iavf: Add support for VIRTCHNL_VF_OFFLOAD_VLAN_V2
PATCH 1/1 iavf: Add support for VIRTCHNL_VF_OFFLOAD_VLAN_V2
Changes required for iavf patch "Add support for VIRTCHNL_VF_OFFLOAD_VLAN_V2" to work properly.
--- include/linux/avf/virtchnl.h | 330 +++++++++++++++++++++++++++++++++++ 1 file changed, 330 insertions(+)
include/linux/avf/virtchnl.h +330 -0
@@ -141,6 +141,15 @@ enum virtchnl_ops {VIRTCHNL_OP_DEL_RSS_CFG =46 ,VIRTCHNL_OP_ADD_FDIR_FILTER =47 ,VIRTCHNL_OP_DEL_FDIR_FILTER =48 , +VIRTCHNL_OP_GET_OFFLOAD_VLAN_V2_CAPS =51 , +VIRTCHNL_OP_ADD_VLAN_V2 =52 , +VIRTCHNL_OP_DEL_VLAN_V2 =53 , +VIRTCHNL_OP_ENABLE_VLAN_STRIPPING_V2 =54 , +VIRTCHNL_OP_DISABLE_VLAN_STRIPPING_V2 =55 , +VIRTCHNL_OP_ENABLE_VLAN_INSERTION_V2 =56 , +VIRTCHNL_OP_DISABLE_VLAN_INSERTION_V2 =57 , +VIRTCHNL_OP_ENABLE_VLAN_FILTERING_V2 =58 , +VIRTCHNL_OP_DISABLE_VLAN_FILTERING_V2 =59 , VIRTCHNL_OP_MAX, };
@@ -246,6 +255,7 @@ VIRTCHNL_CHECK_STRUCT_LEN(16, virtchnl_vsi_resource);#define VIRTCHNL_VF_OFFLOAD_REQ_QUEUES BIT(6)/* used to negotiate communicating link speeds in Mbps */ #define VIRTCHNL_VF_CAP_ADV_LINK_SPEED BIT(7) +#define VIRTCHNL_VF_OFFLOAD_VLAN_V2 BIT(15)#define VIRTCHNL_VF_OFFLOAD_VLAN BIT(16)#define VIRTCHNL_VF_OFFLOAD_RX_POLLING BIT(17)#define VIRTCHNL_VF_OFFLOAD_RSS_PCTYPE_V2 BIT(18)
@@ -475,6 +485,326 @@ struct virtchnl_vlan_filter_list {VIRTCHNL_CHECK_STRUCT_LEN (6 , virtchnl_vlan_filter_list); +/* VIRTCHNL_OP_ADD_VLAN_V2 +* VIRTCHNL_OP_DEL_VLAN_V2 +* +* VF sends these messages to add/del one or more VLAN tag filters for Rx +* traffic. +* +* The PF attempts to add the filters and returns status. +* +* The VF should only ever attempt to add/del virtchnl_vlan_filter(s) using the +* supported fields negotiated via VIRTCHNL_OP_GET_OFFLOAD_VLAN_V2_CAPS. +*/ +struct virtchnl_vlan_filter_list_v2 { +u16 vport_id; +u16 num_elements; +u8 pad[4 ]; +struct virtchnl_vlan_filter *filters; +}; + +/* VIRTCHNL_OP_ENABLE_VLAN_STRIPPING_V2 +* VIRTCHNL_OP_DISABLE_VLAN_STRIPPING_V2 +* VIRTCHNL_OP_ENABLE_VLAN_INSERTION_V2 +* VIRTCHNL_OP_DISABLE_VLAN_INSERTION_V2 +* +* VF sends this message to enable or disable VLAN stripping or insertion. It +* also needs to specify an ethertype. The VF knows which VLAN ethertypes are +* allowed and whether or not it's allowed to enable/disable the specific +* offload via the VIRTCHNL_OP_GET_OFFLOAD_VLAN_V2_CAPS message. The VF needs to +* parse the virtchnl_vlan_caps.offloads fields to determine which offload +* messages are allowed. +* +* For example, if the PF populates the virtchnl_vlan_caps.offloads in the +* following manner the VF will be allowed to enable and/or disable 0x8100 inner +* VLAN insertion and/or stripping via the opcodes listed above. Inner in this +* case means the outer most or single VLAN from the VF's perspective. This is +* because no outer offloads are supported. See the comments above the +* virtchnl_vlan_supported_caps structure for more details. +* +* virtchnl_vlan_caps.offloads.stripping_support.inner = +* VIRTCHNL_VLAN_TOGGLE | +* VIRTCHNL_VLAN_ETHERTYPE_8100; +* +* virtchnl_vlan_caps.offloads.insertion_support.inner = +* VIRTCHNL_VLAN_TOGGLE | +* VIRTCHNL_VLAN_ETHERTYPE_8100; +* In order to enable inner (again note that in this case inner is the outer +* most or single VLAN from the VF's perspective) VLAN stripping for 0x8100 +* VLANs, the VF would populate the virtchnl_vlan_setting structure in the +* following manner and send the VIRTCHNL_OP_ENABLE_VLAN_STRIPPING_V2 message. +* virtchnl_vlan_setting.inner_ethertype_setting = +* VIRTCHNL_VLAN_ETHERTYPE_8100; +* +* virtchnl_vlan_setting.vport_id = vport_id or vsi_id assigned to the VF on +* initialization. +* +* The reason that VLAN TPID(s) are not being used for the +* outer_ethertype_setting and inner_ethertype_setting fields is because it's +* possible a device could support VLAN insertion and/or stripping offload on +* multiple ethertypes concurrently, so this method allows a VF to request +* multiple ethertypes in one message using the virtchnl_vlan_support +* enumeration. +* +* For example, if the PF populates the virtchnl_vlan_caps.offloads in the +* following manner the VF will be allowed to enable 0x8100 and 0x88a8 outer +* VLAN insertion and stripping simultaneously. The +* virtchnl_vlan_caps.offloads.ethertype_match field will also have to be +* populated based on what the PF can support. +* +* virtchnl_vlan_caps.offloads.stripping_support.outer = +* VIRTCHNL_VLAN_TOGGLE | +* VIRTCHNL_VLAN_ETHERTYPE_8100 | +* VIRTCHNL_VLAN_ETHERTYPE_88A8 | +* VIRTCHNL_VLAN_ETHERTYPE_AND; +* virtchnl_vlan_caps.offloads.insertion_support.outer = +* VIRTCHNL_VLAN_TOGGLE | +* VIRTCHNL_VLAN_ETHERTYPE_8100 | +* VIRTCHNL_VLAN_ETHERTYPE_88A8 | +* VIRTCHNL_VLAN_ETHERTYPE_AND; +* In order to enable outer VLAN stripping for 0x8100 and 0x88a8 VLANs, the VF +* would populate the virthcnl_vlan_offload_structure in the following manner +* and send the VIRTCHNL_OP_ENABLE_VLAN_STRIPPING_V2 message. +* +* virtchnl_vlan_setting.outer_ethertype_setting = +* VIRTHCNL_VLAN_ETHERTYPE_8100 | +* VIRTHCNL_VLAN_ETHERTYPE_88A8; +* +* virtchnl_vlan_setting.vport_id = vport_id or vsi_id assigned to the VF on +* initialization. +* +* There is also the case where a PF and the underlying hardware can support +* VLAN offloads on multiple ethertypes, but not concurrently. For example, if +* the PF populates the virtchnl_vlan_caps.offloads in the following manner the +* VF will be allowed to enable and/or disable 0x8100 XOR 0x88a8 outer VLAN +* offloads. The ethertypes must match for stripping and insertion. +* +* virtchnl_vlan_caps.offloads.stripping_support.outer = +* VIRTCHNL_VLAN_TOGGLE | +* VIRTCHNL_VLAN_ETHERTYPE_8100 | +* VIRTCHNL_VLAN_ETHERTYPE_88A8 | +* VIRTCHNL_VLAN_ETHERTYPE_XOR; +* virtchnl_vlan_caps.offloads.insertion_support.outer = +* VIRTCHNL_VLAN_TOGGLE | +* VIRTCHNL_VLAN_ETHERTYPE_8100 | +* VIRTCHNL_VLAN_ETHERTYPE_88A8 | +* VIRTCHNL_VLAN_ETHERTYPE_XOR; +* virtchnl_vlan_caps.offloads.ethertype_match = +* VIRTCHNL_ETHERTYPE_STRIPPING_MATCHES_INSERTION; +* +* In order to enable outer VLAN stripping for 0x88a8 VLANs, the VF would +* populate the virtchnl_vlan_setting structure in the following manner and send +* the VIRTCHNL_OP_ENABLE_VLAN_STRIPPING_V2. Also, this will change the +* ethertype for VLAN insertion if it's enabled. So, for completeness, a +* VIRTCHNL_OP_ENABLE_VLAN_INSERTION_V2 with the same ethertype should be sent. +* +* virtchnl_vlan_setting.outer_ethertype_setting = VIRTHCNL_VLAN_ETHERTYPE_88A8; +* +* virtchnl_vlan_setting.vport_id = vport_id or vsi_id assigned to the VF on +* initialization. +* +* VIRTCHNL_OP_ENABLE_VLAN_FILTERING_V2 +* VIRTCHNL_OP_DISABLE_VLAN_FILTERING_V2 +* +* VF sends this message to enable or disable VLAN filtering. It also needs to +* specify an ethertype. The VF knows which VLAN ethertypes are allowed and +* whether or not it's allowed to enable/disable filtering via the +* VIRTCHNL_OP_GET_OFFLOAD_VLAN_V2_CAPS message. The VF needs to +* parse the virtchnl_vlan_caps.filtering fields to determine which, if any, +* filtering messages are allowed. +* For example, if the PF populates the virtchnl_vlan_caps.filtering in the +* following manner the VF will be allowed to enable/disable 0x8100 and 0x88a8 +* outer VLAN filtering together. Note, that the VIRTCHNL_VLAN_ETHERTYPE_AND +* means that all filtering ethertypes will to be enabled and disabled together +* regardless of the request from the VF. This means that the underlying +* hardware only supports VLAN filtering for all VLAN the specified ethertypes +* or none of them. +* +* virtchnl_vlan_caps.filtering.filtering_support.outer = +* VIRTCHNL_VLAN_TOGGLE | +* VIRTCHNL_VLAN_ETHERTYPE_8100 | +* VIRTHCNL_VLAN_ETHERTYPE_88A8 | +* VIRTCHNL_VLAN_ETHERTYPE_9100 | +* VIRTCHNL_VLAN_ETHERTYPE_AND; +* +* In order to enable outer VLAN filtering for 0x88a8 and 0x8100 VLANs (0x9100 +* VLANs aren't supported by the VF driver), the VF would populate the +* virtchnl_vlan_setting structure in the following manner and send the +* VIRTCHNL_OP_ENABLE_VLAN_FILTERING_V2. The same message format would be used +* to disable outer VLAN filtering for 0x88a8 and 0x8100 VLANs, but the +* VIRTCHNL_OP_DISABLE_VLAN_FILTERING_V2 opcode is used. +* +* virtchnl_vlan_setting.outer_ethertype_setting = +* VIRTCHNL_VLAN_ETHERTYPE_8100 | +* VIRTCHNL_VLAN_ETHERTYPE_88A8; +* +*/ +struct virtchnl_vlan_setting { +u32 outer_ethertype_setting; +u32 inner_ethertype_setting; +u16 vport_id; +u8 pad[6 ]; +}; + +VIRTCHNL_CHECK_STRUCT_LEN (16 , virtchnl_vlan_setting); + +/* This enum is used for all of the VIRTCHNL_VF_OFFLOAD_VLAN_V2_CAPS related +* structures and opcodes. +* +* VIRTCHNL_VLAN_UNSUPPORTED - This field is not supported and if a VF driver +* populates it the PF should return VIRTCHNL_STATUS_ERR_NOT_SUPPORTED. +* +* VIRTCHNL_VLAN_ETHERTYPE_8100 - This field supports 0x8100 ethertype. +* VIRTCHNL_VLAN_ETHERTYPE_88A8 - This field supports 0x88A8 ethertype. +* +* VIRTCHNL_VLAN_TAG_LOCATION_L2TAG1 - Used to tell the VF to insert and/or +* strip the VLAN tag using the L2TAG1 field of the Tx/Rx descriptors. +* +* VIRTCHNL_VLAN_TAG_LOCATION_L2TAG2 - Used to tell the VF to insert hardware +* offloaded VLAN tags using the L2TAG2 field of the Tx descriptor. +* +* VIRTCHNL_VLAN_TAG_LOCATION_L2TAG2 - Used to tell the VF to strip hardware +* offloaded VLAN tags using the L2TAG2_2 field of the Rx descriptor. +* +* VIRTCHNL_VLAN_TOGGLE - This field is used to say whether a +* certain VLAN capability can be toggled. For example if the underlying PF/CP +* allows the VF to toggle VLAN filtering, stripping, and/or insertion it should +* set this bit along with the supported ethertypes. +*/ +enum virtchnl_vlan_support { +VIRTCHNL_VLAN_UNSUPPORTED =0 , +VIRTCHNL_VLAN_ETHERTYPE_8100 =0x00000001 , +VIRTCHNL_VLAN_ETHERTYPE_88A8 =0x00000002 , +VIRTCHNL_VLAN_TAG_LOCATION_L2TAG1 =0x00000100 , +VIRTCHNL_VLAN_TAG_LOCATION_L2TAG2 =0x00000200 , +VIRTCHNL_VLAN_TAG_LOCATION_L2TAG2_2 =0x00000400 , +VIRTCHNL_VLAN_TOGGLE =0x80000000 +}; + +/* This structure is used as part of the VIRTCHNL_OP_GET_OFFLOAD_VLAN_V2_CAPS +* for filtering, insertion, and stripping capabilities. +* +* If only outer capabilities are supported (for filtering, insertion, and/or +* stripping) then this refers to the outer most or single VLAN from the VF's +* perspective. +* +* If only inner capabilities are supported (for filtering, insertion, and/or +* stripping) then this refers to the outer most or single VLAN from the VF's +* perspective. Functionally this is the same as if only outer capabilities are +* supported. The VF driver is just forced to use the inner fields when +* adding/deleting filters and enabling/disabling offloads (if supported). +* +* If both outer and inner capabilities are supported (for filtering, insertion, +* and/or stripping) then outer refers to the outer most or single VLAN and +* inner refers to the second VLAN, if it exists, in the packet. +* +* There is no support for tunneled VLAN offloads, so outer or inner are never +* referring to a tunneled packet from the VF's perspective. +*/ +struct virtchnl_vlan_supported_caps { +u32 outer; +u32 inner; +}; + +/* The PF populates these fields based on the supported VLAN filtering. If a +* field is VIRTCHNL_VLAN_UNSUPPORTED then it's not supported and the PF will +* reject any VIRTCHNL_OP_ADD_VLAN_V2 or VIRTCHNL_OP_DEL_VLAN_V2 messages using +* the unsupported fields. +* +* Also, a VF is only allowed to toggle its VLAN filtering setting if the +* VIRTCHNL_VLAN_TOGGLE bit is set. +* +* The ethertype(s) specified in the ethertype_init field are the ethertypes +* enabled for VLAN filtering. VLAN filtering in this case refers to the outer +* most VLAN from the VF's perspective. If both inner and outer filtering are +* allowed then ethertype_init only refers to the outer most VLAN as only +* VLAN ethertype supported for inner VLAN filtering is +* VIRTCHNL_VLAN_ETHERTYPE_8100. By default, inner VLAN filtering is disabled +* when both inner and outer filtering are allowed. +* +* The max_filters field tells the VF how many VLAN filters it's allowed to have +* at any one time. If it exceeds this amount and tries to add another filter, +* then the request will be rejected by the PF. To prevent failures, the VF +* should keep track of how many VLAN filters it has added and not attempt to +* add more than max_filters. +*/ +struct virtchnl_vlan_filtering_caps { +struct virtchnl_vlan_supported_caps filtering_support; +u32 ethertype_init; +u16 max_filters; +u8 pad[2 ]; +}; + +VIRTCHNL_CHECK_STRUCT_LEN (16 , virtchnl_vlan_filtering_caps); + +/* The PF populates these fields based on the supported VLAN offloads. If a +* field is VIRTCHNL_VLAN_UNSUPPORTED then it's not supported and the PF will +* reject any VIRTCHNL_OP_ENABLE_VLAN_STRIPPING_V2 or +* VIRTCHNL_OP_DISABLE_VLAN_STRIPPING_V2 messages using the unsupported fields. +* +* Also, a VF is only allowed to toggle its VLAN offload setting if the +* VIRTCHNL_VLAN_TOGGLE_ALLOWED bit is set. +* +* The VF driver needs to be aware of how the tags are stripped by hardware and +* inserted by the VF driver based on the level of offload support. The PF will +* populate these fields based on where the VLAN tags are expected to be +* offloaded via the VIRTHCNL_VLAN_TAG_LOCATION_* bits. The VF will need to +* interpret these fields. See the definition of the +* VIRTCHNL_VLAN_TAG_LOCATION_* bits above the virtchnl_vlan_support +* enumeration. +*/ +struct virtchnl_vlan_offload_caps { +struct virtchnl_vlan_supported_caps stripping_support; +struct virtchnl_vlan_supported_caps insertion_support; +u32 ethertype_init; +u8 ethertype_match; +u8 pad[3 ]; +}; + +VIRTCHNL_CHECK_STRUCT_LEN (24 , virtchnl_vlan_offload_caps); + +/* VIRTCHNL_OP_GET_OFFLOAD_VLAN_V2_CAPS +* VF sends this message to determine its VLAN capabilities. +* +* PF will mark which capabilities it supports based on hardware support and +* current configuration. For example, if a port VLAN is configured the PF will +* not allow outer VLAN filtering, stripping, or insertion to be configured so +* it will block these features from the VF. +* +* The VF will need to cross reference its capabilities with the PFs +* capabilities in the response message from the PF to determine the VLAN +* support. +*/ +struct virtchnl_vlan_caps { +struct virtchnl_vlan_filtering_caps filtering; +struct virtchnl_vlan_offload_caps offloads; +}; + +VIRTCHNL_CHECK_STRUCT_LEN (40 , virtchnl_vlan_caps); + +struct virtchnl_vlan { +u16 tci;/* tci[15:13] = PCP and tci[11:0] = VID */ +u16 tci_mask;/* only valid if VIRTCHNL_VLAN_FILTER_MASK set in +* filtering caps +*/ +u16 tpid;/* 0x8100, 0x88a8, etc. and only type(s) set in +* filtering caps. Note that tpid here does not refer to +* VIRTCHNL_VLAN_ETHERTYPE_*, but it refers to the +* actual 2-byte VLAN TPID +*/ +u8 pad[2 ]; +}; + +VIRTCHNL_CHECK_STRUCT_LEN (8 , virtchnl_vlan); + +struct virtchnl_vlan_filter { +struct virtchnl_vlan inner; +struct virtchnl_vlan outer; +u8 pad[16 ]; +}; + +VIRTCHNL_CHECK_STRUCT_LEN (32 , virtchnl_vlan_filter); +/* VIRTCHNL_OP_CONFIG_PROMISCUOUS_MODE * VF sends VSI id and flags. * PF returns status code in retval.
Signature · 1 line
2.27.0
Nguyen
PATCH 1/1 iavf: Add support for VIRTCHNL_VF_OFFLOAD_VLAN_V2
Quoted 10 lines
-----Original Message-----
From: Intel-wired-lan <[email protected]> On Behalf Of Karen Sornek
Sent: Wednesday, September 29, 2021 6:37 AM
To: intel-wired-lan at lists.osuosl.org
Cc: Sornek, Karen <[email protected]>
Subject: [Intel-wired-lan] [PATCH net-next v1] iavf: Add support forVIRTCHNL_VF_OFFLOAD_VLAN_V2
Why is this the same title as the other patch? As this is for the virtchnl file, it should use 'virtchnl:' and reflect what this patch is doing.
Quoted 3 lines
Changes required for iavf patch "Add support for
VIRTCHNL_VF_OFFLOAD_VLAN_V2"
to work properly.
Please explain what this patch is introducing; more information is needed here.
Quoted 8 lines
Signed-off-by Brett Creeley <[email protected]>Signed-off-by Karen Sornek <[email protected]>--- include/linux/avf/virtchnl.h | 330 +++++++++++++++++++++++++++++++++++ 1 file changed, 330 insertions(+)include/linux/avf/virtchnl.h index renamed from include/linux/avf/virtchnl.h +0
-0