multipath-tools: preload also scsi_dh_hp_sw before run multipathd
PATCH 1/1 multipath-tools: preload also scsi_dh_hp_sw before run multipathd
--- multipathd/multipathd.service | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
multipathd/multipathd.service +1 -1
@@ -11,7 +11,7 @@ Conflicts=shutdown.target Type=notify NotifyAccess=main LimitCORE=infinity -ExecStartPre=/sbin/modprobe -a scsi_dh_alua scsi_dh_emc scsi_dh_rdac dm-multipath +ExecStartPre=/sbin/modprobe -a scsi_dh_alua scsi_dh_emc scsi_dh_hp_sw scsi_dh_rdac dm-multipath ExecStart=/sbin/multipathd -d -s ExecReload=/sbin/multipathd reconfigure
Signature · 1 line
2.10.1
Quoted 14 lines · Xose Vazquez Perez
Cc Hannes Reinecke <[email protected]>Cc Christophe Varoqui <[email protected]>Cc device-mapper development <[email protected]>Signed-off-by Xose Vazquez Perez <[email protected]>--- multipathd/multipathd.service | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)multipathd/multipathd.service +0
-0
multipathd/multipathd.service Conflicts=shutdown.target · line 17
Quoted 8 lines
multipathd/multipathd.service +1
-1@@ -11,7 +11,7 @@ Conflicts=shutdown.target Type=notify NotifyAccess=main LimitCORE=infinity -ExecStartPre=/sbin/modprobe -a scsi_dh_alua scsi_dh_emc scsi_dh_rdac dm-multipath +ExecStartPre=/sbin/modprobe -a scsi_dh_alua scsi_dh_emc scsi_dh_hp_sw scsi_dh_rdac dm-multipath ExecStart=/sbin/multipathd -d -s ExecReload=/sbin/multipathd reconfigure
Well.
If you can point me to a single user of an MSA1500 I'm happy to include it. If you don't know what an MSA1500 is nor what hp_sw does it's probably not a good idea to have it.
Cheers,
Hannes
Signature · 4 lines
Dr. Hannes Reinecke zSeries & Storage [email protected] +49 911 74053 688 SUSE LINUX Products GmbH, Maxfeldstr. 5, 90409 Nürnberg GF: J. Hawn, J. Guild, F. Imendörffer, HRB 16746 (AG Nürnberg)
Quoted 9 lines · Hannes Reinecke
Quoted 8 lines · Xose Vazquez Perez
Cc Hannes Reinecke <[email protected]>Cc Christophe Varoqui <[email protected]>Cc device-mapper development <[email protected]>Signed-off-by Xose Vazquez Perez <[email protected]>--- multipathd/multipathd.service | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
Quoted 15 lines
multipathd/multipathd.service Conflicts=shutdown.target · line 17
Quoted 13 lines
multipathd/multipathd.service +1
-1@@ -11,7 +11,7 @@ Conflicts=shutdown.target Type=notify NotifyAccess=main LimitCORE=infinity -ExecStartPre=/sbin/modprobe -a scsi_dh_alua scsi_dh_emc scsi_dh_rdac dm-multipath +ExecStartPre=/sbin/modprobe -a scsi_dh_alua scsi_dh_emc scsi_dh_hp_sw scsi_dh_rdac dm-multipath ExecStart=/sbin/multipathd -d -s ExecReload=/sbin/multipathd reconfigureIf you can point me to a single user of an MSA1500 I'm happy to include it. If you don't know what an MSA1500 is nor what
hp_swdoes it's probably not a good idea to have it.
Why?
scsi_dh_hp_sw is used also for dec/compaq ESA12000 and RA8000 arrays with HSG80 controller. And in HP MSA 1000/1500 and EVA 3000/5000, with old firmware.
Thank you.
Quoted 27 lines · Xose Vazquez Perez
Quoted 9 lines · Hannes Reinecke
Quoted 8 lines · Xose Vazquez Perez
Cc Hannes Reinecke <[email protected]>Cc Christophe Varoqui <[email protected]>Cc device-mapper development <[email protected]>Signed-off-by Xose Vazquez Perez <[email protected]>--- multipathd/multipathd.service | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)Quoted 15 lines
multipathd/multipathd.service Conflicts=shutdown.target · line 17
Quoted 13 lines
multipathd/multipathd.service +1
-1@@ -11,7 +11,7 @@ Conflicts=shutdown.target Type=notify NotifyAccess=main LimitCORE=infinity -ExecStartPre=/sbin/modprobe -a scsi_dh_alua scsi_dh_emc scsi_dh_rdac dm-multipath +ExecStartPre=/sbin/modprobe -a scsi_dh_alua scsi_dh_emc scsi_dh_hp_sw scsi_dh_rdac dm-multipath ExecStart=/sbin/multipathd -d -s ExecReload=/sbin/multipathd reconfigureIf you can point me to a single user of an MSA1500 I'm happy to include it. If you don't know what an MSA1500 is nor what
hp_swdoes it's probably not a good idea to have it.
Quoted 5 lines
Why?
scsi_dh_hp_swis used also for dec/compaq ESA12000 and RA8000 arrays with HSG80 controller. And in HP MSA 1000/1500 and EVA 3000/5000, with old firmware.
EVA? I sincerely doubt that.
Do you really have an example for that?
Anyway.
Point here is, these are _really_ old SCSI parallel arrays. And the failover command is _really_ stupid (just send a START STOP UNIT to the passive path). As this has a tendency to interfere with normal operation I prefer to _NOT_ have it loaded per default; in fact, I'm on the verge of removing it altogether.
Cheers,
Hannes
Signature · 9 lines
Dr. Hannes Reinecke zSeries & Storage [email protected] +49 911 74053 688 SUSE LINUX Products GmbH, Maxfeldstr. 5, 90409 Nürnberg GF: J. Hawn, J. Guild, F. Imendörffer, HRB 16746 (AG Nürnberg) -- dm-devel mailing list [email protected] https://www.redhat.com/mailman/listinfo/dm-devel
Quoted 7 lines · Hannes Reinecke
Quoted 3 lines · Xose Vazquez Perez
scsi_dh_hp_swis used also for dec/compaq ESA12000 and RA8000 arrays with HSG80 controller. And in HP MSA 1000/1500 and EVA 3000/5000, with old firmware.EVA? I sincerely doubt that.
Do you really have an example for that?
{
/* MSA 1000/1500 and EVA 3000/5000, with old firmware */
.vendor = "(COMPAQ|HP)",
.product = "(MSA|HSV)1[01]0",
.hwhandler = "1 hp_sw",
.pgpolicy = GROUP_BY_PRIO,
.no_path_retry = 12,
.checker_name = HP_SW,
.prio_name = PRIO_HP_SW,
},HSV100 is HP StorageWorks Enterprise Virtual Array 3000:
http://h18000.www1.hp.com/products/quickspecs/archives_Division/11619_div_v9/11619_div.PDF
HSV110 is HP StorageWorks Enterprise Virtual Array 5000:
https://www.hpe.com/h20195/v2/GetPDF.aspx/c04282828.pdf