thinkpad_acpi: Add support for dual fan control on select models

PATCH Andy Shevchenko 4 participants 7 messages Apr 24, 2020 – May 1, 2020 9 messages not in the archive x86 platform drivers

lore
Share & tools
lore
#3 lore raw
In reply to a message not in the archive
Quoted 16 lines · Lars

This adds dual fan control for the following models:
P50, P51, P52, P70, P71, P72, P1 gen1, X1E gen1, P2 gen2, and X1E gen2.

Both fans are controlled together as if they were a single fan.

Tested on an X1 Extreme Gen1, an X1 Extreme Gen2, and a P50.

The patch is defensive, it adds only specific supported machines, and falls back to the old behavior if both fans cannot be controlled.

Background:
I tested the BIOS default behavior on my X1E gen2 and both fans are always changed together. So rather than adding controls for each fan, this controls both fans together as the BIOS would do.

Quoted 8 lines

This was inspired by a discussion on dual fan support for the thinkfan tool [1].
All BIOS ids are taken from there. The X1E gen2 id is verified on my machine.

Thanks to GitHub users voidworker and civic9 for the earlier patches and BIOS ids, and to users peter-stoll and sassman for testing the patch on their machines.

Pushed to my review and testing queue, thank you!

Quoted 107 lines

[1]: https://github.com/vmatare/thinkfan/issues/58

---
 drivers/platform/x86/thinkpad_acpi.c | 43 ++++++++++++++++++++++++----
 1 file changed, 37 insertions(+), 6 deletions(-)
drivers/platform/x86/thinkpad_acpi.c +37 -7
index da794dcfdd92..9e0f65e567be 100644
@@ -318,6 +318,7 @@ static struct {
        u32 uwb:1;
        u32 fan_ctrl_status_undef:1;
        u32 second_fan:1;
+       u32 second_fan_ctl:1;
        u32 beep_needs_two_args:1;
        u32 mixer_no_level_control:1;
        u32 battery_force_primary:1;
@@ -8325,11 +8326,19 @@ static int fan_set_level(int level)
 
        switch (fan_control_access_mode) {
        case TPACPI_FAN_WR_ACPI_SFAN:
-               if (level >= 0 && level <= 7) {
-                       if (!acpi_evalf(sfan_handle, NULL, NULL, "vd", level))
-                               return -EIO;
-               } else
+               if ((level < 0) || (level > 7))
                        return -EINVAL;
+
+               if (tp_features.second_fan_ctl) {
+                       if (!fan_select_fan2() ||
+                           !acpi_evalf(sfan_handle, NULL, NULL, "vd", level)) {
+                               pr_warn("Couldn't set 2nd fan level, disabling support\n");
+                               tp_features.second_fan_ctl = 0;
+                       }
+                       fan_select_fan1();
+               }
+               if (!acpi_evalf(sfan_handle, NULL, NULL, "vd", level))
+                       return -EIO;
                break;
 
        case TPACPI_FAN_WR_ACPI_FANS:
@@ -8346,6 +8355,15 @@ static int fan_set_level(int level)
                else if (level & TP_EC_FAN_AUTO)
                        level |= 4;     /* safety min speed 4 */
 
+               if (tp_features.second_fan_ctl) {
+                       if (!fan_select_fan2() ||
+                           !acpi_ec_write(fan_status_offset, level)) {
+                               pr_warn("Couldn't set 2nd fan level, disabling support\n");
+                               tp_features.second_fan_ctl = 0;
+                       }
+                       fan_select_fan1();
+
+               }
                if (!acpi_ec_write(fan_status_offset, level))
                        return -EIO;
                else
@@ -8764,6 +8782,7 @@ static const struct attribute_group fan_attr_group = {
 
 #define TPACPI_FAN_Q1  0x0001          /* Unitialized HFSP */
 #define TPACPI_FAN_2FAN        0x0002          /* EC 0x31 bit 0 selects fan2 */
+#define TPACPI_FAN_2CTL        0x0004          /* selects fan2 control */
 
 static const struct tpacpi_quirk fan_quirk_table[] __initconst = {
        TPACPI_QEC_IBM('1', 'Y', TPACPI_FAN_Q1),
@@ -8772,6 +8791,13 @@ static const struct tpacpi_quirk fan_quirk_table[] __initconst = {
        TPACPI_QEC_IBM('7', '0', TPACPI_FAN_Q1),
        TPACPI_QEC_LNV('7', 'M', TPACPI_FAN_2FAN),
        TPACPI_Q_LNV('N', '1', TPACPI_FAN_2FAN),
+       TPACPI_Q_LNV3('N', '1', 'D', TPACPI_FAN_2CTL),  /* P70 */
+       TPACPI_Q_LNV3('N', '1', 'E', TPACPI_FAN_2CTL),  /* P50 */
+       TPACPI_Q_LNV3('N', '1', 'T', TPACPI_FAN_2CTL),  /* P71 */
+       TPACPI_Q_LNV3('N', '1', 'U', TPACPI_FAN_2CTL),  /* P51 */
+       TPACPI_Q_LNV3('N', '2', 'C', TPACPI_FAN_2CTL),  /* P52 / P72 */
+       TPACPI_Q_LNV3('N', '2', 'E', TPACPI_FAN_2CTL),  /* P1 / X1 Extreme (1st gen) */
+       TPACPI_Q_LNV3('N', '2', 'O', TPACPI_FAN_2CTL),  /* P1 / X1 Extreme (2nd gen) */
 };
 
 static int __init fan_init(struct ibm_init_struct *iibm)
@@ -8789,6 +8815,7 @@ static int __init fan_init(struct ibm_init_struct *iibm)
        fan_watchdog_maxinterval = 0;
        tp_features.fan_ctrl_status_undef = 0;
        tp_features.second_fan = 0;
+       tp_features.second_fan_ctl = 0;
        fan_control_desired_level = 7;
 
        if (tpacpi_is_ibm()) {
@@ -8813,8 +8840,12 @@ static int __init fan_init(struct ibm_init_struct *iibm)
                                fan_quirk1_setup();
                        if (quirks & TPACPI_FAN_2FAN) {
                                tp_features.second_fan = 1;
-                               dbg_printk(TPACPI_DBG_INIT | TPACPI_DBG_FAN,
-                                       "secondary fan support enabled\n");
+                               pr_info("secondary fan support enabled\n");
+                       }
+                       if (quirks & TPACPI_FAN_2CTL) {
+                               tp_features.second_fan = 1;
+                               tp_features.second_fan_ctl = 1;
+                               pr_info("secondary fan control enabled\n");
                        }
                } else {
                        pr_err("ThinkPad ACPI EC access misbehaving, fan status and control unavailable\n");
--

2.25.3

Signature · 2 lines
With Best Regards,
Andy Shevchenko
#4 lore raw
In reply to a message not in the archive
Quoted 20 lines · Lars

This adds dual fan control for the following models:
P50, P51, P52, P70, P71, P72, P1 gen1, X1E gen1, P2 gen2, and X1E gen2.

Both fans are controlled together as if they were a single fan.

Tested on an X1 Extreme Gen1, an X1 Extreme Gen2, and a P50.

The patch is defensive, it adds only specific supported machines, and falls back to the old behavior if both fans cannot be controlled.

Background:
I tested the BIOS default behavior on my X1E gen2 and both fans are always changed together. So rather than adding controls for each fan, this controls both fans together as the BIOS would do.

This was inspired by a discussion on dual fan support for the thinkfan tool [1].
All BIOS ids are taken from there. The X1E gen2 id is verified on my machine.

Quoted 7 lines

Thanks to GitHub users voidworker and civic9 for the earlier patches and BIOS ids, and to users peter-stoll and sassman for testing the patch on their machines.

[1]: https://github.com/vmatare/thinkfan/issues/58

One question though, is Lars your real name here? [1]

[1]: https://www.kernel.org/doc/html/latest/process/submitting-patches.html#sign-your-work-the-developer-s-certificate-of-origin

Signature · 2 lines
With Best Regards,
Andy Shevchenko
#7 lore raw
In reply to a message not in the archive
Quoted 10 lines · On Mon, Apr 27, 2020 at 10:44 AM [email protected]…

Hi Andy,

my full name is Lars Hofhansl.
Should I send a new post?

Just in case, I hereby:

No need for this one, I will update locally, thanks!

Quoted 48 lines

-- Lars

On Friday, April 24, 2020, 4:12:05 AM PDT, Andy Shevchenko <[email protected]> wrote:

Quoted 20 lines · Lars

This adds dual fan control for the following models:
P50, P51, P52, P70, P71, P72, P1 gen1, X1E gen1, P2 gen2, and X1E gen2.

Both fans are controlled together as if they were a single fan.

Tested on an X1 Extreme Gen1, an X1 Extreme Gen2, and a P50.

The patch is defensive, it adds only specific supported machines, and falls back to the old behavior if both fans cannot be controlled.

Background:
I tested the BIOS default behavior on my X1E gen2 and both fans are always changed together. So rather than adding controls for each fan, this controls both fans together as the BIOS would do.

This was inspired by a discussion on dual fan support for the thinkfan tool [1].
All BIOS ids are taken from there. The X1E gen2 id is verified on my machine.

Quoted 7 lines

Thanks to GitHub users voidworker and civic9 for the earlier patches and BIOS ids, and to users peter-stoll and sassman for testing the patch on their machines.

[1]: https://github.com/vmatare/thinkfan/issues/58

One question though, is Lars your real name here? [1]

[1]:
https://www.kernel.org/doc/html/latest/process/submitting-patches.html#sign-your-work-the-developer-s-certificate-of-origin

--
With Best Regards,
Andy Shevchenko

Signature · 2 lines
With Best Regards,
Andy Shevchenko
#8 lore raw
In reply to a message not in the archive
Quoted 9 lines · Lars

This adds dual fan control for the following models:
P50, P51, P52, P70, P71, P72, P1 gen1, X1E gen1, P2 gen2, and X1E gen2.

Both fans are controlled together as if they were a single fan. [...]
Background:
I tested the BIOS default behavior on my X1E gen2 and both fans are always changed together. So rather than adding controls for each fan, this controls both fans together as the BIOS would do.

Hi Lars, why have you chosen to control multiple fans in this way? I know that BIOS controls both fans together, but the EC has the capabilities to control both fans independently, so maybe it can be convenient to expose this feature.

Distinti saluti/Best regards,
Dario Messina

#9 lore raw

pon., 27 kwi 2020 o 20:41 Dario Messina <[email protected]> napisał(a):

Quoted 11 lines · Lars
Quoted 9 lines

This adds dual fan control for the following models:
P50, P51, P52, P70, P71, P72, P1 gen1, X1E gen1, P2 gen2, and X1E gen2.

Both fans are controlled together as if they were a single fan. [...]
Background:
I tested the BIOS default behavior on my X1E gen2 and both fans are always changed together. So rather than adding controls for each fan, this controls both fans together as the BIOS would do.

Quoted 4 lines

Hi Lars, why have you chosen to control multiple fans in this way? I know that BIOS controls both fans together, but the EC has the capabilities to control both fans independently, so maybe it can be convenient to expose this feature.

+1
Previous version of the patch [1] allows to control both fans independently. However some software like thinkfan is not ready to control two fans. But I also think this feature should be at least optionally exposed.

[1] https://github.com/civic9/thinkpad_acpi.2ndfan.patch/blob/master/thinkpad_acpi.2ndfan.patch/thinkpad_acpi.2ndfan.patch

_______________________________________________
ibm-acpi-devel mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/ibm-acpi-devel

#13 lore raw
In reply to a message not in the archive
Quoted 6 lines · Stefan Assmann
Quoted 5 lines · On 29.04.20 02:20, [email protected] wrote:

Do you have a use case for that behavior?

The previous patch broke the /proc interface, didn't not work with the current version of thinkfan (but a a version with multi-fan support is in the works), and it had hard to track internal mutable state.

Quoted 6 lines
Quoted 3 lines

The proposed change is clean on all these fronts.

I'm not a fan of surprising the user with unnecessarily complex behavior (but perhaps this can be added as an option in the future.)

I concur to keep the patch as is. Any additional functionality could be added later on, if deemed necessary.

Yes, but let's avoid changing exposed APIs as much as possible...

Anyway, the correct interface *when exposing both fans* is:

1. Use the "hwmon" sysfs interface to expose each fan separately, and control them separately.

1a. it is quite acceptable to control them in group by default, and have a module parameter to select grouped, or separate behavior.

2. /proc/acpi/ibm/fan shall control both of them at the same time, and report data from the first fan. THIS INTERFACE IS FROZEN, LET'S NOT MESS WITH IT.

Also, "fail-safe" for this is to have the two fans on automatic, and to enable both fans.

All of that said, *it is very much acceptable* to merge a first set of patches that controls both fans simultaneously and exposes the fan group as if it were just the main fan, and later improve on the patch to expose the second fan separately (provided safe group behavior is maintained, see above).

Signature · 1 line
  Henrique Holschuh
#15 lore raw
In reply to a message not in the archive

śr., 29 kwi 2020 o 02:21 [email protected] <[email protected]> napisał(a):

Quoted 2 lines

Do you have a use case for that behavior?

I work very often with just one fan enabled at the lowest level. It is inaudible for me and it does its job for not too heavy usage. If the second one is also enabled I can hear them. We love Linux for such small extra features too.

_______________________________________________