2 CBM, L3 CBM] with only-CAT enabled, when CDP is enabled, one COS corresponds to a 3-tuple, like [L2 CBM, L3 Code_CBM, L3 Data_CBM]. If neither L3 CAT nor L3 CDP is enabled, things would be easier, one COS corresponds to one L2 CBM.
* VCPU schedule
This part reuses L3 CAT COS infrastructure.
* Multi-sockets
Different sockets may have different L2 CAT capability (e.g. max COS) although it is consistent on the same socket. So the capability of per-socket L2 CAT is specified.
## Implementation Description
* Hypervisor interfaces:
1. Ext: Boot line parameter "psr=cat" now will enable L2 CAT and L3 CAT if hardware supported.
2. New: SYSCTL:
- XEN_SYSCTL_PSR_CAT_get_l2_info: Get L2 CAT information.
3. New: DOMCTL:
- XEN_DOMCTL_PSR_CAT_OP_GET_L2_CBM: Get L2 CBM for a domain.
- XEN_DOMCTL_PSR_CAT_OP_SET_L2_CBM: Set L2 CBM for a domain.
* xl interfaces:
1. Ext: psr-cat-show: Show system/domain L2 CAT information.
=> XEN_SYSCTL_PSR_CAT_get_l2_info /
XEN_DOMCTL_PSR_CAT_OP_GET_L2_CBM 2. Ext: psr-mba-set -l2 domain-id cbm
Set L2 cbm for a domain.
=> XEN_DOMCTL_PSR_CAT_OP_SET_L2_CBM
* Key data structure:
1. Combined PSR bitmasks structure
```
struct psr_mask {
struct l3_cat {
union {
uint64_t cbm;
struct {
uint64_t code;
uint64_t data;
};
};
};
struct l2_cat {
uint64_t cbm;
};
unsigned int ref;
};
```As mentioned above, when more than one PQoS enforcement features are enabled, one COS would correspond several capacity bitmasks. So we combine these bitmasks to one structure, when we setting a new platform shared resource allocation pattern for a guest, it is easy to compare, modify or write the masks by this combined structure.
2. Per-socket PSR allocation features information structure
```
struct psr_cat_lvl_info {
unsigned int cbm_len;
unsigned int cos_max;
};
#define PSR_SOCKET_L3_CAT 1<<0
#define PSR_SOCKET_L3_CDP 1<<1
#define PSR_SOCKET_L2_CAT 1<<2
struct psr_socket_alloc_info {
unsigned long features;
struct psr_cat_lvl_info cat_lvl[4];
struct psr_mask *cos_to_mask;
spinlock_t mask_lock;
};
``` We collect all PSR allocation features information of a socket in this struct psr_socket_alloc_info.
- Member features
features is a bitmap, to indicate which feature is enabled on current socket. We define features bitmap as:
bit 0~1: L3 CAT status, [01] stands for L3 CAT only and [10]
stands for L3 CDP is enalbed.
bit 2: L2 CAT status.
- Member cos_to_mask
cos_to_mask is a array of psr_mask structure which represents the capacity bitmasks of allocation features, and it is indexed by COS.
# User information
* Feature Enabling:
Add "psr=cat" to boot line parameter to enable all supported level CAT features.
* xl interfaces:
1. psr-cat-show [domain-id]:
Show system/domain L2 & L3 CAT information.
2. psr-cat-cbm-set [OPTIONS] domain-id cbm:
New options -l2 and -l3 are added.
-l2: Specify cbm for L2 cache.
-l3: Specify cbm for L3 cache.
If neither -l2 nor -l3 is given, LLC (Last Level Cache) is default behavior. Since there is no CDP support on L2 cache, so if -l2, --code or --data are both given, error message shows.
# References
[Intel® 64 and IA-32 Architectures Software Developer Manuals](http://www.intel.com/content/www/us/en/processors/architectures-software-developer-manuals.html)
# History
------------------------------------------------------------------------
Date Revision Version Notes
---------- -------- -------- -------------------------------------------
2016-05-12 1.0 Xen 4.7 Initial design
---------- -------- -------- -------------------------------------------
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 6 lines
Quoted 1 line
Quoted 1 line · On 12.05.16 at 11:40, <[email protected]> wrote:
% Intel L2 Cache Allocation Technology (L2 CAT) Feature % Revision 1.0
\clearpage
Quoted 7 lines
Hi all,
We plan to bring new PQoS feature called Intel L2 Cache Allocation Technology (L2 CAT) to Xen.
L2 CAT is supported on Atom codename Goldmont and beyond. “Big-core” Xeon does not support L2 CAT in current generations.
Looks mostly like a direct (and hence reasonable) extension of what we have for L3 right now. One immediate question I have is whether tying this to per-socket information is a good idea. As soon as Xeon-s would also gain such functionality, things would (aiui) need to become per-core (as L2 is per core there iirc).
The other question is whether with Xen we care enough about Atoms to add code that's of use only there.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 10 lines · He Chen
% Intel L2 Cache Allocation Technology (L2 CAT) Feature % Revision 1.0
\clearpage
Hi all,
We plan to bring new PQoS feature called Intel L2 Cache Allocation Technology (L2 CAT) to Xen.
Quoted 7 lines
L2 CAT is supported on Atom codename Goldmont and beyond. “Big-core” Xeon does not support L2 CAT in current generations.
This is the initial design of L2 CAT. It might be a little long and detailed, hope it doesn't matter.
Comments and suggestions are welcome :-)
First of all, thankyou very much for choosing to do the doc like this. It is nice to see this format starting to get used.
Quoted 4 lines
## The relationship between L2 CAT and L3 CAT/CDP
L2 CAT is independent of L3 CAT/CDP, which means L2 CAT would be enabled while L3 CAT/CDP is disabled, or L2 CAT and L3 CAT/CDP are all enabled.
The wording here is a little odd, given that no hardware currently supports both L2 and L3.
It might be easier to say:
L2 CAT is independent of L3 CAT/CDP, and both may be enabled at the same time.
Otherwise, everything else looks great.
~Andrew
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 11 lines · Jan Beulich
Quoted 11 lines
Quoted 1 line
Quoted 1 line · On 12.05.16 at 11:40, <[email protected]> wrote:
% Intel L2 Cache Allocation Technology (L2 CAT) Feature % Revision 1.0
\clearpage
Hi all,
We plan to bring new PQoS feature called Intel L2 Cache Allocation Technology (L2 CAT) to Xen.
Quoted 9 lines
Quoted 2 lines
L2 CAT is supported on Atom codename Goldmont and beyond. “Big-core” Xeon does not support L2 CAT in current generations.
Looks mostly like a direct (and hence reasonable) extension of what we have for L3 right now. One immediate question I have is whether tying this to per-socket information is a good idea. As soon as Xeon-s would also gain such functionality, things would (aiui) need to become per-core (as L2 is per core there iirc).
L2 Cache capability keeps the same through all cores in a socket, so we make it per-socket to balance code complexity and accessibility.
I am not a expert in scheduler, do you mean in some cases, a domain would apply different L2 cache access pattern when it is scheduled on different cores even though the cores are in the same socket?
Quoted 3 lines
The other question is whether with Xen we care enough about Atoms to add code that's of use only there.
L2 CAT is a platform independent feature although it firstly shows in Atoms and I believe that it will appear in other platform soon.
Thanks,
-He
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 16 lines
Quoted 1 line
Quoted 1 line · On 13.05.16 at 08:26, <[email protected]> wrote:
Quoted 4 lines · Jan Beulich
Quoted 4 lines
Quoted 1 line
Quoted 1 line · On 12.05.16 at 11:40, <[email protected]> wrote:
We plan to bring new PQoS feature called Intel L2 Cache Allocation Technology (L2 CAT) to Xen.
Quoted 9 lines
Quoted 2 lines
L2 CAT is supported on Atom codename Goldmont and beyond. “Big-core” Xeon does not support L2 CAT in current generations.
Looks mostly like a direct (and hence reasonable) extension of what we have for L3 right now. One immediate question I have is whether tying this to per-socket information is a good idea. As soon as Xeon-s would also gain such functionality, things would (aiui) need to become per-core (as L2 is per core there iirc).
Quoted 6 lines
L2 Cache capability keeps the same through all cores in a socket, so we make it per-socket to balance code complexity and accessibility.
I am not a expert in scheduler, do you mean in some cases, a domain would apply different L2 cache access pattern when it is scheduled on different cores even though the cores are in the same socket?
No, I mean different domains may be running on different cores, and hence different policies may be needed to accommodate them all.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 17 lines · Jan Beulich
Quoted 17 lines
Quoted 1 line
Quoted 1 line · On 13.05.16 at 08:26, <[email protected]> wrote:
Quoted 4 lines · Jan Beulich
Quoted 4 lines
Quoted 1 line
Quoted 1 line · On 12.05.16 at 11:40, <[email protected]> wrote:
We plan to bring new PQoS feature called Intel L2 Cache Allocation Technology (L2 CAT) to Xen.
Quoted 8 lines
Quoted 2 lines
L2 CAT is supported on Atom codename Goldmont and beyond. “Big-core” Xeon does not support L2 CAT in current generations.
Looks mostly like a direct (and hence reasonable) extension of what we have for L3 right now. One immediate question I have is whether tying this to per-socket information is a good idea. As soon as Xeon-s would also gain such functionality, things would (aiui) need to become per-core (as L2 is per core there iirc).
L2 Cache capability keeps the same through all cores in a socket, so we make it per-socket to balance code complexity and accessibility.
Quoted 6 lines
Quoted 3 lines
I am not a expert in scheduler, do you mean in some cases, a domain would apply different L2 cache access pattern when it is scheduled on different cores even though the cores are in the same socket?
No, I mean different domains may be running on different cores, and hence different policies may be needed to accommodate them all.
From the description, it sounds like L2 behaves almost exactly like L3. There is one set of capacity bitmaps which apply to all L2 caches in the socket, and the specific capacity bitmap in effect is specified by PSR_ASSOC CLOS, which is context switched with the vcpu.
~Andrew
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 22 lines
Quoted 1 line
Quoted 1 line · On 13.05.16 at 09:43, <[email protected]> wrote:
Quoted 20 lines · Jan Beulich
Quoted 20 lines
Quoted 1 line
Quoted 1 line · On 13.05.16 at 08:26, <[email protected]> wrote:
Quoted 4 lines · Jan Beulich
Quoted 4 lines
Quoted 1 line
Quoted 1 line · On 12.05.16 at 11:40, <[email protected]> wrote:
We plan to bring new PQoS feature called Intel L2 Cache Allocation Technology (L2 CAT) to Xen.
Quoted 8 lines
Quoted 2 lines
L2 CAT is supported on Atom codename Goldmont and beyond. “Big-core” Xeon does not support L2 CAT in current generations.
Looks mostly like a direct (and hence reasonable) extension of what we have for L3 right now. One immediate question I have is whether tying this to per-socket information is a good idea. As soon as Xeon-s would also gain such functionality, things would (aiui) need to become per-core (as L2 is per core there iirc).
L2 Cache capability keeps the same through all cores in a socket, so we make it per-socket to balance code complexity and accessibility.
I am not a expert in scheduler, do you mean in some cases, a domain would apply different L2 cache access pattern when it is scheduled on different cores even though the cores are in the same socket?
Quoted 8 lines
Quoted 3 lines
No, I mean different domains may be running on different cores, and hence different policies may be needed to accommodate them all.
From the description, it sounds like L2 behaves almost exactly like L3. There is one set of capacity bitmaps which apply to all L2 caches in the socket, and the specific capacity bitmap in effect is specified by
PSR_ASSOCCLOS, which is context switched with the vcpu.
Well, I suppose the description is implying per-socket L2s. For per- core L2s I'd expect the MSRs to also become per-core.
But anyway, L2 or L3 - I can't see how this context switching would DTRT when there are vCPU-s of different domains on the same socket (or core, if L2s and MSRs were per-core): The one getting scheduled later onto a socket (core) would simply overwrite what got written for the one which had been scheduled earlier.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 29 lines · Jan Beulich
Quoted 22 lines
Quoted 1 line
Quoted 1 line · On 13.05.16 at 09:43, <[email protected]> wrote:
Quoted 20 lines · Jan Beulich
Quoted 20 lines
Quoted 1 line
Quoted 1 line · On 13.05.16 at 08:26, <[email protected]> wrote:
Quoted 4 lines · Jan Beulich
Quoted 4 lines
Quoted 1 line
Quoted 1 line · On 12.05.16 at 11:40, <[email protected]> wrote:
We plan to bring new PQoS feature called Intel L2 Cache Allocation Technology (L2 CAT) to Xen.
Quoted 8 lines
Quoted 2 lines
L2 CAT is supported on Atom codename Goldmont and beyond. “Big-core” Xeon does not support L2 CAT in current generations.
Looks mostly like a direct (and hence reasonable) extension of what we have for L3 right now. One immediate question I have is whether tying this to per-socket information is a good idea. As soon as Xeon-s would also gain such functionality, things would (aiui) need to become per-core (as L2 is per core there iirc).
L2 Cache capability keeps the same through all cores in a socket, so we make it per-socket to balance code complexity and accessibility.
I am not a expert in scheduler, do you mean in some cases, a domain would apply different L2 cache access pattern when it is scheduled on different cores even though the cores are in the same socket?
Quoted 7 lines
Quoted 3 lines
No, I mean different domains may be running on different cores, and hence different policies may be needed to accommodate them all.
From the description, it sounds like L2 behaves almost exactly like L3. There is one set of capacity bitmaps which apply to all L2 caches in the socket, and the specific capacity bitmap in effect is specified by
PSR_ASSOCCLOS, which is context switched with the vcpu.
Quoted 8 lines
Well, I suppose the description is implying per-socket L2s. For per- core L2s I'd expect the MSRs to also become per-core.
But anyway, L2 or L3 - I can't see how this context switching would DTRT when there are vCPU-s of different domains on the same socket (or core, if L2s and MSRs were per-core): The one getting scheduled later onto a socket (core) would simply overwrite what got written for the one which had been scheduled earlier.
PSR_ASSOC is a per-thread MSR which selects the CLOS to use. CLOS is currently managed per-domain in Xen, and context switched with vcpu.
Xen programs different capacity bitmaps into IA32_L2_QOS_MASK_0 ... IA32_L2_QOS_MASK_n, and the CLOS selects which bitmap is enforced.
~Andrew
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 10 lines · Andrew Cooper
Quoted 6 lines · Jan Beulich
But anyway, L2 or L3 - I can't see how this context switching would DTRT when there are vCPU-s of different domains on the same socket (or core, if L2s and MSRs were per-core): The one getting scheduled later onto a socket (core) would simply overwrite what got written for the one which had been scheduled earlier.
PSR_ASSOCis a per-thread MSR which selects the CLOS to use. CLOS is currently managed per-domain in Xen, and context switched with vcpu.
Yep, exactly. I did look a bit into this for CMT (so, not L3 CAT, but it's not that different).
Doing things on a per-vcpu basis could be interesting, and that's even more the case if we get to do L2 stuff, but there are two few RMIDs available for such a configuration to be really useful.
Quoted 3 lines
Xen programs different capacity bitmaps into
IA32_L2_QOS_MASK_0...IA32_L2_QOS_MASK_n, and the CLOS selects which bitmap is enforced.
So, basically, just to figure out if I understood (i.e., this is for He Chen).
If we have a 2 sockets, with socket 0 containing cores 0,1,2,3 and socket 1 containing cores 4,5,6,7, it will be possible to specify two different "L2 reservation values" (in the form of CBMs, of course), for a domain:
- one would be how much L2 cache the domain will be able to use (say
X) when running on socket 1, which means on cores 0,1,2 or 3
- another would be how much L2 cache the domain will be able to (say, Y use when running on socket 2, which means on cores 4,5,6, or 7
Which in turn means, in case L2 is per core, the domain will get X of core 0's L2, X of core 1's L2, X of core 2's L2 and X of core 3's L2. On socket 1, it will get Y of core 4' L2, Y of core 5's L2 cache etc. etc.
And so, in summary what we would not be able to specify is a different value for the L2 reservations of, for instance, core 1 and core 3 (i.e., of cores that are part of the same socket).
Does this summary make sense?
Thanks and Regards,
Dario
Signature · 4 lines
<<This happens because I choose it to happen!>> (Raistlin Majere) ----------------------------------------------------------------- Dario Faggioli, Ph.D, http://about.me/dario.faggioli Senior Software Engineer, Citrix Systems R&D Ltd., Cambridge (UK)
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 38 lines · Dario Faggioli
Quoted 10 lines · Andrew Cooper
Quoted 6 lines · Jan Beulich
But anyway, L2 or L3 - I can't see how this context switching would DTRT when there are vCPU-s of different domains on the same socket (or core, if L2s and MSRs were per-core): The one getting scheduled later onto a socket (core) would simply overwrite what got written for the one which had been scheduled earlier.
PSR_ASSOCis a per-thread MSR which selects the CLOS to use. CLOS is currently managed per-domain in Xen, and context switched with vcpu.Yep, exactly. I did look a bit into this for CMT (so, not L3 CAT, but it's not that different).
Doing things on a per-vcpu basis could be interesting, and that's even more the case if we get to do L2 stuff, but there are two few RMIDs available for such a configuration to be really useful.
Quoted 3 lines
Xen programs different capacity bitmaps into
IA32_L2_QOS_MASK_0...IA32_L2_QOS_MASK_n, and the CLOS selects which bitmap is enforced.So, basically, just to figure out if I understood (i.e., this is for He Chen).
If we have a 2 sockets, with socket 0 containing cores 0,1,2,3 and socket 1 containing cores 4,5,6,7, it will be possible to specify two different "L2 reservation values" (in the form of CBMs, of course), for a domain:
- one would be how much L2 cache the domain will be able to use (say
X) when running on socket 1, which means on cores 0,1,2 or 3
- another would be how much L2 cache the domain will be able to (say, Y use when running on socket 2, which means on cores 4,5,6, or 7Which in turn means, in case L2 is per core, the domain will get X of core 0's L2, X of core 1's L2, X of core 2's L2 and X of core 3's L2. On socket 1, it will get Y of core 4' L2, Y of core 5's L2 cache etc. etc.
Quoted 5 lines
And so, in summary what we would not be able to specify is a different value for the L2 reservations of, for instance, core 1 and core 3 (i.e., of cores that are part of the same socket).
Does this summary make sense?
Yes, great instance and that is exactly how L3 CAT work now. Let's see the source to make it clear:
```
void psr_ctxt_switch_to(struct domain *d)
{
...
if ( psra->cos_mask )
psr_assoc_cos(®, d->arch.psr_cos_ids ?
d->arch.psr_cos_ids[cpu_to_socket(smp_processor_id())] :
0, psra->cos_mask);
...
}
```psr_cos_ids is indexed by socket_id which leads to the per-socket cache enforcement.
As Andrew said, CLOS is currently managed per-domain in Xen and it works well so far. So in initial design, I am inclined to continue this behavior (per-socket) to L2 CAT to keep the consistency between L2 and L3 CAT. Any thoughts?
Thanks,
-He
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 7 lines · He Chen
As Andrew said, CLOS is currently managed per-domain in Xen and it works
well so far. So in initial design, I am inclined to continue this behavior (per-socket) to L2 CAT to keep the consistency between L2 and
L3 CAT. Any thoughts?
FWIW, I think this is fine. If at some point we'll want something different, we can always extend.
Perhaps, let's keep this (the fact that we may want to make things more fine grained) in mind when designing the interface.
Regards,
Dario
Signature · 4 lines
<<This happens because I choose it to happen!>> (Raistlin Majere) ----------------------------------------------------------------- Dario Faggioli, Ph.D, http://about.me/dario.faggioli Senior Software Engineer, Citrix Systems R&D Ltd., Cambridge (UK)
_______________________________________________
Xen-devel mailing list
[email protected]