Improve the accuracy of the baud rate generator by using round-to-closest instead of truncating when calculating baud rate divisors.
Quoted 23 lines · Nikolaj Fogh
Quoted 16 lines · Johan Hovold
Quoted 8 lines · Nikolaj Fogh
Quoted 7 lines · Johan Hovold
Quoted 6 lines · Nikolaj Fogh
I have experienced that the
ftdi_siodriver gives less-than-optimal baud rates as the driver truncates instead of rounds to nearest during baud rate divisor calculation.
This patch improves on the baud rate generation. The generated baud rate corresponds to the optimal baud rate achievable with the chip. This is what the windows driver gives as well.Quoted 7 lines
Quoted 3 lines
How did you verify this? Did you trace and compare the divisors actually requested by the Windows driver, or did you measure the resulting rates using a scope?
I verified it by scope. Granted, I only verified it for one baud rate (961200). Whether it gives the same as the Windows driver in general, I'm not sure. However, I would think that rounding instead of flooring would always yield the most accurate result.
Quoted 5 lines
I'm not so sure in this case. The driver uses "sub-integer" divisors and looks like it depends on truncation rather than rounding. Some background here:
https://www.ftdichip.com/Support/Knowledgebase/index.html?whatbaudratesareachieveabl.htm
Quoted 7 lines
I have had a closer look at this (and the driver code), and it seemsthat each bit in the divisorcorresponds to 1/8th (0.125) in the calculation.
It is shuffled around a bit in the code (for legacy reasons I expect), and put in the higher order bits, but prior to that, I see no reason that rounding should not be used instead of truncating. I don't see how it "depends" on truncation.
As I mentioned in my follow-up mail, I agree with that; your proposed change looks correct.
Quoted 10 lines
Quoted 3 lines
If you want to change these calculations you need to make a stronger case for it and verify that we don't mess up some other rate inadvertently.
I have done a calculation which compares the error of the baud rate calculation going all the way from 1 to 3MBaud where it can be seen that the rounding (as expected) halves the maximum error. Whereas the old method went up to 12% baud rate error, the new method reaches 6%, so the range of baud rates where communication will be successful should increase. Also, the new method is always better or as-accurate as the old.
Excellent, thanks for confirming. Just mention something about that in the commit message too.
Quoted 3 lines
I guess that image attachments are not welcome in the mailing list, so I will refrain from attaching it. Let me know if I should send it to you.
Sure, if you want too that'd be great.
Quoted 3 lines
I am using it in a system which uses a baud rate of 961200 (and not the standard 921600). Here the old calculation gave an error of 4.03% and the new gave 0.12% error.
Also good to have in the commit message.
Quoted 3 lines
I will try to verify the numbers I have calculated with a logic analyzer to make sure that it corresponds with the real world. I can also try to compare it to the windows driver outputs.
That would be really good, at least for a few rates.
Quoted 2 lines
As I only have a FT232RT (232bm) to test with, the patch should probably be limited to the changes in the
ftdi_232bm_baud_base_to_divisor()function.
No, as long as you mention which device you used for testing, and the numbers for the other other types looks similar, I think we can go ahead and round those divisions too.
Thanks for doing this!