media: rc: ir-rc6-decoder: enable toggle bit for Zotac remotes
Subsystems (2)
PATCH 1/1 media: rc: ir-rc6-decoder: enable toggle bit for Zotac remotes
The Zotac RC2604323/01G and RC2604329/02BG remotes use the 32-bit rc6 protocol and toggle bit 15 (0x8000) on repeated button presses, like MCE remotes.
Add the customer code 0x80340000 to the 32-bit rc6 toggle handling code to get proper scancodes and toggle reports.
Signed-off-by Matthias Reichl <[email protected]>
---
LibreELEC bug report and more info are here:
https://forum.libreelec.tv/thread/14388-ir-remote-malfunction-after-upgrade-to-le-9-0/
drivers/media/rc/ir-rc6-decoder.c +2 -0
@@ -40,6 +40,7 @@#define RC6_6A_MCE_TOGGLE_MASK 0x8000/* for the body bits */ #define RC6_6A_LCC_MASK 0xffff0000/* RC6-6A-32 long customer code mask */ #define RC6_6A_MCE_CC 0x800f0000/* MCE customer code */ +#define RC6_6A_ZOTAC_CC 0x80340000/* Zotac customer code */ #define RC6_6A_KATHREIN_CC 0x80460000/* Kathrein RCU-676 customer code */ #ifndef CHAR_BIT #define CHAR_BIT 8/* Normally in <limits.h> */
@@ -246,6 +247,7 @@ static int ir_rc6_decode(struct rc_dev *dev, struct ir_raw_event ev)switch (scancode &RC6_6A_LCC_MASK ) {case RC6_6A_MCE_CC :case RC6_6A_KATHREIN_CC : +case RC6_6A_ZOTAC_CC : protocol =RC_PROTO_RC6_MCE ; toggle = !!(scancode &RC6_6A_MCE_TOGGLE_MASK ); scancode &= ~RC6_6A_MCE_TOGGLE_MASK ;
Signature · 1 line