pwmconfig: Deal gracefully with unreadable fan inputs
PATCH 1/1 pwmconfig: Deal gracefully with unreadable fan inputs
If a hwmon driver exposes an unreadable fan input, let the user know and skip that input. Otherwise we hit syntax errors later on.
Signed-off-by Jean Delvare <[email protected]>
--- prog/pwm/pwmconfig | 7 +++++-- 1 file changed, 5 insertions(+), 2 deletions(-)
prog/pwm/pwmconfig +5 -2
@@ -283,8 +283,11 @@ sleep $DELAY echo 'Found the following fan sensors:' for i in $FAN do - S=$(cat $i) - if [ "$S" = "0" -o "$S" = "-1" ] + S=$(cat $i 2> /dev/null) + if [ $? -ne 0 ] + then + echo " $i current speed: can't read ... skipping!" + elif [ "$S" = "0" -o "$S" = "-1" ] then echo " $i current speed: 0 ... skipping!" else
Signature · 2 lines
Jean Delvare SUSE L3 Support