thermal: brcmstb: enable hwmon
PATCH 1/1 thermal: brcmstb: enable hwmon
From: Chen-Yu Tsai <[email protected]>
By defaul of-based thermal driver do not have hwmon entries registered.
Do this explicitly so users can use standard hwmon interfaces and tools to read the temperature.
This is based on similar changes for bcm2835_thermal in commit d56c19d07e0b ("thermal: bcm2835: enable hwmon explicitly").
---
This patch was only compile tested. A similar patch [1] was submitted to the downstream kernel, which I did build and actually run on a Raspberry Pi 4.
This one for mainline is much simpler, as it does not need to deal with the error path or device removal, due to the use of devres.
[1] https://github.com/raspberrypi/linux/pull/3307
--- drivers/thermal/broadcom/brcmstb_thermal.c | 8 ++++++++ 1 file changed, 8 insertions(+)
drivers/thermal/broadcom/brcmstb_thermal.c +8 -0
@@ -21,6 +21,8 @@#include <linux/of_device.h> #include <linux/thermal.h> +#include "../thermal_hwmon.h" +#define AVS_TMON_STATUS 0x00#define AVS_TMON_STATUS_valid_msk BIT(11)#define AVS_TMON_STATUS_data_msk GENMASK(10, 1)
@@ -343,6 +345,12 @@ static int brcmstb_thermal_probe(struct platform_device *pdev)return ret; } +/* hwmon not enabled by default. Enable it here. */ + thermal->tzp->no_hwmon = false; + ret =thermal_add_hwmon_sysfs (thermal); +if (ret) +return ret; +dev_info (&pdev->dev,"registered AVS TMON of-sensor driver\n" );return 0 ;
Signature · 1 line
2.20.1
Hi Chen-Yu,
Quoted 11 lines · Chen-Yu Tsai
From: Chen-Yu Tsai <[email protected]>
By defaul of-based thermal driver do not have hwmon entries registered.
Do this explicitly so users can use standard hwmon interfaces and tools to read the temperature.
This is based on similar changes for
bcm2835_thermalin commitd56c19d07e0b("thermal: bcm2835: enable hwmon explicitly").Signed-off-by Chen-Yu Tsai <[email protected]>
There a number of patches that I need to get upstream from our downstream tree, because right now the temperatures reported are note quite in the expected units..
Signature · 1 line
Florian
Quoted 13 lines · Florian Fainelli
Hi Chen-Yu,
Quoted 10 lines · Chen-Yu Tsai
From: Chen-Yu Tsai <[email protected]>
By defaul of-based thermal driver do not have hwmon entries registered.
Do this explicitly so users can use standard hwmon interfaces and tools to read the temperature.
This is based on similar changes for
bcm2835_thermalin commitd56c19d07e0b("thermal: bcm2835: enable hwmon explicitly").
Quoted 7 lines
Quoted 1 line
Signed-off-by Chen-Yu Tsai <[email protected]>Tested-by Florian Fainelli <[email protected]>There a number of patches that I need to get upstream from our downstream tree, because right now the temperatures reported are note quite in the expected units..
Oh yes, because we call the standard thermal framework helpers to extract the coefficients, and we never made that a mandatory property, so our firmware does not provide that information and the raw DAC code is not properly converted, will fix that as well.
Signature · 1 line
Florian
Hi Chen-Yu,
Am 30.10.19 um 17:38 schrieb Chen-Yu Tsai:
Quoted 10 lines
From: Chen-Yu Tsai <[email protected]>
By defaul of-based thermal driver do not have hwmon entries registered.
Do this explicitly so users can use standard hwmon interfaces and tools to read the temperature.
This is based on similar changes for
bcm2835_thermalin commitd56c19d07e0b("thermal: bcm2835: enable hwmon explicitly").
Quoted 6 lines
Signed-off-by Chen-Yu Tsai <[email protected]>---
This patch was only compile tested. A similar patch [1] was submitted to the downstream kernel, which I did build and actually run on a Raspberry Pi 4.
just a note: from my understanding [2] the brcmstb_thermal isn't the right driver for BCM2711. Please consider the current downstream solution for BCM2711 support as a quick hack to avoid writing a new thermal driver. But must confess that i didn't test Florian's recent changes yet.
Regards
Stefan
[2] -
https://github.com/raspberrypi/linux/issues/3101#issuecomment-527554223
Quoted 9 lines
This one for mainline is much simpler, as it does not need to deal with the error path or device removal, due to the use of devres.
[1] https://github.com/raspberrypi/linux/pull/3307
--- drivers/thermal/broadcom/brcmstb_thermal.c | 8 ++++++++ 1 file changed, 8 insertions(+)
_______________________________________________
linux-arm-kernel mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel
Quoted 20 lines · Stefan Wahren
Hi Chen-Yu,
Am 30.10.19 um 17:38 schrieb Chen-Yu Tsai:
Quoted 10 lines
From: Chen-Yu Tsai <[email protected]>
By defaul of-based thermal driver do not have hwmon entries registered.
Do this explicitly so users can use standard hwmon interfaces and tools to read the temperature.
This is based on similar changes for
bcm2835_thermalin commitd56c19d07e0b("thermal: bcm2835: enable hwmon explicitly").Quoted 6 lines
Signed-off-by Chen-Yu Tsai <[email protected]>---
This patch was only compile tested. A similar patch [1] was submitted to the downstream kernel, which I did build and actually run on a Raspberry Pi 4.
Quoted 5 lines
just a note: from my understanding [2] the
brcmstb_thermalisn't the right driver for BCM2711. Please consider the current downstream solution for BCM2711 support as a quick hack to avoid writing a new thermal driver. But must confess that i didn't test Florian's recent changes yet.
The brcmstb_thermal driver is for chips with an AVS_TMON whereas the 2711 does not have it AFAICT, even if the registers are there, the hardware is not present (or so have I been told).
The AVS_RO register you are being pointed out may work, although the data is over 10 bits (not 11) and the valid bit is 10 (not 11). It looks like you may have to check bit 16 as well for a measurement being done or not.
Signature · 1 line
Florian
Quoted 21 lines · Stefan Wahren
Hi Chen-Yu,
Am 30.10.19 um 17:38 schrieb Chen-Yu Tsai:
Quoted 10 lines
From: Chen-Yu Tsai <[email protected]>
By defaul of-based thermal driver do not have hwmon entries registered.
Do this explicitly so users can use standard hwmon interfaces and tools to read the temperature.
This is based on similar changes for
bcm2835_thermalin commitd56c19d07e0b("thermal: bcm2835: enable hwmon explicitly").Quoted 6 lines
Signed-off-by Chen-Yu Tsai <[email protected]>---
This patch was only compile tested. A similar patch [1] was submitted to the downstream kernel, which I did build and actually run on a Raspberry Pi 4.
Quoted 5 lines
just a note: from my understanding [2] the
brcmstb_thermalisn't the right driver for BCM2711. Please consider the current downstream solution for BCM2711 support as a quick hack to avoid writing a new thermal driver. But must confess that i didn't test Florian's recent changes yet.
Thanks for the tip. I only saw the thread after posting this patch.
ChenYu
Quoted 16 lines
Regards
Stefan[2] -
https://github.com/raspberrypi/linux/issues/3101#issuecomment-527554223Quoted 9 lines
This one for mainline is much simpler, as it does not need to deal with the error path or device removal, due to the use of devres.
[1] https://github.com/raspberrypi/linux/pull/3307
--- drivers/thermal/broadcom/brcmstb_thermal.c | 8 ++++++++ 1 file changed, 8 insertions(+)