RDMA/rxe: Set sys_image_guid to be aligned with HW IB devices
Subsystems (2)
PATCH 1/1 RDMA/rxe: Set sys_image_guid to be aligned with HW IB devices
From: Zhu Yanjun <[email protected]>
The RXE driver doesn't set sys_image_guid and user space applications see zeros. This causes to pyverbs tests to fail with the following traceback, because the IBTA spec requires to have valid sys_image_guid.
Traceback (most recent call last):
File "./tests/test_device.py", line 51, in test_query_device
self.verify_device_attr(attr)
File "./tests/test_device.py", line 74, in verify_device_attr
assert attr.sys_image_guid != 0
In order to fix it, set sys_image_guid to be equal to node_guid.
Before:
5: rxe0: ... node_guid 5054:00ff:feaa:5363 sys_image_guid 0000:0000:0000:0000
After:
5: rxe0: ... node_guid 5054:00ff:feaa:5363 sys_image_guid 5054:00ff:feaa:5363
Fixes 8700e3e7c485 ("Soft RoCE driver")
Signed-off-by Zhu Yanjun <[email protected]>
Signed-off-by Leon Romanovsky <[email protected]>
--- drivers/infiniband/sw/rxe/rxe.c | 2 ++ 1 file changed, 2 insertions(+)
drivers/infiniband/sw/rxe/rxe.c +2 -0
@@ -103,6 +103,8 @@ static void rxe_init_device_param(struct rxe_dev *rxe) rxe->attr.max_fast_reg_page_list_len =RXE_MAX_FMR_PAGE_LIST_LEN ; rxe->attr.max_pkeys =RXE_MAX_PKEYS ; rxe->attr.local_ca_ack_delay =RXE_LOCAL_CA_ACK_DELAY ; +addrconf_addr_eui48 ((unsigned char *)&rxe->attr.sys_image_guid, + rxe->ndev->dev_addr); rxe->max_ucontext =RXE_MAX_UCONTEXT ; }
Signature · 1 line
2.24.1