Hi all,

On my system (Raspberry PI 3), the RX path doesn't work anymore following a restart of the bluetooth-meshd daemon. I have tracked down that to the fact that the receive callbacks are setup before the HCI is fully initialized. Said otherwise, BT_HCI_CMD_LE_SET_SCAN_PARAMETERS is called before BT_HCI_CMD_RESET and the callback calling BT_HCI_CMD_LE_SET_SCAN_ENABLE is not called. This timing dependent and probably not reproducible on all hardware.

I have workarounded the issue by adding a small delay between the HCI initialization and the call to node_attach_io_all():

mesh/mesh.c +4 -0
index 9b2b2073b..1c06060f9 100644
@@ -167,6 +167,10 @@ bool mesh_init(const char *config_dir, enum mesh_io_type type, void *opts)
 	mesh_io_get_caps(mesh.io, &caps);
 	mesh.max_filters = caps.max_num_filters;
 
+	for (int i = 0 ; i < 100 ; i++) {
+		l_main_iterate(10);
+	}
+
 	node_attach_io_all(mesh.io);
 
 	return true;

I guess there is a better way to do that by waiting for the HCI to be fully initialized before calling node_attach_io_all() or by using a callback instead. However I do not know the codebase good enough to fix that properly.

Aurelien

Signature · 2 lines
Aurelien Jarno                          GPG: 4096R/1DDD8C9B
[email protected]                 http://www.aurel32.net
#1 lore raw
Quoted 34 lines · Aurelien Jarno

Hi all,

On my system (Raspberry PI 3), the RX path doesn't work anymore following a restart of the bluetooth-meshd daemon. I have tracked down
that to the fact that the receive callbacks are setup before the HCI is
fully initialized. Said otherwise, BT_HCI_CMD_LE_SET_SCAN_PARAMETERS is
called before BT_HCI_CMD_RESET and the callback calling BT_HCI_CMD_LE_SET_SCAN_ENABLE is not called. This timing dependent and
probably not reproducible on all hardware.

I have workarounded the issue by adding a small delay between the HCI initialization and the call to node_attach_io_all():

mesh/mesh.c +4 -0
index 9b2b2073b..1c06060f9 100644
@@ -167,6 +167,10 @@ bool mesh_init(const char *config_dir, enum
 mesh_io_type type, void *opts)
 	mesh_io_get_caps(mesh.io, &caps);
 	mesh.max_filters = caps.max_num_filters;
 
+	for (int i = 0 ; i < 100 ; i++) {
+		l_main_iterate(10);
+	}
+
 	node_attach_io_all(mesh.io);
 

return true;

Quoted 8 lines

I guess there is a better way to do that by waiting for the HCI to be fully initialized before calling node_attach_io_all() or by using a callback instead. However I do not know the codebase good enough to fix
that properly.

Aurelien

I've experienced something similar on my rpi3. I found that on restart, discover-unprovisioned stopped working.

In my case, it appears that meshd assumes that if there are existing nodes, scanning has been enabled. Thus, calls from mesh-cfgclient to discover additional unprovisioned nodes do not need another hci scan enable at mesh/mesh-io-generic.c:736.

If meshd is restarted with preexisting nodes, scanning is still assumed to already be enabled, but it's not. This breaks discover-unprovisioned for me.

I suspect this is a symptom of a deeper problem where mesh/mesh-config- json.c:load_node doesn't completely reestablish the node state that existed when the node was originally added.

Steve

#2 lore raw

Hi,

Quoted 41 lines · Steve Brown
Quoted 40 lines · Aurelien Jarno

Hi all,

On my system (Raspberry PI 3), the RX path doesn't work anymore following a restart of the bluetooth-meshd daemon. I have tracked down
that to the fact that the receive callbacks are setup before the HCI is
fully initialized. Said otherwise, BT_HCI_CMD_LE_SET_SCAN_PARAMETERS is
called before BT_HCI_CMD_RESET and the callback calling BT_HCI_CMD_LE_SET_SCAN_ENABLE is not called. This timing dependent and
probably not reproducible on all hardware.

I have workarounded the issue by adding a small delay between the HCI initialization and the call to node_attach_io_all():

mesh/mesh.c +4 -0
index 9b2b2073b..1c06060f9 100644
@@ -167,6 +167,10 @@ bool mesh_init(const char *config_dir, enum
 mesh_io_type type, void *opts)
 	mesh_io_get_caps(mesh.io, &caps);
 	mesh.max_filters = caps.max_num_filters;
 
+	for (int i = 0 ; i < 100 ; i++) {
+		l_main_iterate(10);
+	}
+
 	node_attach_io_all(mesh.io);
 

return true;

I guess there is a better way to do that by waiting for the HCI to be fully initialized before calling node_attach_io_all() or by using a callback instead. However I do not know the codebase good enough to fix
that properly.

Quoted 4 lines
Quoted 2 lines

Aurelien

I've experienced something similar on my rpi3. I found that on restart, discover-unprovisioned stopped working.

In my case I also observe the same.

Quoted 8 lines

In my case, it appears that meshd assumes that if there are existing nodes, scanning has been enabled. Thus, calls from mesh-cfgclient to discover additional unprovisioned nodes do not need another hci scan enable at mesh/mesh-io-generic.c:736.

If meshd is restarted with preexisting nodes, scanning is still assumed to already be enabled, but it's not. This breaks discover-unprovisioned for me.

Yes, I think this is exactly my problem. If there are existing nodes, recv_register is called before the HCI is configured and pvt->rx_regs is filled at mesh/mesh-io-generic.c:738. This means that later scanning is assumed to be enabled. However the call to bt_hci_send with BT_HCI_CMD_LE_SET_SCAN_PARAMETERS fails as the HCI is not yet initialized and the callback set_recv_scan_enable() supposed to enable scanning is not called.

So when loading a node, scanning is assumed to be enabled, but it is not practice.

I believe my workaround should work on your system (maybe after adjusting the number of iterations of the loop).

Aurelien

Signature · 2 lines
Aurelien Jarno                          GPG: 4096R/1DDD8C9B
[email protected]                 http://www.aurel32.net
#3 lore raw

Hi Aurelien,

Quoted 68 lines · Aurelien Jarno

Hi,

Quoted 41 lines · Steve Brown
Quoted 40 lines · Aurelien Jarno

Hi all,

On my system (Raspberry PI 3), the RX path doesn't work anymore following a restart of the bluetooth-meshd daemon. I have tracked down
that to the fact that the receive callbacks are setup before the HCI is
fully initialized. Said otherwise, BT_HCI_CMD_LE_SET_SCAN_PARAMETERS is
called before BT_HCI_CMD_RESET and the callback calling BT_HCI_CMD_LE_SET_SCAN_ENABLE is not called. This timing dependent and
probably not reproducible on all hardware.

I have workarounded the issue by adding a small delay between the HCI initialization and the call to node_attach_io_all():

mesh/mesh.c +4 -0
index 9b2b2073b..1c06060f9 100644
@@ -167,6 +167,10 @@ bool mesh_init(const char *config_dir, enum
 mesh_io_type type, void *opts)
 	mesh_io_get_caps(mesh.io, &caps);
 	mesh.max_filters = caps.max_num_filters;
 
+	for (int i = 0 ; i < 100 ; i++) {
+		l_main_iterate(10);
+	}
+
 	node_attach_io_all(mesh.io);
 

return true;

I guess there is a better way to do that by waiting for the HCI to be fully initialized before calling node_attach_io_all() or by using a callback instead. However I do not know the codebase good enough to fix
that properly.

Quoted 4 lines
Quoted 2 lines

Aurelien

I've experienced something similar on my rpi3. I found that on restart, discover-unprovisioned stopped working.

In my case I also observe the same.

Quoted 8 lines

In my case, it appears that meshd assumes that if there are existing nodes, scanning has been enabled. Thus, calls from mesh-cfgclient to discover additional unprovisioned nodes do not need another hci scan enable at mesh/mesh-io-generic.c:736.

If meshd is restarted with preexisting nodes, scanning is still assumed to already be enabled, but it's not. This breaks discover-unprovisioned for me.

Yes, I think this is exactly my problem. If there are existing nodes, recv_register is called before the HCI is configured and pvt->rx_regs is filled at mesh/mesh-io-generic.c:738. This means that later scanning is assumed to be enabled. However the call to bt_hci_send with BT_HCI_CMD_LE_SET_SCAN_PARAMETERS fails as the HCI is not yet initialized and the callback set_recv_scan_enable() supposed to enable scanning is not called.

Quoted 8 lines

So when loading a node, scanning is assumed to be enabled, but it is not practice.

I believe my workaround should work on your system (maybe after adjusting the number of iterations of the loop).

Aurelien

Thanks for the analysis. I think we should switch to callback approach, i.e. initialize io first and register the RX on the successful init callback.

Best regards,
Inga