v3 cover ibmvnic: assorted bug fixes

Assorted fixes for ibmvnic originated from "[PATCH net 00/15] ibmvnic:
assorted bug fixes" sent by Lijun Pan.

v3 Changes as suggested by Jakub Kicinski:
- Add a space between variable declaration and code in patch 3/9. Checkpatch does not catch this.
- Unwrapped FIXES lines in patch 9/9.
- Removed all extra line between Fixes and Signed-off-by lines in all patches.

V2 Changes as suggested by Jakub Kicinski:
- Added "Fixes" to each patch.
- Remove "ibmvnic: process HMC disable command" from the series. Submitting it separately to net-next.
- Squash V1 "ibmvnic: remove free_all_rwi function" into
ibmvnic: stop free_all_rwi on failed reset.

Dany Madden (7):
ibmvnic: handle inconsistent login with reset
ibmvnic: stop free_all_rwi on failed reset
ibmvnic: avoid memset null scrq msgs
ibmvnic: restore adapter state on failed reset
ibmvnic: send_login should check for crq errors
ibmvnic: no reset timeout for 5 seconds after reset
ibmvnic: reduce wait for completion time

Sukadev Bhattiprolu (2):
ibmvnic: delay next reset if hard reset fails
ibmvnic: track pending login

 drivers/net/ethernet/ibm/ibmvnic.c | 168 ++++++++++++++++++-----------
 drivers/net/ethernet/ibm/ibmvnic.h |   3 +
 2 files changed, 106 insertions(+), 65 deletions(-)
Signature · 1 line
2.26.2
#3 lore raw

PATCH v3 3/9 ibmvnic: avoid memset null scrq msgs

scrq->msgs could be NULL during device reset, causing Linux to crash. So, check before memset scrq->msgs.

Fixes c8b2ad0a4a901 ("ibmvnic: Sanitize entire SCRQ buffer on reset")
---
 drivers/net/ethernet/ibm/ibmvnic.c | 19 +++++++++++++++----
 1 file changed, 15 insertions(+), 4 deletions(-)
drivers/net/ethernet/ibm/ibmvnic.c +15 -4
index d5a927bb4954..b08f95017825 100644
@@ -2845,15 +2845,26 @@ static int reset_one_sub_crq_queue(struct ibmvnic_adapter *adapter,
 {
 	int rc;
 
+	if (!scrq) {
+		netdev_dbg(adapter->netdev,
+			   "Invalid scrq reset. irq (%d) or msgs (%p).\n",
+			   scrq->irq, scrq->msgs);
+		return -EINVAL;
+	}
+
 	if (scrq->irq) {
 		free_irq(scrq->irq, scrq);
 		irq_dispose_mapping(scrq->irq);
 		scrq->irq = 0;
 	}
-
-	memset(scrq->msgs, 0, 4 * PAGE_SIZE);
-	atomic_set(&scrq->used, 0);
-	scrq->cur = 0;
+	if (scrq->msgs) {
+		memset(scrq->msgs, 0, 4 * PAGE_SIZE);
+		atomic_set(&scrq->used, 0);
+		scrq->cur = 0;
+	} else {
+		netdev_dbg(adapter->netdev, "Invalid scrq reset\n");
+		return -EINVAL;
+	}
 
 	rc = h_reg_sub_crq(adapter->vdev->unit_address, scrq->msg_token,
 			   4 * PAGE_SIZE, &scrq->crq_num, &scrq->hw_irq);
Signature · 1 line
2.26.2
#5 lore raw

PATCH v3 5/9 ibmvnic: delay next reset if hard reset fails

In reply to Dany Madden

From: Sukadev Bhattiprolu <[email protected]>

If auto-priority failover is enabled, the backing device needs time to settle if hard resetting fails for any reason. Add a delay of 60 seconds before retrying the hard-reset.

Fixes 2770a7984db5 ("ibmvnic: Introduce hard reset recovery")
---
 drivers/net/ethernet/ibm/ibmvnic.c | 8 ++++++++
 1 file changed, 8 insertions(+)
drivers/net/ethernet/ibm/ibmvnic.c +8 -0
index ff474a790181..e2f9b0e9dea8 100644
@@ -2242,6 +2242,14 @@ static void __ibmvnic_reset(struct work_struct *work)
 				rc = do_hard_reset(adapter, rwi, reset_state);
 				rtnl_unlock();
 			}
+			if (rc) {
+				/* give backing device time to settle down */
+				netdev_dbg(adapter->netdev,
+					   "[S:%d] Hard reset failed, waiting 60 secs\n",
+					   adapter->state);
+				set_current_state(TASK_UNINTERRUPTIBLE);
+				schedule_timeout(60 * HZ);
+			}
 		} else if (!(rwi->reset_reason == VNIC_RESET_FATAL &&
 				adapter->from_passive_init)) {
 			rc = do_reset(adapter, rwi, reset_state);
Signature · 1 line
2.26.2
#7 lore raw

PATCH v3 7/9 ibmvnic: send_login should check for crq errors

In reply to Dany Madden

send_login() does not check for the result of ibmvnic_send_crq() of the login request. This results in the driver needlessly retrying the login 10 times even when CRQ is no longer active. Check the return code and give up in case of errors in sending the CRQ.

The only time we want to retry is if we get a PARITALSUCCESS response from the partner.

Fixes 032c5e82847a2 ("Driver for IBM System i/p VNIC protocol")
---
 drivers/net/ethernet/ibm/ibmvnic.c | 18 ++++++++++++------
 1 file changed, 12 insertions(+), 6 deletions(-)
drivers/net/ethernet/ibm/ibmvnic.c +12 -6
index 55b07bd4c741..9005fab09e15 100644
@@ -850,10 +850,8 @@ static int ibmvnic_login(struct net_device *netdev)
 		adapter->init_done_rc = 0;
 		reinit_completion(&adapter->init_done);
 		rc = send_login(adapter);
-		if (rc) {
-			netdev_warn(netdev, "Unable to login\n");
+		if (rc)
 			return rc;
-		}
 
 		if (!wait_for_completion_timeout(&adapter->init_done,
 						 timeout)) {
@@ -3727,15 +3725,16 @@ static int send_login(struct ibmvnic_adapter *adapter)
 	struct ibmvnic_login_rsp_buffer *login_rsp_buffer;
 	struct ibmvnic_login_buffer *login_buffer;
 	struct device *dev = &adapter->vdev->dev;
+	struct vnic_login_client_data *vlcd;
 	dma_addr_t rsp_buffer_token;
 	dma_addr_t buffer_token;
 	size_t rsp_buffer_size;
 	union ibmvnic_crq crq;
+	int client_data_len;
 	size_t buffer_size;
 	__be64 *tx_list_p;
 	__be64 *rx_list_p;
-	int client_data_len;
-	struct vnic_login_client_data *vlcd;
+	int rc;
 	int i;
 
 	if (!adapter->tx_scrq || !adapter->rx_scrq) {
@@ -3841,16 +3840,23 @@ static int send_login(struct ibmvnic_adapter *adapter)
 	crq.login.len = cpu_to_be32(buffer_size);
 
 	adapter->login_pending = true;
-	ibmvnic_send_crq(adapter, &crq);
+	rc = ibmvnic_send_crq(adapter, &crq);
+	if (rc) {
+		adapter->login_pending = false;
+		netdev_err(adapter->netdev, "Failed to send login, rc=%d\n", rc);
+		goto buf_rsp_map_failed;
+	}
 
 	return 0;
 
 buf_rsp_map_failed:
 	kfree(login_rsp_buffer);
+	adapter->login_rsp_buf = NULL;
 buf_rsp_alloc_failed:
 	dma_unmap_single(dev, buffer_token, buffer_size, DMA_TO_DEVICE);
 buf_map_failed:
 	kfree(login_buffer);
+	adapter->login_buf = NULL;
 buf_alloc_failed:
 	return -1;
 }
Signature · 1 line
2.26.2
#6 lore raw

PATCH v3 6/9 ibmvnic: track pending login

In reply to Dany Madden

From: Sukadev Bhattiprolu <[email protected]>

If after ibmvnic sends a LOGIN it gets a FAILOVER, it is possible that the worker thread will start reset process and free the login response buffer before it gets a (now stale) LOGIN_RSP. The ibmvnic tasklet will then try to access the login response buffer and crash.

Have ibmvnic track pending logins and discard any stale login responses.

Fixes 032c5e82847a ("Driver for IBM System i/p VNIC protocol")
---
 drivers/net/ethernet/ibm/ibmvnic.c | 17 +++++++++++++++++
 drivers/net/ethernet/ibm/ibmvnic.h |  1 +
 2 files changed, 18 insertions(+)
drivers/net/ethernet/ibm/ibmvnic.c +17 -0
index e2f9b0e9dea8..55b07bd4c741 100644
@@ -3839,6 +3839,8 @@ static int send_login(struct ibmvnic_adapter *adapter)
 	crq.login.cmd = LOGIN;
 	crq.login.ioba = cpu_to_be32(buffer_token);
 	crq.login.len = cpu_to_be32(buffer_size);
+
+	adapter->login_pending = true;
 	ibmvnic_send_crq(adapter, &crq);
 
 	return 0;
@@ -4391,6 +4393,15 @@ static int handle_login_rsp(union ibmvnic_crq *login_rsp_crq,
 	u64 *size_array;
 	int i;
 
+	/* CHECK: Test/set of login_pending does not need to be atomic
+	 * because only ibmvnic_tasklet tests/clears this.
+	 */
+	if (!adapter->login_pending) {
+		netdev_warn(netdev, "Ignoring unexpected login response\n");
+		return 0;
+	}
+	adapter->login_pending = false;
+
 	dma_unmap_single(dev, adapter->login_buf_token, adapter->login_buf_sz,
 			 DMA_TO_DEVICE);
 	dma_unmap_single(dev, adapter->login_rsp_buf_token,
@@ -4762,6 +4773,11 @@ static void ibmvnic_handle_crq(union ibmvnic_crq *crq,
 		case IBMVNIC_CRQ_INIT:
 			dev_info(dev, "Partner initialized\n");
 			adapter->from_passive_init = true;
+			/* Discard any stale login responses from prev reset.
+			 * CHECK: should we clear even on INIT_COMPLETE?
+			 */
+			adapter->login_pending = false;
+
 			if (!completion_done(&adapter->init_done)) {
 				complete(&adapter->init_done);
 				adapter->init_done_rc = -EIO;
@@ -5191,6 +5207,7 @@ static int ibmvnic_probe(struct vio_dev *dev, const struct vio_device_id *id)
 	dev_set_drvdata(&dev->dev, netdev);
 	adapter->vdev = dev;
 	adapter->netdev = netdev;
+	adapter->login_pending = false;
 
 	ether_addr_copy(adapter->mac_addr, mac_addr_p);
 	ether_addr_copy(netdev->dev_addr, adapter->mac_addr);
drivers/net/ethernet/ibm/ibmvnic.h +1 -0
index 217dcc7ded70..6f0a701c4a38 100644
@@ -1087,6 +1087,7 @@ struct ibmvnic_adapter {
 	struct delayed_work ibmvnic_delayed_reset;
 	unsigned long resetting;
 	bool napi_enabled, from_passive_init;
+	bool login_pending;
 
 	bool failover_pending;
 	bool force_reset_recovery;
Signature · 1 line
2.26.2
#9 lore raw

PATCH v3 9/9 ibmvnic: reduce wait for completion time

In reply to Dany Madden

Reduce the wait time for Command Response Queue response from 30 seconds to 20 seconds, as recommended by VIOS and Power Hypervisor teams.

Fixes bd0b672313941 ("ibmvnic: Move login and queue negotiation into ibmvnic_open")
Fixes 53da09e92910f ("ibmvnic: Add set_link_state routine for setting adapter link state")
---
 drivers/net/ethernet/ibm/ibmvnic.c | 6 +++---
 1 file changed, 3 insertions(+), 3 deletions(-)
drivers/net/ethernet/ibm/ibmvnic.c +3 -3
index a17856be2828..d6b2686aed0f 100644
@@ -834,7 +834,7 @@ static void release_napi(struct ibmvnic_adapter *adapter)
 static int ibmvnic_login(struct net_device *netdev)
 {
 	struct ibmvnic_adapter *adapter = netdev_priv(netdev);
-	unsigned long timeout = msecs_to_jiffies(30000);
+	unsigned long timeout = msecs_to_jiffies(20000);
 	int retry_count = 0;
 	int retries = 10;
 	bool retry;
@@ -938,7 +938,7 @@ static void release_resources(struct ibmvnic_adapter *adapter)
 static int set_link_state(struct ibmvnic_adapter *adapter, u8 link_state)
 {
 	struct net_device *netdev = adapter->netdev;
-	unsigned long timeout = msecs_to_jiffies(30000);
+	unsigned long timeout = msecs_to_jiffies(20000);
 	union ibmvnic_crq crq;
 	bool resend;
 	int rc;
@@ -5125,7 +5125,7 @@ static int init_crq_queue(struct ibmvnic_adapter *adapter)
 static int ibmvnic_reset_init(struct ibmvnic_adapter *adapter, bool reset)
 {
 	struct device *dev = &adapter->vdev->dev;
-	unsigned long timeout = msecs_to_jiffies(30000);
+	unsigned long timeout = msecs_to_jiffies(20000);
 	u64 old_num_rx_queues, old_num_tx_queues;
 	int rc;
 
Signature · 1 line
2.26.2
#8 lore raw

PATCH v3 8/9 ibmvnic: no reset timeout for 5 seconds after reset

In reply to Dany Madden

Reset timeout is going off right after adapter reset. This patch ensures that timeout is scheduled if it has been 5 seconds since the last reset. 5 seconds is the default watchdog timeout.

Fixes ed651a10875f1 ("ibmvnic: Updated reset handling")
---
 drivers/net/ethernet/ibm/ibmvnic.c | 11 +++++++++--
 drivers/net/ethernet/ibm/ibmvnic.h |  2 ++
 2 files changed, 11 insertions(+), 2 deletions(-)
drivers/net/ethernet/ibm/ibmvnic.c +9 -2
index 9005fab09e15..a17856be2828 100644
@@ -2253,6 +2253,7 @@ static void __ibmvnic_reset(struct work_struct *work)
 			rc = do_reset(adapter, rwi, reset_state);
 		}
 		kfree(rwi);
+		adapter->last_reset_time = jiffies;
 
 		if (rc)
 			netdev_dbg(adapter->netdev, "Reset failed, rc=%d\n", rc);
@@ -2356,7 +2357,13 @@ static void ibmvnic_tx_timeout(struct net_device *dev, unsigned int txqueue)
 			   "Adapter is resetting, skip timeout reset\n");
 		return;
 	}
-
+	/* No queuing up reset until at least 5 seconds (default watchdog val)
+	 * after last reset
+	 */
+	if (time_before(jiffies, (adapter->last_reset_time + dev->watchdog_timeo))) {
+		netdev_dbg(dev, "Not yet time to tx timeout.\n");
+		return;
+	}
 	ibmvnic_reset(adapter, VNIC_RESET_TIMEOUT);
 }
 
@@ -5277,7 +5284,7 @@ static int ibmvnic_probe(struct vio_dev *dev, const struct vio_device_id *id)
 	adapter->state = VNIC_PROBED;
 
 	adapter->wait_for_reset = false;
-
+	adapter->last_reset_time = jiffies;
 	return 0;
 
 ibmvnic_register_fail:
drivers/net/ethernet/ibm/ibmvnic.h +2 -0
index 6f0a701c4a38..b21092f5f9c1 100644
@@ -1088,6 +1088,8 @@ struct ibmvnic_adapter {
 	unsigned long resetting;
 	bool napi_enabled, from_passive_init;
 	bool login_pending;
+	/* last device reset time */
+	unsigned long last_reset_time;
 
 	bool failover_pending;
 	bool force_reset_recovery;
Signature · 1 line
2.26.2
#2 lore raw

PATCH v3 2/9 ibmvnic: stop free_all_rwi on failed reset

In reply to Dany Madden

When ibmvnic fails to reset, it breaks out of the reset loop and frees all of the remaining resets from the workqueue. Doing so prevents the adapter from recovering if no reset is scheduled after that. Instead, have the driver continue to process resets on the workqueue.

Remove the no longer need free_all_rwi().

Fixes ed651a10875f1 ("ibmvnic: Updated reset handling")
---
 drivers/net/ethernet/ibm/ibmvnic.c | 22 +++-------------------
 1 file changed, 3 insertions(+), 19 deletions(-)
drivers/net/ethernet/ibm/ibmvnic.c +3 -19
index dcb23015b6b4..d5a927bb4954 100644
@@ -2173,17 +2173,6 @@ static struct ibmvnic_rwi *get_next_rwi(struct ibmvnic_adapter *adapter)
 	return rwi;
 }
 
-static void free_all_rwi(struct ibmvnic_adapter *adapter)
-{
-	struct ibmvnic_rwi *rwi;
-
-	rwi = get_next_rwi(adapter);
-	while (rwi) {
-		kfree(rwi);
-		rwi = get_next_rwi(adapter);
-	}
-}
-
 static void __ibmvnic_reset(struct work_struct *work)
 {
 	struct ibmvnic_rwi *rwi;
@@ -2253,9 +2242,9 @@ static void __ibmvnic_reset(struct work_struct *work)
 			else
 				adapter->state = reset_state;
 			rc = 0;
-		} else if (rc && rc != IBMVNIC_INIT_FAILED &&
-		    !adapter->force_reset_recovery)
-			break;
+		}
+		if (rc)
+			netdev_dbg(adapter->netdev, "Reset failed, rc=%d\n", rc);
 
 		rwi = get_next_rwi(adapter);
 
@@ -2269,11 +2258,6 @@ static void __ibmvnic_reset(struct work_struct *work)
 		complete(&adapter->reset_done);
 	}
 
-	if (rc) {
-		netdev_dbg(adapter->netdev, "Reset failed\n");
-		free_all_rwi(adapter);
-	}
-
 	clear_bit_unlock(0, &adapter->resetting);
 }
 
Signature · 1 line
2.26.2
#4 lore raw

PATCH v3 4/9 ibmvnic: restore adapter state on failed reset

In reply to Dany Madden

In a failed reset, driver could end up in VNIC_PROBED or VNIC_CLOSED state and cannot recover in subsequent resets, leaving it offline. This patch restores the adapter state to reset_state, the original state when reset was called.

Fixes b27507bb59ed5 ("net/ibmvnic: unlock rtnl_lock in reset so linkwatch_event can run")
Fixes 2770a7984db58 ("ibmvnic: Introduce hard reset recovery")
---
 drivers/net/ethernet/ibm/ibmvnic.c | 67 ++++++++++++++++--------------
 1 file changed, 36 insertions(+), 31 deletions(-)
drivers/net/ethernet/ibm/ibmvnic.c +36 -31
index b08f95017825..ff474a790181 100644
@@ -1857,7 +1857,7 @@ static int do_change_param_reset(struct ibmvnic_adapter *adapter,
 	if (reset_state == VNIC_OPEN) {
 		rc = __ibmvnic_close(netdev);
 		if (rc)
-			return rc;
+			goto out;
 	}
 
 	release_resources(adapter);
@@ -1875,24 +1875,25 @@ static int do_change_param_reset(struct ibmvnic_adapter *adapter,
 	}
 
 	rc = ibmvnic_reset_init(adapter, true);
-	if (rc)
-		return IBMVNIC_INIT_FAILED;
+	if (rc) {
+		rc = IBMVNIC_INIT_FAILED;
+		goto out;
+	}
 
 	/* If the adapter was in PROBE state prior to the reset,
 	 * exit here.
 	 */
 	if (reset_state == VNIC_PROBED)
-		return 0;
+		goto out;
 
 	rc = ibmvnic_login(netdev);
 	if (rc) {
-		adapter->state = reset_state;
-		return rc;
+		goto out;
 	}
 
 	rc = init_resources(adapter);
 	if (rc)
-		return rc;
+		goto out;
 
 	ibmvnic_disable_irqs(adapter);
 
@@ -1902,8 +1903,10 @@ static int do_change_param_reset(struct ibmvnic_adapter *adapter,
 		return 0;
 
 	rc = __ibmvnic_open(netdev);
-	if (rc)
-		return IBMVNIC_OPEN_FAILED;
+	if (rc) {
+		rc = IBMVNIC_OPEN_FAILED;
+		goto out;
+	}
 
 	/* refresh device's multicast list */
 	ibmvnic_set_multi(netdev);
@@ -1912,7 +1915,10 @@ static int do_change_param_reset(struct ibmvnic_adapter *adapter,
 	for (i = 0; i < adapter->req_rx_queues; i++)
 		napi_schedule(&adapter->napi[i]);
 
-	return 0;
+out:
+	if (rc)
+		adapter->state = reset_state;
+	return rc;
 }
 
 /**
@@ -2015,7 +2021,6 @@ static int do_reset(struct ibmvnic_adapter *adapter,
 
 		rc = ibmvnic_login(netdev);
 		if (rc) {
-			adapter->state = reset_state;
 			goto out;
 		}
 
@@ -2083,6 +2088,9 @@ static int do_reset(struct ibmvnic_adapter *adapter,
 	rc = 0;
 
 out:
+	/* restore the adapter state if reset failed */
+	if (rc)
+		adapter->state = reset_state;
 	rtnl_unlock();
 
 	return rc;
@@ -2115,43 +2123,46 @@ static int do_hard_reset(struct ibmvnic_adapter *adapter,
 	if (rc) {
 		netdev_err(adapter->netdev,
 			   "Couldn't initialize crq. rc=%d\n", rc);
-		return rc;
+		goto out;
 	}
 
 	rc = ibmvnic_reset_init(adapter, false);
 	if (rc)
-		return rc;
+		goto out;
 
 	/* If the adapter was in PROBE state prior to the reset,
 	 * exit here.
 	 */
 	if (reset_state == VNIC_PROBED)
-		return 0;
+		goto out;
 
 	rc = ibmvnic_login(netdev);
-	if (rc) {
-		adapter->state = VNIC_PROBED;
-		return 0;
-	}
+	if (rc)
+		goto out;
 
 	rc = init_resources(adapter);
 	if (rc)
-		return rc;
+		goto out;
 
 	ibmvnic_disable_irqs(adapter);
 	adapter->state = VNIC_CLOSED;
 
 	if (reset_state == VNIC_CLOSED)
-		return 0;
+		goto out;
 
 	rc = __ibmvnic_open(netdev);
-	if (rc)
-		return IBMVNIC_OPEN_FAILED;
+	if (rc) {
+		rc = IBMVNIC_OPEN_FAILED;
+		goto out;
+	}
 
 	call_netdevice_notifiers(NETDEV_NOTIFY_PEERS, netdev);
 	call_netdevice_notifiers(NETDEV_RESEND_IGMP, netdev);
-
-	return 0;
+out:
+	/* restore adapter state if reset failed */
+	if (rc)
+		adapter->state = reset_state;
+	return rc;
 }
 
 static struct ibmvnic_rwi *get_next_rwi(struct ibmvnic_adapter *adapter)
@@ -2236,13 +2247,7 @@ static void __ibmvnic_reset(struct work_struct *work)
 			rc = do_reset(adapter, rwi, reset_state);
 		}
 		kfree(rwi);
-		if (rc == IBMVNIC_OPEN_FAILED) {
-			if (list_empty(&adapter->rwi_list))
-				adapter->state = VNIC_CLOSED;
-			else
-				adapter->state = reset_state;
-			rc = 0;
-		}
+
 		if (rc)
 			netdev_dbg(adapter->netdev, "Reset failed, rc=%d\n", rc);
 
Signature · 1 line
2.26.2
#1 lore raw

PATCH v3 1/9 ibmvnic: handle inconsistent login with reset

In reply to Dany Madden

Inconsistent login with the vnicserver is causing the device to be removed. This does not give the device a chance to recover from error state. This patch schedules a FATAL reset instead to bring the adapter up.

Fixes 032c5e82847a2 ("Driver for IBM System i/p VNIC protocol")
---
 drivers/net/ethernet/ibm/ibmvnic.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/net/ethernet/ibm/ibmvnic.c +1 -1
index 2aa40b2f225c..dcb23015b6b4 100644
@@ -4412,7 +4412,7 @@ static int handle_login_rsp(union ibmvnic_crq *login_rsp_crq,
 	     adapter->req_rx_add_queues !=
 	     be32_to_cpu(login_rsp->num_rxadd_subcrqs))) {
 		dev_err(dev, "FATAL: Inconsistent login and login rsp\n");
-		ibmvnic_remove(adapter->vdev);
+		ibmvnic_reset(adapter, VNIC_RESET_FATAL);
 		return -EIO;
 	}
 	size_array = (u64 *)((u8 *)(adapter->login_rsp_buf) +
Signature · 1 line
2.26.2
maintainer Applied
#10 lore raw
In reply to Dany Madden
Quoted 2 lines · On Wed, 25 Nov 2020 18:04:23 -0600 Dany Madden wrote:

Assorted fixes for ibmvnic originated from "[PATCH net 00/15] ibmvnic:
assorted bug fixes" sent by Lijun Pan.

Applied, thanks!