serial: 8250_pci patches to address issues with pericom_do_set_divisor()
v2 cover serial: 8250_pci patches to address issues with pericom_do_set_divisor()
A series patches to address three issues one customer managed to hit all at once.
1) Fourth port not being setup correctly on some Pericom chips. Fix the entries in pci_serial_quirks array.
2) Rewrite pericom_do_set_divisor() to always calc divisor and to use the uartclk instead of a hard coded value. Always calculate divisor without passing control to serial8250_do_set_divisor().
Jay, can you retest this, please?
Changelog v2:
- dropped no-fixes patch, left only fixes here
- amended refactoring of the ->set_divisor()
- fixed Fixes tags
Jay Dolan (2):
serial: 8250_pci: Fix ACCES entries in pci_serial_quirks array
serial: 8250_pci: rewrite pericom_do_set_divisor()
drivers/tty/serial/8250/8250_pci.c | 39 +++++++++++++++++++----------- 1 file changed, 25 insertions(+), 14 deletions(-)
Signature · 1 line
2.33.0
PATCH v2 1/2 serial: 8250_pci: Fix ACCES entries in pci_serial_quirks array
From: Jay Dolan <[email protected]>
Fix error in table for PCI_DEVICE_ID_ACCESIO_PCIE_ICM_4S that caused it and PCI_DEVICE_ID_ACCESIO_PCIE_ICM232_4 to be missing their fourth port.
--- drivers/tty/serial/8250/8250_pci.c | 9 ++++++++- 1 file changed, 8 insertions(+), 1 deletion(-)
drivers/tty/serial/8250/8250_pci.c +8 -1
@@ -2291,12 +2291,19 @@ static struct pci_serial_quirk pci_serial_quirks[] = { .setup = pci_pericom_setup_four_at_eight, }, { - .vendor = PCI_DEVICE_ID_ACCESIO_PCIE_ICM_4S, + .vendor = PCI_VENDOR_ID_ACCESIO, .device = PCI_DEVICE_ID_ACCESIO_PCIE_ICM232_4, .subvendor = PCI_ANY_ID, .subdevice = PCI_ANY_ID, .setup = pci_pericom_setup_four_at_eight, }, + { + .vendor = PCI_VENDOR_ID_ACCESIO, + .device = PCI_DEVICE_ID_ACCESIO_PCIE_ICM_4S, + .subvendor = PCI_ANY_ID, + .subdevice = PCI_ANY_ID, + .setup = pci_pericom_setup_four_at_eight, + }, { .vendor = PCI_VENDOR_ID_ACCESIO, .device = PCI_DEVICE_ID_ACCESIO_MPCIE_ICM232_4,
Signature · 1 line
2.33.0
PATCH v2 2/2 serial: 8250_pci: rewrite pericom_do_set_divisor()
In reply to Andy ShevchenkoFrom: Jay Dolan <[email protected]>
Have pericom_do_set_divisor() use the uartclk instead of a hard coded value to work with different speed crystals. Tested with 14.7456 and 24 MHz crystals.
Have pericom_do_set_divisor() always calculate the divisor rather than call serial8250_do_set_divisor() for rates below baud_base.
Do not write registers or call serial8250_do_set_divisor() if valid divisors could not be found.
--- drivers/tty/serial/8250/8250_pci.c | 30 +++++++++++++++++------------- 1 file changed, 17 insertions(+), 13 deletions(-)
drivers/tty/serial/8250/8250_pci.c +17 -13
@@ -1324,29 +1324,33 @@ pericom_do_set_divisor(struct uart_port *port, unsigned int baud, {int scr;int lcr; -int actual_baud; -int tolerance; -for (scr =5 ; scr <=15 ; scr++) { - actual_baud =921600 *16 / scr; - tolerance = actual_baud /50 ; +for (scr =16 ; scr >4 ; scr--) { +unsigned int maxrate = port->uartclk / scr; +unsigned int divisor = maxrate / baud; +int delta = maxrate / divisor - baud; -if ((baud < actual_baud + tolerance) && - (baud > actual_baud - tolerance)) { +if (baud > maxrate + baud /50 ) +continue ; +if (divisor ==0 || delta > baud /50 ) + divisor++; + +if (divisor >0xffff ) +continue ; + +/* Update delta due to possible divisor change */ + delta = maxrate / divisor - baud; +if (abs (delta) < baud /50 ) { lcr =serial_port_in (port,UART_LCR );serial_port_out (port,UART_LCR , lcr |0x80 ); - -serial_port_out (port,UART_DLL ,1 ); -serial_port_out (port,UART_DLM ,0 ); +serial_port_out (port,UART_DLL , divisor &0xff ); +serial_port_out (port,UART_DLM , divisor >>8 &0xff );serial_port_out (port,2 ,16 - scr);serial_port_out (port,UART_LCR , lcr);return ; - }else if (baud > actual_baud) { -break ; } } -serial8250_do_set_divisor (port, baud, quot, quot_frac); } static int pci_pericom_setup(struct serial_private *priv, const struct pciserial_board *board,
Signature · 1 line
2.33.0
Quoted 11 lines · Andy Shevchenko
A series patches to address three issues one customer managed to hit all at once.
1) Fourth port not being setup correctly on some Pericom chips. Fix the entries in
pci_serial_quirksarray.2) Rewrite
pericom_do_set_divisor()to always calc divisor and to use the uartclk instead of a hard coded value. Always calculate divisor without passing control toserial8250_do_set_divisor().Jay, can you retest this, please?
I was able to verify that the fourth port was placed at the fixed address for the card that previously had it at the wrong offset. I was also able to verify all of the standard baud rates for 24 and 14.7456 MHz crystals from 50 to their respective uartclk speed on the oscilloscope.
Quoted 13 lines
Changelog v2:
- dropped no-fixes patch, left only fixes here
- amended refactoring of the ->set_divisor()
- fixed Fixes tagsJay Dolan (2):
serial: 8250_pci: Fix ACCES entries inpci_serial_quirksarray
serial: 8250_pci: rewritepericom_do_set_divisor()drivers/tty/serial/8250/8250_pci.c | 39 +++++++++++++++++++----------- 1 file changed, 25 insertions(+), 14 deletions(-)
Quoted 11 lines · Jay Dolan
Quoted 10 lines · Andy Shevchenko
A series patches to address three issues one customer managed to hit all at once.
1) Fourth port not being setup correctly on some Pericom chips. Fix the entries in
pci_serial_quirksarray.2) Rewrite
pericom_do_set_divisor()to always calc divisor and to use the uartclk instead of a hard coded value. Always calculate divisor without passing control toserial8250_do_set_divisor().
Quoted 6 lines
Quoted 1 line
Jay, can you retest this, please?
I was able to verify that the fourth port was placed at the fixed address for the card that previously had it at the wrong offset. I was also able to verify all of the standard baud rates for 24 and 14.7456 MHz crystals from 50 to their respective uartclk speed on the oscilloscope.
Thanks!
Signature · 2 lines
With Best Regards, Andy Shevchenko
Quoted 2 lines · Andy Shevchenko
Quoted 1 line · Jay Dolan
On 11/17/21 6:55 AM, Andy Shevchenko wrote:
...
Quoted 8 lines
Quoted 6 lines
Quoted 1 line
Jay, can you retest this, please?
I was able to verify that the fourth port was placed at the fixed address for the card that previously had it at the wrong offset. I was also able to verify all of the standard baud rates for 24 and 14.7456 MHz crystals from 50 to their respective uartclk speed on the oscilloscope.
Thanks!
Greg, there is a subtle bug found in the second patch, I'll issue the v2 soon.
Signature · 2 lines
With Best Regards, Andy Shevchenko