rtc: pcf85063: Always clear EXT_TEST from set_time
PATCH 1/1 rtc: pcf85063: Always clear EXT_TEST from set_time
Power-on reset after the insertion of a battery does not always complete successfully, leading to corrupted register content. The EXT_TEST bit will stop the clock from running, but currently the driver will never recover.
Safely handle the erroneous state by clearing EXT_TEST as part of the usual set_time method.
--- drivers/rtc/rtc-pcf85063.c | 2 ++ 1 file changed, 2 insertions(+)
drivers/rtc/rtc-pcf85063.c +2 -0
@@ -34,6 +34,7 @@#define PCF85063_REG_CTRL1 0x00/* status */ #define PCF85063_REG_CTRL1_CAP_SEL BIT(0)#define PCF85063_REG_CTRL1_STOP BIT(5) +#define PCF85063_REG_CTRL1_EXT_TEST BIT(7)#define PCF85063_REG_CTRL2 0x01#define PCF85063_CTRL2_AF BIT(6)
@@ -117,6 +118,7 @@ static int pcf85063_rtc_set_time(struct device *dev, struct rtc_time *tm)* reset state until all time/date registers are written */ rc =regmap_update_bits (pcf85063->regmap,PCF85063_REG_CTRL1 , +PCF85063_REG_CTRL1_EXT_TEST |PCF85063_REG_CTRL1_STOP ,PCF85063_REG_CTRL1_STOP );if (rc)
Signature · 1 line
2.25.1
Quoted 9 lines · Phil Elwell
Power-on reset after the insertion of a battery does not always complete successfully, leading to corrupted register content. The
EXT_TESTbit will stop the clock from running, but currently the driver will never recover.Safely handle the erroneous state by clearing
EXT_TESTas part of the usualset_timemethod.[...]
Applied, thanks!
[1/1] rtc: pcf85063: Always clear EXT_TEST from set_time
commit: 9f08c9ed580a287de6546044e28f15bb183d00ff
Best regards,
Signature · 1 line
Alexandre Belloni <[email protected]>