i40e: Add support for a new feature: Total Port Shutdown
Subsystems (2)
PATCH v3 1/1 i40e: Add support for a new feature: Total Port Shutdown
After OS requests to down a link on a physical network port, the traffic is no longer being processed but the physical link with a link partner is still established.
Currently there is a feature (Link down on close) which allows to physically bring the link down (after OS request).
With this patch new feature with similar capability is introduced:TOTAL_PORT_SHUTDOWN
Allows to physically disable the link on the NIC's port. If enabled, (after link down request from the OS)
no link, traffic or led activity is possible on that port.
If I40E_FLAG_TOTAL_PORT_SHUTDOWN is enabled, the I40E_FLAG_LINK_DOWN_ON_CLOSE_ENABLED must be explicitly forced to true and cannot be disabled at that time.
The functionalities are exclusive in terms of configuration, but they also have similar behavior (allowing to disable physical link of the port), with following differences:
- LINK_DOWN_ON_CLOSE_ENABLED is configurable at host OS run-time and is supported by whole family of 7xx Intel Ethernet Controllers
- TOTAL_PORT_SHUTDOWN may be enabled only before OS loads (in BIOS) only if motherboard's BIOS and NIC's FW has support of it
- when LINK_DOWN_ON_CLOSE_ENABLED is used, the link is being brought down by sending phy_type=0 to NIC's FW
- when TOTAL_PORT_SHUTDOWN is used, phy_type is not altered, instead the link is being brought down by clearing bit (I40E_AQ_PHY_ENABLE_LINK) in abilities field of i40e_aq_set_phy_config structure
Introduced changes:
- new private flag I40E_FLAG_TOTAL_PORT_SHUTDOWN for handling the feature
- probe of NVM if the feature was enabled at driver's port initialization
- special handling on link-down procedure to let FW physically shutdown the port if the feature was enabled
---
v3:
- error messages changed
- '_ENABLED' suffix in a new private flag name
- new comment for documentation of a new private flag
- rewrite commit message
--- Cut off before submitting to external review --- Testing Hints (required if no HSD):
Link up/down, link-down-on-close
Change-Id: I5427227c31b5e2d30f1149ad8d27d475caa27241
Title: i40e: Add support for a new feature: Total Port Shutdown
Change-type: FeatureImplementation
HSDES-Number: 2209979406
HSDES-Tenant: server_platf_lan.bug
--- drivers/net/ethernet/intel/i40e/i40e.h | 22 ++++ .../net/ethernet/intel/i40e/i40e_ethtool.c | 9 ++ drivers/net/ethernet/intel/i40e/i40e_main.c | 124 +++++++++++++++--- 3 files changed, 134 insertions(+), 21 deletions(-)
drivers/net/ethernet/intel/i40e/i40e.h +22 -0
@@ -567,6 +567,28 @@ struct i40e_pf {#define I40E_FLAG_DISABLE_FW_LLDP BIT(24)#define I40E_FLAG_RS_FEC BIT(25)#define I40E_FLAG_BASE_R_FEC BIT(26) +/* TOTAL_PORT_SHUTDOWN +* Allows to physically disable the link on the NIC's port. +* If enabled, (after link down request from the OS) +* no link, traffic or led activity is possible on that port. +* +* If I40E_FLAG_TOTAL_PORT_SHUTDOWN_ENABLED is set, the +* I40E_FLAG_LINK_DOWN_ON_CLOSE_ENABLED must be explicitly forced to true +* and cannot be disabled by system admin at that time. +* The functionalities are exclusive in terms of configuration, but they also +* have similar behavior (allowing to disable physical link of the port), +* with following differences: +* - LINK_DOWN_ON_CLOSE_ENABLED is configurable at host OS run-time and is +* supported by whole family of 7xx Intel Ethernet Controllers +* - TOTAL_PORT_SHUTDOWN may be enabled only before OS loads (in BIOS) +* only if motherboard's BIOS and NIC's FW has support of it +* - when LINK_DOWN_ON_CLOSE_ENABLED is used, the link is being brought down +* by sending phy_type=0 to NIC's FW +* - when TOTAL_PORT_SHUTDOWN is used, phy_type is not altered, instead +* the link is being brought down by clearing bit (I40E_AQ_PHY_ENABLE_LINK) +* in abilities field of i40e_aq_set_phy_config structure +*/ +#define I40E_FLAG_TOTAL_PORT_SHUTDOWN_ENABLED BIT(27)struct i40e_client_instance *cinst;bool stat_offsets_loaded;
drivers/net/ethernet/intel/i40e/i40e_ethtool.c +9 -0
@@ -428,6 +428,8 @@ struct i40e_priv_flags {static const struct i40e_priv_flags i40e_gstrings_priv_flags[] = {/* NOTE: MFP setting cannot be changed */ I40E_PRIV_FLAG ("MFP" ,I40E_FLAG_MFP_ENABLED ,1 ), +I40E_PRIV_FLAG ("total-port-shutdown" , +I40E_FLAG_TOTAL_PORT_SHUTDOWN_ENABLED ,1 ),I40E_PRIV_FLAG ("LinkPolling" ,I40E_FLAG_LINK_POLLING_ENABLED ,0 ),I40E_PRIV_FLAG ("flow-director-atr" ,I40E_FLAG_FD_ATR_ENABLED ,0 ),I40E_PRIV_FLAG ("veb-stats" ,I40E_FLAG_VEB_STATS_ENABLED ,0 ),
@@ -5006,6 +5008,13 @@ static int i40e_set_priv_flags(struct net_device *dev, u32 flags)dev_warn (&pf->pdev->dev,"Cannot change FEC config\n" ); } +if ((changed_flags &I40E_FLAG_LINK_DOWN_ON_CLOSE_ENABLED ) && + (orig_flags &I40E_FLAG_TOTAL_PORT_SHUTDOWN_ENABLED )) { +dev_err (&pf->pdev->dev, +"Setting link-down-on-close not supported on this port (because total-port-shutdown is enabled)\n" ); +return -EOPNOTSUPP ; + } +if ((changed_flags & new_flags &I40E_FLAG_LINK_DOWN_ON_CLOSE_ENABLED ) && (new_flags &I40E_FLAG_MFP_ENABLED ))
drivers/net/ethernet/intel/i40e/i40e_main.c +103 -21
185 lines not on this page · raw message
Signature · 7 lines
2.26.0 --------------------------------------------------------------------- Intel Technology Poland sp. z o.o. ul. Sowackiego 173 | 80-298 Gdask | Sd Rejonowy Gdask Pnoc | VII Wydzia Gospodarczy Krajowego Rejestru Sdowego - KRS 101882 | NIP 957-07-52-316 | Kapita zakadowy 200.000 PLN. Ta wiadomo wraz z zacznikami jest przeznaczona dla okrelonego adresata i moe zawiera informacje poufne. W razie przypadkowego otrzymania tej wiadomoci, prosimy o powiadomienie nadawcy oraz trwae jej usunicie; jakiekolwiek przegldanie lub rozpowszechnianie jest zabronione. This e-mail and any attachments may contain confidential material for the sole use of the intended recipient(s). If you are not the intended recipient, please contact the sender and delete all copies; any review or distribution by others is strictly prohibited.
Bowers
PATCH v3 1/1 i40e: Add support for a new feature: Total Port Shutdown
Quoted 65 lines
-----Original Message-----
From: Intel-wired-lan <[email protected]> On Behalf Of Arkadiusz Kubalewski
Sent: Tuesday, June 16, 2020 5:06 PM
To: intel-wired-lan at lists.osuosl.org
Cc: Loktionov, Aleksandr <[email protected]>
Subject: [Intel-wired-lan] [PATCH v3] i40e: Add support for a new feature:
Total Port ShutdownAfter OS requests to down a link on a physical network port, the traffic is no longer being processed but the physical link with a link partner is still established.
Currently there is a feature (Link down on close) which allows to physically bring the link down (after OS request).
With this patch new feature with similar capability is introduced:
TOTAL_PORT_SHUTDOWN
Allows to physically disable the link on the NIC's port.
If enabled, (after link down request from the OS) no link, traffic or led activity is possible on that port.If
I40E_FLAG_TOTAL_PORT_SHUTDOWNis enabled, theI40E_FLAG_LINK_DOWN_ON_CLOSE_ENABLEDmust be explicitly forced to true and cannot be disabled at that time.
The functionalities are exclusive in terms of configuration, but they also have similar behavior (allowing to disable physical link of the port), with following differences:
-LINK_DOWN_ON_CLOSE_ENABLEDis configurable at host OS run-time and is supported by whole family of 7xx Intel Ethernet Controllers
-TOTAL_PORT_SHUTDOWNmay be enabled only before OS loads (in BIOS) only if motherboard's BIOS and NIC's FW has support of it
- whenLINK_DOWN_ON_CLOSE_ENABLEDis used, the link is being brought down by sending phy_type=0 to NIC's FW
- whenTOTAL_PORT_SHUTDOWNis used,phy_typeis not altered, instead the link is being brought down by clearing bit (I40E_AQ_PHY_ENABLE_LINK) in abilities field ofi40e_aq_set_phy_configstructureIntroduced changes:
- new private flagI40E_FLAG_TOTAL_PORT_SHUTDOWNfor handling the feature
- probe of NVM if the feature was enabled at driver's port initialization
- special handling on link-down procedure to let FW physically shutdown the port if the feature was enabledSigned-off-by Arkadiusz Kubalewski <[email protected]>Signed-off-by Aleksandr Loktionov <[email protected]>---
v3:
- error messages changed
- '_ENABLED' suffix in a new private flag name
- new comment for documentation of a new private flag
- rewrite commit message--- Cut off before submitting to external review --- Testing Hints (required if no HSD):
Link up/down, link-down-on-closeChange-Id: I5427227c31b5e2d30f1149ad8d27d475caa27241
Title: i40e: Add support for a new feature: Total Port Shutdown
Change-type: FeatureImplementation
HSDES-Number: 2209979406
HSDES-Tenant: server_platf_lan.bug
Quoted 5 lines
--- drivers/net/ethernet/intel/i40e/i40e.h | 22 ++++ .../net/ethernet/intel/i40e/i40e_ethtool.c | 9 ++ drivers/net/ethernet/intel/i40e/i40e_main.c | 124 +++++++++++++++--- 3 files changed, 134 insertions(+), 21 deletions(-)