mesh: Use correct length for config server response
PATCH 1/1 mesh: Use correct length for config server response
Also check if the length is nonzero before sending response
--- mesh/config-server.c | 20 +++++++++++--------- 1 file changed, 11 insertions(+), 9 deletions(-)
mesh/config-server.c +11 -9
@@ -59,8 +59,7 @@ static bool server_msg_recvd(uint16_t src, uint8_t *data,uint16_t ele_addr;uint8_t ele_idx;struct mesh_publication pub; - -int n; +int m, n;if (mesh_opcode_get (data, len, &opcode, &n)) { len -= n;
@@ -73,6 +72,8 @@ static bool server_msg_recvd(uint16_t src, uint8_t *data,if (!node)return true; + n =0 ; +switch (opcode & ~OP_UNRELIABLE ) {default :return false;
@@ -94,6 +95,7 @@ static bool server_msg_recvd(uint16_t src, uint8_t *data,break ;case OP_CONFIG_MODEL_PUB_SET : +if (len !=11 && len !=13 )return true;
@@ -110,19 +112,19 @@ static bool server_msg_recvd(uint16_t src, uint8_t *data, pub.app_idx =get_le16 (data +4 ); pub.ttl = data[6 ]; pub.period = data[7 ]; - n = (data[7 ] &0x3f ); + m = (data[7 ] &0x3f );switch (data[7 ] >>6 ) {case 0 : -rl_printf ("Period: %d ms\n" , n *100 ); +rl_printf ("Period: %d ms\n" , m *100 );break ;case 2 : - n *=10 ; + m *=10 ;/* fall through */ case 1 : -rl_printf ("Period: %d sec\n" , n); +rl_printf ("Period: %d sec\n" , m);break ;case 3 : -rl_printf ("Period: %d min\n" , n *10 ); +rl_printf ("Period: %d min\n" , m *10 );break ; }
@@ -140,9 +142,9 @@ static bool server_msg_recvd(uint16_t src, uint8_t *data, } primary =node_get_primary (node); -if (src != primary) +if (n && src != primary)net_access_layer_send (node_get_default_ttl (node), primary, - src,APP_IDX_DEV , msg, len); + src,APP_IDX_DEV , msg, n);return true; }
Signature · 1 line
2.9.5
Hi Inga,
Quoted 74 lines · Inga Stotland
Also check if the length is nonzero before sending response
--- mesh/config-server.c | 20 +++++++++++--------- 1 file changed, 11 insertions(+), 9 deletions(-)mesh/config-server.c +11
-10@@ -59,8 +59,7 @@ static bool server_msg_recvd(uint16_t src, uint8_t *data,uint16_t ele_addr;uint8_t ele_idx;struct mesh_publication pub; - -int n; +int m, n;if (mesh_opcode_get (data, len, &opcode, &n)) { len -= n;@@ -73,6 +72,8 @@ static bool server_msg_recvd(uint16_t src, uint8_t *data,if (!node)return true; + n =0 ; +switch (opcode & ~OP_UNRELIABLE ) {default :return false;@@ -94,6 +95,7 @@ static bool server_msg_recvd(uint16_t src, uint8_t *data,break ;case OP_CONFIG_MODEL_PUB_SET : +if (len !=11 && len !=13 )return true;@@ -110,19 +112,19 @@ static bool server_msg_recvd(uint16_t src, uint8_t *data, pub.app_idx =get_le16 (data +4 ); pub.ttl = data[6 ]; pub.period = data[7 ]; - n = (data[7 ] &0x3f ); + m = (data[7 ] &0x3f );switch (data[7 ] >>6 ) {case 0 : -rl_printf ("Period: %d ms\n" , n *100 ); +rl_printf ("Period: %d ms\n" , m *100 );break ;case 2 : - n *=10 ; + m *=10 ;/* fall through */ case 1 : -rl_printf ("Period: %d sec\n" , n); +rl_printf ("Period: %d sec\n" , m);break ;case 3 : -rl_printf ("Period: %d min\n" , n *10 ); +rl_printf ("Period: %d min\n" , m *10 );break ; }@@ -140,9 +142,9 @@ static bool server_msg_recvd(uint16_t src, uint8_t *data, } primary =node_get_primary (node); -if (src != primary) +if (n && src != primary)net_access_layer_send (node_get_default_ttl (node), primary, - src,APP_IDX_DEV , msg, len); + src,APP_IDX_DEV , msg, n);return true; } --
Quoted 1 line
2.9.5
Applied, thanks.
Signature · 1 line
Luiz Augusto von Dentz