Skip to contentSkip to conversation

ARM: dts: s5pv210: Fix camera clock provider for Goni board

RFT Krzysztof Kozlowski 1 participant 1 message Apr 15, 2019

Subsystems (2)
lore
Share & tools
lore

Krzysztof Kozlowski

author maintainer
#0 lore raw

The camera driver (according also to bindings) registers a clock provider if clock-output-names property is present and later the sensors use registered clocks.

The DTS for S5Pv210 Goni board was incorrectly adding a child node with clock output cells but without clock-output-names property. Although the DTS was compiling (with "/soc/camera/clock-controller: missing or empty reg/ranges property" warning), the clock provider was not registered.

---

Not tested.

---
 arch/arm/boot/dts/s5pv210-goni.dts | 2 +-
 arch/arm/boot/dts/s5pv210.dtsi     | 6 ++----
 2 files changed, 3 insertions(+), 5 deletions(-)
arch/arm/boot/dts/s5pv210-goni.dts +1 -1
index eb6d1926c0d6..fbbd93707404 100644
@@ -376,7 +376,7 @@
 		vdd_core-supply = <&ldo14_reg>;
 
 		clock-frequency = <16000000>;
-		clocks = <&clock_cam 0>;
+		clocks = <&camera 0>;
 		clock-names = "mclk";
 		nreset-gpios = <&gpb 2 0>;
 		nstby-gpios = <&gpb 0 0>;
arch/arm/boot/dts/s5pv210.dtsi +2 -4
index a44d5eb56bed..2ad642f51fd9 100644
@@ -585,12 +585,10 @@
 			clock-names = "sclk_cam0", "sclk_cam1";
 			#address-cells = <1>;
 			#size-cells = <1>;
+			#clock-cells = <1>;
+			clock-output-names = "cam_a_clkout", "cam_b_clkout";
 			ranges;
 
-			clock_cam: clock-controller {
-				#clock-cells = <1>;
-			};
-
 			csis0: csis@fa600000 {
 				compatible = "samsung,s5pv210-csis";
 				reg = <0xfa600000 0x4000>;
Signature · 1 line