TPL max size for RK3288 ?
Hey,
So I was playing with how to make our linker scripts more re-usable and have the kinds of link error on excessive size checks that we find really useful to avoid introducing run time failures, and I found something. On rk3288 we don't size TPL_MAX_SIZE, only for rk3368. Is there a reasonable one to set here? Thanks!
Signature · 8 lines
Tom -------------- next part -------------- A non-text attachment was scrubbed... Name: signature.asc Type: application/pgp-signature Size: 819 bytes Desc: not available URL: <http://lists.denx.de/pipermail/u-boot/attachments/20190118/7dee31e2/attachment.sig>
Hi Tom,
Quoted 8 lines · Tom Rini
Hey,
So I was playing with how to make our linker scripts more re-usable and have the kinds of link error on excessive size checks that we find really useful to avoid introducing run time failures, and I found something. On rk3288 we don't size
TPL_MAX_SIZE, only for rk3368. Is there a reasonable one to set here? Thanks!
We did not enable TPL for rk3288 at first, and now there already one rk3288 board using TPL, so it's reasonable to use TPL_MAX_SIZE for rk3288.
rk3288's TPL_MAX_SIZE is 32768.
Thanks,
- Kever