igc: Add PHY power management control
Subsystems (2)
PATCH 1/1 igc: Add PHY power management control
PHY power management control should provide a reliable and accurate indication of PHY reset completion and decrease the delay time after a PHY reset
--- drivers/net/ethernet/intel/igc/igc_defines.h | 1 + drivers/net/ethernet/intel/igc/igc_phy.c | 9 +++++++++ drivers/net/ethernet/intel/igc/igc_regs.h | 1 + 3 files changed, 11 insertions(+)
drivers/net/ethernet/intel/igc/igc_defines.h +1 -0
@@ -460,6 +460,7 @@/* PHY Status Register */ #define MII_SR_LINK_STATUS 0x0004/* Link Status 1 = link */ #define MII_SR_AUTONEG_COMPLETE 0x0020/* Auto Neg Complete */ +#define IGC_PHY_RST_COMP 0x0100/* Internal PHY reset completion */ /* PHY 1000 MII Register/Bit Definitions */ /* PHY Registers defined by IEEE */
drivers/net/ethernet/intel/igc/igc_phy.c +9 -0
@@ -173,6 +173,7 @@ s32 igc_check_downshift(struct igc_hw *hw)s32 igc_phy_hw_reset (struct igc_hw *hw) {struct igc_phy_info *phy = &hw->phy; +u32 phpm =0 , timeout =10000 ;s32 ret_val;u32 ctrl;
@@ -186,6 +187,8 @@ s32 igc_phy_hw_reset(struct igc_hw *hw)if (ret_val) goto out; + phpm =rd32 (IGC_I225_PHPM ); + ctrl =rd32 (IGC_CTRL );wr32 (IGC_CTRL , ctrl |IGC_CTRL_PHY_RST );wrfl ();
@@ -195,6 +198,12 @@ s32 igc_phy_hw_reset(struct igc_hw *hw)wr32 (IGC_CTRL , ctrl);wrfl (); +do { + phpm =rd32 (IGC_I225_PHPM ); + timeout--; +udelay (1 ); + }while (!(phpm &IGC_PHY_RST_COMP ) && timeout); +usleep_range (1500 ,2000 ); phy->ops.release (hw);
drivers/net/ethernet/intel/igc/igc_regs.h +1 -0
@@ -12,6 +12,7 @@#define IGC_MDIC 0x00020/* MDI Control - RW */ #define IGC_MDICNFG 0x00E04/* MDC/MDIO Configuration - RW */ #define IGC_CONNSW 0x00034/* Copper/Fiber switch control - RW */ +#define IGC_I225_PHPM 0x00E14/* I225 PHY Power Management */ /* Internal Packet Buffer Size Registers */ #define IGC_RXPBS 0x02404/* Rx Packet Buffer Size - RW */
Signature · 1 line
2.11.0
PATCH 1/1 igc: Add PHY power management control
Dear Sasha,
Quoted 28 lines · Sasha Neftin
PHY power management control should provide a reliable and accurate indication of PHY reset completion and decrease the delay time after a PHY reset
Signed-off-by Sasha Neftin <[email protected]>--- drivers/net/ethernet/intel/igc/igc_defines.h | 1 + drivers/net/ethernet/intel/igc/igc_phy.c | 9 +++++++++ drivers/net/ethernet/intel/igc/igc_regs.h | 1 + 3 files changed, 11 insertions(+)drivers/net/ethernet/intel/igc/igc_defines.h +1
-0@@ -460,6 +460,7 @@/* PHY Status Register */ #define MII_SR_LINK_STATUS 0x0004/* Link Status 1 = link */ #define MII_SR_AUTONEG_COMPLETE 0x0020/* Auto Neg Complete */ +#define IGC_PHY_RST_COMP 0x0100/* Internal PHY reset completion */ /* PHY 1000 MII Register/Bit Definitions */ /* PHY Registers defined by IEEE */ drivers/net/ethernet/intel/igc/igc_phy.c +0
-0
drivers/net/ethernet/intel/igc/igc_phy.c s32 igc_check_downshift(struct igc_hw *hw) · line 176
Quoted 4 lines
drivers/net/ethernet/intel/igc/igc_phy.c +1
-0@@ -173,6 +173,7 @@ s32 igc_check_downshift(struct igc_hw *hw)s32 igc_phy_hw_reset (struct igc_hw *hw) {struct igc_phy_info *phy = &hw->phy; +u32 phpm =0 , timeout =10000 ;
Just use unsigned int for timeout?
phpm does not need to be initialized to 0?
Quoted 13 lines
drivers/net/ethernet/intel/igc/igc_phy.c +2
-0s32 ret_val;u32 ctrl;@@ -186,6 +187,8 @@ s32 igc_phy_hw_reset(struct igc_hw *hw)if (ret_val) goto out; + phpm =rd32 (IGC_I225_PHPM ); + ctrl =rd32 (IGC_CTRL );wr32 (IGC_CTRL , ctrl |IGC_CTRL_PHY_RST );wrfl ();
drivers/net/ethernet/intel/igc/igc_phy.c s32 igc_phy_hw_reset(struct igc_hw *hw) · line 205
Quoted 8 lines
drivers/net/ethernet/intel/igc/igc_phy.c +5
-0@@ -195,6 +198,12 @@ s32 igc_phy_hw_reset(struct igc_hw *hw)wr32 (IGC_CTRL , ctrl);wrfl (); +do { + phpm =rd32 (IGC_I225_PHPM ); + timeout--; +udelay (1 ); + }while (!(phpm &IGC_PHY_RST_COMP ) && timeout);
Print an error, when the timeout is reached?
Quoted 10 lines
drivers/net/ethernet/intel/igc/igc_phy.c +1
-0+usleep_range (1500 ,2000 ); phy->ops.release (hw);drivers/net/ethernet/intel/igc/igc_regs.h +0
-0
drivers/net/ethernet/intel/igc/igc_regs.h line 18
Quoted 7 lines
drivers/net/ethernet/intel/igc/igc_regs.h +1
-0@@ -12,6 +12,7 @@#define IGC_MDIC 0x00020/* MDI Control - RW */ #define IGC_MDICNFG 0x00E04/* MDC/MDIO Configuration - RW */ #define IGC_CONNSW 0x00034/* Copper/Fiber switch control - RW */ +#define IGC_I225_PHPM 0x00E14/* I225 PHY Power Management */ /* Internal Packet Buffer Size Registers */ #define IGC_RXPBS 0x02404/* Rx Packet Buffer Size - RW */
-------------- next part --------------
A non-text attachment was scrubbed...
Name: smime.p7s
Type: application/pkcs7-signature
Size: 5174 bytes
Desc: S/MIME Cryptographic Signature
URL: <http://lists.osuosl.org/pipermail/intel-wired-lan/attachments/20191212/7d592b74/attachment.p7s>
Neftin
PATCH 1/1 igc: Add PHY power management control
Quoted 25 lines · Paul Menzel
Dear Sasha,
Quoted 21 lines · Sasha Neftin
PHY power management control should provide a reliable and accurate indication of PHY reset completion and decrease the delay time after a PHY reset
Signed-off-by Sasha Neftin <[email protected]>--- drivers/net/ethernet/intel/igc/igc_defines.h | 1 + drivers/net/ethernet/intel/igc/igc_phy.c | 9 +++++++++ drivers/net/ethernet/intel/igc/igc_regs.h | 1 + 3 files changed, 11 insertions(+)drivers/net/ethernet/intel/igc/igc_defines.h +1
-0@@ -460,6 +460,7 @@/* PHY Status Register */ #define MII_SR_LINK_STATUS 0x0004/* Link Status 1 = link */ #define MII_SR_AUTONEG_COMPLETE 0x0020/* Auto Neg Complete */ +#define IGC_PHY_RST_COMP 0x0100/* Internal PHY reset completion */
Quoted 14 lines
drivers/net/ethernet/intel/igc/igc_phy.c s32 igc_check_downshift(struct igc_hw *hw) · line 176
Quoted 11 lines
drivers/net/ethernet/intel/igc/igc_defines.h +0
-0/* PHY 1000 MII Register/Bit Definitions */ /* PHY Registers defined by IEEE */ drivers/net/ethernet/intel/igc/igc_phy.c +1
-0@@ -173,6 +173,7 @@ s32 igc_check_downshift(struct igc_hw *hw)s32 igc_phy_hw_reset (struct igc_hw *hw) {struct igc_phy_info *phy = &hw->phy; +u32 phpm =0 , timeout =10000 ;Just use
unsigned intfortimeout?
u32 is unsigned int.
Quoted 1 line
phpm does not need to be initialized to 0?
RST_COMP indication in the PHPM register is clear on reading. I once 'read' the PHPM before polling and make sure zero value.
Quoted 17 lines
Quoted 17 lines
drivers/net/ethernet/intel/igc/igc_phy.c +2
-0s32 ret_val;u32 ctrl;@@ -186,6 +187,8 @@ s32 igc_phy_hw_reset(struct igc_hw *hw)if (ret_val) goto out; + phpm =rd32 (IGC_I225_PHPM ); + ctrl =rd32 (IGC_CTRL );wr32 (IGC_CTRL , ctrl |IGC_CTRL_PHY_RST );wrfl ();@@ -195,6 +198,12 @@ s32 igc_phy_hw_reset(struct igc_hw *hw)wr32 (IGC_CTRL , ctrl);wrfl ();
Quoted 7 lines
drivers/net/ethernet/intel/igc/igc_phy.c s32 igc_phy_hw_reset(struct igc_hw *hw) · line 205
Quoted 5 lines
drivers/net/ethernet/intel/igc/igc_phy.c +5
-0+do { + phpm =rd32 (IGC_I225_PHPM ); + timeout--; +udelay (1 ); + }while (!(phpm &IGC_PHY_RST_COMP ) && timeout);Print an error, when the timeout is reached?
Good idea. I will add hw_dbg in v2. Thanks.
Quoted 15 lines
Quoted 15 lines
drivers/net/ethernet/intel/igc/igc_phy.c +1
-0+usleep_range (1500 ,2000 ); phy->ops.release (hw);drivers/net/ethernet/intel/igc/igc_regs.h +1
-0@@ -12,6 +12,7 @@#define IGC_MDIC 0x00020/* MDI Control - RW */ #define IGC_MDICNFG 0x00E04/* MDC/MDIO Configuration - RW */ #define IGC_CONNSW 0x00034/* Copper/Fiber switch control - RW */ +#define IGC_I225_PHPM 0x00E14/* I225 PHY Power Management */
Quoted 4 lines
drivers/net/ethernet/intel/igc/igc_regs.h line 18
Quoted 3 lines
drivers/net/ethernet/intel/igc/igc_regs.h +0
-0/* Internal Packet Buffer Size Registers */ #define IGC_RXPBS 0x02404/* Rx Packet Buffer Size - RW */
Hello Paul,
Thank you very much for your comments.
Sasha
PATCH 1/1 igc: Add PHY power management control
Dear Sasha,
Am 12.12.19 um 13:08 schrieb Neftin, Sasha:
Quoted 39 lines · Paul Menzel
Quoted 29 lines · Sasha Neftin
Quoted 27 lines
PHY power management control should provide a reliable and accurate indication of PHY reset completion and decrease the delay time after a PHY reset
Signed-off-by Sasha Neftin <[email protected]>---
? drivers/net/ethernet/intel/igc/igc_defines.h | 1 + ? drivers/net/ethernet/intel/igc/igc_phy.c???? | 9 +++++++++ ? drivers/net/ethernet/intel/igc/igc_regs.h??? | 1 +? 3 files changed, 11 insertions(+)
drivers/net/ethernet/intel/igc/igc_defines.h +0
-0@@ -460,6 +460,7 @@? /* PHY Status Register */
? #defineMII_SR_LINK_STATUS???0x0004/* Link Status 1 = link */ ? #defineMII_SR_AUTONEG_COMPLETE???0x0020/* Auto Neg Complete */ +#defineIGC_PHY_RST_COMP???0x0100/* Internal PHY reset completion */ ? /* PHY 1000 MII Register/Bit Definitions */
? /* PHY Registers defined by IEEE */drivers/net/ethernet/intel/igc/igc_phy.c +0
-1--- a/drivers/net/ethernet/intel/igc/igc_phy.cQuoted 9 lines
drivers/net/ethernet/intel/igc/igc_phy.c s32 igc_check_downshift(struct igc_hw *hw) · line 176
Quoted 6 lines
+++
b/drivers/net/ethernet/intel/igc/igc_phy.cdrivers/net/ethernet/intel/igc/igc_phy.c +1
-0@@ -173,6 +173,7 @@ s32 igc_check_downshift(struct igc_hw *hw) ? s32 igc_phy_hw_reset(struct igc_hw *hw) ? { ????? struct igc_phy_info *phy = &hw->phy; +??? u32 phpm = 0, timeout = 10000;Just use
unsigned intfortimeout?
Quoted 1 line
u32 is unsigned int.
Yeah, but you constrain the size. Why not use the native type for the given architecture? It won?t be noticeable in size and speed, but it?s more cleaner.
Quoted 3 lines
Quoted 1 line
phpm does not need to be initialized to 0?
RST_COMPindication in the PHPM register is clear on reading. I once 'read' the PHPM before polling and make sure zero value.
Sorry, I do not understand. I suggest to just declare the variable.
u32 phpm;
Quoted 6 lines
Quoted 6 lines
drivers/net/ethernet/intel/igc/igc_phy.c s32 igc_phy_hw_reset(struct igc_hw *hw) · line 189
Quoted 6 lines
drivers/net/ethernet/intel/igc/igc_phy.c +1
-0????? s32? ret_val; ????? u32 ctrl;@@ -186,6 +187,8 @@ s32 igc_phy_hw_reset(struct igc_hw *hw) ????? if (ret_val) ????????? goto out; +??? phpm = rd32(IGC_I225_PHPM);
Here you are making sure, that it?s set.
Quoted 27 lines
Quoted 6 lines
Quoted 6 lines
drivers/net/ethernet/intel/igc/igc_phy.c +1
-0+ ????? ctrl = rd32(IGC_CTRL); ????? wr32(IGC_CTRL, ctrl | IGC_CTRL_PHY_RST); ????? wrfl();@@ -195,6 +198,12 @@ s32 igc_phy_hw_reset(struct igc_hw *hw) ????? wr32(IGC_CTRL, ctrl);Quoted 8 lines
drivers/net/ethernet/intel/igc/igc_phy.c s32 igc_phy_hw_reset(struct igc_hw *hw) · line 204
Quoted 6 lines
drivers/net/ethernet/intel/igc/igc_phy.c +5
-0????? wrfl(); +??? do { +??????? phpm = rd32(IGC_I225_PHPM); +??????? timeout--; +??????? udelay(1); +??? } while (!(phpm & IGC_PHY_RST_COMP) && timeout);Print an error, when the timeout is reached?
Good idea. I will add
hw_dbgin v2. Thanks.Quoted 12 lines
Quoted 12 lines
drivers/net/ethernet/intel/igc/igc_phy.c +1
-0+ ????? usleep_range(1500, 2000); ????? phy->ops.release(hw);drivers/net/ethernet/intel/igc/igc_regs.h +0
-0@@ -12,6 +12,7 @@? #define
IGC_MDIC???????0x00020? /* MDI Control - RW */
? #defineIGC_MDICNFG???????0x00E04? /* MDC/MDIO Configuration - RW */
Quoted 8 lines
Quoted 6 lines
Quoted 6 lines
? #define
IGC_CONNSW???????0x00034? /* Copper/Fiber switch control - RW */
+#defineIGC_I225_PHPM???????0x00E14???? /* I225 PHY Power Management */
? /* Internal Packet Buffer Size Registers */
? #defineIGC_RXPBS???????0x02404? /* Rx Packet Buffer Size - RW */Thank you very much for your comments.
No problem. Thank you for the commits.
Kind regards,
Paul