blktests: nvme: Fix pass data of nvmet TCs
Subsystems (2)
cover blktests: nvme: Fix pass data of nvmet TCs
Hi, Omar,
This patchset fixes mismatch between expected pass data and real data printed out for nvmet testcases.
It has been long time to have changes for nvmet and nvme-cli. The following commits can explain why the pass data has to be updated.
About genctr:
Commit b662a078 ("nvmet: enable Discovery Controller AENs")
About treq field:
- nvmet:
Commit 9b95d2fb ("nvmet: expose support for fabrics SQ flow control
disable in treq")
- nvme-cli:
Commit 2cf370c3 ("fabrics: support fabrics sq flow control disable")
Please correct me if I'm wrong here. :)
Thanks,
*** BLURB HERE ***
Minwoo Im (3):
nvme: 002: fix nvmet pass data with loop
nvme: 016: fix nvmet pass data with loop
nvme: 017: fix nvmet pass data with loop
tests/nvme/002.out | 2002 ++++++++++++++++++++++++++-------------------------- tests/nvme/016.out | 4 +- tests/nvme/017.out | 4 +- 3 files changed, 1005 insertions(+), 1005 deletions(-)
Signature · 1 line
2.7.4
PATCH 1/3 nvme: 002: fix nvmet pass data with loop
genctr has also incremented two times in the following two steps:
1. echo 1 > $CFG/nvmet/subsystems/$SUB/attr_allow_any_host via nvmet_subsys_attr_allow_any_host_store()
2. ln -s $CFG/nvmet/subsystems/$SUB $CFG/nvmet/port/$PORT/subsystems/ via nvmet_allowed_hosts_allow_link()
genctrl updated in step 1. has been updated by the following commit:
b662a078 ("nvmet: enable Discovery Controller AENs")
This patch makes result value to a x2 value.
it also has been a long time to have nvmet configfs with TP 8005 applied for nvmet. Commit 9b95d2fb ("nvmet: expose support for fabrics SQ flow control disable in treq") supports sq flow control disabling attribute so that get log page to discovery has treq value with an updated value which has been applied by a commit 2cf370c3 ("fabrics:
support fabrics sq flow control disable") in nvme-cli.
--- tests/nvme/002.out | 2002 ++++++++++++++++++++++++++-------------------------- 1 file changed, 1001 insertions(+), 1001 deletions(-)
tests/nvme/002.out +1001 -1001
@@ -1,11 +1,11 @@ Running nvme/002 -Discovery Log Number of Records 1000, Generation counter 1000 +Discovery Log Number of Records 1000, Generation counter 2000 =====Discovery Log Entry 0====== trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-0
@@ -14,7 +14,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-1
@@ -23,7 +23,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-2
@@ -32,7 +32,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-3
@@ -41,7 +41,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-4
@@ -50,7 +50,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-5
@@ -59,7 +59,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-6
@@ -68,7 +68,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-7
@@ -77,7 +77,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-8
@@ -86,7 +86,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-9
@@ -95,7 +95,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-10
@@ -104,7 +104,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-11
@@ -113,7 +113,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-12
@@ -122,7 +122,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-13
@@ -131,7 +131,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-14
@@ -140,7 +140,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-15
@@ -149,7 +149,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-16
@@ -158,7 +158,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-17
@@ -167,7 +167,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-18
@@ -176,7 +176,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-19
@@ -185,7 +185,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-20
@@ -194,7 +194,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-21
@@ -203,7 +203,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-22
@@ -212,7 +212,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-23
@@ -221,7 +221,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-24
@@ -230,7 +230,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-25
@@ -239,7 +239,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-26
@@ -248,7 +248,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-27
@@ -257,7 +257,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-28
@@ -266,7 +266,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-29
@@ -275,7 +275,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-30
@@ -284,7 +284,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-31
@@ -293,7 +293,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-32
@@ -302,7 +302,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-33
@@ -311,7 +311,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-34
@@ -320,7 +320,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-35
@@ -329,7 +329,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-36
@@ -338,7 +338,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-37
@@ -347,7 +347,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-38
@@ -356,7 +356,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-39
@@ -365,7 +365,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-40
@@ -374,7 +374,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-41
@@ -383,7 +383,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-42
@@ -392,7 +392,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-43
@@ -401,7 +401,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-44
@@ -410,7 +410,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-45
@@ -419,7 +419,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-46
@@ -428,7 +428,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-47
@@ -437,7 +437,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-48
@@ -446,7 +446,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-49
@@ -455,7 +455,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-50
@@ -464,7 +464,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-51
@@ -473,7 +473,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-52
@@ -482,7 +482,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-53
@@ -491,7 +491,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-54
@@ -500,7 +500,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-55
@@ -509,7 +509,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-56
@@ -518,7 +518,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-57
@@ -527,7 +527,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-58
@@ -536,7 +536,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-59
@@ -545,7 +545,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-60
@@ -554,7 +554,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-61
@@ -563,7 +563,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-62
@@ -572,7 +572,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-63
@@ -581,7 +581,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-64
@@ -590,7 +590,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-65
@@ -599,7 +599,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-66
@@ -608,7 +608,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-67
@@ -617,7 +617,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-68
@@ -626,7 +626,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-69
@@ -635,7 +635,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-70
@@ -644,7 +644,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-71
@@ -653,7 +653,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-72
@@ -662,7 +662,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-73
@@ -671,7 +671,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-74
@@ -680,7 +680,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-75
@@ -689,7 +689,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-76
@@ -698,7 +698,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-77
@@ -707,7 +707,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-78
@@ -716,7 +716,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-79
@@ -725,7 +725,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-80
@@ -734,7 +734,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-81
@@ -743,7 +743,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-82
@@ -752,7 +752,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-83
@@ -761,7 +761,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-84
@@ -770,7 +770,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-85
@@ -779,7 +779,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-86
@@ -788,7 +788,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-87
@@ -797,7 +797,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-88
@@ -806,7 +806,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-89
@@ -815,7 +815,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-90
@@ -824,7 +824,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-91
@@ -833,7 +833,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-92
@@ -842,7 +842,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-93
@@ -851,7 +851,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-94
@@ -860,7 +860,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-95
@@ -869,7 +869,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-96
@@ -878,7 +878,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-97
@@ -887,7 +887,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-98
@@ -896,7 +896,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-99
@@ -905,7 +905,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-100
@@ -914,7 +914,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-101
@@ -923,7 +923,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-102
@@ -932,7 +932,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-103
@@ -941,7 +941,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-104
@@ -950,7 +950,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-105
@@ -959,7 +959,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-106
@@ -968,7 +968,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-107
@@ -977,7 +977,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-108
@@ -986,7 +986,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-109
@@ -995,7 +995,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-110
@@ -1004,7 +1004,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-111
@@ -1013,7 +1013,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-112
@@ -1022,7 +1022,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-113
@@ -1031,7 +1031,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-114
@@ -1040,7 +1040,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-115
@@ -1049,7 +1049,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-116
@@ -1058,7 +1058,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-117
@@ -1067,7 +1067,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-118
@@ -1076,7 +1076,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-119
@@ -1085,7 +1085,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-120
@@ -1094,7 +1094,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-121
@@ -1103,7 +1103,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-122
@@ -1112,7 +1112,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-123
@@ -1121,7 +1121,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-124
@@ -1130,7 +1130,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-125
@@ -1139,7 +1139,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-126
@@ -1148,7 +1148,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-127
@@ -1157,7 +1157,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-128
@@ -1166,7 +1166,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-129
@@ -1175,7 +1175,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-130
@@ -1184,7 +1184,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-131
@@ -1193,7 +1193,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-132
@@ -1202,7 +1202,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-133
@@ -1211,7 +1211,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-134
@@ -1220,7 +1220,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-135
@@ -1229,7 +1229,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-136
@@ -1238,7 +1238,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-137
@@ -1247,7 +1247,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-138
@@ -1256,7 +1256,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-139
@@ -1265,7 +1265,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-140
@@ -1274,7 +1274,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-141
@@ -1283,7 +1283,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-142
@@ -1292,7 +1292,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-143
@@ -1301,7 +1301,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-144
@@ -1310,7 +1310,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-145
@@ -1319,7 +1319,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-146
@@ -1328,7 +1328,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-147
@@ -1337,7 +1337,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-148
@@ -1346,7 +1346,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-149
@@ -1355,7 +1355,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-150
@@ -1364,7 +1364,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-151
@@ -1373,7 +1373,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-152
@@ -1382,7 +1382,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-153
@@ -1391,7 +1391,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-154
@@ -1400,7 +1400,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-155
@@ -1409,7 +1409,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-156
@@ -1418,7 +1418,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-157
@@ -1427,7 +1427,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-158
@@ -1436,7 +1436,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-159
@@ -1445,7 +1445,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-160
@@ -1454,7 +1454,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-161
@@ -1463,7 +1463,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-162
@@ -1472,7 +1472,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-163
@@ -1481,7 +1481,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-164
@@ -1490,7 +1490,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-165
@@ -1499,7 +1499,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-166
@@ -1508,7 +1508,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-167
@@ -1517,7 +1517,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-168
@@ -1526,7 +1526,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-169
@@ -1535,7 +1535,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-170
@@ -1544,7 +1544,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-171
@@ -1553,7 +1553,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-172
@@ -1562,7 +1562,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-173
@@ -1571,7 +1571,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-174
@@ -1580,7 +1580,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-175
@@ -1589,7 +1589,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-176
@@ -1598,7 +1598,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-177
@@ -1607,7 +1607,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-178
@@ -1616,7 +1616,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-179
@@ -1625,7 +1625,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-180
@@ -1634,7 +1634,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-181
@@ -1643,7 +1643,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-182
@@ -1652,7 +1652,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-183
@@ -1661,7 +1661,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-184
@@ -1670,7 +1670,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-185
@@ -1679,7 +1679,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-186
@@ -1688,7 +1688,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-187
@@ -1697,7 +1697,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-188
@@ -1706,7 +1706,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-189
@@ -1715,7 +1715,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-190
@@ -1724,7 +1724,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-191
@@ -1733,7 +1733,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-192
@@ -1742,7 +1742,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-193
@@ -1751,7 +1751,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-194
@@ -1760,7 +1760,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-195
@@ -1769,7 +1769,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-196
@@ -1778,7 +1778,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-197
@@ -1787,7 +1787,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-198
@@ -1796,7 +1796,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-199
@@ -1805,7 +1805,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-200
@@ -1814,7 +1814,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-201
@@ -1823,7 +1823,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-202
@@ -1832,7 +1832,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-203
@@ -1841,7 +1841,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-204
@@ -1850,7 +1850,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-205
@@ -1859,7 +1859,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-206
@@ -1868,7 +1868,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-207
@@ -1877,7 +1877,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-208
@@ -1886,7 +1886,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-209
@@ -1895,7 +1895,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-210
@@ -1904,7 +1904,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-211
@@ -1913,7 +1913,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-212
@@ -1922,7 +1922,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-213
@@ -1931,7 +1931,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-214
@@ -1940,7 +1940,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-215
@@ -1949,7 +1949,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-216
@@ -1958,7 +1958,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-217
@@ -1967,7 +1967,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-218
@@ -1976,7 +1976,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-219
@@ -1985,7 +1985,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-220
@@ -1994,7 +1994,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-221
@@ -2003,7 +2003,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-222
@@ -2012,7 +2012,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-223
@@ -2021,7 +2021,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-224
@@ -2030,7 +2030,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-225
@@ -2039,7 +2039,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-226
@@ -2048,7 +2048,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-227
@@ -2057,7 +2057,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-228
@@ -2066,7 +2066,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-229
@@ -2075,7 +2075,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-230
@@ -2084,7 +2084,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-231
@@ -2093,7 +2093,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-232
@@ -2102,7 +2102,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-233
@@ -2111,7 +2111,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-234
@@ -2120,7 +2120,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-235
@@ -2129,7 +2129,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-236
@@ -2138,7 +2138,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-237
@@ -2147,7 +2147,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-238
@@ -2156,7 +2156,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-239
@@ -2165,7 +2165,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-240
@@ -2174,7 +2174,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-241
@@ -2183,7 +2183,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-242
@@ -2192,7 +2192,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-243
@@ -2201,7 +2201,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-244
@@ -2210,7 +2210,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-245
@@ -2219,7 +2219,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-246
@@ -2228,7 +2228,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-247
@@ -2237,7 +2237,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-248
@@ -2246,7 +2246,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-249
@@ -2255,7 +2255,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-250
@@ -2264,7 +2264,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-251
@@ -2273,7 +2273,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-252
@@ -2282,7 +2282,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-253
@@ -2291,7 +2291,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-254
@@ -2300,7 +2300,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-255
@@ -2309,7 +2309,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-256
@@ -2318,7 +2318,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-257
@@ -2327,7 +2327,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-258
@@ -2336,7 +2336,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-259
@@ -2345,7 +2345,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-260
@@ -2354,7 +2354,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-261
@@ -2363,7 +2363,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-262
@@ -2372,7 +2372,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-263
@@ -2381,7 +2381,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-264
@@ -2390,7 +2390,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-265
@@ -2399,7 +2399,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-266
@@ -2408,7 +2408,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-267
@@ -2417,7 +2417,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-268
@@ -2426,7 +2426,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-269
@@ -2435,7 +2435,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-270
@@ -2444,7 +2444,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-271
@@ -2453,7 +2453,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-272
@@ -2462,7 +2462,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-273
@@ -2471,7 +2471,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-274
@@ -2480,7 +2480,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-275
@@ -2489,7 +2489,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-276
@@ -2498,7 +2498,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-277
@@ -2507,7 +2507,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-278
@@ -2516,7 +2516,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-279
@@ -2525,7 +2525,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-280
@@ -2534,7 +2534,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-281
@@ -2543,7 +2543,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-282
@@ -2552,7 +2552,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-283
@@ -2561,7 +2561,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-284
@@ -2570,7 +2570,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-285
@@ -2579,7 +2579,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-286
@@ -2588,7 +2588,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-287
@@ -2597,7 +2597,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-288
@@ -2606,7 +2606,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-289
@@ -2615,7 +2615,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-290
@@ -2624,7 +2624,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-291
@@ -2633,7 +2633,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-292
@@ -2642,7 +2642,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-293
@@ -2651,7 +2651,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-294
@@ -2660,7 +2660,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-295
@@ -2669,7 +2669,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-296
@@ -2678,7 +2678,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-297
@@ -2687,7 +2687,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-298
@@ -2696,7 +2696,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-299
@@ -2705,7 +2705,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-300
@@ -2714,7 +2714,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-301
@@ -2723,7 +2723,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-302
@@ -2732,7 +2732,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-303
@@ -2741,7 +2741,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-304
@@ -2750,7 +2750,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-305
@@ -2759,7 +2759,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-306
@@ -2768,7 +2768,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-307
@@ -2777,7 +2777,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-308
@@ -2786,7 +2786,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-309
@@ -2795,7 +2795,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-310
@@ -2804,7 +2804,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-311
@@ -2813,7 +2813,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-312
@@ -2822,7 +2822,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-313
@@ -2831,7 +2831,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-314
@@ -2840,7 +2840,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-315
@@ -2849,7 +2849,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-316
@@ -2858,7 +2858,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-317
@@ -2867,7 +2867,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-318
@@ -2876,7 +2876,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-319
@@ -2885,7 +2885,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-320
@@ -2894,7 +2894,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-321
@@ -2903,7 +2903,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-322
@@ -2912,7 +2912,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-323
@@ -2921,7 +2921,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-324
@@ -2930,7 +2930,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-325
@@ -2939,7 +2939,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-326
@@ -2948,7 +2948,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-327
@@ -2957,7 +2957,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-328
@@ -2966,7 +2966,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-329
@@ -2975,7 +2975,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-330
@@ -2984,7 +2984,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-331
@@ -2993,7 +2993,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-332
@@ -3002,7 +3002,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-333
@@ -3011,7 +3011,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-334
@@ -3020,7 +3020,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-335
@@ -3029,7 +3029,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-336
@@ -3038,7 +3038,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-337
@@ -3047,7 +3047,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-338
@@ -3056,7 +3056,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-339
@@ -3065,7 +3065,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-340
@@ -3074,7 +3074,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-341
@@ -3083,7 +3083,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-342
@@ -3092,7 +3092,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-343
@@ -3101,7 +3101,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-344
@@ -3110,7 +3110,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-345
@@ -3119,7 +3119,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-346
@@ -3128,7 +3128,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-347
@@ -3137,7 +3137,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-348
@@ -3146,7 +3146,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-349
@@ -3155,7 +3155,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-350
@@ -3164,7 +3164,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-351
@@ -3173,7 +3173,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-352
@@ -3182,7 +3182,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-353
@@ -3191,7 +3191,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-354
@@ -3200,7 +3200,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-355
@@ -3209,7 +3209,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-356
@@ -3218,7 +3218,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-357
@@ -3227,7 +3227,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-358
@@ -3236,7 +3236,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-359
@@ -3245,7 +3245,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-360
@@ -3254,7 +3254,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-361
@@ -3263,7 +3263,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-362
@@ -3272,7 +3272,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-363
@@ -3281,7 +3281,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-364
@@ -3290,7 +3290,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-365
@@ -3299,7 +3299,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-366
@@ -3308,7 +3308,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-367
@@ -3317,7 +3317,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-368
@@ -3326,7 +3326,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-369
@@ -3335,7 +3335,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-370
@@ -3344,7 +3344,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-371
@@ -3353,7 +3353,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-372
@@ -3362,7 +3362,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-373
@@ -3371,7 +3371,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem
Lines of this file are not shown. View the raw message.
The rest of this diff is not shown. View the raw message.
Signature · 1 line
2.7.4
Part of the diff is not shown here. View the raw message.
PATCH 2/3 nvme: 016: fix nvmet pass data with loop
In reply to Minwoo ImThe following commit has affected the result of genctr and treq field printed:
genctr would increment two times per a subsystem due to
Commit b662a078 ("nvmet: enable Discovery Controller AENs")
treq field would be printed out to support TP 8005:
nvmet driver:
Commit 9b95d2fb ("nvmet: expose support for fabrics SQ flow control
disable in treq")
nvme-cli:
Commit 2cf370c3 ("fabrics: support fabrics sq flow control disable")
--- tests/nvme/016.out | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
tests/nvme/016.out +2 -2
@@ -1,11 +1,11 @@ Running nvme/016 -Discovery Log Number of Records 1, Generation counter 1 +Discovery Log Number of Records 1, Generation counter 2 =====Discovery Log Entry 0====== trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-1
Signature · 1 line
2.7.4
PATCH 3/3 nvme: 017: fix nvmet pass data with loop
In reply to Minwoo ImThe following commit has affected the result of genctr and treq field printed:
genctr would increment two times per a subsystem due to
Commit b662a078 ("nvmet: enable Discovery Controller AENs")
treq field would be printed out to support TP 8005:
nvmet driver:
Commit 9b95d2fb ("nvmet: expose support for fabrics SQ flow control
disable in treq")
nvme-cli:
Commit 2cf370c3 ("fabrics: support fabrics sq flow control disable")
--- tests/nvme/017.out | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
tests/nvme/017.out +2 -2
@@ -1,11 +1,11 @@ Running nvme/017 -Discovery Log Number of Records 1, Generation counter 1 +Discovery Log Number of Records 1, Generation counter 2 =====Discovery Log Entry 0====== trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-1
Signature · 1 line
2.7.4
PATCH 1/3 nvme: 002: fix nvmet pass data with loop
In reply to Minwoo ImWe need to get rid of the string comparison here.
Quoted 9,033 lines · Minwoo Im
genctr has also incremented two times in the following two steps:
1. echo 1 > $CFG/nvmet/subsystems/$SUB/attr_allow_any_host vianvmet_subsys_attr_allow_any_host_store()
2. ln -s $CFG/nvmet/subsystems/$SUB $CFG/nvmet/port/$PORT/subsystems/ vianvmet_allowed_hosts_allow_link()genctrl updated in step 1. has been updated by the following commit:
b662a078("nvmet: enable Discovery Controller AENs")This patch makes result value to a x2 value.
it also has been a long time to have nvmet configfs with TP 8005 applied for nvmet. Commit
9b95d2fb("nvmet: expose support for fabrics SQ flow control disable in treq") supports sq flow control disabling attribute so that get log page to discovery has treq value with an updated value which has been applied by a commit2cf370c3("fabrics:
support fabrics sq flow control disable") in nvme-cli.Signed-off-by Minwoo Im <minwoo.im.dev at gmail.com>--- tests/nvme/002.out | 2002 ++++++++++++++++++++++++++-------------------------- 1 file changed, 1001 insertions(+), 1001 deletions(-)tests/nvme/002.out +1001
-1001@@ -1,11 +1,11 @@ Running nvme/002 -Discovery Log Number of Records 1000, Generation counter 1000 +Discovery Log Number of Records 1000, Generation counter 2000 =====Discovery Log Entry 0====== trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-0@@ -14,7 +14,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-1@@ -23,7 +23,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-2@@ -32,7 +32,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-3@@ -41,7 +41,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-4@@ -50,7 +50,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-5@@ -59,7 +59,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-6@@ -68,7 +68,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-7@@ -77,7 +77,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-8@@ -86,7 +86,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-9@@ -95,7 +95,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-10@@ -104,7 +104,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-11@@ -113,7 +113,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-12@@ -122,7 +122,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-13@@ -131,7 +131,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-14@@ -140,7 +140,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-15@@ -149,7 +149,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-16@@ -158,7 +158,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-17@@ -167,7 +167,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-18@@ -176,7 +176,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-19@@ -185,7 +185,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-20@@ -194,7 +194,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-21@@ -203,7 +203,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-22@@ -212,7 +212,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-23@@ -221,7 +221,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-24@@ -230,7 +230,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-25@@ -239,7 +239,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-26@@ -248,7 +248,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-27@@ -257,7 +257,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-28@@ -266,7 +266,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-29@@ -275,7 +275,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-30@@ -284,7 +284,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-31@@ -293,7 +293,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-32@@ -302,7 +302,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-33@@ -311,7 +311,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-34@@ -320,7 +320,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-35@@ -329,7 +329,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-36@@ -338,7 +338,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-37@@ -347,7 +347,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-38@@ -356,7 +356,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-39@@ -365,7 +365,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-40@@ -374,7 +374,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-41@@ -383,7 +383,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-42@@ -392,7 +392,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-43@@ -401,7 +401,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-44@@ -410,7 +410,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-45@@ -419,7 +419,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-46@@ -428,7 +428,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-47@@ -437,7 +437,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-48@@ -446,7 +446,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-49@@ -455,7 +455,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-50@@ -464,7 +464,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-51@@ -473,7 +473,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-52@@ -482,7 +482,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-53@@ -491,7 +491,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-54@@ -500,7 +500,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-55@@ -509,7 +509,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-56@@ -518,7 +518,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-57@@ -527,7 +527,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-58@@ -536,7 +536,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-59@@ -545,7 +545,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-60@@ -554,7 +554,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-61@@ -563,7 +563,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-62@@ -572,7 +572,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-63@@ -581,7 +581,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-64@@ -590,7 +590,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-65@@ -599,7 +599,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-66@@ -608,7 +608,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-67@@ -617,7 +617,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-68@@ -626,7 +626,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-69@@ -635,7 +635,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-70@@ -644,7 +644,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-71@@ -653,7 +653,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-72@@ -662,7 +662,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-73@@ -671,7 +671,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-74@@ -680,7 +680,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-75@@ -689,7 +689,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-76@@ -698,7 +698,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-77@@ -707,7 +707,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-78@@ -716,7 +716,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-79@@ -725,7 +725,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-80@@ -734,7 +734,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-81@@ -743,7 +743,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-82@@ -752,7 +752,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-83@@ -761,7 +761,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-84@@ -770,7 +770,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-85@@ -779,7 +779,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-86@@ -788,7 +788,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-87@@ -797,7 +797,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-88@@ -806,7 +806,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-89@@ -815,7 +815,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-90@@ -824,7 +824,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-91@@ -833,7 +833,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-92@@ -842,7 +842,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-93@@ -851,7 +851,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-94@@ -860,7 +860,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-95@@ -869,7 +869,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-96@@ -878,7 +878,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-97@@ -887,7 +887,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-98@@ -896,7 +896,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-99@@ -905,7 +905,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-100@@ -914,7 +914,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-101@@ -923,7 +923,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-102@@ -932,7 +932,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-103@@ -941,7 +941,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-104@@ -950,7 +950,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-105@@ -959,7 +959,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-106@@ -968,7 +968,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-107@@ -977,7 +977,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-108@@ -986,7 +986,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-109@@ -995,7 +995,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-110@@ -1004,7 +1004,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-111@@ -1013,7 +1013,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-112@@ -1022,7 +1022,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-113@@ -1031,7 +1031,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-114@@ -1040,7 +1040,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-115@@ -1049,7 +1049,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-116@@ -1058,7 +1058,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-117@@ -1067,7 +1067,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-118@@ -1076,7 +1076,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-119@@ -1085,7 +1085,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-120@@ -1094,7 +1094,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-121@@ -1103,7 +1103,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-122@@ -1112,7 +1112,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-123@@ -1121,7 +1121,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-124@@ -1130,7 +1130,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-125@@ -1139,7 +1139,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-126@@ -1148,7 +1148,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-127@@ -1157,7 +1157,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-128@@ -1166,7 +1166,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-129@@ -1175,7 +1175,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-130@@ -1184,7 +1184,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-131@@ -1193,7 +1193,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-132@@ -1202,7 +1202,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-133@@ -1211,7 +1211,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-134@@ -1220,7 +1220,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-135@@ -1229,7 +1229,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-136@@ -1238,7 +1238,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-137@@ -1247,7 +1247,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-138@@ -1256,7 +1256,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-139@@ -1265,7 +1265,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-140@@ -1274,7 +1274,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-141@@ -1283,7 +1283,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-142@@ -1292,7 +1292,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-143@@ -1301,7 +1301,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-144@@ -1310,7 +1310,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-145@@ -1319,7 +1319,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-146@@ -1328,7 +1328,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-147@@ -1337,7 +1337,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-148@@ -1346,7 +1346,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-149@@ -1355,7 +1355,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-150@@ -1364,7 +1364,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-151@@ -1373,7 +1373,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-152@@ -1382,7 +1382,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-153@@ -1391,7 +1391,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-154@@ -1400,7 +1400,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-155@@ -1409,7 +1409,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-156@@ -1418,7 +1418,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-157@@ -1427,7 +1427,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-158@@ -1436,7 +1436,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-159@@ -1445,7 +1445,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-160@@ -1454,7 +1454,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-161@@ -1463,7 +1463,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-162@@ -1472,7 +1472,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-163@@ -1481,7 +1481,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-164@@ -1490,7 +1490,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-165@@ -1499,7 +1499,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-166@@ -1508,7 +1508,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-167@@ -1517,7 +1517,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-168@@ -1526,7 +1526,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-169@@ -1535,7 +1535,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-170@@ -1544,7 +1544,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-171@@ -1553,7 +1553,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-172@@ -1562,7 +1562,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-173@@ -1571,7 +1571,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-174@@ -1580,7 +1580,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-175@@ -1589,7 +1589,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-176@@ -1598,7 +1598,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-177@@ -1607,7 +1607,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-178@@ -1616,7 +1616,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-179@@ -1625,7 +1625,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-180@@ -1634,7 +1634,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-181@@ -1643,7 +1643,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-182@@ -1652,7 +1652,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-183@@ -1661,7 +1661,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-184@@ -1670,7 +1670,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-185@@ -1679,7 +1679,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-186@@ -1688,7 +1688,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-187@@ -1697,7 +1697,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-188@@ -1706,7 +1706,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-189@@ -1715,7 +1715,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-190@@ -1724,7 +1724,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-191@@ -1733,7 +1733,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-192@@ -1742,7 +1742,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-193@@ -1751,7 +1751,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-194@@ -1760,7 +1760,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-195@@ -1769,7 +1769,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-196@@ -1778,7 +1778,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-197@@ -1787,7 +1787,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-198@@ -1796,7 +1796,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-199@@ -1805,7 +1805,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-200@@ -1814,7 +1814,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-201@@ -1823,7 +1823,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-202@@ -1832,7 +1832,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-203@@ -1841,7 +1841,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-204@@ -1850,7 +1850,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-205@@ -1859,7 +1859,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-206@@ -1868,7 +1868,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-207@@ -1877,7 +1877,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-208@@ -1886,7 +1886,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-209@@ -1895,7 +1895,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-210@@ -1904,7 +1904,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-211@@ -1913,7 +1913,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-212@@ -1922,7 +1922,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-213@@ -1931,7 +1931,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-214@@ -1940,7 +1940,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-215@@ -1949,7 +1949,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-216@@ -1958,7 +1958,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-217@@ -1967,7 +1967,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-218@@ -1976,7 +1976,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-219@@ -1985,7 +1985,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-220@@ -1994,7 +1994,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-221@@ -2003,7 +2003,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-222@@ -2012,7 +2012,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-223@@ -2021,7 +2021,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-224@@ -2030,7 +2030,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-225@@ -2039,7 +2039,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-226@@ -2048,7 +2048,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-227@@ -2057,7 +2057,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-228@@ -2066,7 +2066,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-229@@ -2075,7 +2075,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-230@@ -2084,7 +2084,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-231@@ -2093,7 +2093,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-232@@ -2102,7 +2102,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-233@@ -2111,7 +2111,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-234@@ -2120,7 +2120,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-235@@ -2129,7 +2129,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-236@@ -2138,7 +2138,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-237@@ -2147,7 +2147,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-238@@ -2156,7 +2156,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-239@@ -2165,7 +2165,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-240@@ -2174,7 +2174,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-241@@ -2183,7 +2183,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-242@@ -2192,7 +2192,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-243@@ -2201,7 +2201,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-244@@ -2210,7 +2210,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-245@@ -2219,7 +2219,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-246@@ -2228,7 +2228,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-247@@ -2237,7 +2237,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-248@@ -2246,7 +2246,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-249@@ -2255,7 +2255,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-250@@ -2264,7 +2264,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-251@@ -2273,7 +2273,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-252@@ -2282,7 +2282,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-253@@ -2291,7 +2291,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-254@@ -2300,7 +2300,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-255@@ -2309,7 +2309,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-256@@ -2318,7 +2318,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-257@@ -2327,7 +2327,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-258@@ -2336,7 +2336,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-259@@ -2345,7 +2345,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-260@@ -2354,7 +2354,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-261@@ -2363,7 +2363,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-262@@ -2372,7 +2372,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-263@@ -2381,7 +2381,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-264@@ -2390,7 +2390,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-265@@ -2399,7 +2399,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-266@@ -2408,7 +2408,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-267@@ -2417,7 +2417,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-268@@ -2426,7 +2426,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-269@@ -2435,7 +2435,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-270@@ -2444,7 +2444,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-271@@ -2453,7 +2453,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-272@@ -2462,7 +2462,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-273@@ -2471,7 +2471,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-274@@ -2480,7 +2480,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-275@@ -2489,7 +2489,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-276@@ -2498,7 +2498,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-277@@ -2507,7 +2507,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-278@@ -2516,7 +2516,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-279@@ -2525,7 +2525,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-280@@ -2534,7 +2534,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-281@@ -2543,7 +2543,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-282@@ -2552,7 +2552,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-283@@ -2561,7 +2561,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-284@@ -2570,7 +2570,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-285@@ -2579,7 +2579,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-286@@ -2588,7 +2588,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-287@@ -2597,7 +2597,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-288@@ -2606,7 +2606,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-289@@ -2615,7 +2615,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-290@@ -2624,7 +2624,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-291@@ -2633,7 +2633,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-292@@ -2642,7 +2642,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-293@@ -2651,7 +2651,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-294@@ -2660,7 +2660,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-295@@ -2669,7 +2669,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-296@@ -2678,7 +2678,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-297@@ -2687,7 +2687,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-298@@ -2696,7 +2696,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-299@@ -2705,7 +2705,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-300@@ -2714,7 +2714,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-301@@ -2723,7 +2723,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-302@@ -2732,7 +2732,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-303@@ -2741,7 +2741,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-304@@ -2750,7 +2750,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-305@@ -2759,7 +2759,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-306@@ -2768,7 +2768,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-307@@ -2777,7 +2777,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-308@@ -2786,7 +2786,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-309@@ -2795,7 +2795,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-310@@ -2804,7 +2804,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-311@@ -2813,7 +2813,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-312@@ -2822,7 +2822,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-313@@ -2831,7 +2831,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-314@@ -2840,7 +2840,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-315@@ -2849,7 +2849,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-316@@ -2858,7 +2858,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-317@@ -2867,7 +2867,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-318@@ -2876,7 +2876,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-319@@ -2885,7 +2885,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-320@@ -2894,7 +2894,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-321@@ -2903,7 +2903,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-322@@ -2912,7 +2912,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-323@@ -2921,7 +2921,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-324@@ -2930,7 +2930,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-325@@ -2939,7 +2939,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-326@@ -2948,7 +2948,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-327@@ -2957,7 +2957,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-328@@ -2966,7 +2966,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-329@@ -2975,7 +2975,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-330@@ -2984,7 +2984,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-331@@ -2993,7 +2993,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-332@@ -3002,7 +3002,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-333@@ -3011,7 +3011,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-334@@ -3020,7 +3020,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-335@@ -3029,7 +3029,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-336@@ -3038,7 +3038,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-337@@ -3047,7 +3047,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-338@@ -3056,7 +3056,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-339@@ -3065,7 +3065,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-340@@ -3074,7 +3074,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-341@@ -3083,7 +3083,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-342@@ -3092,7 +3092,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-343@@ -3101,7 +3101,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-344@@ -3110,7 +3110,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-345@@ -3119,7 +3119,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-346@@ -3128,7 +3128,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-347@@ -3137,7 +3137,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-348@@ -3146,7 +3146,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-349@@ -3155,7 +3155,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-350@@ -3164,7 +3164,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-351@@ -3173,7 +3173,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-352@@ -3182,7 +3182,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-353@@ -3191,7 +3191,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-354@@ -3200,7 +3200,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-355@@ -3209,7 +3209,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-356@@ -3218,7 +3218,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-357@@ -3227,7 +3227,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-358@@ -3236,7 +3236,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-359@@ -3245,7 +3245,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-360@@ -3254,7 +3254,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-361@@ -3263,7 +3263,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-362@@ -3272,7 +3272,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-363@@ -3281,7 +3281,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-364@@ -3290,7 +3290,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-365@@ -3299,7 +3299,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-366@@ -3308,7 +3308,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-367@@ -3317,7 +3317,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-368@@ -3326,7 +3326,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-369@@ -3335,7 +3335,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-370@@ -3344,7 +3344,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-371@@ -3353,7 +3353,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-372@@ -3362,7 +3362,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-373@@ -3371,7 +3371,7 @@ traddr: trtype: loop adrfam: pci subtype: nvme subsystemLines of this file are not shown. View the raw message.
The rest of this diff is not shown. View the raw message.
Part of the diff is not shown here. View the raw message.
Re: [PATCH 3/3] nvme: 017: fix nvmet pass data with loop
In reply to Minwoo ImWe need to get rid of the string comparison here.
Quoted 37 lines · Minwoo Im
The following commit has affected the result of genctr and treq field printed:
genctr would increment two times per a subsystem due to
Commitb662a078("nvmet: enable Discovery Controller AENs")treq field would be printed out to support TP 8005:
nvmet driver:
Commit9b95d2fb("nvmet: expose support for fabrics SQ flow control
disable in treq")
nvme-cli:
Commit2cf370c3("fabrics: support fabrics sq flow control disable")Signed-off-by Minwoo Im <minwoo.im.dev at gmail.com>--- tests/nvme/017.out | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)tests/nvme/017.out +2
-2@@ -1,11 +1,11 @@ Running nvme/017 -Discovery Log Number of Records 1, Generation counter 1 +Discovery Log Number of Records 1, Generation counter 2 =====Discovery Log Entry 0====== trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-1
Re: [PATCH 2/3] nvme: 016: fix nvmet pass data with loop
In reply to Minwoo ImWe need to get rid of the string comparison here.
Quoted 37 lines · Minwoo Im
The following commit has affected the result of genctr and treq field printed:
genctr would increment two times per a subsystem due to
Commitb662a078("nvmet: enable Discovery Controller AENs")treq field would be printed out to support TP 8005:
nvmet driver:
Commit9b95d2fb("nvmet: expose support for fabrics SQ flow control
disable in treq")
nvme-cli:
Commit2cf370c3("fabrics: support fabrics sq flow control disable")Signed-off-by Minwoo Im <minwoo.im.dev at gmail.com>--- tests/nvme/016.out | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)tests/nvme/016.out +2
-2@@ -1,11 +1,11 @@ Running nvme/016 -Discovery Log Number of Records 1, Generation counter 1 +Discovery Log Number of Records 1, Generation counter 2 =====Discovery Log Entry 0====== trtype: loop adrfam: pci subtype: nvme subsystem -treq: not specified +treq: not specified, sq flow control disable supported portid: X trsvcid: subnqn: blktests-subsystem-1
Re: [PATCH 1/3] nvme: 002: fix nvmet pass data with loop
In reply to Chaitanya KulkarniQuoted 1 line · Chaitanya Kulkarni
We need to get rid of the string comparison here.
Chaitanya,
Do you mean that test case bash script should check the result of output and return some error value instead of zero instead of *.out comparison ?
Thanks,
Re: [PATCH 1/3] nvme: 002: fix nvmet pass data with loop
Quoted 9 lines · Minwoo Im
Quoted 1 line · Chaitanya Kulkarni
We need to get rid of the string comparison here.
Chaitanya,
Do you mean that test case bash script should check the result of output and return some error value instead of zero instead of *.out comparison ?
Thanks,
We need to get rid the string comparison as much as we can e.g. in following output the nvme-cli output should not be compared but the return value itself.
-Discovery Log Number of Records 1, Generation counter 1 +Discovery Log Number of Records 1, Generation counter 2 =====Discovery Log Entry 0======
trtype: loop
adrfam: pci
subtype: nvme subsystem
-treq: not specified
+treq: not specified, sq flow control disable supported
portid: X
trsvcid:
subnqn: blktests-subsystem-1
Reason :- we cannot rely on the output as it tends to change with development which triggers fixes in blktests, unless testcase is focused on entirely on examining the output of the tool.
Re: [PATCH 1/3] nvme: 002: fix nvmet pass data with loop
Quoted 16 lines
We need to get rid the string comparison as much as we can e.g. in following output the nvme-cli output should not be compared but the return value itself.
(quoted diff) +1
-1-Discovery Log Number of Records 1, Generation counter 1 +Discovery Log Number of Records 1, Generation counter 2=====Discovery Log Entry 0======
trtype: loop
adrfam: pci
subtype: nvme subsystem(quoted diff) +1
-1-treq: not specified +treq: not specified, sq flow control disable supportedportid: X
trsvcid:
subnqn: blktests-subsystem-1
Quoted 4 lines
Reason :- we cannot rely on the output as it tends to change with development which triggers fixes in blktests, unless testcase is focused on entirely on examining the output of the tool.
Totally agree with you. nvme-cli is going to keep updated and output format might be changed which may cause test failure in blktests.
If Johannes who wrote these tests agrees to not check output result from nvme-cli, I'll get rid of them.
By the way, Checking the return value of a program like nvme-cli might not be enough to figure out what happened because this test looks like wanted to check the output of discover get log page is exactly the same with what it wanted to be in case data size is greater than 4K.
Re: [PATCH 1/3] nvme: 002: fix nvmet pass data with loop
Quoted 24 lines · Minwoo Im
Quoted 16 lines
We need to get rid the string comparison as much as we can e.g. in following output the nvme-cli output should not be compared but the return value itself.
(quoted diff) +1
-1-Discovery Log Number of Records 1, Generation counter 1 +Discovery Log Number of Records 1, Generation counter 2=====Discovery Log Entry 0======
trtype: loop
adrfam: pci
subtype: nvme subsystem(quoted diff) +1
-1-treq: not specified +treq: not specified, sq flow control disable supportedportid: X
trsvcid:
subnqn: blktests-subsystem-1Quoted 4 lines
Reason :- we cannot rely on the output as it tends to change with development which triggers fixes in blktests, unless testcase is focused on entirely on examining the output of the tool.
Totally agree with you. nvme-cli is going to keep updated and output format might be changed which may cause test failure in blktests.
Quoted 8 lines
If Johannes who wrote these tests agrees to not check output result from nvme-cli, I'll get rid of them.
By the way, Checking the return value of a program like nvme-cli might not be enough to figure out what happened because this test looks like wanted to check the output of discover get log page is exactly the same with what it wanted to be in case data size is greater than 4K.
I wasn't clear enough.
It doesn't check for the return value for now. What needs to happen is :-
1. Get rid of the variable strings which are not part of the discovery log page entries such as Generation counter.
2. Validate each log page entry content.
3. Check the return value.
We cannot *only* rely on the nvme-cli return value or on the output.
Re: [PATCH 1/3] nvme: 002: fix nvmet pass data with loop
Quoted 7 lines
I wasn't clear enough.
It doesn't check for the return value for now. What needs to happen is :-
1. Get rid of the variable strings which are not part of the discovery log page entries such as Generation counter.
2. Validate each log page entry content.
Question again here.
Do you mean that log page entry contents validation should be in bash level instead of *.out comparison?
Quoted 1 line
3. Check the return value.
nvme-cli is currently returning value like:
Quoted 1 line
0 : failed with nvme status code (but the actual value may not be
the same with status)
== 0 : done successfully
< 0 : failed with -errno
But, ( > 0) case may be removed from nvme-cli soon due to [1] discuss. Anyway, if nvme-cli is going to return 0 for both cases: success, error with nvme status, then test case is going to be hard to check the error status by a return value. It should be with output string parsing which would be great if it's going to be commonized.
Re: [PATCH 1/3] nvme: 002: fix nvmet pass data with loop
Quoted 11 lines · Minwoo Im
Quoted 7 lines
I wasn't clear enough.
It doesn't check for the return value for now. What needs to happen is :-
1. Get rid of the variable strings which are not part of the discovery log page entries such as Generation counter.
2. Validate each log page entry content.Question again here.
Do you mean that log page entry contents validation should be in bash level instead of *.out comparison?
It has *out level comparison.
Quoted 5 lines
Quoted 2 lines
3. Check the return value.
nvme-cli is currently returning value like:
Quoted 1 line
0 : failed with nvme status code (but the actual value may not be
Quoted 8 lines
the same with status)
== 0 : done successfully
< 0 : failed with -errnoBut, ( > 0) case may be removed from nvme-cli soon due to [1] discuss. Anyway, if nvme-cli is going to return 0 for both cases: success, error with nvme status, then test case is going to be hard to check the error status by a return value.
This should not happen as it will break existing scripts which are written on the top the nvme-cli in past few years.
It should be with output string parsing which
Quoted 2 lines
would be great if it's going to be commonized.
No, we cannot rely on the output string as this problem is a good example.
I'm not sure returning == 0 for error case is a good idea. Checking return value prevents us from writing unstable testcases which are bases on the text output and allow us to modify tools as specification moves forward.
Quoted 2 lines
Re: [PATCH 1/3] nvme: 002: fix nvmet pass data with loop
Quoted 8 lines
Quoted 8 lines
Quoted 7 lines
I wasn't clear enough.
It doesn't check for the return value for now. What needs to happen is :-
1. Get rid of the variable strings which are not part of the discovery log page entries such as Generation counter.
2. Validate each log page entry content.
Quoted 5 lines
Quoted 3 lines
Question again here.
Do you mean that log page entry contents validation should be in bash level instead of *.out comparison?It has *out level comparison.
I'm not sure I have got what you really meant. Please correct me if I'm wrong here ;)
First of all, removal of variable values in the result of the discovery get log page
looks great to me also. Maybe those variable values are able to be replaced a fixed value like port does (replace port value via sed command to X).
But, it also depends on the outout of the nvme-cli, not return value. Anyway, let's discuss about it with Keith also because he discussed it with me few weeks ago,I think.
Quoted 9 lines
Quoted 9 lines
Quoted 2 lines
3. Check the return value.
nvme-cli is currently returning value like:
Quoted 1 line
0 : failed with nvme status code (but the actual value may not be
the same with status)
== 0 : done successfully
< 0 : failed with -errno
Quoted 7 lines
Quoted 4 lines
But, ( > 0) case may be removed from nvme-cli soon due to [1] discuss. Anyway, if nvme-cli is going to return 0 for both cases: success, error with nvme status, then test case is going to be hard to check the error status by a return value.
This should not happen as it will break existing scripts which are written on the top the nvme-cli in past few years.
Agreed. But, please refer the following comment below ;)
Quoted 10 lines
It should be with output string parsing which
Quoted 2 lines
would be great if it's going to be commonized.
No, we cannot rely on the output string as this problem is a good example.
I'm not sure returning == 0 for error case is a good idea. Checking return value prevents us from writing unstable testcases which are bases on the text output and allow us to modify tools as specification moves forward.
Please refer a discussion on https://github.com/linux-nvme/nvme-cli/pull/489
Keith and I had a discussion about the return value of the program itself. The nvme status value is composed of 16 bits value, by the way, the actual return value of the program is in 8bits(signed) which means it's not able to carry
the actual nvme status value out of the program.
If you have any idea about it, Please let me know. By the way, I really do agree with what you mentioned about the return value. If it's possible, I would like to too :)
Quoted 4 lines
Quoted 3 lines
Re: [PATCH 1/3] nvme: 002: fix nvmet pass data with loop
Quoted 11 lines · Minwoo Im
Quoted 11 lines
Quoted 10 lines
Quoted 7 lines
I wasn't clear enough.
It doesn't check for the return value for now. What needs to happen is :-
1. Get rid of the variable strings which are not part of the discovery log page entries such as Generation counter.
2. Validate each log page entry content.Question again here.
Do you mean that log page entry contents validation should be in bash level instead of *.out comparison?It has *out level comparison.
Give me sometime I'll get back to you on this.
Quoted 49 lines
I'm not sure I have got what you really meant. Please correct me if I'm wrong here ;)
First of all, removal of variable values in the result of the discovery get log page
looks great to me also. Maybe those variable values are able to be replaced a fixed value like port does (replace port value via sed command to X).But, it also depends on the outout of the nvme-cli, not return value. Anyway, let's discuss about it with Keith also because he discussed it with me few weeks ago,I think.
Quoted 7 lines
Quoted 7 lines
Quoted 1 line
3. Check the return value.
nvme-cli is currently returning value like:
Quoted 1 line
0 : failed with nvme status code (but the actual value may not be
the same with status)
== 0 : done successfully
< 0 : failed with -errnoQuoted 6 lines
Quoted 4 lines
But, ( > 0) case may be removed from nvme-cli soon due to [1] discuss. Anyway, if nvme-cli is going to return 0 for both cases: success, error with nvme status, then test case is going to be hard to check the error status by a return value.
This should not happen as it will break existing scripts which are written on the top the nvme-cli in past few years.
Agreed. But, please refer the following comment below ;)
Quoted 9 lines
It should be with output string parsing which
Quoted 2 lines
would be great if it's going to be commonized.
No, we cannot rely on the output string as this problem is a good example.
I'm not sure returning == 0 for error case is a good idea. Checking return value prevents us from writing unstable testcases which are bases on the text output and allow us to modify tools as specification moves forward.
Please refer a discussion on https://github.com/linux-nvme/nvme-cli/pull/489
Keith and I had a discussion about the return value of the program itself. The nvme status value is composed of 16 bits value, by the way, the actual return value of the program is in 8bits(signed) which means it's not able to carry
the actual nvme status value out of the program.If you have any idea about it, Please let me know. By the way, I really do agree with what you mentioned about the return value. If it's possible, I would like to too :)
Quoted 2 lines
Quoted 2 lines
Re: [PATCH 1/3] nvme: 002: fix nvmet pass data with loop
In reply to Minwoo ImQuoted 2 lines · Minwoo Im
If Johannes who wrote these tests agrees to not check output result from nvme-cli, I'll get rid of them.
Yes agreed. In the beginning I though of validating the nvme-cli output but this would grow more and more filters, which makes it impractical.
Signature · 6 lines
Johannes Thumshirn SUSE Labs Filesystems jthumshirn at suse.de +49 911 74053 689 SUSE LINUX GmbH, Maxfeldstr. 5, 90409 N?rnberg GF: Felix Imend?rffer, Mary Higgins, Sri Rasiah HRB 21284 (AG N?rnberg) Key fingerprint = EC38 9CAB C2C4 F25D 8600 D0D0 0393 969D 2D76 0850
Re: [PATCH 1/3] nvme: 002: fix nvmet pass data with loop
Quoted 7 lines · Johannes Thumshirn
Quoted 2 lines · Minwoo Im
If Johannes who wrote these tests agrees to not check output result from nvme-cli, I'll get rid of them.
Yes agreed. In the beginning I though of validating the nvme-cli output but this would grow more and more filters, which makes it impractical.
Cool, then I think I can update the pass condition of this testcase in other way. Once Chaitanya gives his comment on this, I'll prepare it.
Thanks,
Re: [PATCH 1/3] nvme: 002: fix nvmet pass data with loop
In reply to Minwoo ImQuoted 56 lines · Minwoo Im
Quoted 8 lines
Quoted 8 lines
Quoted 7 lines
I wasn't clear enough.
It doesn't check for the return value for now. What needs to happen is :-
1. Get rid of the variable strings which are not part of the discovery log page entries such as Generation counter.
2. Validate each log page entry content.Quoted 5 lines
Quoted 3 lines
Question again here.
Do you mean that log page entry contents validation should be in bash level instead of *.out comparison?It has *out level comparison.
I'm not sure I have got what you really meant. Please correct me if I'm wrong here ;)
First of all, removal of variable values in the result of the discovery get log page
looks great to me also. Maybe those variable values are able to be replaced a fixed value like port does (replace port value via sed command to X).But, it also depends on the outout of the nvme-cli, not return value. Anyway, let's discuss about it with Keith also because he discussed it with me few weeks ago,I think.
Quoted 9 lines
Quoted 9 lines
Quoted 2 lines
3. Check the return value.
nvme-cli is currently returning value like:
> 0 : failed with nvme status code (but the actual value may not be
the same with status)
== 0 : done successfully
< 0 : failed with -errnoQuoted 7 lines
Quoted 4 lines
But, ( > 0) case may be removed from nvme-cli soon due to [1] discuss. Anyway, if nvme-cli is going to return 0 for both cases: success, error with nvme status, then test case is going to be hard to check the error status by a return value.
This should not happen as it will break existing scripts which are written on the top the nvme-cli in past few years.
Agreed. But, please refer the following comment below ;)
Quoted 10 lines
It should be with output string parsing which
Quoted 2 lines
would be great if it's going to be commonized.
No, we cannot rely on the output string as this problem is a good example.
I'm not sure returning == 0 for error case is a good idea. Checking return value prevents us from writing unstable testcases which are bases on the text output and allow us to modify tools as specification moves forward.
Quoted 6 lines
Please refer a discussion on https://github.com/linux-nvme/nvme-cli/pull/489
Keith and I had a discussion about the return value of the program itself. The nvme status value is composed of 16 bits value, by the way, the actual return value of the program is in 8bits(signed) which means it's not able to carry
the actual nvme status value out of the program.
Isn't this unsigned ? as pointed out by Keith ?
$ cat a.c
int main(void)
{
return -1;
}
$ gcc a.c -o a
$ ./a
$ echo $?
255May be I'm missing something here ?
Quoted 4 lines
If you have any idea about it, Please let me know. By the way, I really do agree with what you mentioned about the return value. If it's possible, I would like to too :)
How about we instead of returning the NVMe Status we map the NVMe Status of the program to the error code and in-turn return that error code ?
The above is true only when command is successfully submitted from the program i.e. no errno is set by any library calls and failed in the completion queue entry with NVMe Status != NVME_SC_SUCCESS.
For your reference In kernel we already do this detailed mapping where :-
1. Please refer to the drivers/nvme/target/core.c file where we map the errno_to_nvme_status(), the reverse mapping of that function can be done with nvme_status_to_errno(). Of course you will have to add more cases and do in-detail reverse error mapping from NVMe status to errno and return that errno.
2. nvme_error_status() we map NVMe Status to block layer status.
3. blk_status_to_errno() we map the block layer status to the errno.
With the help of 1, 2 and 3 you can reverse map the NVMe Status to errno and add that mapper function for nvme-cli which will be consistent with the kernel NVMe status to errno mapping.
Now you might find some cases where you cannot map all the status codes to errno and for those default cases you may end up using something like EIO, this is still better way than having to return 0.
Quoted 6 lines
Quoted 5 lines
Quoted 4 lines
Re: [PATCH 1/3] nvme: 002: fix nvmet pass data with loop
In reply to Minwoo ImQuoted 5 lines · Minwoo Im
Quoted 4 lines · Johannes Thumshirn
Quoted 2 lines · Minwoo Im
If Johannes who wrote these tests agrees to not check output result from nvme-cli, I'll get rid of them.
Quoted 7 lines
Quoted 3 lines
Yes agreed. In the beginning I though of validating the nvme-cli output but this would grow more and more filters, which makes it impractical.
Cool, then I think I can update the pass condition of this testcase in other way. Once Chaitanya gives his comment on this, I'll prepare it.
I think responded to this one.
Quoted 2 lines
Thanks,
Re: [PATCH 1/3] nvme: 002: fix nvmet pass data with loop
In reply to Chaitanya KulkarniQuoted 12 lines
Isn't this unsigned ? as pointed out by Keith ?
$ cat a.c int main(void) { return -1; } $ gcc a.c -o a $ ./a $ echo $? 255
Quoted 1 line
May be I'm missing something here ?
I meant that the program returns in a signed value, but it's going to be parsed in 8bits which is unix style, I think. Sorry for being unclear. That's not enough to hold nvme status value at all.
Quoted 22 lines
Quoted 4 lines
If you have any idea about it, Please let me know. By the way, I really do agree with what you mentioned about the return value. If it's possible, I would like to too :)
How about we instead of returning the NVMe Status we map the NVMe Status of the program to the error code and in-turn return that error code ?
The above is true only when command is successfully submitted from the program i.e. no errno is set by any library calls and failed in the completion queue entry with NVMe Status !=
NVME_SC_SUCCESS.For your reference In kernel we already do this detailed mapping where :-
1. Please refer to the
drivers/nvme/target/core.cfile where we map theerrno_to_nvme_status(), the reverse mapping of that function can be done withnvme_status_to_errno(). Of course you will have to add more cases and do in-detail reverse error mapping from NVMe status to errno and return that errno.
2.nvme_error_status()we map NVMe Status to block layer status.
3.blk_status_to_errno()we map the block layer status to the errno.
Quoted 7 lines
With the help of 1, 2 and 3 you can reverse map the NVMe Status to errno and add that mapper function for nvme-cli which will be consistent with the kernel NVMe status to errno mapping.
Now you might find some cases where you cannot map all the status codes to errno and for those default cases you may end up using something like EIO, this is still better way than having to return 0.
Got your point. To make this discussion short, I think we need to make it in nvme-cli first. Let me have a discussion on the following link:
https://github.com/linux-nvme/nvme-cli/pull/492
Thanks,