fpga: region: handle compat_id as an uuid

PATCH In review [email protected] 6 participants 14 messages Jul 26, 2021 – Aug 6, 2021

Subsystems (2)
lore
Share & tools
lore

[email protected]

author reviewer
#0 lore raw

PATCH 1/1 fpga: region: handle compat_id as an uuid

From: Tom Rix <[email protected]>

An fpga region's compat_id is exported by the sysfs as a 128 bit hex string formed by concatenating two 64 bit values together.

The only user of compat_id is dfl. Its user library opae converts this value into a uuid.

ex/

$ cat /sys/class/fpga_region/region1/compat_id
f3c9941350814aadbced07eb84a6d0bb

Is reported as

$ fpgainfo bmc
...
Pr Interface Id                  : f3c99413-5081-4aad-bced-07eb84a6d0bb

Storing a uuid as 2 64 bit values is vendor specific. And concatenating them together is vendor specific.

It is better to store and print out as a vendor neutral uuid.

Change fpga_compat_id from a struct to a union. Keep the old 64 bit values for dfl.
Sysfs output is now f3c99413-5081-4aad-bced-07eb84a6d0bb

---
 .../ABI/testing/sysfs-class-fpga-region        |  4 ++--
 drivers/fpga/dfl-fme-mgr.c                     |  8 ++++----
 drivers/fpga/fpga-region.c                     |  4 +---
 include/linux/fpga/fpga-mgr.h                  | 18 ++++++++++++------
 include/linux/fpga/fpga-region.h               |  2 +-
 5 files changed, 20 insertions(+), 16 deletions(-)
Documentation/ABI/testing/sysfs-class-fpga-region +2 -2
index bc7ec644acc9a..241359fb74a55 100644
@@ -5,5 +5,5 @@ Contact:	Wu Hao <[email protected]>
 Description:	FPGA region id for compatibility check, e.g. compatibility
 		of the FPGA reconfiguration hardware and image. This value
 		is defined or calculated by the layer that is creating the
-		FPGA region. This interface returns the compat_id value or
-		just error code -ENOENT in case compat_id is not used.
+		FPGA region. This interface returns a uuid value or just
+		error code -ENOENT in case compat_id is not used.
drivers/fpga/dfl-fme-mgr.c +4 -4
index d5861d13b3069..012b72712684c 100644
@@ -273,16 +273,16 @@ static const struct fpga_manager_ops fme_mgr_ops = {
 };
 
 static void fme_mgr_get_compat_id(void __iomem *fme_pr,
-				  struct fpga_compat_id *id)
+				  union fpga_compat_id *id)
 {
-	id->id_l = readq(fme_pr + FME_PR_INTFC_ID_L);
-	id->id_h = readq(fme_pr + FME_PR_INTFC_ID_H);
+	id->id_l = cpu_to_be64(readq(fme_pr + FME_PR_INTFC_ID_L));
+	id->id_h = cpu_to_be64(readq(fme_pr + FME_PR_INTFC_ID_H));
 }
 
 static int fme_mgr_probe(struct platform_device *pdev)
 {
 	struct dfl_fme_mgr_pdata *pdata = dev_get_platdata(&pdev->dev);
-	struct fpga_compat_id *compat_id;
+	union fpga_compat_id *compat_id;
 	struct device *dev = &pdev->dev;
 	struct fme_mgr_priv *priv;
 	struct fpga_manager *mgr;
drivers/fpga/fpga-region.c +1 -3
index a4838715221ff..f1083b5894635 100644
@@ -166,9 +166,7 @@ static ssize_t compat_id_show(struct device *dev,
 	if (!region->compat_id)
 		return -ENOENT;
 
-	return sprintf(buf, "%016llx%016llx\n",
-		       (unsigned long long)region->compat_id->id_h,
-		       (unsigned long long)region->compat_id->id_l);
+	return sprintf(buf, "%pU\n", &region->compat_id->uuid);
 }
 
 static DEVICE_ATTR_RO(compat_id);
include/linux/fpga/fpga-mgr.h +12 -6
index ec2cd8bfceb00..b12f9994932e1 100644
@@ -10,6 +10,7 @@
 
 #include <linux/mutex.h>
 #include <linux/platform_device.h>
+#include <linux/uuid.h>
 
 struct fpga_manager;
 struct sg_table;
@@ -144,14 +145,19 @@ struct fpga_manager_ops {
 #define FPGA_MGR_STATUS_FIFO_OVERFLOW_ERR	BIT(4)
 
 /**
- * struct fpga_compat_id - id for compatibility check
- *
+ * union fpga_compat_id - id for compatibility check
+ * Can be accessed as either:
+ * @uuid: the base uuid_t type
+ * or
  * @id_h: high 64bit of the compat_id
  * @id_l: low 64bit of the compat_id
  */
-struct fpga_compat_id {
-	u64 id_h;
-	u64 id_l;
+union fpga_compat_id {
+	uuid_t uuid;
+	struct {
+		u64 id_h;
+		u64 id_l;
+	};
 };
 
 /**
@@ -169,7 +175,7 @@ struct fpga_manager {
 	struct device dev;
 	struct mutex ref_mutex;
 	enum fpga_mgr_states state;
-	struct fpga_compat_id *compat_id;
+	union fpga_compat_id *compat_id;
 	const struct fpga_manager_ops *mops;
 	void *priv;
 };
include/linux/fpga/fpga-region.h +1 -1
index 27cb706275dba..7cc2ee543efb4 100644
@@ -24,7 +24,7 @@ struct fpga_region {
 	struct list_head bridge_list;
 	struct fpga_manager *mgr;
 	struct fpga_image_info *info;
-	struct fpga_compat_id *compat_id;
+	union fpga_compat_id *compat_id;
 	void *priv;
 	int (*get_bridges)(struct fpga_region *region);
 };
Signature · 1 line
2.26.3
#1 lore raw
Quoted 21 lines · On 7/26/21 1:26 PM, [email protected] wrote:

From: Tom Rix <[email protected]>

An fpga region's compat_id is exported by the sysfs as a 128 bit hex string formed by concatenating two 64 bit values together.

The only user of compat_id is dfl. Its user library opae converts this value into a uuid.

ex/

$ cat /sys/class/fpga_region/region1/compat_id
f3c9941350814aadbced07eb84a6d0bb

Is reported as

$ fpgainfo bmc
...
Pr Interface Id                  : f3c99413-5081-4aad-bced-07eb84a6d0bb

Storing a uuid as 2 64 bit values is vendor specific. And concatenating them together is vendor specific.

Quoted 6 lines

It is better to store and print out as a vendor neutral uuid.

Change fpga_compat_id from a struct to a union. Keep the old 64 bit values for dfl.
Sysfs output is now f3c99413-5081-4aad-bced-07eb84a6d0bb

I'm fowarding feedback from Tim Whisonant, one of the OPAE userspace developers:

I think that this change to the sysfs for the compat_id node will end up breaking the SDK, which does not expect the '-' characters to be included when parsing the sysfs value. Currently, it is parsed as a raw hex string without regard to any '-' characters. This goes for any "guid" currently exported by sysfs and for what we read in the device MMIO space.

- Russ

Quoted 121 lines
---
 .../ABI/testing/sysfs-class-fpga-region        |  4 ++--
 drivers/fpga/dfl-fme-mgr.c                     |  8 ++++----
 drivers/fpga/fpga-region.c                     |  4 +---
 include/linux/fpga/fpga-mgr.h                  | 18 ++++++++++++------
 include/linux/fpga/fpga-region.h               |  2 +-
 5 files changed, 20 insertions(+), 16 deletions(-)
Documentation/ABI/testing/sysfs-class-fpga-region +2 -2
index bc7ec644acc9a..241359fb74a55 100644
@@ -5,5 +5,5 @@ Contact:	Wu Hao <[email protected]>
 Description:	FPGA region id for compatibility check, e.g. compatibility
 		of the FPGA reconfiguration hardware and image. This value
 		is defined or calculated by the layer that is creating the
-		FPGA region. This interface returns the compat_id value or
-		just error code -ENOENT in case compat_id is not used.
+		FPGA region. This interface returns a uuid value or just
+		error code -ENOENT in case compat_id is not used.
drivers/fpga/dfl-fme-mgr.c +4 -4
index d5861d13b3069..012b72712684c 100644
@@ -273,16 +273,16 @@ static const struct fpga_manager_ops fme_mgr_ops = {
 };
 
 static void fme_mgr_get_compat_id(void __iomem *fme_pr,
-				  struct fpga_compat_id *id)
+				  union fpga_compat_id *id)
 {
-	id->id_l = readq(fme_pr + FME_PR_INTFC_ID_L);
-	id->id_h = readq(fme_pr + FME_PR_INTFC_ID_H);
+	id->id_l = cpu_to_be64(readq(fme_pr + FME_PR_INTFC_ID_L));
+	id->id_h = cpu_to_be64(readq(fme_pr + FME_PR_INTFC_ID_H));
 }
 
 static int fme_mgr_probe(struct platform_device *pdev)
 {
 	struct dfl_fme_mgr_pdata *pdata = dev_get_platdata(&pdev->dev);
-	struct fpga_compat_id *compat_id;
+	union fpga_compat_id *compat_id;
 	struct device *dev = &pdev->dev;
 	struct fme_mgr_priv *priv;
 	struct fpga_manager *mgr;
drivers/fpga/fpga-region.c +1 -3
index a4838715221ff..f1083b5894635 100644
@@ -166,9 +166,7 @@ static ssize_t compat_id_show(struct device *dev,
 	if (!region->compat_id)
 		return -ENOENT;
 
-	return sprintf(buf, "%016llx%016llx\n",
-		       (unsigned long long)region->compat_id->id_h,
-		       (unsigned long long)region->compat_id->id_l);
+	return sprintf(buf, "%pU\n", &region->compat_id->uuid);
 }
 
 static DEVICE_ATTR_RO(compat_id);
include/linux/fpga/fpga-mgr.h +12 -6
index ec2cd8bfceb00..b12f9994932e1 100644
@@ -10,6 +10,7 @@
 
 #include <linux/mutex.h>
 #include <linux/platform_device.h>
+#include <linux/uuid.h>
 
 struct fpga_manager;
 struct sg_table;
@@ -144,14 +145,19 @@ struct fpga_manager_ops {
 #define FPGA_MGR_STATUS_FIFO_OVERFLOW_ERR	BIT(4)
 
 /**
- * struct fpga_compat_id - id for compatibility check
- *
+ * union fpga_compat_id - id for compatibility check
+ * Can be accessed as either:
+ * @uuid: the base uuid_t type
+ * or
  * @id_h: high 64bit of the compat_id
  * @id_l: low 64bit of the compat_id
  */
-struct fpga_compat_id {
-	u64 id_h;
-	u64 id_l;
+union fpga_compat_id {
+	uuid_t uuid;
+	struct {
+		u64 id_h;
+		u64 id_l;
+	};
 };
 
 /**
@@ -169,7 +175,7 @@ struct fpga_manager {
 	struct device dev;
 	struct mutex ref_mutex;
 	enum fpga_mgr_states state;
-	struct fpga_compat_id *compat_id;
+	union fpga_compat_id *compat_id;
 	const struct fpga_manager_ops *mops;
 	void *priv;
 };
include/linux/fpga/fpga-region.h +1 -1
index 27cb706275dba..7cc2ee543efb4 100644
@@ -24,7 +24,7 @@ struct fpga_region {
 	struct list_head bridge_list;
 	struct fpga_manager *mgr;
 	struct fpga_image_info *info;
-	struct fpga_compat_id *compat_id;
+	union fpga_compat_id *compat_id;
 	void *priv;
 	int (*get_bridges)(struct fpga_region *region);
 };
author reviewer
#2 lore raw
Quoted 31 lines · Russ Weight
Quoted 21 lines · On 7/26/21 1:26 PM, [email protected] wrote:

From: Tom Rix <[email protected]>

An fpga region's compat_id is exported by the sysfs as a 128 bit hex string formed by concatenating two 64 bit values together.

The only user of compat_id is dfl. Its user library opae converts this value into a uuid.

ex/

$ cat /sys/class/fpga_region/region1/compat_id
f3c9941350814aadbced07eb84a6d0bb

Is reported as

$ fpgainfo bmc
...
Pr Interface Id                  : f3c99413-5081-4aad-bced-07eb84a6d0bb

Storing a uuid as 2 64 bit values is vendor specific. And concatenating them together is vendor specific.

Quoted 6 lines

It is better to store and print out as a vendor neutral uuid.

Change fpga_compat_id from a struct to a union. Keep the old 64 bit values for dfl.
Sysfs output is now f3c99413-5081-4aad-bced-07eb84a6d0bb

I'm fowarding feedback from Tim Whisonant, one of the OPAE userspace developers:

Quoted 6 lines

I think that this change to the sysfs for the compat_id node will end up breaking the SDK, which does not expect the '-' characters to be included when parsing the sysfs value. Currently, it is parsed as a raw hex string without regard to any '-' characters. This goes for any "guid" currently exported by sysfs and for what we read in the device MMIO space.

Yes, it will.

And there are other places, like dfl-afu-main.c:afu_id_show()

outputs raw hex that sdk turns into a uuid.

Some options.

If no one but dfl will ever use it, then v1 of patchset.

If others can use it but don't want to change dfl, then v2 of patchset, my favorite.

Or this one for uuid for everyone, what have been v3 but changed too much.

could dfl change generally to output uuid's to the sysfs ?

this would be generally helpful and a one time disruption to the sdk.

Tom

Quoted 123 lines

- Russ

Quoted 120 lines
---
  .../ABI/testing/sysfs-class-fpga-region        |  4 ++--
  drivers/fpga/dfl-fme-mgr.c                     |  8 ++++----
  drivers/fpga/fpga-region.c                     |  4 +---
  include/linux/fpga/fpga-mgr.h                  | 18 ++++++++++++------
  include/linux/fpga/fpga-region.h               |  2 +-
  5 files changed, 20 insertions(+), 16 deletions(-)
Documentation/ABI/testing/sysfs-class-fpga-region +2 -2
index bc7ec644acc9a..241359fb74a55 100644
@@ -5,5 +5,5 @@ Contact:	Wu Hao <[email protected]>
  Description:	FPGA region id for compatibility check, e.g. compatibility
  		of the FPGA reconfiguration hardware and image. This value
  		is defined or calculated by the layer that is creating the
-		FPGA region. This interface returns the compat_id value or
-		just error code -ENOENT in case compat_id is not used.
+		FPGA region. This interface returns a uuid value or just
+		error code -ENOENT in case compat_id is not used.
drivers/fpga/dfl-fme-mgr.c +4 -4
index d5861d13b3069..012b72712684c 100644
@@ -273,16 +273,16 @@ static const struct fpga_manager_ops fme_mgr_ops = {
  };
 
  static void fme_mgr_get_compat_id(void __iomem *fme_pr,
-				  struct fpga_compat_id *id)
+				  union fpga_compat_id *id)
  {
-	id->id_l = readq(fme_pr + FME_PR_INTFC_ID_L);
-	id->id_h = readq(fme_pr + FME_PR_INTFC_ID_H);
+	id->id_l = cpu_to_be64(readq(fme_pr + FME_PR_INTFC_ID_L));
+	id->id_h = cpu_to_be64(readq(fme_pr + FME_PR_INTFC_ID_H));
  }
 
  static int fme_mgr_probe(struct platform_device *pdev)
  {
  	struct dfl_fme_mgr_pdata *pdata = dev_get_platdata(&pdev->dev);
-	struct fpga_compat_id *compat_id;
+	union fpga_compat_id *compat_id;
  	struct device *dev = &pdev->dev;
  	struct fme_mgr_priv *priv;
  	struct fpga_manager *mgr;
drivers/fpga/fpga-region.c +1 -3
index a4838715221ff..f1083b5894635 100644
@@ -166,9 +166,7 @@ static ssize_t compat_id_show(struct device *dev,
  	if (!region->compat_id)
  		return -ENOENT;
 
-	return sprintf(buf, "%016llx%016llx\n",
-		       (unsigned long long)region->compat_id->id_h,
-		       (unsigned long long)region->compat_id->id_l);
+	return sprintf(buf, "%pU\n", &region->compat_id->uuid);
  }
 
  static DEVICE_ATTR_RO(compat_id);
include/linux/fpga/fpga-mgr.h +12 -6
index ec2cd8bfceb00..b12f9994932e1 100644
@@ -10,6 +10,7 @@
 
  #include <linux/mutex.h>
  #include <linux/platform_device.h>
+#include <linux/uuid.h>
 
  struct fpga_manager;
  struct sg_table;
@@ -144,14 +145,19 @@ struct fpga_manager_ops {
  #define FPGA_MGR_STATUS_FIFO_OVERFLOW_ERR	BIT(4)
 
  /**
- * struct fpga_compat_id - id for compatibility check
- *
+ * union fpga_compat_id - id for compatibility check
+ * Can be accessed as either:
+ * @uuid: the base uuid_t type
+ * or
   * @id_h: high 64bit of the compat_id
   * @id_l: low 64bit of the compat_id
   */
-struct fpga_compat_id {
-	u64 id_h;
-	u64 id_l;
+union fpga_compat_id {
+	uuid_t uuid;
+	struct {
+		u64 id_h;
+		u64 id_l;
+	};
  };
 
  /**
@@ -169,7 +175,7 @@ struct fpga_manager {
  	struct device dev;
  	struct mutex ref_mutex;
  	enum fpga_mgr_states state;
-	struct fpga_compat_id *compat_id;
+	union fpga_compat_id *compat_id;
  	const struct fpga_manager_ops *mops;
  	void *priv;
  };
include/linux/fpga/fpga-region.h +1 -1
index 27cb706275dba..7cc2ee543efb4 100644
@@ -24,7 +24,7 @@ struct fpga_region {
  	struct list_head bridge_list;
  	struct fpga_manager *mgr;
  	struct fpga_image_info *info;
-	struct fpga_compat_id *compat_id;
+	union fpga_compat_id *compat_id;
  	void *priv;
  	int (*get_bridges)(struct fpga_region *region);
  };
#3 lore raw
Quoted 53 lines · Russ Weight
Quoted 31 lines · On 7/26/21 1:26 PM, [email protected] wrote:
Quoted 21 lines

From: Tom Rix <[email protected]>

An fpga region's compat_id is exported by the sysfs as a 128 bit hex string formed by concatenating two 64 bit values together.

The only user of compat_id is dfl. Its user library opae converts this value into a uuid.

ex/

$ cat /sys/class/fpga_region/region1/compat_id
f3c9941350814aadbced07eb84a6d0bb

Is reported as

$ fpgainfo bmc
...
Pr Interface Id                  : f3c99413-5081-4aad-bced-07eb84a6d0bb

Storing a uuid as 2 64 bit values is vendor specific. And concatenating them together is vendor specific.

Quoted 6 lines

It is better to store and print out as a vendor neutral uuid.

Change fpga_compat_id from a struct to a union. Keep the old 64 bit values for dfl.
Sysfs output is now f3c99413-5081-4aad-bced-07eb84a6d0bb

I'm fowarding feedback from Tim Whisonant, one of the OPAE userspace developers:

Quoted 6 lines

I think that this change to the sysfs for the compat_id node will end up breaking the SDK, which does not expect the '-' characters to be included when parsing the sysfs value. Currently, it is parsed as a raw hex string without regard to any '-' characters. This goes for any "guid" currently exported by sysfs and for what we read in the device MMIO space.

Yes, it will.

And there are other places, like dfl-afu-main.c:afu_id_show()

outputs raw hex that sdk turns into a uuid.

Some options.

If no one but dfl will ever use it, then v1 of patchset.

If others can use it but don't want to change dfl, then v2 of patchset, my favorite.

Quoted 6 lines

Or this one for uuid for everyone, what have been v3 but changed too much.

could dfl change generally to output uuid's to the sysfs ?

this would be generally helpful and a one time disruption to the sdk.

This change limited the output format to uuid_t, but if any hardware doesn't use uuid_t on hardware may have to convert it back from the sysfs output in userspace. Leave it to print hardware values (e.g. from register), and convert it in userspace should be fine too I think.

Thanks
Hao

Quoted 129 lines

Tom

Quoted 12 lines

- Russ

Quoted 9 lines
---
  .../ABI/testing/sysfs-class-fpga-region        |  4 ++--
  drivers/fpga/dfl-fme-mgr.c                     |  8 ++++----
  drivers/fpga/fpga-region.c                     |  4 +---
  include/linux/fpga/fpga-mgr.h                  | 18 ++++++++++++------
  include/linux/fpga/fpga-region.h               |  2 +-
  5 files changed, 20 insertions(+), 16 deletions(-)
Quoted 1 line

Review

Quoted 1 line
(quoted diff) +0 -0

b/Documentation/ABI/testing/sysfs-class-fpga-region

Quoted 8 lines
Quoted 8 lines

index bc7ec644acc9a..241359fb74a55 100644

Documentation/ABI/testing/sysfs-class-fpga-region +0 -1
@@ -5,5 +5,5 @@ Contact:	Wu Hao <[email protected]>
  Description:	FPGA region id for compatibility check, e.g. compatibility
  		of the FPGA reconfiguration hardware and image. This value
  		is defined or calculated by the layer that is creating the
-		FPGA region. This interface returns the compat_id value or
Quoted 8 lines

drivers/fpga/dfl-fme-mgr.c static const struct fpga_manager_ops

Quoted 8 lines
Documentation/ABI/testing/sysfs-class-fpga-region +2 -1
-		just error code -ENOENT in case compat_id is not used.
+		FPGA region. This interface returns a uuid value or just
+		error code -ENOENT in case compat_id is not used.
drivers/fpga/dfl-fme-mgr.c +0 -0
index d5861d13b3069..012b72712684c 100644
@@ -273,16 +273,16 @@ static const struct fpga_manager_ops

fme_mgr_ops = {

Quoted 71 lines
Quoted 71 lines
drivers/fpga/dfl-fme-mgr.c +4 -4
  };
 
  static void fme_mgr_get_compat_id(void __iomem *fme_pr,
-				  struct fpga_compat_id *id)
+				  union fpga_compat_id *id)
  {
-	id->id_l = readq(fme_pr + FME_PR_INTFC_ID_L);
-	id->id_h = readq(fme_pr + FME_PR_INTFC_ID_H);
+	id->id_l = cpu_to_be64(readq(fme_pr + FME_PR_INTFC_ID_L));
+	id->id_h = cpu_to_be64(readq(fme_pr + FME_PR_INTFC_ID_H));
  }
 
  static int fme_mgr_probe(struct platform_device *pdev)
  {
  	struct dfl_fme_mgr_pdata *pdata = dev_get_platdata(&pdev->dev);
-	struct fpga_compat_id *compat_id;
+	union fpga_compat_id *compat_id;
  	struct device *dev = &pdev->dev;
  	struct fme_mgr_priv *priv;
  	struct fpga_manager *mgr;
drivers/fpga/fpga-region.c +1 -3
index a4838715221ff..f1083b5894635 100644
@@ -166,9 +166,7 @@ static ssize_t compat_id_show(struct device *dev,
  	if (!region->compat_id)
  		return -ENOENT;
 
-	return sprintf(buf, "%016llx%016llx\n",
-		       (unsigned long long)region->compat_id->id_h,
-		       (unsigned long long)region->compat_id->id_l);
+	return sprintf(buf, "%pU\n", &region->compat_id->uuid);
  }
 
  static DEVICE_ATTR_RO(compat_id);
include/linux/fpga/fpga-mgr.h +11 -5
index ec2cd8bfceb00..b12f9994932e1 100644
@@ -10,6 +10,7 @@
 
  #include <linux/mutex.h>
  #include <linux/platform_device.h>
+#include <linux/uuid.h>
 
  struct fpga_manager;
  struct sg_table;
@@ -144,14 +145,19 @@ struct fpga_manager_ops {
  #define FPGA_MGR_STATUS_FIFO_OVERFLOW_ERR	BIT(4)
 
  /**
- * struct fpga_compat_id - id for compatibility check
- *
+ * union fpga_compat_id - id for compatibility check
+ * Can be accessed as either:
+ * @uuid: the base uuid_t type
+ * or
   * @id_h: high 64bit of the compat_id
   * @id_l: low 64bit of the compat_id
   */
-struct fpga_compat_id {
-	u64 id_h;
-	u64 id_l;
+union fpga_compat_id {
+	uuid_t uuid;
+	struct {
+		u64 id_h;
+		u64 id_l;
+	};
  };
 
Quoted 11 lines

include/linux/fpga/fpga-

Quoted 11 lines
include/linux/fpga/fpga-mgr.h +1 -1
  /**
@@ -169,7 +175,7 @@ struct fpga_manager {
  	struct device dev;
  	struct mutex ref_mutex;
  	enum fpga_mgr_states state;
-	struct fpga_compat_id *compat_id;
+	union fpga_compat_id *compat_id;
  	const struct fpga_manager_ops *mops;
  	void *priv;
  };
include/linux/fpga/fpga- renamed from include/linux/fpga/fpga-region.h +0 -0

region.h

Quoted 12 lines
Quoted 12 lines

index 27cb706275dba..7cc2ee543efb4 100644

include/linux/fpga/fpga-region.h +1 -1
@@ -24,7 +24,7 @@ struct fpga_region {
  	struct list_head bridge_list;
  	struct fpga_manager *mgr;
  	struct fpga_image_info *info;
-	struct fpga_compat_id *compat_id;
+	union fpga_compat_id *compat_id;
  	void *priv;
  	int (*get_bridges)(struct fpga_region *region);
  };
maintainer
#4 lore raw
Quoted 56 lines · Hao
Quoted 56 lines · Russ Weight
Quoted 31 lines · On 7/26/21 1:26 PM, [email protected] wrote:
Quoted 21 lines

From: Tom Rix <[email protected]>

An fpga region's compat_id is exported by the sysfs as a 128 bit hex string formed by concatenating two 64 bit values together.

The only user of compat_id is dfl. Its user library opae converts this value into a uuid.

ex/

$ cat /sys/class/fpga_region/region1/compat_id
f3c9941350814aadbced07eb84a6d0bb

Is reported as

$ fpgainfo bmc
...
Pr Interface Id                  : f3c99413-5081-4aad-bced-07eb84a6d0bb

Storing a uuid as 2 64 bit values is vendor specific. And concatenating them together is vendor specific.

Quoted 6 lines

It is better to store and print out as a vendor neutral uuid.

Change fpga_compat_id from a struct to a union. Keep the old 64 bit values for dfl.
Sysfs output is now f3c99413-5081-4aad-bced-07eb84a6d0bb

I'm fowarding feedback from Tim Whisonant, one of the OPAE userspace developers:

Quoted 6 lines

I think that this change to the sysfs for the compat_id node will end up breaking the SDK, which does not expect the '-' characters to be included when parsing the sysfs value. Currently, it is parsed as a raw hex string without regard to any '-' characters. This goes for any "guid" currently exported by sysfs and for what we read in the device MMIO space.

Yes, it will.

And there are other places, like dfl-afu-main.c:afu_id_show()

outputs raw hex that sdk turns into a uuid.

Some options.

If no one but dfl will ever use it, then v1 of patchset.

If others can use it but don't want to change dfl, then v2 of patchset, my favorite.

Or this one for uuid for everyone, what have been v3 but changed too much.

Quoted 8 lines
Quoted 3 lines

could dfl change generally to output uuid's to the sysfs ?

this would be generally helpful and a one time disruption to the sdk.

This change limited the output format to uuid_t, but if any hardware doesn't use uuid_t on hardware may have to convert it back from the sysfs output in userspace. Leave it to print hardware values (e.g. from register), and convert it in userspace should be fine too I think.

I'm not entirely sure. I seem to recall there being examples of sysfs files returning different things for different drivers.

That being said it seems largely cosmetic to add the '-' in between.

If it breaks userspace, I'm against it. If you *need* it make a compat_uuid entry or something in that case?

- Moritz

author reviewer
#5 lore raw
Quoted 63 lines · Moritz Fischer
Quoted 55 lines · Hao
Quoted 55 lines · Russ Weight
Quoted 31 lines · On 7/26/21 1:26 PM, [email protected] wrote:
Quoted 21 lines

From: Tom Rix <[email protected]>

An fpga region's compat_id is exported by the sysfs as a 128 bit hex string formed by concatenating two 64 bit values together.

The only user of compat_id is dfl. Its user library opae converts this value into a uuid.

ex/

$ cat /sys/class/fpga_region/region1/compat_id
f3c9941350814aadbced07eb84a6d0bb

Is reported as

$ fpgainfo bmc
...
Pr Interface Id                  : f3c99413-5081-4aad-bced-07eb84a6d0bb

Storing a uuid as 2 64 bit values is vendor specific. And concatenating them together is vendor specific.

Quoted 6 lines

It is better to store and print out as a vendor neutral uuid.

Change fpga_compat_id from a struct to a union. Keep the old 64 bit values for dfl.
Sysfs output is now f3c99413-5081-4aad-bced-07eb84a6d0bb

I'm fowarding feedback from Tim Whisonant, one of the OPAE userspace developers:

Quoted 6 lines

I think that this change to the sysfs for the compat_id node will end up breaking the SDK, which does not expect the '-' characters to be included when parsing the sysfs value. Currently, it is parsed as a raw hex string without regard to any '-' characters. This goes for any "guid" currently exported by sysfs and for what we read in the device MMIO space.

Yes, it will.

And there are other places, like dfl-afu-main.c:afu_id_show()

outputs raw hex that sdk turns into a uuid.

Some options.

If no one but dfl will ever use it, then v1 of patchset.

If others can use it but don't want to change dfl, then v2 of patchset, my favorite.

Or this one for uuid for everyone, what have been v3 but changed too much.

Quoted 7 lines
Quoted 3 lines

could dfl change generally to output uuid's to the sysfs ?

this would be generally helpful and a one time disruption to the sdk.

This change limited the output format to uuid_t, but if any hardware doesn't use uuid_t on hardware may have to convert it back from the sysfs output in userspace. Leave it to print hardware values (e.g. from register), and convert it in userspace should be fine too I think.

Quoted 7 lines

I'm not entirely sure. I seem to recall there being examples of sysfs files returning different things for different drivers.

That being said it seems largely cosmetic to add the '-' in between.

If it breaks userspace, I'm against it. If you *need* it make a compat_uuid entry or something in that case?

My gripe is

For a nominally common interface, compat_id has a vendor specific output.

If for example another vendor wanted to use this field but their natural format was an OF string.

16 bytes of raw hex would not work for them, so they would roll their own.

which defeats the purpose of a common interface.

The language in the docs as-is is vague on the output format.

DFL is the only user of the interface.

So ver 2

https://lore.kernel.org/linux-fpga/[email protected]/

Keeps the output as-is for dfl, so nothing breaks in userspace

And adds flexibility for vendors to output their appropriate natural form.

So compat_id becomes generally useful.

Tom

Quoted 3 lines

- Moritz

maintainer
#6 lore raw
Quoted 91 lines · Tom Rix
Quoted 63 lines · Moritz Fischer
Quoted 55 lines · Hao
Quoted 55 lines · Russ Weight
Quoted 31 lines · On 7/26/21 1:26 PM, [email protected] wrote:
Quoted 21 lines

From: Tom Rix <[email protected]>

An fpga region's compat_id is exported by the sysfs as a 128 bit hex string formed by concatenating two 64 bit values together.

The only user of compat_id is dfl. Its user library opae converts this value into a uuid.

ex/

$ cat /sys/class/fpga_region/region1/compat_id
f3c9941350814aadbced07eb84a6d0bb

Is reported as

$ fpgainfo bmc
...
Pr Interface Id                  : f3c99413-5081-4aad-bced-07eb84a6d0bb

Storing a uuid as 2 64 bit values is vendor specific. And concatenating them together is vendor specific.

Quoted 6 lines

It is better to store and print out as a vendor neutral uuid.

Change fpga_compat_id from a struct to a union. Keep the old 64 bit values for dfl.
Sysfs output is now f3c99413-5081-4aad-bced-07eb84a6d0bb

I'm fowarding feedback from Tim Whisonant, one of the OPAE userspace developers:

Quoted 6 lines

I think that this change to the sysfs for the compat_id node will end up breaking the SDK, which does not expect the '-' characters to be included when parsing the sysfs value. Currently, it is parsed as a raw hex string without regard to any '-' characters. This goes for any "guid" currently exported by sysfs and for what we read in the device MMIO space.

Yes, it will.

And there are other places, like dfl-afu-main.c:afu_id_show()

outputs raw hex that sdk turns into a uuid.

Some options.

If no one but dfl will ever use it, then v1 of patchset.

If others can use it but don't want to change dfl, then v2 of patchset, my favorite.

Or this one for uuid for everyone, what have been v3 but changed too much.

Quoted 7 lines
Quoted 3 lines

could dfl change generally to output uuid's to the sysfs ?

this would be generally helpful and a one time disruption to the sdk.

This change limited the output format to uuid_t, but if any hardware doesn't use uuid_t on hardware may have to convert it back from the sysfs output in userspace. Leave it to print hardware values (e.g. from register), and convert it in userspace should be fine too I think.

Quoted 7 lines

I'm not entirely sure. I seem to recall there being examples of sysfs files returning different things for different drivers.

That being said it seems largely cosmetic to add the '-' in between.

If it breaks userspace, I'm against it. If you *need* it make a compat_uuid entry or something in that case?

My gripe is

For a nominally common interface, compat_id has a vendor specific output.

If for example another vendor wanted to use this field but their natural format was an OF string.

16 bytes of raw hex would not work for them, so they would roll their own.

which defeats the purpose of a common interface.

The language in the docs as-is is vague on the output format.

DFL is the only user of the interface.

So ver 2

Quoted 7 lines

https://lore.kernel.org/linux-fpga/[email protected]/

Keeps the output as-is for dfl, so nothing breaks in userspace

And adds flexibility for vendors to output their appropriate natural form.

So compat_id becomes generally useful.

Mixing types seems be strongly against in Documentation/filesystems/sysfs.rst. So in my opinion there should be a determined format for the output. The concern for this patch is which one is a better format, uuid style or 128 bit raw hex?

And I vote for 128 bit raw hex, as other vendors may not use uuid_t as the identifier, may be an OF string. So we don't have to force them decorate it as the uuid style.

Thanks
Yilun

Quoted 8 lines

Tom

Quoted 3 lines

- Moritz

author reviewer
#7 lore raw
Quoted 97 lines · Xu Yilun
Quoted 89 lines · Tom Rix
Quoted 63 lines · Moritz Fischer
Quoted 55 lines · Hao
Quoted 55 lines · Russ Weight
Quoted 31 lines · On 7/26/21 1:26 PM, [email protected] wrote:
Quoted 21 lines

From: Tom Rix <[email protected]>

An fpga region's compat_id is exported by the sysfs as a 128 bit hex string formed by concatenating two 64 bit values together.

The only user of compat_id is dfl. Its user library opae converts this value into a uuid.

ex/

$ cat /sys/class/fpga_region/region1/compat_id
f3c9941350814aadbced07eb84a6d0bb

Is reported as

$ fpgainfo bmc
...
Pr Interface Id                  : f3c99413-5081-4aad-bced-07eb84a6d0bb

Storing a uuid as 2 64 bit values is vendor specific. And concatenating them together is vendor specific.

Quoted 6 lines

It is better to store and print out as a vendor neutral uuid.

Change fpga_compat_id from a struct to a union. Keep the old 64 bit values for dfl.
Sysfs output is now f3c99413-5081-4aad-bced-07eb84a6d0bb

I'm fowarding feedback from Tim Whisonant, one of the OPAE userspace developers:

Quoted 6 lines

I think that this change to the sysfs for the compat_id node will end up breaking the SDK, which does not expect the '-' characters to be included when parsing the sysfs value. Currently, it is parsed as a raw hex string without regard to any '-' characters. This goes for any "guid" currently exported by sysfs and for what we read in the device MMIO space.

Yes, it will.

And there are other places, like dfl-afu-main.c:afu_id_show()

outputs raw hex that sdk turns into a uuid.

Some options.

If no one but dfl will ever use it, then v1 of patchset.

If others can use it but don't want to change dfl, then v2 of patchset, my favorite.

Or this one for uuid for everyone, what have been v3 but changed too much.

Quoted 7 lines
Quoted 3 lines

could dfl change generally to output uuid's to the sysfs ?

this would be generally helpful and a one time disruption to the sdk.

This change limited the output format to uuid_t, but if any hardware doesn't use uuid_t on hardware may have to convert it back from the sysfs output in userspace. Leave it to print hardware values (e.g. from register), and convert it in userspace should be fine too I think.

Quoted 7 lines

I'm not entirely sure. I seem to recall there being examples of sysfs files returning different things for different drivers.

That being said it seems largely cosmetic to add the '-' in between.

If it breaks userspace, I'm against it. If you *need* it make a compat_uuid entry or something in that case?

My gripe is

For a nominally common interface, compat_id has a vendor specific output.

If for example another vendor wanted to use this field but their natural format was an OF string.

16 bytes of raw hex would not work for them, so they would roll their own.

which defeats the purpose of a common interface.

The language in the docs as-is is vague on the output format.

DFL is the only user of the interface.

So ver 2

Quoted 7 lines

https://lore.kernel.org/linux-fpga/[email protected]/

Keeps the output as-is for dfl, so nothing breaks in userspace

And adds flexibility for vendors to output their appropriate natural form.

So compat_id becomes generally useful.

Quoted 8 lines

Mixing types seems be strongly against in Documentation/filesystems/sysfs.rst. So in my opinion there should be a determined format for the output. The concern for this patch is which one is a better format, uuid style or 128 bit raw hex?

And I vote for 128 bit raw hex, as other vendors may not use uuid_t as the identifier, may be an OF string. So we don't have to force them decorate it as the uuid style.

So you would be ok with v2 of this patchset ?

Tom

Quoted 10 lines

Thanks
Yilun

Quoted 6 lines

Tom

Quoted 2 lines

- Moritz

maintainer
#8 lore raw
Quoted 104 lines · Tom Rix
Quoted 102 lines · Xu Yilun
Quoted 89 lines · Tom Rix
Quoted 63 lines · Moritz Fischer
Quoted 55 lines · Hao
Quoted 55 lines · Russ Weight
Quoted 31 lines · On 7/26/21 1:26 PM, [email protected] wrote:
Quoted 21 lines

From: Tom Rix <[email protected]>

An fpga region's compat_id is exported by the sysfs as a 128 bit hex string formed by concatenating two 64 bit values together.

The only user of compat_id is dfl. Its user library opae converts this value into a uuid.

ex/

$ cat /sys/class/fpga_region/region1/compat_id
f3c9941350814aadbced07eb84a6d0bb

Is reported as

$ fpgainfo bmc
...
Pr Interface Id                  : f3c99413-5081-4aad-bced-07eb84a6d0bb

Storing a uuid as 2 64 bit values is vendor specific. And concatenating them together is vendor specific.

Quoted 6 lines

It is better to store and print out as a vendor neutral uuid.

Change fpga_compat_id from a struct to a union. Keep the old 64 bit values for dfl.
Sysfs output is now f3c99413-5081-4aad-bced-07eb84a6d0bb

I'm fowarding feedback from Tim Whisonant, one of the OPAE userspace developers:

Quoted 6 lines

I think that this change to the sysfs for the compat_id node will end up breaking the SDK, which does not expect the '-' characters to be included when parsing the sysfs value. Currently, it is parsed as a raw hex string without regard to any '-' characters. This goes for any "guid" currently exported by sysfs and for what we read in the device MMIO space.

Yes, it will.

And there are other places, like dfl-afu-main.c:afu_id_show()

outputs raw hex that sdk turns into a uuid.

Some options.

If no one but dfl will ever use it, then v1 of patchset.

If others can use it but don't want to change dfl, then v2 of patchset, my favorite.

Or this one for uuid for everyone, what have been v3 but changed too much.

Quoted 7 lines
Quoted 3 lines

could dfl change generally to output uuid's to the sysfs ?

this would be generally helpful and a one time disruption to the sdk.

This change limited the output format to uuid_t, but if any hardware doesn't use uuid_t on hardware may have to convert it back from the sysfs output in userspace. Leave it to print hardware values (e.g. from register), and convert it in userspace should be fine too I think.

Quoted 7 lines

I'm not entirely sure. I seem to recall there being examples of sysfs files returning different things for different drivers.

That being said it seems largely cosmetic to add the '-' in between.

If it breaks userspace, I'm against it. If you *need* it make a compat_uuid entry or something in that case?

My gripe is

For a nominally common interface, compat_id has a vendor specific output.

If for example another vendor wanted to use this field but their natural format was an OF string.

16 bytes of raw hex would not work for them, so they would roll their own.

which defeats the purpose of a common interface.

The language in the docs as-is is vague on the output format.

DFL is the only user of the interface.

So ver 2

Quoted 7 lines

https://lore.kernel.org/linux-fpga/[email protected]/

Keeps the output as-is for dfl, so nothing breaks in userspace

And adds flexibility for vendors to output their appropriate natural form.

So compat_id becomes generally useful.

Mixing types seems be strongly against in Documentation/filesystems/sysfs.rst. So in my opinion there should be a determined format for the output. The concern for this patch is which one is a better format, uuid style or 128 bit raw hex?

Quoted 5 lines
Quoted 3 lines

And I vote for 128 bit raw hex, as other vendors may not use uuid_t as the identifier, may be an OF string. So we don't have to force them decorate it as the uuid style.

So you would be ok with v2 of this patchset ?

No. I prefer we keep the current implementation. I mean 128 bit raw hex could be a more compatible output format for all vendors, uuid style, string style or others.

Thanks,
Yilun

Quoted 13 lines

Tom

Quoted 10 lines

Thanks
Yilun

Quoted 6 lines

Tom

Quoted 2 lines

- Moritz

author reviewer
#9 lore raw
Quoted 104 lines · Xu Yilun
Quoted 103 lines · Tom Rix
Quoted 102 lines · Xu Yilun
Quoted 89 lines · Tom Rix
Quoted 63 lines · Moritz Fischer
Quoted 55 lines · Hao
Quoted 55 lines · Russ Weight
Quoted 31 lines · On 7/26/21 1:26 PM, [email protected] wrote:
Quoted 21 lines

From: Tom Rix <[email protected]>

An fpga region's compat_id is exported by the sysfs as a 128 bit hex string formed by concatenating two 64 bit values together.

The only user of compat_id is dfl. Its user library opae converts this value into a uuid.

ex/

$ cat /sys/class/fpga_region/region1/compat_id
f3c9941350814aadbced07eb84a6d0bb

Is reported as

$ fpgainfo bmc
...
Pr Interface Id                  : f3c99413-5081-4aad-bced-07eb84a6d0bb

Storing a uuid as 2 64 bit values is vendor specific. And concatenating them together is vendor specific.

Quoted 6 lines

It is better to store and print out as a vendor neutral uuid.

Change fpga_compat_id from a struct to a union. Keep the old 64 bit values for dfl.
Sysfs output is now f3c99413-5081-4aad-bced-07eb84a6d0bb

I'm fowarding feedback from Tim Whisonant, one of the OPAE userspace developers:

Quoted 6 lines

I think that this change to the sysfs for the compat_id node will end up breaking the SDK, which does not expect the '-' characters to be included when parsing the sysfs value. Currently, it is parsed as a raw hex string without regard to any '-' characters. This goes for any "guid" currently exported by sysfs and for what we read in the device MMIO space.

Yes, it will.

And there are other places, like dfl-afu-main.c:afu_id_show()

outputs raw hex that sdk turns into a uuid.

Some options.

If no one but dfl will ever use it, then v1 of patchset.

If others can use it but don't want to change dfl, then v2 of patchset, my favorite.

Or this one for uuid for everyone, what have been v3 but changed too much.

Quoted 7 lines
Quoted 3 lines

could dfl change generally to output uuid's to the sysfs ?

this would be generally helpful and a one time disruption to the sdk.

This change limited the output format to uuid_t, but if any hardware doesn't use uuid_t on hardware may have to convert it back from the sysfs output in userspace. Leave it to print hardware values (e.g. from register), and convert it in userspace should be fine too I think.

Quoted 7 lines

I'm not entirely sure. I seem to recall there being examples of sysfs files returning different things for different drivers.

That being said it seems largely cosmetic to add the '-' in between.

If it breaks userspace, I'm against it. If you *need* it make a compat_uuid entry or something in that case?

My gripe is

For a nominally common interface, compat_id has a vendor specific output.

If for example another vendor wanted to use this field but their natural format was an OF string.

16 bytes of raw hex would not work for them, so they would roll their own.

which defeats the purpose of a common interface.

The language in the docs as-is is vague on the output format.

DFL is the only user of the interface.

So ver 2

Quoted 7 lines

https://lore.kernel.org/linux-fpga/[email protected]/

Keeps the output as-is for dfl, so nothing breaks in userspace

And adds flexibility for vendors to output their appropriate natural form.

So compat_id becomes generally useful.

Mixing types seems be strongly against in Documentation/filesystems/sysfs.rst. So in my opinion there should be a determined format for the output. The concern for this patch is which one is a better format, uuid style or 128 bit raw hex?

Quoted 7 lines
Quoted 4 lines
Quoted 3 lines

And I vote for 128 bit raw hex, as other vendors may not use uuid_t as the identifier, may be an OF string. So we don't have to force them decorate it as the uuid style.

So you would be ok with v2 of this patchset ?

No. I prefer we keep the current implementation. I mean 128 bit raw hex could be a more compatible output format for all vendors, uuid style, string style or others.

How would 128 bit raw hex be compatible if a vendor's natural format was an OF string ?

Why would they even use compat_id ?

Tom

Quoted 14 lines

Thanks,
Yilun

Quoted 10 lines

Tom

Quoted 8 lines

Thanks
Yilun

Quoted 5 lines

Tom

Quoted 2 lines

- Moritz

maintainer
#10 lore raw
Quoted 110 lines · Tom Rix
Quoted 108 lines · Xu Yilun
Quoted 107 lines · Tom Rix
Quoted 97 lines · Xu Yilun
Quoted 89 lines · Tom Rix
Quoted 63 lines · Moritz Fischer
Quoted 55 lines · Hao
Quoted 55 lines · Russ Weight
Quoted 31 lines · On 7/26/21 1:26 PM, [email protected] wrote:
Quoted 21 lines

From: Tom Rix <[email protected]>

An fpga region's compat_id is exported by the sysfs as a 128 bit hex string formed by concatenating two 64 bit values together.

The only user of compat_id is dfl. Its user library opae converts this value into a uuid.

ex/

$ cat /sys/class/fpga_region/region1/compat_id
f3c9941350814aadbced07eb84a6d0bb

Is reported as

$ fpgainfo bmc
...
Pr Interface Id                  : f3c99413-5081-4aad-bced-07eb84a6d0bb

Storing a uuid as 2 64 bit values is vendor specific. And concatenating them together is vendor specific.

Quoted 6 lines

It is better to store and print out as a vendor neutral uuid.

Change fpga_compat_id from a struct to a union. Keep the old 64 bit values for dfl.
Sysfs output is now f3c99413-5081-4aad-bced-07eb84a6d0bb

I'm fowarding feedback from Tim Whisonant, one of the OPAE userspace developers:

Quoted 6 lines

I think that this change to the sysfs for the compat_id node will end up breaking the SDK, which does not expect the '-' characters to be included when parsing the sysfs value. Currently, it is parsed as a raw hex string without regard to any '-' characters. This goes for any "guid" currently exported by sysfs and for what we read in the device MMIO space.

Yes, it will.

And there are other places, like dfl-afu-main.c:afu_id_show()

outputs raw hex that sdk turns into a uuid.

Some options.

If no one but dfl will ever use it, then v1 of patchset.

If others can use it but don't want to change dfl, then v2 of patchset, my favorite.

Or this one for uuid for everyone, what have been v3 but changed too much.

Quoted 7 lines
Quoted 3 lines

could dfl change generally to output uuid's to the sysfs ?

this would be generally helpful and a one time disruption to the sdk.

This change limited the output format to uuid_t, but if any hardware doesn't use uuid_t on hardware may have to convert it back from the sysfs output in userspace. Leave it to print hardware values (e.g. from register), and convert it in userspace should be fine too I think.

Quoted 7 lines

I'm not entirely sure. I seem to recall there being examples of sysfs files returning different things for different drivers.

That being said it seems largely cosmetic to add the '-' in between.

If it breaks userspace, I'm against it. If you *need* it make a compat_uuid entry or something in that case?

My gripe is

For a nominally common interface, compat_id has a vendor specific output.

If for example another vendor wanted to use this field but their natural format was an OF string.

16 bytes of raw hex would not work for them, so they would roll their own.

which defeats the purpose of a common interface.

The language in the docs as-is is vague on the output format.

DFL is the only user of the interface.

So ver 2

Quoted 7 lines

https://lore.kernel.org/linux-fpga/[email protected]/

Keeps the output as-is for dfl, so nothing breaks in userspace

And adds flexibility for vendors to output their appropriate natural form.

So compat_id becomes generally useful.

Quoted 8 lines

Mixing types seems be strongly against in Documentation/filesystems/sysfs.rst. So in my opinion there should be a determined format for the output. The concern for this patch is which one is a better format, uuid style or 128 bit raw hex?

And I vote for 128 bit raw hex, as other vendors may not use uuid_t as the identifier, may be an OF string. So we don't have to force them decorate it as the uuid style.

So you would be ok with v2 of this patchset ?

Quoted 8 lines
Quoted 3 lines

No. I prefer we keep the current implementation. I mean 128 bit raw hex could be a more compatible output format for all vendors, uuid style, string style or others.

How would 128 bit raw hex be compatible if a vendor's natural format was an OF string ?

Why would they even use compat_id ?

As I mentioned before, I assume there should be a unified output format for all vendors. So we need to choose one from raw hex, uuid_t, string and all other formats. Raw hex is the fundamental format, which could be further interpreted by user as a uuid_t, a string or other objects.

Thanks,
Yilun

Quoted 17 lines

Tom

Quoted 14 lines

Thanks,
Yilun

Quoted 10 lines

Tom

Quoted 8 lines

Thanks
Yilun

Quoted 5 lines

Tom

Quoted 2 lines

- Moritz

author reviewer
#11 lore raw
Quoted 113 lines · Xu Yilun
Quoted 112 lines · Tom Rix
Quoted 111 lines · Xu Yilun
Quoted 103 lines · Tom Rix
Quoted 102 lines · Xu Yilun
Quoted 89 lines · Tom Rix
Quoted 63 lines · Moritz Fischer
Quoted 55 lines · Hao
Quoted 55 lines · Russ Weight
Quoted 31 lines · On 7/26/21 1:26 PM, [email protected] wrote:
Quoted 21 lines

From: Tom Rix <[email protected]>

An fpga region's compat_id is exported by the sysfs as a 128 bit hex string formed by concatenating two 64 bit values together.

The only user of compat_id is dfl. Its user library opae converts this value into a uuid.

ex/

$ cat /sys/class/fpga_region/region1/compat_id
f3c9941350814aadbced07eb84a6d0bb

Is reported as

$ fpgainfo bmc
...
Pr Interface Id                  : f3c99413-5081-4aad-bced-07eb84a6d0bb

Storing a uuid as 2 64 bit values is vendor specific. And concatenating them together is vendor specific.

Quoted 6 lines

It is better to store and print out as a vendor neutral uuid.

Change fpga_compat_id from a struct to a union. Keep the old 64 bit values for dfl.
Sysfs output is now f3c99413-5081-4aad-bced-07eb84a6d0bb

I'm fowarding feedback from Tim Whisonant, one of the OPAE userspace developers:

Quoted 6 lines

I think that this change to the sysfs for the compat_id node will end up breaking the SDK, which does not expect the '-' characters to be included when parsing the sysfs value. Currently, it is parsed as a raw hex string without regard to any '-' characters. This goes for any "guid" currently exported by sysfs and for what we read in the device MMIO space.

Yes, it will.

And there are other places, like dfl-afu-main.c:afu_id_show()

outputs raw hex that sdk turns into a uuid.

Some options.

If no one but dfl will ever use it, then v1 of patchset.

If others can use it but don't want to change dfl, then v2 of patchset, my favorite.

Or this one for uuid for everyone, what have been v3 but changed too much.

Quoted 7 lines
Quoted 3 lines

could dfl change generally to output uuid's to the sysfs ?

this would be generally helpful and a one time disruption to the sdk.

This change limited the output format to uuid_t, but if any hardware doesn't use uuid_t on hardware may have to convert it back from the sysfs output in userspace. Leave it to print hardware values (e.g. from register), and convert it in userspace should be fine too I think.

Quoted 7 lines

I'm not entirely sure. I seem to recall there being examples of sysfs files returning different things for different drivers.

That being said it seems largely cosmetic to add the '-' in between.

If it breaks userspace, I'm against it. If you *need* it make a compat_uuid entry or something in that case?

My gripe is

For a nominally common interface, compat_id has a vendor specific output.

If for example another vendor wanted to use this field but their natural format was an OF string.

16 bytes of raw hex would not work for them, so they would roll their own.

which defeats the purpose of a common interface.

The language in the docs as-is is vague on the output format.

DFL is the only user of the interface.

So ver 2

Quoted 7 lines

https://lore.kernel.org/linux-fpga/[email protected]/

Keeps the output as-is for dfl, so nothing breaks in userspace

And adds flexibility for vendors to output their appropriate natural form.

So compat_id becomes generally useful.

Mixing types seems be strongly against in Documentation/filesystems/sysfs.rst. So in my opinion there should be a determined format for the output. The concern for this patch is which one is a better format, uuid style or 128 bit raw hex?

Quoted 4 lines
Quoted 3 lines

And I vote for 128 bit raw hex, as other vendors may not use uuid_t as the identifier, may be an OF string. So we don't have to force them decorate it as the uuid style.

So you would be ok with v2 of this patchset ?

No. I prefer we keep the current implementation. I mean 128 bit raw hex could be a more compatible output format for all vendors, uuid style, string style or others.

Quoted 8 lines
Quoted 4 lines

How would 128 bit raw hex be compatible if a vendor's natural format was an OF string ?

Why would they even use compat_id ?

As I mentioned before, I assume there should be a unified output format for all vendors. So we need to choose one from raw hex, uuid_t, string and all other formats. Raw hex is the fundamental format, which could be further interpreted by user as a uuid_t, a string or other objects.

Having one format is not a requirement, the format is not listed in the docs.

How would converting an OF string to hex work and why would a vendor want to display it as hex ?

For the user, instead of reading an OF string directly they would be required to decrypt it.

So it they had a compat_id they would not use this one, they would stick it somewhere else.

Defeating the purpose of a having it a common area.

Tom

Quoted 19 lines

Thanks,
Yilun

Quoted 15 lines

Tom

Quoted 13 lines

Thanks,
Yilun

Quoted 10 lines

Tom

Quoted 8 lines

Thanks
Yilun

Quoted 5 lines

Tom

Quoted 2 lines

- Moritz

maintainer
#12 lore raw
Quoted 118 lines · Tom Rix
Quoted 116 lines · Xu Yilun
Quoted 115 lines · Tom Rix
Quoted 104 lines · Xu Yilun
Quoted 103 lines · Tom Rix
Quoted 102 lines · Xu Yilun
Quoted 89 lines · Tom Rix
Quoted 63 lines · Moritz Fischer
Quoted 55 lines · Hao
Quoted 55 lines · Russ Weight
Quoted 31 lines · On 7/26/21 1:26 PM, [email protected] wrote:
Quoted 21 lines

From: Tom Rix <[email protected]>

An fpga region's compat_id is exported by the sysfs as a 128 bit hex string formed by concatenating two 64 bit values together.

The only user of compat_id is dfl. Its user library opae converts this value into a uuid.

ex/

$ cat /sys/class/fpga_region/region1/compat_id
f3c9941350814aadbced07eb84a6d0bb

Is reported as

$ fpgainfo bmc
...
Pr Interface Id                  : f3c99413-5081-4aad-bced-07eb84a6d0bb

Storing a uuid as 2 64 bit values is vendor specific. And concatenating them together is vendor specific.

Quoted 6 lines

It is better to store and print out as a vendor neutral uuid.

Change fpga_compat_id from a struct to a union. Keep the old 64 bit values for dfl.
Sysfs output is now f3c99413-5081-4aad-bced-07eb84a6d0bb

I'm fowarding feedback from Tim Whisonant, one of the OPAE userspace developers:

Quoted 6 lines

I think that this change to the sysfs for the compat_id node will end up breaking the SDK, which does not expect the '-' characters to be included when parsing the sysfs value. Currently, it is parsed as a raw hex string without regard to any '-' characters. This goes for any "guid" currently exported by sysfs and for what we read in the device MMIO space.

Yes, it will.

And there are other places, like dfl-afu-main.c:afu_id_show()

outputs raw hex that sdk turns into a uuid.

Some options.

If no one but dfl will ever use it, then v1 of patchset.

If others can use it but don't want to change dfl, then v2 of patchset, my favorite.

Or this one for uuid for everyone, what have been v3 but changed too much.

Quoted 7 lines
Quoted 3 lines

could dfl change generally to output uuid's to the sysfs ?

this would be generally helpful and a one time disruption to the sdk.

This change limited the output format to uuid_t, but if any hardware doesn't use uuid_t on hardware may have to convert it back from the sysfs output in userspace. Leave it to print hardware values (e.g. from register), and convert it in userspace should be fine too I think.

Quoted 7 lines

I'm not entirely sure. I seem to recall there being examples of sysfs files returning different things for different drivers.

That being said it seems largely cosmetic to add the '-' in between.

If it breaks userspace, I'm against it. If you *need* it make a compat_uuid entry or something in that case?

My gripe is

For a nominally common interface, compat_id has a vendor specific output.

If for example another vendor wanted to use this field but their natural format was an OF string.

16 bytes of raw hex would not work for them, so they would roll their own.

which defeats the purpose of a common interface.

The language in the docs as-is is vague on the output format.

DFL is the only user of the interface.

So ver 2

Quoted 7 lines

https://lore.kernel.org/linux-fpga/[email protected]/

Keeps the output as-is for dfl, so nothing breaks in userspace

And adds flexibility for vendors to output their appropriate natural form.

So compat_id becomes generally useful.

Mixing types seems be strongly against in Documentation/filesystems/sysfs.rst. So in my opinion there should be a determined format for the output. The concern for this patch is which one is a better format, uuid style or 128 bit raw hex?

Quoted 7 lines
Quoted 4 lines
Quoted 3 lines

And I vote for 128 bit raw hex, as other vendors may not use uuid_t as the identifier, may be an OF string. So we don't have to force them decorate it as the uuid style.

So you would be ok with v2 of this patchset ?

No. I prefer we keep the current implementation. I mean 128 bit raw hex could be a more compatible output format for all vendors, uuid style, string style or others.

How would 128 bit raw hex be compatible if a vendor's natural format was an OF string ?

Quoted 8 lines
Quoted 5 lines
Quoted 1 line

Why would they even use compat_id ?

As I mentioned before, I assume there should be a unified output format for all vendors. So we need to choose one from raw hex, uuid_t, string and all other formats. Raw hex is the fundamental format, which could be further interpreted by user as a uuid_t, a string or other objects.

Having one format is not a requirement, the format is not listed in the docs.

My understanding comes from the "Mixing types" description in Documentation/filesystems/sysfs.txt, I assume a sysfs node should not output different data types in different conditions.

Thanks,
Yilun

Quoted 33 lines

How would converting an OF string to hex work and why would a vendor want to display it as hex ?

For the user, instead of reading an OF string directly they would be required to decrypt it.

So it they had a compat_id they would not use this one, they would stick it somewhere else.

Defeating the purpose of a having it a common area.

Tom

Quoted 19 lines

Thanks,
Yilun

Quoted 15 lines

Tom

Quoted 13 lines

Thanks,
Yilun

Quoted 10 lines

Tom

Quoted 8 lines

Thanks
Yilun

Quoted 5 lines

Tom

Quoted 2 lines

- Moritz

#13 lore raw
In reply to [email protected]
I love your patch! Perhaps something to improve:

Hi,

I love your patch! Perhaps something to improve:

[auto build test WARNING on linus/master]
[also build test WARNING on v5.14-rc3 next-20210726]
[If your patch is applied to the wrong git tree, kindly drop us a note. And when submitting patch, we suggest to use '--base' as documented in
https://git-scm.com/docs/git-format-patch]

url:    https://github.com/0day-ci/linux/commits/trix-redhat-com/fpga-region-handle-compat_id-as-an-uuid/20210727-042850
base:   https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git ff1176468d368232b684f75e82563369208bc371
config: x86_64-randconfig-s032-20210726 (attached as .config)
compiler: gcc-10 (Ubuntu 10.3.0-1ubuntu1~20.04) 10.3.0
reproduce:
        # apt-get install sparse
        # sparse version: v0.6.3-341-g8af24329-dirty
        # https://github.com/0day-ci/linux/commit/fc6e727a3f214d2b60561c3accc1f054982e2281
        git remote add linux-review https://github.com/0day-ci/linux
        git fetch --no-tags linux-review trix-redhat-com/fpga-region-handle-compat_id-as-an-uuid/20210727-042850
        git checkout fc6e727a3f214d2b60561c3accc1f054982e2281
        # save the attached .config to linux build tree
        make W=1 C=1 CF='-fdiagnostic-prefix -D__CHECK_ENDIAN__' ARCH=x86_64 

If you fix the issue, kindly add following tag as appropriate

sparse warnings: (new ones prefixed by >>)

>> drivers/fpga/dfl-fme-mgr.c:278:18: sparse: sparse: incorrect type in assignment (different base types) @@     expected unsigned long long [usertype] id_l @@     got restricted __be64 [usertype] @@
   drivers/fpga/dfl-fme-mgr.c:278:18: sparse:     expected unsigned long long [usertype] id_l
   drivers/fpga/dfl-fme-mgr.c:278:18: sparse:     got restricted __be64 [usertype]
>> drivers/fpga/dfl-fme-mgr.c:279:18: sparse: sparse: incorrect type in assignment (different base types) @@     expected unsigned long long [usertype] id_h @@     got restricted __be64 [usertype] @@

drivers/fpga/dfl-fme-mgr.c:279:18: sparse: expected unsigned long long [usertype] id_h
drivers/fpga/dfl-fme-mgr.c:279:18: sparse: got restricted __be64 [usertype]

vim +278 drivers/fpga/dfl-fme-mgr.c

274
275 static void fme_mgr_get_compat_id(void __iomem *fme_pr,
276 union fpga_compat_id *id)
277 {

 > 278		id->id_l = cpu_to_be64(readq(fme_pr + FME_PR_INTFC_ID_L));
 > 279		id->id_h = cpu_to_be64(readq(fme_pr + FME_PR_INTFC_ID_H));

280 }
281

---