net: dsa: mt7530: support setting ageing time
Subsystems (5)
RFC PATCH 1/1 net: dsa: mt7530: support setting ageing time
MT7530 has a global address age control register, so use it to set ageing time.
The applied timer is (AGE_CNT + 1) * (AGE_UNIT + 1) seconds
--- drivers/net/dsa/mt7530.c | 41 ++++++++++++++++++++++++++++++++++++++++ drivers/net/dsa/mt7530.h | 13 +++++++++++++ 2 files changed, 54 insertions(+)
RFC:
1. What is the expected behaviour if the timer is too big or too small?
- return -ERANGE or -EINVAL;
or
- if it is too big, apply the maximum value; if it is too small,
disable learning;
2. Is there a better algorithm to find the closest pair?
drivers/net/dsa/mt7530.c +41 -0
@@ -870,6 +870,46 @@ mt7530_get_sset_count(struct dsa_switch *ds, int port, int sset)return ARRAY_SIZE (mt7530_mib); } +static int +mt7530_set_ageing_time (struct dsa_switch *ds,unsigned int msecs) +{ +struct mt7530_priv *priv = ds->priv; +unsigned int secs = msecs /1000 ; +unsigned int tmp_age_count; +unsigned int error =-1 ; +unsigned int age_count; +unsigned int age_unit; + +/* Applied timer is (AGE_CNT + 1) * (AGE_UNIT + 1) seconds */ +if (secs <1 || secs > (AGE_CNT_MAX +1 ) * (AGE_UNIT_MAX +1 )) +return -ERANGE ; + +/* iterate through all possible age_count to find the closest pair */ +for (tmp_age_count =0 ; tmp_age_count <=AGE_CNT_MAX ; ++tmp_age_count) { +unsigned int tmp_age_unit = secs / (tmp_age_count +1 ) -1 ; + +if (tmp_age_unit <=AGE_UNIT_MAX ) { +unsigned int tmp_error = secs - + (tmp_age_count +1 ) * (tmp_age_unit +1 ); + +/* found a closer pair */ +if (error > tmp_error) { + error = tmp_error; + age_count = tmp_age_count; + age_unit = tmp_age_unit; + } + +/* found the exact match, so break the loop */ +if (!error) +break ; + } + } + +mt7530_write (priv,MT7530_AAC ,AGE_CNT (age_count) |AGE_UNIT (age_unit)); + +return 0 ; +} +static void mt7530_setup_port5 (struct dsa_switch *ds,phy_interface_t interface) {struct mt7530_priv *priv = ds->priv;
@@ -2564,6 +2604,7 @@ static const struct dsa_switch_ops mt7530_switch_ops = { .phy_write = mt753x_phy_write, .get_ethtool_stats = mt7530_get_ethtool_stats, .get_sset_count = mt7530_get_sset_count, + .set_ageing_time = mt7530_set_ageing_time, .port_enable = mt7530_port_enable, .port_disable = mt7530_port_disable, .port_change_mtu = mt7530_port_change_mtu,
drivers/net/dsa/mt7530.h +13 -0
@@ -161,6 +161,19 @@ enum mt7530_vlan_egress_attr { MT7530_VLAN_EGRESS_STACK = 3, }; +/* Register for address age control */ +#define MT7530_AAC 0xa0 +/* Disable ageing */ +#define AGE_DIS BIT(20) +/* Age count */ +#define AGE_CNT_MASK GENMASK(19, 12) +#define AGE_CNT_MAX 0xff +#define AGE_CNT (x) (AGE_CNT_MASK & ((x) << 12)) +/* Age unit */ +#define AGE_UNIT_MASK GENMASK(11, 0) +#define AGE_UNIT_MAX 0xfff +#define AGE_UNIT (x) (AGE_UNIT_MASK & (x)) +/* Register for port STP state control */ #define MT7530_SSP_P (x) (0x2000 + ((x) * 0x100))#define FID_PST (x) ((x) & 0x3)
Signature · 1 line
2.25.1
Andrew Lunn
maintainerQuoted 6 lines · DENG Qingfang
MT7530 has a global address age control register, so use it to set ageing time.
The applied timer is (
AGE_CNT+ 1) * (AGE_UNIT+ 1) secondsSigned-off-by DENG Qingfang <[email protected]>
Quoted 8 lines
--- drivers/net/dsa/mt7530.c | 41 ++++++++++++++++++++++++++++++++++++++++ drivers/net/dsa/mt7530.h | 13 +++++++++++++ 2 files changed, 54 insertions(+)RFC:
1. What is the expected behaviour if the timer is too big or too small?
- return-ERANGEor-EINVAL;
ERANGE is good.
Quoted 5 lines
or
- if it is too big, apply the maximum value; if it is too small,disable learning;2. Is there a better algorithm to find the closest pair?
The bridge code will default to 300 seconds. And after a topology change, it sets it to 2 * the forwarding delay, which defaults to 15 seconds. So maybe you can look for these two values, and use pre-computed values?
You still need to handle other values, the user can configure these.
Andrew
_______________________________________________
Linux-mediatek mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/linux-mediatek
Quoted 4 lines · Andrew Lunn
The bridge code will default to 300 seconds. And after a topology change, it sets it to 2 * the forwarding delay, which defaults to 15 seconds. So maybe you can look for these two values, and use pre-computed values?
15 and 300 are not larger than 4096 (AGE_UNIT_MAX + 1) so the exact match can always be found in the first iteration:
age_count = 0, age_unit = 14, secs = (0 + 1) * (14 + 1) = 15 age_count = 0, age_unit = 299, secs = (0 + 1) * (299 + 1) = 300
Quoted 4 lines
You still need to handle other values, the user can configure these.
Andrew