tools/mesh-cfgclient: add unbind command
PATCH 1/1 tools/mesh-cfgclient: add unbind command
This is basically a copy of cmd_bind with OP_MODEL_APP_BIND replaced by OP_MODEL_APP_UNBIND as cmds[] already has code to handle it.
--- tools/mesh/cfgcli.c | 36 ++++++++++++++++++++++++++++++++++++ 1 file changed, 36 insertions(+)
tools/mesh/cfgcli.c +36 -0
@@ -897,6 +897,40 @@ static void cmd_bind(int argc, char *argv[])return bt_shell_noninteractive_quit (EXIT_SUCCESS ); } +static void cmd_unbind (int argc,char *argv[]) +{ +uint16_t n; +uint8_t msg[32 ]; +int parm_cnt; + + parm_cnt =read_input_parameters (argc, argv); +if (parm_cnt !=3 && parm_cnt !=4 ) { +bt_shell_printf ("Bad arguments\n" ); +return bt_shell_noninteractive_quit (EXIT_FAILURE ); + } + + n =mesh_opcode_set (OP_MODEL_APP_UNBIND , msg); + +put_le16 (parms[0 ], msg + n); + n +=2 ; +put_le16 (parms[1 ], msg + n); + n +=2 ; + +if (parm_cnt ==4 ) { +put_le16 (parms[3 ], msg + n); +put_le16 (parms[2 ], msg + n +2 ); + n +=4 ; + }else { +put_le16 (parms[2 ], msg + n); + n +=2 ; + } + +if (!config_send (msg, n,OP_MODEL_APP_UNBIND )) +return bt_shell_noninteractive_quit (EXIT_FAILURE ); + +return bt_shell_noninteractive_quit (EXIT_SUCCESS ); +} +static void cmd_beacon_set (int argc,char *argv[]) {uint16_t n;
@@ -1335,6 +1369,8 @@ static const struct bt_shell_menu cfg_menu = { "Delete application key"}, {"bind" ,"<ele_addr> <app_idx> <mod_id> [vendor_id]" , cmd_bind, "Bind app key to a model"}, + {"unbind", "<ele_addr> <app_idx> <mod_id> [vendor_id]", cmd_unbind, + "Remove app key from a model"}, {"mod-appidx-get", "<ele_addr> <model id>", cmd_mod_appidx_get, "Get model app_idx"}, {"ttl-set", "<ttl>", cmd_ttl_set,
Signature · 1 line
2.24.0
Hi Aurelien,
Quoted 37 lines · Aurelien Jarno
This is basically a copy of
cmd_bindwithOP_MODEL_APP_BINDreplaced byOP_MODEL_APP_UNBINDas cmds[] already has code to handle it.--- tools/mesh/cfgcli.c | 36 ++++++++++++++++++++++++++++++++++++ 1 file changed, 36 insertions(+)tools/mesh/cfgcli.c +23
-0@@ -897,6 +897,40 @@ static void cmd_bind(int argc, char *argv[])return bt_shell_noninteractive_quit (EXIT_SUCCESS ); } +static void cmd_unbind (int argc,char *argv[]) +{ +uint16_t n; +uint8_t msg[32 ]; +int parm_cnt; + + parm_cnt =read_input_parameters (argc, argv); +if (parm_cnt !=3 && parm_cnt !=4 ) { +bt_shell_printf ("Bad arguments\n" ); +return bt_shell_noninteractive_quit (EXIT_FAILURE ); + } + + n =mesh_opcode_set (OP_MODEL_APP_UNBIND , msg); + +put_le16 (parms[0 ], msg + n); + n +=2 ; +put_le16 (parms[1 ], msg + n); + n +=2 ; + +if (parm_cnt ==4 ) { +put_le16 (parms[3 ], msg + n); +put_le16 (parms[2 ], msg + n +2 ); + n +=4 ;
tools/mesh/cfgcli.c static void cmd_bind(int argc, char *argv[]) · line 932
Quoted 10 lines
tools/mesh/cfgcli.c +10
-0+ }else { +put_le16 (parms[2 ], msg + n); + n +=2 ; + } + +if (!config_send (msg, n,OP_MODEL_APP_UNBIND )) +return bt_shell_noninteractive_quit (EXIT_FAILURE ); + +return bt_shell_noninteractive_quit (EXIT_SUCCESS ); +}
Since cmd_bind() & and cmd_unbind()
are virtually identical with the exception of the opcode, let's combine them to call one routine, e.g.cmd_add_binding() and cmd delete_binding() would call cmd_bind(int argc, char*argv[], int opcode)
tools/mesh/cfgcli.c static const struct bt_shell_menu cfg_menu = { · line 1376
Quoted 13 lines
tools/mesh/cfgcli.c +3
-0+static void cmd_beacon_set (int argc,char *argv[]) {uint16_t n;@@ -1335,6 +1369,8 @@ static const struct bt_shell_menu cfg_menu = { "Delete application key"}, {"bind" ,"<ele_addr> <app_idx> <mod_id> [vendor_id]" , cmd_bind, "Bind app key to a model"}, + {"unbind", "<ele_addr> <app_idx> <mod_id> [vendor_id]", cmd_unbind, + "Remove app key from a model"}, {"mod-appidx-get", "<ele_addr> <model id>", cmd_mod_appidx_get, "Get model app_idx"}, {"ttl-set", "<ttl>", cmd_ttl_set,
Best regards,
Inga
Gix, Brian
AppliedApplied, Thanks
Quoted 60 lines · Aurelien Jarno
This is basically a copy of
cmd_bindwithOP_MODEL_APP_BINDreplaced byOP_MODEL_APP_UNBINDas cmds[] already has code to handle it.--- tools/mesh/cfgcli.c | 36 ++++++++++++++++++++++++++++++++++++ 1 file changed, 36 insertions(+)tools/mesh/cfgcli.c +36
-0@@ -897,6 +897,40 @@ static void cmd_bind(int argc, char *argv[])return bt_shell_noninteractive_quit (EXIT_SUCCESS ); } +static void cmd_unbind (int argc,char *argv[]) +{ +uint16_t n; +uint8_t msg[32 ]; +int parm_cnt; + + parm_cnt =read_input_parameters (argc, argv); +if (parm_cnt !=3 && parm_cnt !=4 ) { +bt_shell_printf ("Bad arguments\n" ); +return bt_shell_noninteractive_quit (EXIT_FAILURE ); + } + + n =mesh_opcode_set (OP_MODEL_APP_UNBIND , msg); + +put_le16 (parms[0 ], msg + n); + n +=2 ; +put_le16 (parms[1 ], msg + n); + n +=2 ; + +if (parm_cnt ==4 ) { +put_le16 (parms[3 ], msg + n); +put_le16 (parms[2 ], msg + n +2 ); + n +=4 ; + }else { +put_le16 (parms[2 ], msg + n); + n +=2 ; + } + +if (!config_send (msg, n,OP_MODEL_APP_UNBIND )) +return bt_shell_noninteractive_quit (EXIT_FAILURE ); + +return bt_shell_noninteractive_quit (EXIT_SUCCESS ); +} +static void cmd_beacon_set (int argc,char *argv[]) {uint16_t n;@@ -1335,6 +1369,8 @@ static const struct bt_shell_menu cfg_menu = { "Delete application key"}, {"bind" ,"<ele_addr> <app_idx> <mod_id> [vendor_id]" , cmd_bind, "Bind app key to a model"}, + {"unbind", "<ele_addr> <app_idx> <mod_id> [vendor_id]", cmd_unbind, + "Remove app key from a model"}, {"mod-appidx-get", "<ele_addr> <model id>", cmd_mod_appidx_get, "Get model app_idx"}, {"ttl-set", "<ttl>", cmd_ttl_set,
Actually applied v2 of this patch
Quoted 63 lines · Brian
Applied, Thanks
Quoted 60 lines · Aurelien Jarno
This is basically a copy of
cmd_bindwithOP_MODEL_APP_BINDreplaced byOP_MODEL_APP_UNBINDas cmds[] already has code to handle it.--- tools/mesh/cfgcli.c | 36 ++++++++++++++++++++++++++++++++++++ 1 file changed, 36 insertions(+)tools/mesh/cfgcli.c +36
-0@@ -897,6 +897,40 @@ static void cmd_bind(int argc, char *argv[])return bt_shell_noninteractive_quit (EXIT_SUCCESS ); } +static void cmd_unbind (int argc,char *argv[]) +{ +uint16_t n; +uint8_t msg[32 ]; +int parm_cnt; + + parm_cnt =read_input_parameters (argc, argv); +if (parm_cnt !=3 && parm_cnt !=4 ) { +bt_shell_printf ("Bad arguments\n" ); +return bt_shell_noninteractive_quit (EXIT_FAILURE ); + } + + n =mesh_opcode_set (OP_MODEL_APP_UNBIND , msg); + +put_le16 (parms[0 ], msg + n); + n +=2 ; +put_le16 (parms[1 ], msg + n); + n +=2 ; + +if (parm_cnt ==4 ) { +put_le16 (parms[3 ], msg + n); +put_le16 (parms[2 ], msg + n +2 ); + n +=4 ; + }else { +put_le16 (parms[2 ], msg + n); + n +=2 ; + } + +if (!config_send (msg, n,OP_MODEL_APP_UNBIND )) +return bt_shell_noninteractive_quit (EXIT_FAILURE ); + +return bt_shell_noninteractive_quit (EXIT_SUCCESS ); +} +static void cmd_beacon_set (int argc,char *argv[]) {uint16_t n;@@ -1335,6 +1369,8 @@ static const struct bt_shell_menu cfg_menu = { "Delete application key"}, {"bind" ,"<ele_addr> <app_idx> <mod_id> [vendor_id]" , cmd_bind, "Bind app key to a model"}, + {"unbind", "<ele_addr> <app_idx> <mod_id> [vendor_id]", cmd_unbind, + "Remove app key from a model"}, {"mod-appidx-get", "<ele_addr> <model id>", cmd_mod_appidx_get, "Get model app_idx"}, {"ttl-set", "<ttl>", cmd_ttl_set,