tools/power turbostat: if --max_loop, print for specific time of loops
RFC PATCH 1/1 tools/power turbostat: if --max_loop, print for specific time of loops
From: Chen Yu <[email protected]>
There's a use case during test to only print specific round of loops if --interval is specified, for example, with this patch applied:
turbostat -i 5 --max_loops 4
will capture 4 samples with 5 seconds interval.
--- tools/power/x86/turbostat/turbostat.c | 19 ++++++++++++++++++- 1 file changed, 18 insertions(+), 1 deletion(-)
tools/power/x86/turbostat/turbostat.c +18 -1
@@ -48,6 +48,7 @@ char *proc_stat = "/proc/stat";FILE *outf;int *fd_percpu;struct timespec interval_ts = {5 ,0 }; +unsigned int max_loops;unsigned int debug;unsigned int quiet;unsigned int sums_need_wide_columns;
@@ -470,6 +471,7 @@ void help(void)" {core | package | j,k,l..m,n-p }\n" "--quiet skip decoding system configuration header\n" "--interval sec Override default 5-second measurement interval\n" +"--max_loops times The number of loops if interval is specified\n" "--help print this help message\n" "--list list column headers only\n" "--out file create or truncate \"file\" for all output\n"
@@ -2565,6 +2567,7 @@ void turbostat_loop() {int retval;int restarted =0 ; +int loops =0 ; restart: restarted++;
@@ -2583,6 +2586,7 @@ void turbostat_loop() restarted =0 ;gettimeofday (&tv_even, (struct timezone *)NULL ); + loops =0 ;while (1 ) {if (for_all_proc_cpus (cpu_is_not_present)) {re_initialize ();
@@ -2626,6 +2630,9 @@ void turbostat_loop()compute_average (ODD_COUNTERS );format_all_counters (ODD_COUNTERS );flush_output_stdout (); + +if (++loops >= (max_loops/2 )) +break ; } }
@@ -5009,12 +5016,13 @@ void cmdline(int argc, char **argv) {"Summary", no_argument, 0, 'S'}, {"TCC", required_argument, 0, 'T'}, {"version", no_argument, 0, 'v' }, + {"max_loops", required_argument, 0, 'x'}, {0, 0, 0, 0 } }; progname = argv[0 ]; -while ((opt =getopt_long_only (argc, argv,"+C:c:Ddhi:JM:m:o:qST:v" , +while ((opt =getopt_long_only (argc, argv,"+C:c:Ddhi:JM:m:o:qST:vx:" , long_options, &option_index)) !=-1 ) {switch (opt) {case 'a' :
@@ -5076,6 +5084,15 @@ void cmdline(int argc, char **argv)print_version ();exit (0 );break ; +case 'x' : + { +unsigned int loops =strtod (optarg,NULL ); + +if (loops %2 ) + loops++; + max_loops = loops; + } +break ; } } }
Signature · 1 line
2.13.6
Quoted 7 lines · Yu Chen
From: Chen Yu <[email protected]>
There's a use case during test to only print specific round of loops if --interval is specified, for example, with this patch applied:
turbostat -i 5 --max_loops 4
will capture 4 samples with 5 seconds interval.
Why --max_loops and not just --loops or --iterations?
Quoted 85 lines
Signed-off-by Chen Yu <[email protected]>--- tools/power/x86/turbostat/turbostat.c | 19 ++++++++++++++++++- 1 file changed, 18 insertions(+), 1 deletion(-)tools/power/x86/turbostat/turbostat.c +18
-2@@ -48,6 +48,7 @@ char *proc_stat = "/proc/stat";FILE *outf;int *fd_percpu;struct timespec interval_ts = {5 ,0 }; +unsigned int max_loops;unsigned int debug;unsigned int quiet;unsigned int sums_need_wide_columns;@@ -470,6 +471,7 @@ void help(void)" {core | package | j,k,l..m,n-p }\n" "--quiet skip decoding system configuration header\n" "--interval sec Override default 5-second measurement interval\n" +"--max_loops times The number of loops if interval is specified\n" "--help print this help message\n" "--list list column headers only\n" "--out file create or truncate \"file\" for all output\n" @@ -2565,6 +2567,7 @@ void turbostat_loop() {int retval;int restarted =0 ; +int loops =0 ; restart: restarted++;@@ -2583,6 +2586,7 @@ void turbostat_loop() restarted =0 ;gettimeofday (&tv_even, (struct timezone *)NULL ); + loops =0 ;while (1 ) {if (for_all_proc_cpus (cpu_is_not_present)) {re_initialize ();@@ -2626,6 +2630,9 @@ void turbostat_loop()compute_average (ODD_COUNTERS );format_all_counters (ODD_COUNTERS );flush_output_stdout (); + +if (++loops >= (max_loops/2 )) +break ; } }@@ -5009,12 +5016,13 @@ void cmdline(int argc, char **argv) {"Summary", no_argument, 0, 'S'}, {"TCC", required_argument, 0, 'T'}, {"version", no_argument, 0, 'v' }, + {"max_loops", required_argument, 0, 'x'}, {0, 0, 0, 0 } }; progname = argv[0 ]; -while ((opt =getopt_long_only (argc, argv,"+C:c:Ddhi:JM:m:o:qST:v" , +while ((opt =getopt_long_only (argc, argv,"+C:c:Ddhi:JM:m:o:qST:vx:" , long_options, &option_index)) !=-1 ) {switch (opt) {case 'a' :@@ -5076,6 +5084,15 @@ void cmdline(int argc, char **argv)print_version ();exit (0 );break ; +case 'x' : + { +unsigned int loops =strtod (optarg,NULL ); + +if (loops %2 ) + loops++; + max_loops = loops; + } +break ; } } } --2.13.6
Quoted 4 lines · Rafael J. Wysocki
Quoted 2 lines · Yu Chen
From: Chen Yu <[email protected]>
Quoted 8 lines
Quoted 6 lines
There's a use case during test to only print specific round of loops
if --interval is specified, for example, with this patch applied:turbostat -i 5 --max_loops 4
will capture 4 samples with 5 seconds interval.Why --max_loops and not just --loops or --iterations?
Or just --count.
Artem.
tools/power/x86/turbostat/turbostat.c void cmdline(int argc, char **argv) · line 5089
Quoted 7 lines · Yu Chen
tools/power/x86/turbostat/turbostat.c +3
-0@@ -5076,6 +5084,15 @@ void cmdline(int argc, char **argv)print_version ();exit (0 );break ; +case 'x' : + { +unsigned int loops =strtod (optarg,NULL );
It would make sense to error out here if you get a value <= 0.
tools/power/x86/turbostat/turbostat.c void cmdline(int argc, char **argv) · line 5092
Quoted 3 lines
tools/power/x86/turbostat/turbostat.c +3
-0+ +if (loops %2 ) + loops++;
What is this for?
tools/power/x86/turbostat/turbostat.c void cmdline(int argc, char **argv) · line 5093
Quoted 1 line
tools/power/x86/turbostat/turbostat.c +1
-0+ max_loops = loops;
Is the "loops" variable really needed? Can you strtod directly to max_loops?
Signature · 12 lines
Best Regards, Artem Bityutskiy --------------------------------------------------------------------- Intel Finland Oy Registered Address: PL 281, 00181 Helsinki Business Identity Code: 0357606 - 4 Domiciled in Helsinki This e-mail and any attachments may contain confidential material for the sole use of the intended recipient(s). Any review or distribution by others is strictly prohibited. If you are not the intended recipient, please contact the sender and delete all copies.
Quoted 11 lines · Rafael J. Wysocki
Quoted 7 lines · Yu Chen
From: Chen Yu <[email protected]>
There's a use case during test to only print specific round of loops if --interval is specified, for example, with this patch applied:
turbostat -i 5 --max_loops 4
will capture 4 samples with 5 seconds interval.Why --max_loops and not just --loops or --iterations?
I thought -l has been used already. OK, changed to --interation and -t respectively.
Thanks!
Hi,
Quoted 11 lines · Artem
tools/power/x86/turbostat/turbostat.c void cmdline(int argc, char **argv) · line 5089
Quoted 7 lines · Yu Chen
tools/power/x86/turbostat/turbostat.c +3
-0@@ -5076,6 +5084,15 @@ void cmdline(int argc, char **argv)print_version ();exit (0 );break ; +case 'x' : + { +unsigned int loops =strtod (optarg,NULL );It would make sense to error out here if you get a value <= 0.
OK.
Quoted 6 lines
tools/power/x86/turbostat/turbostat.c void cmdline(int argc, char **argv) · line 5092
Quoted 3 lines
tools/power/x86/turbostat/turbostat.c +3
-0+ +if (loops %2 ) + loops++;What is this for?
It was intended to make the number of loops even for simplify. But after rethink about this, it might not be necessary. I'll change it.
Quoted 4 lines
tools/power/x86/turbostat/turbostat.c void cmdline(int argc, char **argv) · line 5093
Quoted 1 line
tools/power/x86/turbostat/turbostat.c +1
-0+ max_loops = loops;Is the "loops" variable really needed? Can you strtod directly to
max_loops?
If the sanity check for user input is added then I think the local variable is needed.
Thanks,
Yu
Quoted 4 lines
Signature · 3 lines
-- Best Regards, Artem Bityutskiy