Skip to contentSkip to conversation

Maximum number of transient objects?

tpm2 Petr Gotthard 1 participant 1 message Oct 15, 2021

lore
Share & tools
lore

Petr Gotthard

author
#0 lore raw

Hello,

I still wonder how many transient objects (virtual handles) can I create with the tpm2-abrmd?

There is TPM_PT_HR_TRANSIENT_MIN, which is said to be a minimum. An explanation from Tadeusz: This tells you what is the minimum number of persistent objects a TPM needs to support to be able to support all TPM command implemented by the given TPM chip.
But then there are statements in the RM specification that:
For the TPM this is a minimum, but for the RM it’s both a minimum and a maximum for the maximum number of loaded objects. (Section 3.15.3)
The RM SHALL NOT allow the creation of more concurrent objects than TPM_PT_HR_TRANSIENT_MIN. (Section 3.15.12)

Does this mean that for one connection the tpm2-abrmd will allow only (max) TPM_PT_HR_TRANSIENT_MIN transient objects?
Because the section 3.4 then says
A TAB/RM MAY enforce a maximum number of session and/or object and sequence handles per connection and MAY guarantee a minimum number of such handles per connection.


Petr