board: ge: bx50v3: fix AR8033 reset timing issue
PATCH v2 1/2 board: ge: bx50v3: fix AR8033 reset timing issue
Add the delay (10ms) to ensure the clock is stable and to meet the clock-to-reset(1ms) requirement recommended in the AR8033 datasheet
---
Changes from v1
- Fix the missing Signed-off-by issue
board/ge/bx50v3/bx50v3.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-)
board/ge/bx50v3/bx50v3.c +2 -1
@@ -103,8 +103,9 @@ static void setup_iomux_enet(void)/* Reset AR8033 PHY */ gpio_direction_output (IMX_GPIO_NR (1 ,28 ),0 ); -udelay (500 ); +mdelay (10 );gpio_set_value (IMX_GPIO_NR (1 ,28 ),1 ); +mdelay (1 ); }static iomux_v3_cfg_t const usdhc2_pads[] = {
Signature · 1 line
2.11.0
PATCH v2 2/2 board: ge: bx50v3: apply the proper register setting to fix the voltage peak issue
Apply the proper setting for the reserved bits in SetDes Test and System Mode Control register to avoid the voltage peak issue while we do the IEEE PHY comformance test
---
Changes from v1
- New commit message
board/ge/bx50v3/bx50v3.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-)
board/ge/bx50v3/bx50v3.c +2 -1
@@ -307,7 +307,8 @@ static int mx6_rgmii_rework(struct phy_device *phydev)/* set debug port address: SerDes Test and System Mode Control */ phy_write (phydev,MDIO_DEVAD_NONE ,0x1d ,0x05 );/* enable rgmii tx clock delay */ -phy_write (phydev,MDIO_DEVAD_NONE ,0x1e ,0x100 ); +/* set the reserved bits to avoid board specific voltage peak issue*/ +phy_write (phydev,MDIO_DEVAD_NONE ,0x1e ,0x3D47 );return 0 ; }
Signature · 1 line
2.11.0
PATCH v2 1/2 board: ge: bx50v3: fix AR8033 reset timing issue
In reply to Ken LinQuoted 16 lines · Ken Lin
Add the delay (10ms) to ensure the clock is stable and to meet the clock-to-reset(1ms) requirement recommended in the AR8033 datasheet
Signed-off-by Ken Lin <[email protected]>---
Changes from v1
- Fix the missing Signed-off-by issueboard/ge/bx50v3/bx50v3.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-)board/ge/bx50v3/bx50v3.c +0
-0
board/ge/bx50v3/bx50v3.c static void setup_iomux_enet(void) · line 111
Quoted 10 lines
board/ge/bx50v3/bx50v3.c +2
-1@@ -103,8 +103,9 @@ static void setup_iomux_enet(void)/* Reset AR8033 PHY */ gpio_direction_output (IMX_GPIO_NR (1 ,28 ),0 ); -udelay (500 ); +mdelay (10 );gpio_set_value (IMX_GPIO_NR (1 ,28 ),1 ); +mdelay (1 ); }static iomux_v3_cfg_t const usdhc2_pads[] = {
Best regards,
Stefano Babic
Signature · 8 lines
Meet DENX at the Embedded World Trade Show 14 Mar - 16 Mar 2017, Nuremberg Trade Fair Centre, Hall 4, Booth 581 -- ===================================================================== DENX Software Engineering GmbH, Managing Director: Wolfgang Denk HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sbabic at denx.de =====================================================================
PATCH v2 2/2 board: ge: bx50v3: apply the proper register setting to fix the voltage peak issue
In reply to Ken LinQuoted 17 lines · Ken Lin
Apply the proper setting for the reserved bits in SetDes Test and System Mode Control register to avoid the voltage peak issue while we do the IEEE PHY comformance test
Signed-off-by Ken Lin <[email protected]>---
Changes from v1
- New commit messageboard/ge/bx50v3/bx50v3.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-)board/ge/bx50v3/bx50v3.c +0
-0
board/ge/bx50v3/bx50v3.c static int mx6_rgmii_rework(struct phy_device *phydev) · line 314
Quoted 9 lines
board/ge/bx50v3/bx50v3.c +2
-1@@ -307,7 +307,8 @@ static int mx6_rgmii_rework(struct phy_device *phydev)/* set debug port address: SerDes Test and System Mode Control */ phy_write (phydev,MDIO_DEVAD_NONE ,0x1d ,0x05 );/* enable rgmii tx clock delay */ -phy_write (phydev,MDIO_DEVAD_NONE ,0x1e ,0x100 ); +/* set the reserved bits to avoid board specific voltage peak issue*/ +phy_write (phydev,MDIO_DEVAD_NONE ,0x1e ,0x3D47 );return 0 ; }
Best regards,
Stefano Babic
Signature · 8 lines
Meet DENX at the Embedded World Trade Show 14 Mar - 16 Mar 2017, Nuremberg Trade Fair Centre, Hall 4, Booth 581 -- ===================================================================== DENX Software Engineering GmbH, Managing Director: Wolfgang Denk HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sbabic at denx.de =====================================================================
Ray
PATCH v2 2/2 board: ge: bx50v3: apply the proper register setting to fix the voltage peak issue
In reply to a message not in the archiveQuoted 25 lines · Stefano Babic
Quoted 1 line · Ken Lin
Apply the proper setting for the reserved bits in SetDes Test and System Mode
Control register
Quoted 22 lines
to avoid the voltage peak issue while we do the IEEE PHY comformance test
Signed-off-by Ken Lin <[email protected]>---
Changes from v1
- New commit messageboard/ge/bx50v3/bx50v3.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-)board/ge/bx50v3/bx50v3.c +2
-1@@ -307,7 +307,8 @@ static int mx6_rgmii_rework(struct phy_device *phydev)/* set debug port address: SerDes Test and System Mode Control */ phy_write (phydev,MDIO_DEVAD_NONE ,0x1d ,0x05 );/* enable rgmii tx clock delay */ -phy_write (phydev,MDIO_DEVAD_NONE ,0x1e ,0x100 ); +/* set the reserved bits to avoid board specific voltage peak issue*/ +phy_write (phydev,MDIO_DEVAD_NONE ,0x1e ,0x3D47 );
Quoted 5 lines
board/ge/bx50v3/bx50v3.c static int mx6_rgmii_rework(struct phy_device *phydev) · line 314
Quoted 3 lines
board/ge/bx50v3/bx50v3.c +0
-0return 0 ; }Reviewed-by Stefano Babic <[email protected]>
...
Ray
PATCH v2 1/2 board: ge: bx50v3: fix AR8033 reset timing issue
In reply to a message not in the archiveQuoted 26 lines · Stefano Babic
Quoted 1 line · Ken Lin
Add the delay (10ms) to ensure the clock is stable and to meet the clock-to-
reset(1ms) requirement recommended in the AR8033 datasheet
Quoted 23 lines
Signed-off-by Ken Lin <[email protected]>---
Changes from v1
- Fix the missing Signed-off-by issueboard/ge/bx50v3/bx50v3.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-)board/ge/bx50v3/bx50v3.c +2
-1@@ -103,8 +103,9 @@ static void setup_iomux_enet(void)/* Reset AR8033 PHY */ gpio_direction_output (IMX_GPIO_NR (1 ,28 ),0 ); -udelay (500 ); +mdelay (10 );gpio_set_value (IMX_GPIO_NR (1 ,28 ),1 ); +mdelay (1 ); }
Quoted 4 lines
board/ge/bx50v3/bx50v3.c static void setup_iomux_enet(void) · line 111
Quoted 2 lines
board/ge/bx50v3/bx50v3.c +0
-0static iomux_v3_cfg_t const usdhc2_pads[] = {Reviewed-by Stefano Babic <[email protected]>
...
PATCH v2 2/2 board: ge: bx50v3: apply the proper register setting to fix the voltage peak issue
In reply to RayHi Stefano,
Quoted 7 lines · Ian (GE Healthcare)
Quoted 6 lines · Stefano Babic
Quoted 1 line · Ken Lin
Apply the proper setting for the reserved bits in SetDes Test and System Mode
Control register
Quoted 3 lines
to avoid the voltage peak issue while we do the IEEE PHY comformance test
Signed-off-by Ken Lin <[email protected]>
Are you wanting to pull this series in or should I?
Thanks,
-Joe
PATCH v2 2/2 board: ge: bx50v3: apply the proper register setting to fix the voltage peak issue
Quoted 5 lines · Joe Hershberger
Hi Stefano,
Quoted 1 line · Ian (GE Healthcare)
On 21/02/2017 17:31, Stefano Babic wrote:
Quoted 8 lines
Quoted 6 lines
Quoted 6 lines · Ken Lin
Quoted 1 line
Apply the proper setting for the reserved bits in SetDes Test and System Mode
Control register
Quoted 3 lines
to avoid the voltage peak issue while we do the IEEE PHY comformance test
Signed-off-by Ken Lin <[email protected]>Are you wanting to pull this series in or should I?
Just searching the patches, I am just seeing that they are assigned to you (for that reason I have not pulled). On my side they are fine, you could pull them.
Stefano
Signature · 5 lines
===================================================================== DENX Software Engineering GmbH, Managing Director: Wolfgang Denk HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sbabic at denx.de =====================================================================
PATCH v2 2/2 board: ge: bx50v3: apply the proper register setting to fix the voltage peak issue
Quoted 11 lines · Stefano Babic
Quoted 10 lines · Joe Hershberger
Hi Stefano,
Quoted 6 lines · Ian (GE Healthcare)
Quoted 5 lines · Stefano Babic
Quoted 1 line · Ken Lin
Apply the proper setting for the reserved bits in SetDes Test and System Mode
Control register
Quoted 2 lines
to avoid the voltage peak issue while we do the IEEE PHY comformance test
Quoted 7 lines
Quoted 3 lines
Quoted 1 line
Quoted 1 line
Quoted 1 line
Signed-off-by Ken Lin <[email protected]>Are you wanting to pull this series in or should I?
Just searching the patches, I am just seeing that they are assigned to you (for that reason I have not pulled). On my side they are fine, you could pull them.
Will do.
-Joe
[U-Boot] board: ge: bx50v3: apply the proper register setting to fix the voltage peak issue
In reply to Ken Lin