Documentation: media: camera-sensor: The unit of hblank is pixels

PATCH New Sakari Ailus 1 participant 1 message Feb 1, 2021

Subsystems (2)
lore
Share & tools
lore

Sakari Ailus

author maintainer
#0 lore raw

PATCH 1/1 Documentation: media: camera-sensor: The unit of hblank is pixels

The unit of the horizontal blanking control on raw sensors is pixels, not lines. Document this correctly.

Fixes e4cf8c58af75 ("media: Documentation: media: Document how to write camera sensor drivers")
---
 Documentation/driver-api/media/camera-sensor.rst | 7 ++++---
 1 file changed, 4 insertions(+), 3 deletions(-)
Documentation/driver-api/media/camera-sensor.rst +4 -3
index 3fc378b3b269..9c863e3a79ba 100644
@@ -94,9 +94,10 @@ large variety of devices beyond camera sensors. Devices that have no analogue
 crop, use the full source image size, i.e. pixel array size.
 
 Horizontal and vertical blanking are specified by ``V4L2_CID_HBLANK`` and
-``V4L2_CID_VBLANK``, respectively. The unit of these controls are lines. The
-pixel rate is specified by ``V4L2_CID_PIXEL_RATE`` in the same sub-device. The
-unit of that control is Hz.
+``V4L2_CID_VBLANK``, respectively. The unit of the ``V4L2_CID_HBLANK`` control
+is pixels and the unit of the ``V4L2_CID_VBLANK`` is lines. The pixel rate is
+specified by ``V4L2_CID_PIXEL_RATE`` in the same sub-device. The unit of that
+control is Hz.
 
 Register list based drivers need to implement read-only sub-device nodes for the
 purpose. Devices that are not register list based need these to configure the
Signature · 1 line