nvme sq associations
Subsystems (3)
cover nvme sq associations
The NVMe specification allows for namespaces with different performance characteristics, as well as allowing IOs submissions to any namespace via any non-empty submission queue. However, sharing queue resources between namespaces with different performance characteristics can cause undesired behavior (e.g. head-of-line-blocking for IOs that target a high-performance namespace behind IOs that target a low performance namespace via the same queue). In addition, the lack of hardware queue isolation support can cause “noisy neighbor” type problems for applications issuing IOs to different namespaces of the same controller. This problem may be especially pronounced in multi-tenant environments such as the ones provided by cloud services.
The NVMe 1.4 specification has introduced some optional features (NVM sets and SQ associations) that can be utilized to improve this situation provided these features are supported by both controllers and host drivers. Namespaces can be assigned to NVM sets (by performance characteristics, for example) which each NVM set having its own set of associated queues.
This patch series proposes a simple implementation of NVM sets and SQ associations for the NVMe host PCI module. A controller that supports these features, along with a sufficient number of queue pairs (at least one per NVM set), will have the available queue pairs associated uniformly across each NVM set. IO requests directed at the controller will honor the namespace/NVM set/queue association by virtue of each NVM set having its own blk-mq tagset associated with it.
Andrey Nikitin (3):
nvme: split admin queue in pci
nvme: add NVM set structures
nvme: implement SQ associations
drivers/nvme/host/core.c | 18 +- drivers/nvme/host/fc.c | 1 + drivers/nvme/host/nvme.h | 10 + drivers/nvme/host/pci.c | 363 +++++++++++++++++++++++++------------ drivers/nvme/host/rdma.c | 1 + drivers/nvme/host/tcp.c | 1 + drivers/nvme/target/loop.c | 1 + include/linux/nvme.h | 11 +- 8 files changed, 286 insertions(+), 120 deletions(-)
Signature · 7 lines
2.32.0 _______________________________________________ Linux-nvme mailing list [email protected] http://lists.infradead.org/mailman/listinfo/linux-nvme
RFC PATCH 2/3 nvme: add NVM set structures
This patch adds NVM set and SQ association structure as defined by NVMe 1.4 specification along with a helper function to check for NVM sets and SQ associations support presented by the controller.
--- drivers/nvme/host/core.c | 1 + drivers/nvme/host/nvme.h | 8 ++++++++ include/linux/nvme.h | 11 +++++++++-- 3 files changed, 18 insertions(+), 2 deletions(-)
drivers/nvme/host/core.c +1 -0
@@ -2889,6 +2889,7 @@ static int nvme_init_identify(struct nvme_ctrl *ctrl) ctrl->kas =le16_to_cpu (id->kas); ctrl->max_namespaces =le32_to_cpu (id->mnan); ctrl->ctratt =le32_to_cpu (id->ctratt); + ctrl->nsetidmax =le16_to_cpu (id->nsetidmax);if (id->rtd3e) {/* us -> s */
drivers/nvme/host/nvme.h +8 -0
@@ -290,6 +290,7 @@ struct nvme_ctrl {u32 oaes;u32 aen_result;u32 ctratt; +u16 nsetidmax;unsigned int shutdown_timeout;unsigned int kato;bool subsystem;
@@ -630,6 +631,13 @@ static inline bool nvme_is_aen_req(u16 qid, __u16 command_id)nvme_tag_from_cid (command_id) >=NVME_AQ_BLK_MQ_DEPTH ; } +static inline bool nvme_is_qassoc_supported (struct nvme_ctrl *ctrl) +{ +return (ctrl->ctratt &NVME_CTRL_ATTR_NVM_SETS ) && + (ctrl->ctratt &NVME_CTRL_ATTR_SQ_ASSOC ) && + ctrl->nsetidmax >0 ; +} +void nvme_complete_rq (struct request *req);blk_status_t nvme_host_path_error (struct request *req);bool nvme_cancel_request (struct request *req,void *data,bool reserved);
include/linux/nvme.h +9 -2
@@ -25,6 +25,7 @@#define NVME_RDMA_IP_PORT 4420#define NVME_NSID_ALL 0xffffffff +#define NVME_MAX_QID 0xffffenum nvme_subsys_type {NVME_NQN_DISC =1 ,/* Discovery type target subsystem */
@@ -225,7 +226,9 @@ enum {enum nvme_ctrl_attr {NVME_CTRL_ATTR_HID_128_BIT = (1 <<0 ), +NVME_CTRL_ATTR_NVM_SETS = (1 <<2 ),NVME_CTRL_ATTR_TBKAS = (1 <<6 ), +NVME_CTRL_ATTR_SQ_ASSOC = (1 <<8 ), };struct nvme_id_ctrl {
@@ -276,7 +279,8 @@ struct nvme_id_ctrl {__le32 sanicap;__le32 hmminds;__le16 hmmaxd; -__u8 rsvd338[4 ]; +__le16 nsetidmax; +__le16 endgidmax;__u8 anatt;__u8 anacap;__le32 anagrpmax;
@@ -420,6 +424,7 @@ enum {NVME_ID_CNS_CTRL =0x01 ,NVME_ID_CNS_NS_ACTIVE_LIST =0x02 ,NVME_ID_CNS_NS_DESC_LIST =0x03 , +NVME_ID_CNS_NVMSET_LIST =0x04 ,NVME_ID_CNS_CS_NS =0x05 ,NVME_ID_CNS_CS_CTRL =0x06 , NVME_ID_CNS_NS_PRESENT_LIST = 0x10,
@@ -1166,7 +1171,9 @@ struct nvme_create_sq {__le16 qsize;__le16 sq_flags;__le16 cqid; -__u32 rsvd12[4 ]; +__le16 nvmsetid; +__u16 rsvd3; +__u32 rsvd13[3 ]; };struct nvme_delete_queue {
Signature · 7 lines
2.32.0 _______________________________________________ Linux-nvme mailing list [email protected] http://lists.infradead.org/mailman/listinfo/linux-nvme
RFC PATCH 3/3 nvme: implement SQ associations
In reply to Andrey NikitinThis patch implements SQ association feature for PCI host. If the controller indicates support for NVM sets and SQ associations and has a sufficient number of queues supported then each NVM set gets its own blk-mq tagset and queues are distributed uniformly across NVM sets.
If the number of mxi-x vectors supported by a controller is less than the total number of queues for all NVM sets the vectors will be shared by queues associated with different NVM sets, they’ll be assigned in a round-robin fashion.
--- drivers/nvme/host/core.c | 17 ++- drivers/nvme/host/fc.c | 1 + drivers/nvme/host/nvme.h | 2 + drivers/nvme/host/pci.c | 215 ++++++++++++++++++++++++++++--------- drivers/nvme/host/rdma.c | 1 + drivers/nvme/host/tcp.c | 1 + drivers/nvme/target/loop.c | 1 + 7 files changed, 182 insertions(+), 56 deletions(-)
drivers/nvme/host/core.c +13 -4
@@ -412,10 +412,16 @@ EXPORT_SYMBOL_GPL(nvme_cancel_request);void nvme_cancel_tagset (struct nvme_ctrl *ctrl) { -if (ctrl->tagset) { -blk_mq_tagset_busy_iter (ctrl->tagset, +int i; + +if (!ctrl->tagset) { +return ; + } + +for (i =0 ; i < ctrl->nr_tagsets; i++) { +blk_mq_tagset_busy_iter (&ctrl->tagset[i], nvme_cancel_request, ctrl); -blk_mq_tagset_wait_completed_request (ctrl->tagset); +blk_mq_tagset_wait_completed_request (&ctrl->tagset[i]); } }EXPORT_SYMBOL_GPL (nvme_cancel_tagset);
@@ -3716,6 +3722,7 @@ static void nvme_alloc_ns(struct nvme_ctrl *ctrl, unsigned nsid,struct gendisk *disk;struct nvme_id_ns *id;int node = ctrl->numa_node; +int tagset_idx;if (nvme_identify_ns (ctrl, nsid, ids, &id))return ;
@@ -3724,7 +3731,9 @@ static void nvme_alloc_ns(struct nvme_ctrl *ctrl, unsigned nsid,if (!ns) goto out_free_id; - disk =blk_mq_alloc_disk (ctrl->tagset, ns); + tagset_idx = id->nvmsetid && id->nvmsetid <= ctrl->nr_tagsets ? + id->nvmsetid -1 :0 ; + disk =blk_mq_alloc_disk (&ctrl->tagset[tagset_idx], ns);if (IS_ERR (disk)) goto out_free_ns; disk->fops = &nvme_bdev_ops;
drivers/nvme/host/fc.c +1 -0
@@ -2889,6 +2889,7 @@ nvme_fc_create_io_queues(struct nvme_fc_ctrl *ctrl)return ret; ctrl->ctrl.tagset = &ctrl->tag_set; + ctrl->ctrl.nr_tagsets =1 ; ctrl->ctrl.connect_q =blk_mq_init_queue (&ctrl->tag_set);if (IS_ERR (ctrl->ctrl.connect_q)) {
drivers/nvme/host/nvme.h +2 -0
@@ -235,6 +235,8 @@ struct nvme_ctrl {struct device *dev;int instance;int numa_node; +int nr_tagsets; +int nr_tagset_queues;struct blk_mq_tag_set *tagset;struct blk_mq_tag_set *admin_tagset;struct list_head namespaces;
drivers/nvme/host/pci.c +163 -52
387 lines not on this page · raw message
drivers/nvme/host/rdma.c +1 -0
@@ -977,6 +977,7 @@ static int nvme_rdma_configure_io_queues(struct nvme_rdma_ctrl *ctrl, bool new) goto out_free_io_queues; } + ctrl->ctrl.nr_tagsets =1 ; ctrl->ctrl.connect_q =blk_mq_init_queue (&ctrl->tag_set);if (IS_ERR (ctrl->ctrl.connect_q)) { ret =PTR_ERR (ctrl->ctrl.connect_q);
drivers/nvme/host/tcp.c +1 -0
@@ -1803,6 +1803,7 @@ static int nvme_tcp_configure_io_queues(struct nvme_ctrl *ctrl, bool new) goto out_free_io_queues; } + ctrl->nr_tagsets =1 ; ctrl->connect_q =blk_mq_init_queue (ctrl->tagset);if (IS_ERR (ctrl->connect_q)) { ret =PTR_ERR (ctrl->connect_q);
drivers/nvme/target/loop.c +1 -0
@@ -536,6 +536,7 @@ static int nvme_loop_create_io_queues(struct nvme_loop_ctrl *ctrl) ctrl->tag_set.nr_hw_queues = ctrl->ctrl.queue_count -1 ; ctrl->tag_set.timeout =NVME_IO_TIMEOUT ; ctrl->ctrl.tagset = &ctrl->tag_set; + ctrl->ctrl.nr_tagsets =1 ; ret =blk_mq_alloc_tag_set (&ctrl->tag_set);if (ret)
Signature · 7 lines
2.32.0 _______________________________________________ Linux-nvme mailing list [email protected] http://lists.infradead.org/mailman/listinfo/linux-nvme
RFC PATCH 1/3 nvme: split admin queue in pci
In reply to Andrey NikitinTo determine the number of required IO queues it may be needed to send admin commands. To facilitate that process admin queue is split from the array of IO queues and allocation of IO queues is moved to reset routine.
--- drivers/nvme/host/pci.c | 162 +++++++++++++++++++++++----------------- 1 file changed, 93 insertions(+), 69 deletions(-)
drivers/nvme/host/pci.c +93 -69
@@ -108,12 +108,47 @@ struct nvme_queue;static void nvme_dev_disable (struct nvme_dev *dev,bool shutdown);static bool __nvme_disable_io_queues (struct nvme_dev *dev,u8 opcode); +/* +* An NVM Express queue. Each device has at least two (one for admin +* commands and one for I/O commands). +*/ +struct nvme_queue { +struct nvme_dev *dev; +spinlock_t sq_lock; +void *sq_cmds; +/* only used for poll queues: */ +spinlock_t cq_poll_lock____cacheline_aligned_in_smp ; +struct nvme_completion *cqes; +dma_addr_t sq_dma_addr; +dma_addr_t cq_dma_addr; +u32 __iomem *q_db; +u32 q_depth; +u16 cq_vector; +u16 sq_tail; +u16 last_sq_tail; +u16 cq_head; +u16 qid; +u8 cq_phase; +u8 sqes; +unsigned long flags; +#define NVMEQ_ENABLED 0 +#define NVMEQ_SQ_CMB 1 +#define NVMEQ_DELETE_ERROR 2 +#define NVMEQ_POLLED 3 +u32 *dbbuf_sq_db; +u32 *dbbuf_cq_db; +u32 *dbbuf_sq_ei; +u32 *dbbuf_cq_ei; +struct completion delete_done; +}; +/* * Represents an NVM Express device. Each nvme_dev is a PCI function. */ struct nvme_dev {struct nvme_queue *queues;struct blk_mq_tag_set tagset; +struct nvme_queue admin_queue;struct blk_mq_tag_set admin_tagset;u32 __iomem *dbs;struct device *dev;
@@ -181,40 +216,6 @@ static inline struct nvme_dev *to_nvme_dev(struct nvme_ctrl *ctrl) return container_of(ctrl, struct nvme_dev, ctrl); } -/* -* An NVM Express queue. Each device has at least two (one for admin -* commands and one for I/O commands). -*/ -struct nvme_queue { -struct nvme_dev *dev; -spinlock_t sq_lock; -void *sq_cmds; -/* only used for poll queues: */ -spinlock_t cq_poll_lock____cacheline_aligned_in_smp ; -struct nvme_completion *cqes; -dma_addr_t sq_dma_addr; -dma_addr_t cq_dma_addr; -u32 __iomem *q_db; -u32 q_depth; -u16 cq_vector; -u16 sq_tail; -u16 last_sq_tail; -u16 cq_head; -u16 qid; -u8 cq_phase; -u8 sqes; -unsigned long flags; -#define NVMEQ_ENABLED 0 -#define NVMEQ_SQ_CMB 1 -#define NVMEQ_DELETE_ERROR 2 -#define NVMEQ_POLLED 3 -u32 *dbbuf_sq_db; -u32 *dbbuf_cq_db; -u32 *dbbuf_sq_ei; -u32 *dbbuf_cq_ei; -struct completion delete_done; -}; -/* * The nvme_iod describes the data in an I/O. *
@@ -235,9 +236,14 @@ struct nvme_iod {struct scatterlist *sg; }; +static struct nvme_queue *nvme_get_queue (struct nvme_dev *dev,unsigned int qid) +{ +return qid ==0 ? &dev->admin_queue : &dev->queues[qid -1 ]; +} +static inline unsigned int nvme_dbbuf_size (struct nvme_dev *dev) { -return dev->nr_allocated_queues *8 * dev->db_stride; +return dev->ctrl.queue_count *8 * dev->db_stride; }static int nvme_dbbuf_dma_alloc (struct nvme_dev *dev)
@@ -322,7 +328,7 @@ static void nvme_dbbuf_set(struct nvme_dev *dev)nvme_dbbuf_dma_free (dev);for (i =1 ; i <= dev->online_queues; i++) -nvme_dbbuf_free (&dev->queues[i]); +nvme_dbbuf_free (nvme_get_queue (dev, i)); } }
@@ -396,7 +402,7 @@ static int nvme_admin_init_hctx(struct blk_mq_hw_ctx *hctx, void *data, unsigned int hctx_idx) {struct nvme_dev *dev = data; -struct nvme_queue *nvmeq = &dev->queues[0 ]; +struct nvme_queue *nvmeq = &dev->admin_queue;WARN_ON (hctx_idx !=0 );WARN_ON (dev->admin_tagset.tags[0 ] != hctx->tags);
@@ -409,19 +415,34 @@ static int nvme_init_hctx(struct blk_mq_hw_ctx *hctx, void *data, unsigned int hctx_idx) {struct nvme_dev *dev = data; -struct nvme_queue *nvmeq = &dev->queues[hctx_idx +1 ]; +struct nvme_queue *nvmeq = &dev->queues[hctx_idx];WARN_ON (dev->tagset.tags[hctx_idx] != hctx->tags); hctx->driver_data = nvmeq;return 0 ; } +static int nvme_admin_init_request (struct blk_mq_tag_set *set,struct request *req, +unsigned int hctx_idx,unsigned int numa_node) +{ +struct nvme_dev *dev = set->driver_data; +struct nvme_iod *iod =blk_mq_rq_to_pdu (req); +struct nvme_queue *nvmeq = &dev->admin_queue; + +BUG_ON (!nvmeq); + iod->nvmeq = nvmeq; + +nvme_req (req)->ctrl = &dev->ctrl; +nvme_req (req)->cmd = &iod->cmd; +return 0 ; +} +static int nvme_init_request (struct blk_mq_tag_set *set,struct request *req,unsigned int hctx_idx,unsigned int numa_node) {struct nvme_dev *dev = set->driver_data;struct nvme_iod *iod =blk_mq_rq_to_pdu (req); -int queue_idx = (set == &dev->tagset) ? hctx_idx +1 :0 ; +int queue_idx = hctx_idx;struct nvme_queue *nvmeq = &dev->queues[queue_idx];BUG_ON (!nvmeq);
@@ -1109,7 +1130,7 @@ static int nvme_poll(struct blk_mq_hw_ctx *hctx)static void nvme_pci_submit_async_event (struct nvme_ctrl *ctrl) {struct nvme_dev *dev =to_nvme_dev (ctrl); -struct nvme_queue *nvmeq = &dev->queues[0 ]; +struct nvme_queue *nvmeq = &dev->admin_queue;struct nvme_command c = { }; c.common.opcode = nvme_admin_async_event;
@@ -1377,7 +1398,7 @@ static void nvme_free_queues(struct nvme_dev *dev, int lowest)for (i = dev->ctrl.queue_count -1 ; i >= lowest; i--) { dev->ctrl.queue_count--; -nvme_free_queue (&dev->queues[i]); +nvme_free_queue (nvme_get_queue (dev, i)); } }
@@ -1406,12 +1427,12 @@ static void nvme_suspend_io_queues(struct nvme_dev *dev)int i;for (i = dev->ctrl.queue_count -1 ; i >0 ; i--) -nvme_suspend_queue (&dev->queues[i]); +nvme_suspend_queue (nvme_get_queue (dev, i)); }static void nvme_disable_admin_queue (struct nvme_dev *dev,bool shutdown) { -struct nvme_queue *nvmeq = &dev->queues[0 ]; +struct nvme_queue *nvmeq = &dev->admin_queue;if (shutdown)nvme_shutdown_ctrl (&dev->ctrl);
@@ -1432,9 +1453,11 @@ static void nvme_reap_pending_cqes(struct nvme_dev *dev)int i;for (i = dev->ctrl.queue_count -1 ; i >0 ; i--) { -spin_lock (&dev->queues[i].cq_poll_lock); -nvme_process_cq (&dev->queues[i]); -spin_unlock (&dev->queues[i].cq_poll_lock); +struct nvme_queue *nvmeq =nvme_get_queue (dev, i); + +spin_lock (&nvmeq->cq_poll_lock); +nvme_process_cq (nvmeq); +spin_unlock (&nvmeq->cq_poll_lock); } }
@@ -1491,7 +1514,7 @@ static int nvme_alloc_sq_cmds(struct nvme_dev *dev, struct nvme_queue *nvmeq,static int nvme_alloc_queue (struct nvme_dev *dev,int qid,int depth) { -struct nvme_queue *nvmeq = &dev->queues[qid]; +struct nvme_queue *nvmeq =nvme_get_queue (dev, qid);if (dev->ctrl.queue_count > qid)return 0 ;
@@ -1631,7 +1654,7 @@ static const struct blk_mq_ops nvme_mq_admin_ops = { .queue_rq = nvme_queue_rq, .complete = nvme_pci_complete_rq, .init_hctx = nvme_admin_init_hctx, - .init_request = nvme_init_request, + .init_request = nvme_admin_init_request, .timeout = nvme_timeout, };
@@ -1746,7 +1769,7 @@ static int nvme_pci_configure_admin_queue(struct nvme_dev *dev) dev->ctrl.numa_node =dev_to_node (dev->dev); - nvmeq = &dev->queues[0 ]; + nvmeq = &dev->admin_queue; aqa = nvmeq->q_depth -1 ; aqa |= aqa <<16 ;
@@ -1793,7 +1816,7 @@ static int nvme_create_io_queues(struct nvme_dev *dev)for (i = dev->online_queues; i <= max; i++) {bool polled = i > rw_queues; - ret =nvme_create_queue (&dev->queues[i], i, polled); + ret =nvme_create_queue (nvme_get_queue (dev, i), i, polled);if (ret)break ; }
@@ -2245,7 +2268,7 @@ static unsigned int nvme_max_io_queues(struct nvme_dev *dev)static int nvme_setup_io_queues (struct nvme_dev *dev) { -struct nvme_queue *adminq = &dev->queues[0 ]; +struct nvme_queue *adminq = &dev->admin_queue;struct pci_dev *pdev =to_pci_dev (dev->dev);unsigned int nr_io_queues;unsigned long size;
@@ -2258,7 +2281,18 @@ static int nvme_setup_io_queues(struct nvme_dev *dev) dev->nr_write_queues = write_queues; dev->nr_poll_queues = poll_queues; - nr_io_queues = dev->nr_allocated_queues -1 ; + nr_io_queues =nvme_max_io_queues (dev); +if (nr_io_queues != dev->nr_allocated_queues) { + dev->nr_allocated_queues = nr_io_queues; + +kfree (dev->queues); + dev->queues =kcalloc_node (dev->nr_allocated_queues, +sizeof (struct nvme_queue ),GFP_KERNEL , +dev_to_node (dev->dev)); +if (!dev->queues) +return -ENOMEM ; + } + result =nvme_set_queue_count (&dev->ctrl, &nr_io_queues);if (result <0 )return result;
@@ -2404,13 +2438,13 @@ static bool __nvme_disable_io_queues(struct nvme_dev *dev, u8 opcode) retry: timeout =NVME_ADMIN_TIMEOUT ;while (nr_queues >0 ) { -if (nvme_delete_queue (&dev->queues[nr_queues], opcode)) +if (nvme_delete_queue (nvme_get_queue (dev, nr_queues), opcode))break ; nr_queues--; sent++; }while (sent) { -struct nvme_queue *nvmeq = &dev->queues[nr_queues + sent]; +struct nvme_queue *nvmeq =nvme_get_queue (dev, nr_queues + sent); timeout =wait_for_completion_io_timeout (&nvmeq->delete_done, timeout);
@@ -2606,7 +2640,7 @@ static void nvme_dev_disable(struct nvme_dev *dev, bool shutdown)nvme_disable_admin_queue (dev, shutdown); }nvme_suspend_io_queues (dev); -nvme_suspend_queue (&dev->queues[0 ]); +nvme_suspend_queue (&dev->admin_queue);nvme_pci_disable (dev);nvme_reap_pending_cqes (dev);
@@ -2779,6 +2813,10 @@ static void nvme_reset_work(struct work_struct *work) dev->ctrl.opal_dev =NULL ; } + result =nvme_setup_io_queues (dev); +if (result) + goto out; +if (dev->ctrl.oacs &NVME_CTRL_OACS_DBBUF_SUPP ) { result =nvme_dbbuf_dma_alloc (dev);if (result)
@@ -2792,10 +2830,6 @@ static void nvme_reset_work(struct work_struct *work) goto out; } - result =nvme_setup_io_queues (dev); -if (result) - goto out; -/* * Keep the controller around but remove all namespaces if we don't have * any working I/O queue.
@@ -2970,14 +3004,6 @@ static int nvme_probe(struct pci_dev *pdev, const struct pci_device_id *id)if (!dev)return -ENOMEM ; - dev->nr_write_queues = write_queues; - dev->nr_poll_queues = poll_queues; - dev->nr_allocated_queues =nvme_max_io_queues (dev) +1 ; - dev->queues =kcalloc_node (dev->nr_allocated_queues, -sizeof (struct nvme_queue ),GFP_KERNEL , node); -if (!dev->queues) - goto free; - dev->dev =get_device (&pdev->dev);pci_set_drvdata (pdev, dev);
@@ -3041,8 +3067,6 @@ static int nvme_probe(struct pci_dev *pdev, const struct pci_device_id *id)nvme_dev_unmap (dev); put_pci:put_device (dev->dev); - free: -kfree (dev->queues);kfree (dev);return result; }
Signature · 7 lines
2.32.0 _______________________________________________ Linux-nvme mailing list [email protected] http://lists.infradead.org/mailman/listinfo/linux-nvme
Keith Busch
maintainerQuoted 17 lines · Andrey Nikitin
The NVMe specification allows for namespaces with different performance characteristics, as well as allowing IOs submissions to any namespace via any non-empty submission queue. However, sharing queue resources between namespaces with different performance characteristics can cause undesired behavior (e.g. head-of-line-blocking for IOs that target a high-performance namespace behind IOs that target a low performance namespace via the same queue). In addition, the lack of hardware queue isolation support can cause “noisy neighbor” type problems for applications issuing IOs to different namespaces of the same controller. This problem may be especially pronounced in multi-tenant environments such as the ones provided by cloud services.
The NVMe 1.4 specification has introduced some optional features (NVM sets and SQ associations) that can be utilized to improve this situation provided these features are supported by both controllers and host drivers. Namespaces can be assigned to NVM sets (by performance characteristics, for example) which each NVM set having its own set of associated queues.
Quoted 7 lines
This patch series proposes a simple implementation of NVM sets and SQ associations for the NVMe host PCI module. A controller that supports these features, along with a sufficient number of queue pairs (at least one per NVM set), will have the available queue pairs associated uniformly across each NVM set. IO requests directed at the controller will honor the namespace/NVM set/queue association by virtue of each NVM set having its own blk-mq tagset associated with it.
Different submission queue groups per NVM Set sounds right for this feature, but I'm not sure it makes sense for these to have their own completion queues: completions from different sets would try to schedule on the same CPU. I think it should be more efficient to break the 1:1 SQ:CQ pairing, and instead have all the SQs with the same CPU affinity share a single CQ so that completions from different namespaces could be handled in a single interrupt.
_______________________________________________
Linux-nvme mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/linux-nvme
Quoted 9 lines · Keith Busch
Different submission queue groups per NVM Set sounds right for this feature, but I'm not sure it makes sense for these to have their own completion queues: completions from different sets would try to schedule on the same CPU. I think it should be more efficient to break the 1:1
SQ:CQ pairing, and instead have all the SQs with the same CPU affinity share a single CQ so that completions from different namespaces could be handled in a single interrupt.
Can this be an incremental improvement ?
Cheers,
Ben.
_______________________________________________
Linux-nvme mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/linux-nvme
Quoted 11 lines · Benjamin Herrenschmidt
Quoted 9 lines · Keith Busch
Different submission queue groups per NVM Set sounds right for this feature, but I'm not sure it makes sense for these to have their own completion queues: completions from different sets would try to schedule on the same CPU. I think it should be more efficient to break the 1:1
SQ:CQ pairing, and instead have all the SQs with the same CPU affinity share a single CQ so that completions from different namespaces could be handled in a single interrupt.
Quoted 1 line
Can this be an incremental improvement ?
Honestly I'd rather not merge this whole patchset at all. It is a completly frinde feature for a totally misdesigned part of the NVMe spec. Until actual controller in the hands of prosumers support anything like that I'm very reluctant to bloat the driver fast path for it.
_______________________________________________
Linux-nvme mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/linux-nvme
Quoted 11 lines · Andrey Nikitin
The NVMe specification allows for namespaces with different performance characteristics, as well as allowing IOs submissions to any namespace via any non-empty submission queue. However, sharing queue resources between namespaces with different performance characteristics can cause undesired behavior (e.g. head-of-line-blocking for IOs that target a high-performance namespace behind IOs that target a low performance namespace via the same queue). In addition, the lack of hardware queue isolation support can cause “noisy neighbor” type problems for applications issuing IOs to different namespaces of the same controller. This problem may be especially pronounced in multi-tenant environments such as the ones provided by cloud services.
For RFC such as this you need to provide a quantitative data for different usecases for targeted (e.g. noisy neighbor problem) and non targeted workloads (e.g. standard fio perf) and also the performance impact of this change on the the hot path.
_______________________________________________
Linux-nvme mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/linux-nvme
Sagi Grimberg
maintainerQuoted 13 lines
Quoted 12 lines
The NVMe specification allows for namespaces with different performance characteristics, as well as allowing IOs submissions to any namespace via any non-empty submission queue. However, sharing queue resources between namespaces with different performance characteristics can cause undesired behavior (e.g. head-of-line-blocking for IOs that target a high-performance namespace behind IOs that target a low performance namespace via the same queue). In addition, the lack of hardware queue isolation support can cause “noisy neighbor” type problems for applications issuing IOs to different namespaces of the same controller. This problem may be especially pronounced in multi-tenant environments such as the ones provided by cloud services.
Quoted 4 lines
For RFC such as this you need to provide a quantitative data for different usecases for targeted (e.g. noisy neighbor problem) and non targeted workloads (e.g. standard fio perf) and also the performance impact of this change on the the hot path.
Agreed.
_______________________________________________
Linux-nvme mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/linux-nvme