iio: hx711: fix bug in reset functionality
Subsystems (2)
Andreas Klinger
maintainerPATCH 2/2 iio: hx711: fix bug in reset functionality
return value in hx711_reset() should indicate status of dout otherwise the calling function is reporting an error als false positive
wait up to 1 second until the device is in normal state;
by changing the channel on every trigger event it turned out that the former 100 ms are not enough for waiting until the device is in normal mode
Signed-off-by Andreas Klinger <[email protected]>
--- drivers/iio/adc/hx711.c | 13 ++++++------- 1 file changed, 6 insertions(+), 7 deletions(-)
drivers/iio/adc/hx711.c +6 -7
@@ -153,15 +153,16 @@ static int hx711_wait_for_ready(struct hx711_data *hx711_data)int i, val;/* -* a maximum reset cycle time of 56 ms was measured. -* we round it up to 100 ms +* in some rare cases the reset takes quite a long time +* especially when the channel is changed. +* Allow up to one second for it */ for (i =0 ; i <100 ; i++) { val =gpiod_get_value (hx711_data->gpiod_dout);if (!val)break ; -/* sleep at least 1 ms */ -msleep (1 ); +/* sleep at least 10 ms */ +msleep (10 ); }if (val)return -EIO ;
@@ -203,9 +204,7 @@ static int hx711_reset(struct hx711_data *hx711_data)* after a dummy read we need to wait vor readiness * for not mixing gain pulses with the clock */ - ret =hx711_wait_for_ready (hx711_data); -if (ret) -return ret; + val =hx711_wait_for_ready (hx711_data); }return val;
Signature · 4 lines
2.1.4 --