[PATCH net 0/2]
Subsystems (4)
cover [PATCH net 0/2]
With information from me and my nagging, Russell has produced two fixes for phylink, which add code that triggers another phylink_resolve() from phylink_resolve(), if certain conditions are met:
interface is being changed
or
link is down and previous link was up
These are needed because sometimes the PCS callbacks may provide stale values if link / speed / ...
Marek Behún (2):
net: phylink: Force link down and retrigger resolve on interface
change
net: phylink: Force retrigger in case of latched link-fail indicator
drivers/net/phy/phylink.c | 19 ++++++++++++++++++- 1 file changed, 18 insertions(+), 1 deletion(-)
Signature · 1 line
2.32.0
PATCH 1/2 net: phylink: Force link down and retrigger resolve on interface change
On PHY state change the phylink_resolve() function can read stale information from the MAC and report incorrect link speed and duplex to the kernel message log.
Example with a Marvell 88X3310 PHY connected to a SerDes port on Marvell 88E6393X switch:
- PHY driver triggers state change due to PHY interface mode being changed from 10gbase-r to 2500base-x due to copper change in speed from 10Gbps to 2.5Gbps, but the PHY itself either hasn't yet changed its interface to the host, or the interrupt about loss of SerDes link hadn't arrived yet (there can be a delay of several milliseconds for this), so we still think that the 10gbase-r mode is up
- phylink_resolve()
- phylink_mac_pcs_get_state()
- this fills in speed=10g link=up
- interface mode is updated to 2500base-x but speed is left at 10Gbps
- phylink_major_config()
- interface is changed to 2500base-x
- phylink_link_up()
- mv88e6xxx_mac_link_up()
- .port_set_speed_duplex()
- speed is set to 10Gbps
- reports "Link is Up - 10Gbps/Full" to dmesg
Afterwards when the interrupt finally arrives for mv88e6xxx, another resolve is forced in which we get the correct speed from phylink_mac_pcs_get_state(), but since the interface is not being changed anymore, we don't call phylink_major_config() but only phylink_mac_config(), which does not set speed/duplex anymore.
To fix this, we need to force the link down and trigger another resolve on PHY interface change event.
--- drivers/net/phy/phylink.c | 13 ++++++++++++- 1 file changed, 12 insertions(+), 1 deletion(-)
drivers/net/phy/phylink.c +12 -1
@@ -963,6 +963,7 @@ static void phylink_resolve(struct work_struct *w)struct phylink_link_state link_state;struct net_device *ndev = pl->netdev;bool mac_config = false; +bool retrigger = false;bool cur_link_state;mutex_lock (&pl->state_mutex);
@@ -976,6 +977,7 @@ static void phylink_resolve(struct work_struct *w) link_state.link = false; }else if (pl->mac_link_dropped) { link_state.link = false; + retrigger = true; }else {switch (pl->cur_link_an_mode) {case MLO_AN_PHY :
@@ -1000,6 +1002,15 @@ static void phylink_resolve(struct work_struct *w)/* Only update if the PHY link is up */ if (pl->phydev && pl->phy_state.link) { +/* If the interface has changed, force a +* link down event if the link isn't already +* down, and re-resolve. +*/ +if (link_state.interface != + pl->phy_state.interface) { + retrigger = true; + link_state.link = false; + } link_state.interface = pl->phy_state.interface;/* If we have a PHY, we need to update with
@@ -1042,7 +1053,7 @@ static void phylink_resolve(struct work_struct *w)else phylink_link_up (pl, link_state); } -if (!link_state.link && pl->mac_link_dropped) { +if (!link_state.link && retrigger) { pl->mac_link_dropped = false;queue_work (system_power_efficient_wq, &pl->resolve); }
Signature · 1 line
2.32.0
PATCH 2/2 net: phylink: Force retrigger in case of latched link-fail indicator
In reply to Marek BehúnOn mv88e6xxx 1G/2.5G PCS, the SerDes register 4.2001.2 has the following description:
This register bit indicates when link was lost since the last read. For the current link status, read this register back-to-back.
Thus to get current link state, we need to read the register twice.
But doing that in the link change interrupt handler would lead to potentially ignoring link down events, which we really want to avoid.
Thus this needs to be solved in phylink's resolve, by retriggering another resolve in the event when PCS reports link down and previous link was up.
The wrong value is read when phylink requests change from sgmii to 2500base-x mode, and link won't come up. This fixes the bug.
--- drivers/net/phy/phylink.c | 6 ++++++ 1 file changed, 6 insertions(+)
drivers/net/phy/phylink.c +6 -0
@@ -994,6 +994,12 @@ static void phylink_resolve(struct work_struct *w)case MLO_AN_INBAND :phylink_mac_pcs_get_state (pl, &link_state); +/* The PCS may have a latching link-fail indicator. +* If the PCS link goes down, retrigger a resolve. +*/ +if (!link_state.link && cur_link_state) + retrigger = true; +/* If we have a phy, the "up" state is the union of * both the PHY and the MAC */
Signature · 1 line
2.32.0
Russell King (Oracle)
maintainerRe: [PATCH net 1/2] net: phylink: Force link down and retrigger resolve on interface change
In reply to Marek BehúnQuoted 30 lines · Marek Behún
On PHY state change the
phylink_resolve()function can read stale information from the MAC and report incorrect link speed and duplex to the kernel message log.Example with a Marvell 88X3310 PHY connected to a SerDes port on Marvell 88E6393X switch:
- PHY driver triggers state change due to PHY interface mode being changed from 10gbase-r to 2500base-x due to copper change in speed from 10Gbps to 2.5Gbps, but the PHY itself either hasn't yet changed its interface to the host, or the interrupt about loss of SerDes link hadn't arrived yet (there can be a delay of several milliseconds for this), so we still think that the 10gbase-r mode is up
-phylink_resolve()
-phylink_mac_pcs_get_state()
- this fills in speed=10g link=up
- interface mode is updated to 2500base-x but speed is left at 10Gbps
-phylink_major_config()
- interface is changed to 2500base-x
-phylink_link_up()
-mv88e6xxx_mac_link_up()
- .port_set_speed_duplex()
- speed is set to 10Gbps
- reports "Link is Up - 10Gbps/Full" to dmesgAfterwards when the interrupt finally arrives for mv88e6xxx, another resolve is forced in which we get the correct speed from
phylink_mac_pcs_get_state(), but since the interface is not being changed anymore, we don't callphylink_major_config()but onlyphylink_mac_config(), which does not set speed/duplex anymore.
Quoted 6 lines
To fix this, we need to force the link down and trigger another resolve on PHY interface change event.
Fixes 9525ae83959b ("phylink: add phylink infrastructure")Signed-off-by Russell King (Oracle) <[email protected]>Signed-off-by Marek Behún <[email protected]>
I'm pretty sure someone will highlight that the author of the patch should be the first sign-off - which doesn't match given the way you've sent this patch. That probably needs fixing before it's applied.
Signature · 2 lines
RMK's Patch system: https://www.armlinux.org.uk/developer/patches/ FTTP is here! 40Mbps down 10Mbps up. Decent connectivity at last!
Russell King (Oracle)
maintainerRe: [PATCH net 2/2] net: phylink: Force retrigger in case of latched link-fail indicator
In reply to Marek BehúnQuoted 15 lines · Marek Behún
On mv88e6xxx 1G/2.5G PCS, the SerDes register 4.2001.2 has the following description:
This register bit indicates when link was lost since the last read. For the current link status, read this register back-to-back.Thus to get current link state, we need to read the register twice.
But doing that in the link change interrupt handler would lead to potentially ignoring link down events, which we really want to avoid.
Thus this needs to be solved in phylink's resolve, by retriggering another resolve in the event when PCS reports link down and previous link was up.
Quoted 6 lines
The wrong value is read when phylink requests change from sgmii to 2500base-x mode, and link won't come up. This fixes the bug.
Fixes 9525ae83959b ("phylink: add phylink infrastructure")Signed-off-by Russell King (Oracle) <[email protected]>Signed-off-by Marek Behún <[email protected]>
Same issue with this patch wrt authorship vs sign-off.
Signature · 2 lines
RMK's Patch system: https://www.armlinux.org.uk/developer/patches/ FTTP is here! 40Mbps down 10Mbps up. Decent connectivity at last!
Russell King (Oracle)
maintainerRe: [PATCH net 2/2] net: phylink: Force retrigger in case of latched link-fail indicator
In reply to Marek BehúnQuoted 11 lines · Marek Behún
On mv88e6xxx 1G/2.5G PCS, the SerDes register 4.2001.2 has the following description:
This register bit indicates when link was lost since the last read. For the current link status, read this register back-to-back.Thus to get current link state, we need to read the register twice.
But doing that in the link change interrupt handler would lead to potentially ignoring link down events, which we really want to avoid.
Quoted 6 lines
Thus this needs to be solved in phylink's resolve, by retriggering another resolve in the event when PCS reports link down and previous link was up.
The wrong value is read when phylink requests change from sgmii to 2500base-x mode, and link won't come up. This fixes the bug.
I've also been re-thinking this patch - I don't think it's sufficient to completely solve the problem, and I think this is required to make it bullet-proof.
I suspect the reason no problem is being seen is that normally, the BMSR is read prior to calling phylink_mac_change() which will "unlatch" the bit.
drivers/net/phy/phylink.c +10 -3
@@ -1097,10 +1097,17 @@ static void phylink_resolve(struct work_struct *w)phylink_mac_pcs_get_state (pl, &link_state);/* The PCS may have a latching link-fail indicator. -* If the PCS link goes down, retrigger a resolve. +* If the link was up, bring the link down and +* re-trigger the resolve. Otherwise, re-read the +* PCS state to get the current status of the link. */ -if (!link_state.link && cur_link_state) - retrigger = true; +if (!link_state.link) { +if (cur_link_state) + retrigger = true; +else +phylink_mac_pcs_get_state (pl, + &link_state); + }/* If we have a phy, the "up" state is the union of * both the PHY and the MAC
Signature · 2 lines
RMK's Patch system: https://www.armlinux.org.uk/developer/patches/ FTTP is here! 40Mbps down 10Mbps up. Decent connectivity at last!
Re: [PATCH net 1/2] net: phylink: Force link down and retrigger resolve on interface change
In reply to Russell King (Oracle)Quoted 34 lines · On Tue, 23 Nov 2021 11:20:59 +0000 "Russell King (Oracle)"…
Quoted 33 lines · Marek Behún
On PHY state change the
phylink_resolve()function can read stale information from the MAC and report incorrect link speed and duplex to the kernel message log.Example with a Marvell 88X3310 PHY connected to a SerDes port on Marvell 88E6393X switch:
- PHY driver triggers state change due to PHY interface mode being changed from 10gbase-r to 2500base-x due to copper change in speed from 10Gbps to 2.5Gbps, but the PHY itself either hasn't yet changed its interface to the host, or the interrupt about loss of SerDes link hadn't arrived yet (there can be a delay of several milliseconds for this), so we still think that the 10gbase-r mode is up
-phylink_resolve()
-phylink_mac_pcs_get_state()
- this fills in speed=10g link=up
- interface mode is updated to 2500base-x but speed is left at 10Gbps
-phylink_major_config()
- interface is changed to 2500base-x
-phylink_link_up()
-mv88e6xxx_mac_link_up()
- .port_set_speed_duplex()
- speed is set to 10Gbps
- reports "Link is Up - 10Gbps/Full" to dmesgAfterwards when the interrupt finally arrives for mv88e6xxx, another resolve is forced in which we get the correct speed from
phylink_mac_pcs_get_state(), but since the interface is not being changed anymore, we don't callphylink_major_config()but onlyphylink_mac_config(), which does not set speed/duplex anymore.To fix this, we need to force the link down and trigger another resolve on PHY interface change event.
Quoted 9 lines
Quoted 3 lines
Fixes 9525ae83959b ("phylink: add phylink infrastructure")Signed-off-by Russell King (Oracle) <[email protected]>Signed-off-by Marek Behún <[email protected]>I'm pretty sure someone will highlight that the author of the patch should be the first sign-off - which doesn't match given the way you've sent this patch. That probably needs fixing before it's applied.
Hmm. Well you're the author of the patch, I only wrote the commit message. But I forgot to change --author in git commit. I shall resend this.
Marek